) 2 Push out on the latch on the right side of the housing (1) and gently
Insert screwdriver into slot on bottom (1) at angle shown, and pull up on the printed circuit board (PCB) to remove (2). Select wire
push down (2) to remove cover (3). and wall mount knock outs to be used and carefully break them out.
2
MX-200 Passive Infrared Motion Sensor Installation Instructions
1
Mounting Height
3 Pull wire out of wall and remove 8 cm (3“)of cable jacket. Insert 4 Mount in the desired location. Set alignment post in the correct
wires into back housing and attach with wire tie. Cut excess wire position for the mounting height and range desired.
tie.
Do not use
for wires
5 Pull wires toward top of unit and replace PCB. 6 Connect wires to terminal as shown using wire size 0.3 - 1.0 mm2
(18-22 AWG). Observe the proper polarity.
7 Use jumper W2 to select alarm sensitivity according to environmen- 8 Replace front cover and apply power to the sensor. Allow the sensor to
tal conditions. The Standard environment setting is adequate for warm-up for three minutes. Begin walk-test after the ALARM LED goes off.
nearly all installations. At Standard sensitivity, 2-4 steps should cause an alarm.
Environment: A=Standard B=Harsh
Jumper W2
A
+ =
Jumper W2
2-4 Steps
=
B
+ =
2-4 Steps
3-5 Steps
MOUNTING LOCATION GUIDELINES DETECTION PATTERNS 15 m 50’
Standard
The MX-200 is designed for use indoors. Mount the sensors on a wall which will TOP VIEW Wide Angle Lens Environment
12 m 40’
be at a similar temperature to that of the monitored area. Make sure that the Harsh
Environment
sensor has a clear line-of-sight to the protected area. Since infrared light cannot NOTE: Harsh environments are
9m 30’
penetrate solid objects, the sensor must “see” an area to detect a moving those where the conditions listed 6m 20’
person. Aim the sensor toward the interior, away from windows and heating/ in the Mounting Guidelines 3m
cooling sources, avoiding direct or reflected sunlight. The unit can be corner, wall, section cannot be avoided.
10’
MX-200 Passive Infrared Motion Sensor Supplemental Information
or bracket mounted. 0 0
Configure jumper W2 for pulse processing to best suit the environment. 6m 20’
(Factory default settings shown in grey.)
9m 30’
Environment Jumper W2 Position
12 m 40’
Standard Jumper top and center pins
15 m 50’
Harsh Jumper center and bottom pins 0
3m
(10’)
6m
(20’)
9 m 12 m 15 m
(30’) (40’) (50’)
desired: 0 3m 6m 9 m 12 m 15 m
(10’) (20’) (30’) (40’) (50’)
PN 5-051-618-00 Rev A