4 LV PANELS - -
7 LIGHTNING PROTECTION - -
166,368,736.00 14,767,905.00
EXCLUSIONS:
7 EPABX
8 Equipments & wiring for Low voltage equipments such as security system , BMS etc.,
10 Civil works like treches, Trafo HT foundation etc., ( To be considered under civil package)
INCLUSIONS:
1 Electrical scope for PHE works limited to providing cables up to PHE panel Incomer
2 Electrical scope for STP works limited to providing cables up to STP panel Incomer
3 Electrical scope for fire fighting works limited to providing cables up to Fire panel Incomer.
HT BOQ
SUPPLY INSTALLATION
S.No. DESCRIPTION OF WORK UNIT QUANTITY
RATE AMOUNT RATE AMOUNT
PREAMBLE :
Scope of Work : Whether explicitly mentioned or not, all the works listed in
this document shall be considered as : for supply, installation, testing and
1 commissioning. All the works listed in this document shall be read in
conjunction with relavant drawings, technical specifications accompanying
the tender and this preamble.
Civil works : Unless otherwise specified all major civil works such as cable
2
trench, foundation for HT works are excluded from the scope of work.
d. Liasoning with any statutory body who is a part of clearing the approvals.
The bidder shall submit on demand the following split on the total quoted
value for each item to facilitate end user availing exemption of duty
benefits as applicable for software firms / SEZ units.
For all the Panel details refer Power Distribution Schematic Diagram
1.0 HT Works :
Note:
HT Panel board shall consist of DC supply itself with power pack (power
pack consist of PT which is able to convert AC to DC. This can be used to
supply DC Power to HT Panel) (Batteries shall be SMF type).
VCB and Vaccum Interrupter shall be Motor operated,Horizontal drawout &
Vertical Isolation.
All CTs in the VCB shall be dual core type.
All relays shall be Numeric type and Sutable for BMS compactability.
Scope of Work : Whether explicitly mentioned or not, all the works listed in this
1 document shall be considered as : for supply, installation, testing and commissioning.
All the works listed in this document shall be read in conjunction with relavant
drawings, technical specifications accompanying the tender and this preamble.
Civil works : Unless otherwise specified all major civil works such as cable trench,
2 foundation for HT works are excluded from the scope of work.
Transformers : Vendor shall consider necessary base channels and stoppers for the
wheel with necessary fabrication under Transformer installation work. The wheels shall
3 be provided with 3 mm thick rubber pad to contain vibration getting transferred to bus
ducts or cables.
Fabrication: Vendor shall consider 2 coats of primer and 2 coats of enamel paint -
4 shade and color as approved by Architect / Consultant for all the fabrication work listed
in the document.
5 Approvals.
Vendor shall consider the following under the scope of approvals.
a. Preparation of required drawings for obtaining approvals from CEIG.
b. Preparation of required drawings for obtaining approvals from Multistoried Building
Act.
c. Liasoning with authorities for obtaining power sanction.
d. Liasoning with any statutory body who is a part of clearing the approvals.
e.Obtaining Safety Certificate from CEIG.
f.INDOOR r type enclosure with IP 42 rating
6 Prices
Generally the rates offered shall be inclusive of all taxes, duties. i.e., customs duty,
excise duty, VAT, any other sales tax, entry taxes and service taxes as applicable.
The bidder shall submit on demand the following split on the total quoted value for
each item to facilitate end user availing exemption of duty benefits as applicable for
software firms / SEZ units.
For all the Panel details refer Power Distribution Schematic Diagram
1.0 HT Works :
33 kV - 6 Module HT Panel -Indoor
HT Panel, 33kV, Outdoor, Comprising of One Incomer with 1250A,33kV,VCB & Five
outgoings - 33 KV, 630A, VCB, 26.2kA Horizontal Draw out type Breaker. refer
1.3 distribution scheme for protections and relays. No 1 4,050,000.00 4,050,000.00 50,000.00 50,000.00
Consider All Digital meters & Protection Relays with RS 485 port.
Battery Charger
Supply, Receive, unloading at site, store, erection of 3Phase input and Single Phase
1.4 Output, 110/24V DC, 40A Battery Charger with Float & Boost charging, 100AH, 2 Volts No 1 250,000.00 250,000.00 9,500.00 9,500.00
DC Sealed Maintenance Free Batteries complete with all accessories like insulators,
clamps, bimetal connectors, M.S.support rack etc., as required. (Cable connection
between main pcc panel to battery charger to be included)
Note:
HT Panel board shall consist of DC supply itself with power pack (power pack consist of
PT which is able to convert AC to DC. This can be used to supply DC Power to HT Panel)
(Batteries shall be SMF type).
VCB and Vaccum Interrupter shall be Motor operated,Horizontal drawout & Vertical
Isolation.
All CTs in the VCB shall be dual core type.
All relays shall be Numeric type and Sutable for BMS compactability.
