Professional Documents
Culture Documents
Alstom - Wet FGD Overview and Operation PDF
Alstom - Wet FGD Overview and Operation PDF
• Introduction
• Controls
• Summary
STACK ABSORBER
WATER
SPRAY TOWER
ABSORBER
ELECTROSTATIC MAKE-UP
PRECIPITATOR TO BALL WATER
MILL TANK
CHLORIDE
PURGE
LIMESTONE
HYDROCLONE
GYPSUM
DEWATERING
FROM MW
TANK
REAGENT
BALL MILL
PREPARATION
• Introduction
• Controls
• Summary
Absorber
Spray Switchgear
Pumps
Oxidation
Compressors
• Highly corrosive
environment
− SO3 condensation
− Deposits/splash-back
• Design/construction
− Solid 3/16” thick C-276
− 10º slope toward absorber
− Extends 10-15 ft. from shell
− Internal overhead deflector
and side shields
− Test ports and emergency
quench nozzles
− Gas velocity – 3,000-3,600
ft/min
Flared-Side Straight-Side
• Spray flow
– Typical afternoon
thunderstorm – 1-2 in/hr
– Spray tower – 10 ft/min
• Design Approach
− Intimate gas/liquid contact
− No gas sneakage
• Multiple spray stages depending
on SO2 inlet and removal
efficiency
• Overall spray coverage (>200% at
3-feet) and nozzle distribution to
provide even distribution and
prevent gas sneakage.
• Wall rings to prevent gas
sneakage near side walls.
• Pressure drop vs. pumping power
trade-off
Mist Eliminator
Spray Zone
Carryover
5 10 15 20 25
Gas Velocity (ft/sec)
Gas Flow
70,000
60,000
50,000
40,000
Flow (gpm)
30,000
20,000
10,000
Day Bin
Classifier
Ball Mill
Feed
Tank
REAGENT
SILO
CLASSIFIER
TO
ABSORBER
FROM MW TANK
BALL MILL
REAGENT
BALL MILL
FEED
RECYCLE
TANK
TANK
• Limestone grinding
− Horizontal/vertical
wet ball mills
− On-site vs. off-site
preparation
• Product ground to
90-95% < 44 μ; 30% solids
• Rubber-lined with
hardened steel balls
Hydroclone
Belt Filter
Vacuum
Pump
WPCA Wet FGD Seminar - December 1, 2008
Primary Dewatering
• Initial solid/liquid separation
step
− Feed: 15-20% TSS
− Underflow: 50-55% TSS
− Overflow: 3-5% TSS
• Overflow enriched with
CaCO3 due to particle size
difference; improved reagent
utilization
• Steel casing with rubber,
urethane, and ceramic
internals
• Typical specification:
− >95% CaSO4•2H2O
− <0.5–1.0% CaSO3•½H2O
− <100 ppm Cl
− <10% moisture
− pH 6–8
− 30–40µ MMD
• Requires:
− High purity limestone (95–
96%)
− High efficiency ESP/FF
− 99+% oxidation
− Belt filter
− Cake washing
• Introduction
• Controls
• Summary
STACK
ELECTROSTATIC
PRECIPITATOR
ID FAN
STACK
ABSORBER
ELECTROSTATIC
PRECIPITATOR
ID FAN
STACK
ABSORBER
ELECTROSTATIC
PRECIPITATOR
BOOSTER
ID FAN
FAN
STACK
ABSORBER
ELECTROSTATIC
PRECIPITATOR BOOSTER
FAN
ID FAN
• Introduction
• Controls
• Summary
Remote Remote
I/O I/O
pH L
Make-Up
Reagent Water
Feed D
Solids /
Gypsum
Bleed
WPCA Wet FGD Seminar - December 1, 2008
pH / Reagent Feed Control
z Scrubbing Liquor pH
– Most important process variable
to be controlled in WFGD →
continuous, in-line monitoring,
daily lab verification
– Indication of the amount of
CaCO3 in scrubbing solution 0 7 14
acid Neutral base
– Scrubbing liquor below desired
range → lower SO2 removal H2O
efficiency
– Scrubber liquor above desired 5.3 – 5.8
range → higher SO2 removal Scrubbing
efficiency, excess CaCO3 and Liquor pH
reduced gypsum byproduct purity
LS Flow Controller
Absorber
FE Limestone
slurry
Reaction Tank
pH
pH
pH Controller
LOCAL
DISPLAY
PANELS
TRANSMITTERS
pH PROBES
PROCESS
PIPING
Flue Gas
z Scrubber Slurry Solids Water Vapor
– Important WFGD process
variable, verified daily with
laboratory samples Mist
Eliminator
– Scrubber slurry solids: gypsum, Wash Water
Dewatering
limestone, flyash, inerts Return
Flue Gas Make-up
– Numerous inputs affecting water Water Vapor Water
balance and solids concentration
– Control solids concentration Limestone Slurry
Absorber
within narrow range: 14-16 wt.% Oxidation Air Bleed Stream
z Solids Control Sat. Water
Return to
Absorber
Absorber
Primary
Dewatering
Hydroclones
Reaction Tank
L
L Secondary
LEVEL Dewatering
DE
DENSITY
ABSORBER BLEED
PUMPS
WPCA Wet FGD Seminar - December 1, 2008
Density Measurement
• Nuclear Density Meters
− Source emits gamma
radiation through process
− Detector measures energy
of radiation
− Capable of detecting
process variations within
desired narrow range
− Safe Nuclear Density Meter
− Accurate
− Simple calibration
− Verify with laboratory
analyses
PROCESS
SLURRY LOCAL
DISPLAY
PANEL
DENSITY
METER
Level Controller
Absorber
Make-up water
Reaction Tank
L f(x)
OX AIR
L f(x)
DE DY
DENSITY
NEW STACK
EXISTING
STACK
F
STACK REVERSE FLOW ID Fan Load,
Boiler MW
DUCT PRESSURE
ZY
VANE PITCH
CONTROL
SPRAY TOWER
ABSORBER
BOOSTER FANS
ID FANS
SO2
TREATED FLUE
GAS
EXISTING
STACK
UNTREATED
FLUE GAS ID FAN LOAD,
(BYPASS) BOILER (MW)
ZY
DUCT
PRESSURE VANE PITCH
CONTROL
ID FANS P
SPRAY TOWER
ABSORBER
BOOSTER FANS
ID FANS
WPCA Wet FGD Seminar - December 1, 2008
Emergency Quench
OUTLET (CLEAN)
FLUE GAS
TY QUENCH
WATER
INLET FLUE
GAS
SPRAY TOWER
ABSORBER
WPCA Wet FGD Seminar - December 1, 2008
Agenda
• Introduction
• Controls