1. Variable orifice technology centers flow within the pipe, protecting the valve body and downstream piping.
ASME B16.34: Valve design and testing ASME Section IX: Pressure containing weld procedure qualifications
ASME B16.5 & B16.47: Flange rating and construction MSS-SP 81 and 135: Valve face-to-face and pressure ratings
ASME Section VIII Div 1: Non-destructive examination ANSI FCI 70-2: Leakage class designation for metal seated control valves
SlurryFlo manufactures a full range of ANSI 150, ANSI 300 and ANSI 600 control valves.
www.slurryflo.com
STANDARD PRODUCT DESIGN
TEMPERATURE AND PRESSURE RATING:
SlurryFlo follows ASME B16.34 pressure and temperature rating system (ANSI Pressure Rating).
The maximum design temperature for our control valve is 230°C (450°F).
The maximum design pressure for our control valve is based on the ANSI 600 rating of 1480 Psi (10204 kPa).
* Depending on the composition and unique characteristics of the fluid, SlurryFlo may
select an open bonnet design for lower % solids. The guidelines above are a general
rule and the final design decision is dependent on each application.
** The maximum % solids for the enclosed bonnet design will be evaluated on the
case-by-case basis for each application.
It is best to install the valve with a sufficient length of straight pipe (both
upstream and downstream) to reduce turbulence. The following set-up
is recommended:
NOTE: Image above is an example of a standard fabricated control valve with a pneumatic actuator.