2.1
Supply, Unloading, storage & Laying of following sizes of 3-core, 33kV (E) HT, XLPE cable
2.1.1 33KV 3C - 400 Sq.mm XLPE, Al.(E) Rmt 800 1,675.00 1,340,000.00 340.00 272,000.00
2.1.4 12 C x 2.5 sq.mm Copper Cable Rmt 320 195.00 62,400.00 35.00 11,200.00
2.1.6 4 C x 2.5 sq.mm Copper Cable Rmt 800 95.00 76,000.00 15.00 12,000.00
2.1.7 4 C x 4.0 sq.mm Copper Cable Rmt 800 100.00 80,000.00 15.00 12,000.00
-
2.1.8 3 C x 2.5 sq.mm Copper Cable Rmt 650 75.00 48,750.00 10.00 6,500.00
2.1.9 3 C x 1.5 sq.mm Copper Sheeldeds Cable Rmt 4000 50.00 200,000.00 10.00 40,000.00
2.2 Cable Termination
Supply and erection of 33kV, E, HT, XLPE cables cable terminations with Al. / Cu. lugs,
double compression type cable glands, PVC insulation tapes and all other accessories as
required.
2.2.1 33KV 3C - 400 Sq.mm XLPE, Al.(E) (Outdoor) No 7 22,850.00 159,950.00 2,500.00 17,500.00
2.2.2 33KV 3C - 400 Sq.mm XLPE, Al.(E) (Indoor) No 11 14,550.00 160,050.00 2,500.00 27,500.00
2.2.5 7 C x 2.5 sq.mm Copper Cable No 150 350.00 52,500.00 100.00 15,000.00
2.1.9 3 C x 1.5 sq.mm Copper Sheeldeds Cable No 40 100.00 4,000.00 25.00 1,000.00
6.0 MISCELLANEOUS ITEMS :
6.1 FENCING :
Fencing the Transformer and DG yard, 2.5Meter Height vide materials listed under :
The rates quoted shall include necessary excavation, PCC for ISMB Supports, earthing
and all other acessories.
Frame size : 2.5 M x 1.5 M
M.S.Angle : 50 x 6 mm
Chain Link : 8 SWG GI.
Supporting ISMB : 75 x 40 mm
Paint : 2 Coats of Red oxide & 2 coats of enamel paint Mtr 45 3,000.00 135,000.00 1,200.00 54,000.00
Note: Extension of the exsisting fencing.
6.3 Spreading of 40 mm metal in outdoor H.T.yard - upto 100 mm - thick layer Sq.M 100 1,200.00 120,000.00 200.00 20,000.00
6.4 Danger Boards 33kV (Stove enamelled) as per power supply company standards. No 2 500.00 1,000.00 100.00 200.00
6.5 Fire Extinguisher CO2 type 4.5 Kgs. No 3 500.00 1,500.00 100.00 300.00
Fire Bucket with stand - 2 buckets. Bucket of round bottom, painted red, marked 'FIRE'
6.6 and duly filled with fire river sand. No 3 2,250.00 6,750.00 150.00
6.6 Rubber mats of 1.8 Mtrs x 0.9mts. and of 3mm thick (IS 15652) No 15 2,510.00 37,650.00 350.00 5,250.00
6.7.1 600MM dia Hume Pipe Mtr 150 650.00 97,500.00 150.00 22,500.00
6.7.4 0.45mtr x 0.45mtr x 0.45 mtr Cable Inspection Chamber with Cover No RO 2,500.00 1,650.00
6.7.5 0.6mtr x 0.6mtr x 1.0 (D) mtr Cable Inspection Chamber with Cover No 8 15,000.00 120,000.00 5,200.00 41,600.00
Cable laied in ground and the prices shall include excavation of soil and refilling,
providing sand layer below the cables, providing half cut hume pipe over and above the
6.7.6 cable for necessary mechanical protection before final refilling of soil and making good Mtr RO 1,250.00 150.00
surface as required.
2.7 Three phase Input/Three phase Output Inverter, 25KVA with suitable batteries for 90Mins No 1 - -
backup with battery stand and Supporting accessories. - Emergency
Three phase Input/Three phase Output Inverter, 40KVA with suitable batteries for 20Mins
2.8 backup with battery stand and Supporting accessories. - BMS No 1 - -
BUSDUCT
SUPPLY INSTALLATION
S.No. DESCRIPTION OF WORK UNIT QUANTITY
RATE AMOUNT RATE AMOUNT
2.0 BUS DUCT
Rating of bus duct 2500A Amps. (DG Isolator to Main LT Panel and
2.1.2 - -
Transformer to Main LT Panel and Main LT Panel to Main LT Panels)
a Straight Run Mtr 825 20,000.00 16,500,000.00 3,000.00 2,475,000.00
b Vertical/Horizontal Bend No 71 4,500.00 319,500.00 500.00 35,500.00
Terminal flange with adopter box and extention of bus bar for terminating the
c No 26 50,000.00 1,300,000.00 5,000.00 130,000.00
bus duct.
Accessories ( like Interconnecting bus bars rubber bellows, Flexible couplers,
d LS 1 50,000.00 50,000.00 5,000.00 5,000.00
Fixing Brackets, Al. Earthing and control wiring)
Raising Main
Supply, Erection, testing and commissioning of raising mains with 415V, 3PN,
4W Aluminium Sandwich type Rising Main with proper aluminium earthing, 2
2.3 Plug in Provision per Floor, Spring Hangers & Rigid Hangers( IP42)(100%-N)
including MS support. As per site requirement.(Every 600mm interval plug in
provision to be made)
Rating of bus duct 1250Amps.Tap off box provision on each floor. Max plug in
2.3.1
provision shall be rated for 400Amps. (Basement-1 to 16th floor)
Accessories ( including spring hangers, fixing clips, floor seal and 2Rx50x6mm Al
e LS 1 50,000.00 50,000.00 5,000.00 5,000.00
Earth strip , control wiring and 3Cx2.5 Sq.mm control cable for DSM)
1250 Amps, 4P, 50KA, ACB in sheet steel enclosure for feeding power supply to
f No 4 250,000.00 1,000,000.00 8,500.00 34,000.00
Rising main. With on/off/trip indication lamps.
Note: Vendor has to consider Measurement as per the site requirement.
Rating of bus duct 1000Amps.Tap off box provision on each floor. Max plug in
2.3.2
provision shall be rated for 400Amps. (Basement-1 to 29th floor)
Accessories ( including spring hangers, fixing clips, floor seal and 2Rx50x6mm Al
e LS 1 50,000.00 50,000.00 5,000.00 5,000.00
Earth strip , control wiring and 3Cx2.5 Sq.mm control cable for DSM)
1000 Amps, 4P, 50KA, ACB in sheet steel enclosure for feeding power supply to
f No 4 200,000.00 800,000.00 7,500.00 30,000.00
Rising main. With on/off/trip indication lamps.
Note: Vendor has to consider Measurement as per the site requirement.
CABLES
SUPPLY INSTALLATION
S.No. DESCRIPTION OF WORK UNIT QUANTITY
RATE AMOUNT RATE AMOUNT
3.0 Cables and end terminations
Unless specified the voltage grade of all LT Power and Control cables shall be
rated for 1100 Volts. Grade PVC insulated XLPE Al. / Cu. Conductor, steel
armoured Power Cables (XLPE A2XFY/YWY/YFY) as per specification.
Vendor shall consider necessary clamping and tagging of cables as part of cable
laying work.The cable laying shall be in excavated trenches, built in trenches,
hume pipes and on cable trays as the case may be.
3.1 Cables
3.1.1 3.5 Core x 400 Sqmm Aluminium XLPE Armoured Cable Mtr 3,100.00 1,360.00 4,216,000.00 75.00 232,500.00
- -
3.1.2 3.5 Core x 300 Sqmm Aluminium XLPE Armoured Cable Mtr 2,730.00 1,150.00 75.00 204,750.00
- -
3.1.3 3.5 Core x 240 Sqmm Aluminium XLPE Armoured Cable Mtr 1,010.00 950.00 959,500.00 75.00 75,750.00
3.1.4 3.5 Core x 185 Sqmm Aluminium XLPE Armoured Cable Mtr RO 780.00 60.00
3.1.5 3.5 Core x 150 Sqmm Aluminium XLPE Armoured Cable Mtr RO 620.00 55.00
3.1.6 3.5 Core x 120 Sqmm Aluminium XLPE Armoured Cable Mtr RO 520.00 55.00
3.1.7 3.5 Core x 95 Sqmm Aluminium XLPE Armoured Cable Mtr RO 475.00 50.00
3.1.8 3.5 Core x 70 Sqmm Aluminium XLPE Armoured Cable Mtr RO 440.00 50.00
3.1.10 3.5 Core x 35 Sqmm Aluminium XLPE Armoured Cable Mtr 1,000.00 250.00 250,000.00 40.00 40,000.00
3.1.11 3.5 Core x 25 Sqmm Aluminium XLPE Armoured Cable Mtr RO 210.00 40.00
3.1.12 4 Core x 16 Sqmm Aluminium XLPE Armoured Cable Mtr 450.00 185.00 83,250.00 40.00 18,000.00
3.1.13 4.0 Core x 10 Sqmm Aluminium XLPE Armoured Cable Mtr 1,400.00 160.00 224,000.00 40.00 56,000.00
3.1.14 4.0 Core x 6 Sqmm Aluminium XLPE Armoured Cable Mtr 200.00 125.00 25,000.00 40.00 8,000.00
3.1.15 3.0 Core x 400 Sqmm Aluminium XLPE Armoured Cable Mtr 550.00
3.1.15 3.0 Core x 150 Sqmm Aluminium XLPE Armoured Cable Mtr 75.00
3.1.15 3.0 Core x 50 Sqmm Aluminium XLPE Armoured Cable Mtr 300.00
3.1.17 3.0 Core x 35 Sqmm Aluminium XLPE Armoured Cable Mtr 300.00
3.1.16 3.0 Core x 16 Sqmm Aluminium XLPE Armoured Cable Mtr 300.00
3.1.18 3.0 Core x 10 Sqmm Aluminium XLPE Armoured Cable Mtr 520.00
3.1.21 3.0 Core x 2.5 Sqmm Copper UnArmouted cable Mtr 50.00
3.1.22 3.0 Core x 2.5 Sqmm Copper PVC Armoured Cable Mtr RO
3.1.23 3.0 Core x 1.5 Sqmm Copper Shielded Armoured Cable Mtr RO
3.1.24 1 Core x 185 Sqmm Copper Flexible PVC Cable Mtr 700.00
3.3.2 3.5 Core x 300 Sqmm Aluminium XLPE Armoured Cable NO 60.00
3.3.3 3.5 Core x 240 Sqmm Aluminium XLPE Armoured Cable NO 16.00
3.3.15 3.0 Core x 400 Sqmm Aluminium XLPE Armoured Cable NO 36.00
3.3.15 3.0 Core x 150 Sqmm Aluminium XLPE Armoured Cable NO 4.00
Unless otherwise specifically mentioned all MCB (standard) DBs shall be considered with
double door arrangement only with thickness of 1.2mm. The type of DB shall be vertical or
horizontal based on design and site conditions. The MCBs for lighting and raw power
distribution shall be considered with Curve 'C" and Curve 'D' for UPS distribution
respectively. Dummy ways to be covered with blank plates. All out going ways shall be
labeled & laminated as built drawing (SLD) shall be affixed on inside face of DB door. The
MCB's shall be rated for a mimimum short circuit level of 10 kA.
Adoptor box suitable for 12 way DB with extension busbars to enable for termination upto
1.13 25Sq.mm cable. The adoptor box shall be fabricated with 16SWG CRCA Sheet steel and No RO
should be same shade of Distribution Board.
Adoptor box suitable for 8 way DB with extension busbars to enable for termination upto
1.10 25Sq.mm cable. The adoptor box shall be fabricated with 16SWG CRCA Sheet steel and No RO
should be same shade of Distribution Board.
2.0 Sockets
Supply, Erection, testing and commissioning of following switches / sockets / switch fuse
units and starters with all other accessories as required.
1No 6A Multipin socket outlet with mounting box controlled by 1 no 6A switch modular
2.1 Each 20
switch type.
1No 6A Multipin socket outlet with mounting box controlled by 1 no 6A switch modular
2.2 Each 10
switch type for UPS
1No 6A Multipin socket outlet with mounting box controlled by 1 no 6A switch modular
2.3 Each 220
switch type for UPS ( HVAC & Other Services)
1No 6/16A Multipin socket outlet with mounting box controlled by 1 no 16A switch
2.4 Each 120
modular switch type.
"AC Level 2" 240 volt single phase AC up to 80 amps industrial socket with MCB, for up to
2.5 Each RO
19.2 kiloWatt charge rate
25A Industrial type Double Pole -240V, power socket outlet with 25A MCB with Plug top
2.6 Each RO
controlled housed in polycorbonate enclosure
32A Industrial type Three -415V, power socket outlet with MCB controlled housedin
2.7 Each RO
polycorbonate enclosure
63A Industrial type Three -415V, power socket outlet with MCB controlled housedin
2.8 Each RO
polycorbonate enclosure
1No 6/16A Multipin socket outlet with mounting box controlled by 1 no 16A switch
2.9 modular switch type. (car charging sockets) Each 40
Supply, installation, testing and commissioning of clip type Lan Socket (RJ-45) along with
2.10 No 10
front plate and G.I box along with required chasing and all others complete as required.
Supply and running of 1100 V grade PVC insulated copper conductor wires in 2mm thick,
Heavy Duty, FRLS, PVC conduit as per specifications. The rate shall include supply,
installation of all materials required like wires, conduit, elbow bends, clamps, saddles and
all other fixing accessories.
Supply and running of 4R x 10 Sqmm and 2R x 6Sq.mm PVC insulated copper wire including
3.4 32mm dia PVC conduit, bends, junction boxes with terminations on either side and all Mtr RO
other accessories as required.
Supply and running of 4R x 6 Sqmm PVC insulated copper wire including 25mm dia PVC
3.5 conduit, bends, junction boxes with terminations on either side and all other accessories as Mtr RO
required.
Supply and running of 3R x 4.0Sq.mm PVC insulated copper wire Including 25mm dia PVC
3.6 Mtr 6000
conduit with terminations on either side and all other accessories as required.
Supply and running of 3R x 2.5 Sq.mm PVC insulated copper wire Including 19mm dia PVC
3.7 Mtr 38000
conduit with terminations on either side and all other accessories as required.
Supply and running of 3R x 2.5Sq.mm PVC insulated copper wire Including 25mm dia PVC
3.8 conduit with terminations on either side and all other accessories as required. Flexible Mtr 3500
cable- car charging
Wiring of light points / 6A socket outlets with 2 runs of 1.5 and 1 runs of 1.5 sq.mm FRLS
1100 V grade copper wire using 2 mm thick 19 mm dia PVC, FRLS conduit, with modular
type switches with metal boxes and accessories The point wiring shall be terminated in a
terminal block.
NOTE: The wiring drawn from DB to first switch box & power points in a room shall be
measured under the heading circuit mains.
Ceiling Fan point controlled by 6A switch & 5 Step Electronic regulator with Fan Box
4.13 No RO
concealed in ceiling
Stair Case lighting for landing and mid- landing for (B4 to Terrace) lights controlled from
10A MCB. 1Seperate ckt. With 2 x 2.5 + 1 X 1.5sq mm complete accessories like saddeles
4.14 Set 28
Chasing, chipping excluding 19 mm mm dia FRLS PVC conduit. Cost of MCB to Exclude.( for
Normal Lighting & Emergency Lighting) Refer the Stair case Conduit drawing.
4.15 Supply, Installation of Elevator Shaft Lighting for low rise passenger lifts.
DesignTree Service Consultants Pvt Ltd Page 16 of 53
Project : B-HUB (Tower-1)
4.16 Supply, Installation of Elevator Shaft Lighting for High rise passenger lifts.
a. 35 Lights controlled from 6/10 A switch / MCB
b. 1 light controlled from 2 Nos 6 A 2-way switches for pit lighting.
c. Bulk Head fixture - 36Nos with 9W LED lamp.
d. 36 Nos of 6 A 3 Pin socket outlet with mounting box controlled by 6A switch. Set 8
NOTE: All fittings shall be with electronic ballasts only. All the CFL fixtures shall be provided
with PF improvement condensor compulsorily. Tubes shall be of colour 84 (cool day light).
Also the rates quoted shall also include the cost of Lamps, ball & socket suitable for 25mm
dia conduits, round blocks, PVC holders, 25mm dia GI pipe drops for suspending the
fixtures, fans., all complete as required.
Supply, Erection, Testing & Commissioning of 1 x 20 W Surface / Wall Mounted LED Batten
tube Light with cover industrial type with all other fixing accessories as required. (Main
5.1 No 100
Electrical room, chiller room & pump room)
Supply, Erection, Testing & Commissioning of 40 W Surface / Wall Mounted LED Batten
5.2 tube Light with cover and all other fixing accessories as required. No 450
(Driveway)
Supply, Erection, Testing & Commissioning of 1 x 20 W Surface / Wall Mounted LED Batten
5.3 tube Light with cover and all other fixing accessories as required. No 700
(Parking & Service Rooms)
Supply, Erection, Testing & Commissioning of 1 x 40 W Recess Mounted LED Light Fixture
5.4 No 120
(Lobby double height)
Supply, Erection, Testing & Commissioning of 1 x 20 W Recess Mounted LED Light Fixture
5.5 No 1100
(Lobbies & Refuge area)
Supply, Erection, Testing & Commissioning of 1 x 22 Surface/wall Mounted LED fixture with
5.6 No 350
cover for ( Staircase)
5.8 Supply, Erection, Testing & Commissioning of 1 X 3W Rececss mounted LED fixture No 150
Supply, Erection, Testing & Commissioning of 1x 12W LED Bulk head Light Fixture with glass
5.8 No RO
& lamp and all other fixing accessories as required. (Terrace)
5.9 Supply, Erection, Testing & Commissioning of 1 X 30W Recess Mounted LED fixture No RO
Supply, Erection, Testing & Commissioning of 12W Recess Wall Mounted Circular down LED
5.10 Light and all other fixing accessories as required. (RAMP) No 40
Supply, Erection, Testing & Commissioning of Exit lamp Fitting (with transparent acrylic
cover) with 11W CFL lamp and with EXIT / ENTRANCE / BASEMENT inscription in
5.12 No RO
RED/Green colour along complete with built-in battery, battery charger and all other
necessary accessories as required for signage lighting.
Supply, Erection, Testing & Commissioning of 60 Watts, Outdoor type LED flood light and all
5.13 No RO
other fixing accessories as required.
Supply, Erection, Testing & Commissioning of 10 Watts, Wall mounted LED light and all
5.14 No 4
other fixing accessories as required.(GF Toilet - Mirror light)
Supply,Erection, Testing & Commissioning of 15Watts Recess Mounted LED Light Fixture
5.15 No 10
and all other fixing accessories as required.(GF Toilet)
Supply,Erection, Testing & Commissioning of 9Watts Recess Mounted LED Light Fixture and
5.16 No 6
all other fixing accessories as required.(GF Toilet)
Supply,Erection, Testing & Commissioning of 3Watts Recess Mounted LED Light Fixture and
5.17 No 4
all other fixing accessories as required.(GF Toilet)
Supply, Erection, Testing & Commissioning of LED strip rigid linear continuous light line –
5.18 Wipro - ORMZ LED LS26-005-120-WW-50 5W PER METER (Cove Lighting - Toilet & Behind No RO
Mirror)
Total C/O to Summary
Builder proposes to use automatic lighting controls for common area lighting such as
carparking areas to control/optimize the lights depending on
occupancy/movement,availability of sun light at the periphery etc.in order to conserve
energy.Thevendor shall propose a suitable system to meet the above requirement.
Micro wave presence detection sensor with a range of 20meter X 20meter at a mounting
height of 3.5meter to control lighting load of 10A,with features of delaytime10sec-
6.1 20minutes, with photocell,for semi flush mounting or surface mounting. (similar to No RO
Honeywell - MK catalog No K4032/K4033 complete with wall mounting kit K4034 or equiv)
(Parking)
Micro wave presence detection sensor with arange of 30meter X 30meter at a mounting
height of 3.5- 6mtr meter to control lighting load of 10A,with features ofdelay time10sec-
6.2 20minutes, withphotocell, for semiflush mounting or surface mounting. (similar to No RO
Honeywell-MK catalog noK 4080/81/82/ or equiv)
6.3 Day Light cum Occupancy Sensor with Lux level settings No 7
Supply and Erection of Heavy duty ladder type 2mm thick Pre galvanized tray of size as
below, ceiling suspended/ wall mounted cable tray or in Cable Trench including necessary
Anchoring in the ceiling, Angle supports, cleat angle, rungs, side runner, coupler plates,
fasteners, anchor bolts, Base plate & accessories like Elbows, Bends, Tee, all complete as
7.1 per site requirement . these all elbows, Bends, Reducers, Tees should be factory made.
(upto 600mm wide Hinged type and above 150x150x6mm MS channel base plate 600mm
-25x25x5, 750mm-40x 40x5 & above 900mm -65x65x5mm angle Supports)
Supply & Installation of heavy duty Pre galvanized perforated type Cable trays of following
sizes, suspended from ceiling or fixed vertically on wall / column as per including necessary
supports like anchor bolts, hangers, brackets etc. and accessories like Elbows, Bends, Tee,
requisite support / suspenders, hardware etc. as per site requirement. All supporting
7.2
structure & hardware including nuts & bolts and shall be of galvanized iron as approved.
Height of cable tray will be 50 mm. these all elbows, Bends, Reducers, Tees should be
factory made. (upto 600mm wide Hinged type and above 150x150x6mm MS channel base
plate 65x65x5mm angle Supports)
7.2.1 750 mm x 50mm wide Cable Tray Mtr 350
Supply & Installation of following size GI raceway /MS / wire way with cover, made out of
16 SWG GI for body and 14 SWG GI for cover.
Junction boxes to be provided with enough supports inside the box.
Raceway installed above false ceiling/floor shall include necessary mounting supports,
junction boxes and accessories to fix it firmly to the ground/ ceiling.
The raceways shall be fixed to the floor with GI (25mm x 3mm) strips so that there is no
movement of the channels when civil work (pouring of cement concrete) is being done.
8.1 Rate includes necessary floor cutting and chipping with machine of minimum 50mm depth,
removal of debris out of site and neatly finished with M15 grade concrete up to the
finished floor level. Race ways to be covered with Chicken mesh before concreting. Curing
compound to be applied after initial setting of the concrete.
All edges, cut faces shall be free of burrs & shall be smooth.
The channels shall be earthed at the boxes and at the joints with 14 SWG bare copper wire
with screws so that earth is continuous.
Jointing of the race ways to be done with welding.
8.1.2 50 x 40 mm Mtr 30
Junction boxes made out of 2 mm thick CRCA sheet duly hot dip galvanized.
8.1.3 150 x 155 x 65mm Mtr 3
SUPPLY INSTALLATION
RATE AMOUNT RATE AMOUNT
4,000.00 500.00
3,000.00 500.00
8,500.00 500.00
3,000.00 500.00
432,900.00 33,500.00
460.00 50.00
580.00 75.00
2,500.00 100.00
3,000.00 150.00
3,500.00 150.00
110,750.00 18,500.00
120.00 45.00
516.00 80.00
250.00 50.00
5,290,100.00 1,324,000.00
890.00 250.00
2,750.00 1,300.00
1,320.00 350.00
1,543,888.00 305,490.00
1,200.00 75.00
3,900.00 150.00
1,800.00 150.00
7,000.00 350.00
8,600.00 100.00
1,890.00 75.00
7,697,520.00 295,900.00
11,000.00 250.00
13,270.00 250.00 -
61,250.00 1,750.00
355.00 50.00
720.00 100.00
4,680,000.00 635,500.00
26,440.00 11,475.00
a. All the items of work shall be treated as supply, installation, testing and commissioning unless
other wise mentioned.
Supply and installation of 8 mm Aluminum Round Conductor complete as specified in drawing &
Rm 600
shall meet the requirements of IS/IEC 62305 (Terrace)
B GI Strips
Supply and installation of 25 x 6 mm GI earth Flat clamped to basement ceiling & burried in ground
connected ring aroung the tower
a) Flat conductor shall be of Hot Dipped, Zinc coating: 500 g/m square (Approx:70 micron coating),
should be tested and used exclusively for lightning protection earthing system/ring equipotential
bonding & Cross sectional area of 150mm square mm.
b) Cost to include necessary local excavation and neccessary saddle supports flat conductor holder Rm 1200
suitable nuts and blots with necessary accessories required
c) Cost to include covering the GI strips with Plastic corrosion protection strips
C Expansion Piece
Providing and installation of expansion piece with connector: For equalising temperature related
length changes. Necessary on conductors length over 20 meters on terrace parapet wall for round Nos 30
conductor
Supply and installation of 16mm Vertical Air terminal rod tapered to 10 mm aluminium rod as per
IS-IEC -62305 part-3 with all neccessary clamps and accessories
a). Terminal rod shall meet the requirement of standards (IS/IEC 62305) and suitable for high wind
load
b). Cost shall include Fang Fix Junior system inclusive of Al intrception rod of 1Mtr length(10mm dia
) , quick mounting of the interception rod in the base using plug technology
Supply and installation of conductor holder at Parapet with M8 female thread of diameter 7mm, M8
a Nos 800
Screw to connect the conductor holder. Conductor holder to be fixed @ 1 meter distance
Supply and installation of roof conductor holder for flat roof to meet standards. Holder shall be
b Nos 500
Closed form with bottom @ 1 meter distance
Providing & installation of cross universal connector: For T and cross connection, to route vertical
c down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as Nos 200
required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts
Supply and installation of Lightning counter - To count no of lightning strike & it can record the date
b Nos 1
and time of the lightning incident also tested as per IEC 62561-6.
EARTHING
The earth pit marker embedded type in concrete shall be provided for top of
iii
each earth pit as shown in drawings, since the all earth pits are concealed type.
Contractor to make documentation for each earth pit showing the installation,
iv connections & tapping with identification , earth resisitance test installation
date etc.. For staisfication for CEIG consultants
Supply laying and termination of the following sizes of earth flats and wires laid
is excavated / preformed trenches. Cable trays drawn through pipe sleeves
along with column / panels for neutral earthing as per specifications.
100 x 6 mm Cu. Strip electrolytic grade copper strip in PVC sleeve for
i Mtr
transformer / DG neutral earthing.
6 sq.mm bare copper conductor wire for earthing including termination with
x Mtr
lugs.
Busbar of 0.6 Mtr length made out of 50 x 10 mm Cu. strip with drill holes of M8
xi Nos.
at 25mm interval mounted on insulators.
Supply, laying jointing and termination of the following sizes of hot dip
galvanised earth flats and wires laid in excavated / performed trenches, Cable
trays or drawn through pipe sleeves for safety earthing as per specification. All
joints in the run of the conductor shall be welded. All welded joints below
grade level shall be protected with bitumin paint and Hessain type. All joints
above grade shall be painted with rust instibility paint. The equipment
connections shall be bolted using GI bolts & nuts.
The galvanizing coating shall be not be less than 500 gms / sq.mt.
Factory Test reports to be submitted for review
ii 75 x 10 mm GI Strip Mtr
Busbar of 0.5 Mtr length made out of 50x6 mm GI strip with drill holes of M8 at Nos.
vii 25mm interval mounted on insulators.
Busbar of 0.5 Mtr length made out of 25x6 mm GI strip with drill holes of M8 at Nos.
viii 25mm interval mounted on insulators.
Busbar of 0.5 Mtr length made out of 25x3 mm GI strip with drill holes of M8 at Nos.
ix 25mm interval mounted on insulators.
Supply and Erection of Heavy duty ladder type 2mm thick hot dipped galvanized
tray of size as below, ceiling suspended/ wall mounted cable tray or in Cable
Trench including necessary Anchoring in the ceiling, Angle supports, cleat
angle, rungs, side runner, coupler plates, fasteners, anchor bolts, Base plate &
1
accessories like Elbows, Bends, Tee, all complete as per site requirement .
these all elbows, Bends, Reducers, Tees should be factory made.(upto 600mm
wide Hinged type and above 150x150x6mm MS channel base plate 65x65x5mm
angle Supports)
SUPPLY INSTALLATION
Quantity
RATE AMOUNT RATE AMOUNT
RO 2,890.00 100.00
RO 19,200.00 100.00
RO 450.00 60.00
RO 120.00 35.00
RO 80.00 25.00
RO 80.00 20.00
RO 420.00 70.00
RO 120.00 50.00
25,478,650.00 2,295,300.00
DG Sets shall include one day fuel tank (990 litres) for each DG set. The day fuel
tank shall be fabricated from 2 mm thick MS sheets and shall include the cost of
removable cover with locking arrangement, the cost of painting, the cost of
providing all the required appurtenances like intlet & outlet connection, float
valves, drain connection, mechanical oil level indicator and low level/high level
alarms and the cost of support arrangement. complete as per specification and
as required.
The D.G. sets shall be inclusive of but not limited to the following standard
accessories:
Radiator Fan cooling system .
Fly Wheel to suit flexible/rigid coupling.
Fly wheel housing complete with starter gear ring and coupling.
Fuel hoses.
Electronic Governor.
(a) 40mm dia for 2000kVA DG Set (Master Day tank to DG Day tank and to DG
Mtr 240
Set )
(b) 40 mm Dia Ball Valves Each 10
1.3.1 (a) 25mm dia. for 1500kVA DG Set ( From DG Day tank to DG Set) Mtr RO
(b) 25mm Dia Ball Valves Each RO
1.4.1 550mm dia. 5.15mm thick Exhaust Pipe for 2000kVA DG Set Mtr 1100
1.4.1 350mm dia. 5.15mm thick Exhaust Pipe for 2000kVA DG Set Mtr 160
Silencer insulation 50mm thick LRB rock wool (64 Kg/m 3 density) insulation clad
1.4.4 Nos 5
with 26 SWG aluminum sheet cladding.
2.0 Cables :
Unless specified the voltage grade of all LT Power and Control cables shall be
rated for 1100 Volts. Grade PVC insulated XLPE Al. / Cu. Conductor, steel
armoured Power Cables (XLPE A2XFY/YWY/YFY) as per specification.
Vendor shall consider necessary clamping and tagging of cables as part of cable
laying work.The cable laying shall be in excavated trenches, built in trenches,
hume pipes and on cable trays as the case may be.
3.2 Acousticaly treated fresh air attenuator with louvers & angle frame work with
fixing accessories, to be fixed on wall, it shall be suitable for supplying required
air in CFM for DGs.Quantities are tentative and actual quantities to/be worked
out by the vendor.
3.3 Acousticallly treated hot air attenuator with angle frame work & fixing
accessories, to be fixed on hot air chamber wall (between DG room & hot air
wall), it shall be suitable for exhausting the hot air in CFM for DGs. Quantities
are tentative and actual quantities to be worked out by the vendor. Sqm 100
3.4 Acoustically treated Exhaust hot air louvers with angle frame work & fixing
accessories, to be fixed on external wall to throw hot air from chamber, it shall
be suitable for supplying required air in CFM for 4x2000kVA DGs. Work shall be
complete with blind panels, Double layer fire retardant canvas for DG Radiator
exhaust suitable for 2000KVA DG Set, Duct transformation from canvas to the hot
air plenum for 2000kVA DG Sets fabricated out of 18G GI Sheet complete with
access door duly painted with floor supports as per specifications.
3.5 Angle fabricated out of 100x50mm chanels 50x50x6 Angle with paint & supports
etc Kgs 20
3.6 Supply & errection of Double leaf Acoustic door 100mm thick with view panel-
Acoustically treated MS door with acoustic panels & angle frame- 3.7Mts (wide)
and 3.0 (Height) along with locking arrangement gaskets, Baffle, HI Tech spring No RO
supports, DG Auxiliary Panel etc.,
3.7 Supply & errection of Single leaf door with view panel Acoustically treated MS
door with acoustic panels & angle frame-for personanel entry standard size No 6
1.0Mts (wide) and 2.1 (Height).
3.8 Supply & errection of Hot air and Fresh air Baffles Sqm 25
4.2 Rubber mats of 1.1 KV grade 1.8 Mtrs x 0.9mts. and of 5mm thick No 5
4.3 Shock treatment chart with wood frame and glass cover as required No 1
Electrical single line diagram (As Built drawing ) with teakwood frame and glass
4.6 No 1
cover and Soft copy of CD
4.9 Lightning arrestor With twin LED lamp for aviation Each 1
This BOQ to be read in conjunction with technical specifications and Single Line Diagram.
If any discrepancy occurs that should be brought to the notice of Client/Consultant before quoting the price o
considered.
Vendor need to submit the Back pressure calculation
All civil foundation of DG sets shall be in the scope of the Civil Contractor. However, DG Set Contractor has to
foundation as desired.
SUPPLY INSTALLATION
RATE AMOUNT RATE AMOUNT
750.00 150.00
7,500.00 450.00
450.00 120.00
5,200.00 350.00
350.00 25.00
300.00 25.00
400.00 35.00
120.00 25.00
325.00 35.00
100.00 25.00
2,824.00 450.00
3,882.00 600.00
16,000.00 600.00
75,000.00 1,000.00
1,900.00 200.00
7,200.00 110.00
125,000.00 125,000.00
250,000.00 250,000.00
10,000.00 10,000.00
-
88,874,638.00 4,246,690.00
actor. However, DG Set Contractor has to co-ordinate with Civil Contractor for erection of the
SUPPLY INSTALLATION
S.No. DESCRIPTION OF WORK UNIT QUANTITY
RATE AMOUNT RATE AMOUNT
5.0 Miscellaneous items
5.1 2 Fire buckets of 9 Ltrs capacity with floor stand, sand and supporting acessories. No 2 1,300.00 2,600.00 150.00 300.00
5.2 Rubber mats of 1.1 KV grade 1.8 Mtrs x 0.9mts. and of 3mm thick (IS 15652) No 15 2,510.00 37,650.00 350.00 5,250.00
5.3 Shock treatment chart with teak wood frame and glass cover as required No 1 1,500.00 1,500.00 250.00 250.00
5.4 Electrical single line diagram (As Built drawing ) with frame and glass cover No 1 5,000.00 5,000.00 500.00 500.00
Supply and Installation of 4.5kg capacity CO2 type fire extinguishers complete with
5.7 mounting brackets, spray nozzles, connecting pipes, "OPEN / CLOSE" valves with all other Each 2 5,660.00 150.00
necessary accessories complete as required.
Supply and Installation of 2.0kg capacity CO2 type fire extinguishers complete with
5.8 mounting brackets, spray nozzles, connecting pipes, "OPEN / CLOSE" valves with all other Each RO 4,500.00 200.00
necessary accessories complete as required.
Push Button Actuators with Stay put type Start Push Button and Loackable type Mush
5.9 No 6 1,500.00 9,000.00 250.00 1,500.00
Room Head type Stop Push Button in a weather Proof IP - 55 enclosure.
5.10 Supplying & Erection of Danger Boards, as per Electricity Board requirement. each 2 750.00 1,500.00 50.00 100.00
5.11 Fire Sealent for the entry and exit of the Cables wherever necessary SqM 100 18,000.00 1,800,000.00 2,000.00 200,000.00
1,500.00 150.00
5.12 Camouflaging for MCB DBs made out of 1.6mm thick CRCA sheet duly powder coated SqM 200 300,000.00 30,000.00
5.14 50mm Dia GI pipe Mts 200 500.00 100,000.00 250.00 50,000.00
Temporary Lighting & Power arrangement with 500Nos of 1 x 40Watts FTL & 20 No
extension power boards with required cable as per the sit condition, 8 No 240V, 1Ph., 16A
5.15 power sockets on each board shall be provided to all agencies durring execution with LS 2 125,000.00 250,000.00 2,500.00 5,000.00
required No of Industrial type FTL light fixtures & Socket outlets,Temperary Distribution
Board for above, till commissioning stage.
Liasioning Authorities for getting the sanction of load and deposits. Preparation of as built
drawings as per Dy. CEIG standards for approval, Filing the completion report to the
Electrical Inspectorate authorities, getting the inspection done at site, filing the
compliance report, getting the approval from Electrical Inspectorate authorities and
getting the approval from Electricity Board for charging the line for the Electricity Board
portion of the work etc., including liason with Electricity Board. Single window agency
approval will be furnished by Client. (Note: Pls consider for all other agency i.e HVAC,Fire
PHE,LIFTS and DG's electrical equipments approval also)