YORK® YHAU-CL-DXS SINGLE-EFFECT

DOUBLE LIFT HOT WATER


ABSORPTION CHILLERS
Ideally Suited for Combined Heat and Power (CHP) Applications
Maximizing Performance Single-effect double lift hot water cycle with
innovative YORK® two-step evaporator and
by Design absorber design backed with an auxiliary cycle.
The YORK® YHAU-CL-DXS Single-Effect Double Lift Hot Water
Absorption Chiller uses an innovative two-step evaporator and
absorber design backed with an auxiliary cycle that is more
efficient than conventional cycles. By splitting the absorption
process into two steps, lithium-bromide solution concentrations
Cooling Co
are lower in the system, resulting in:
Water W
Higher system efficiency: Lower source hot-
Outlet In
water temperature into the generator can be used 7˚C (44˚F)
to drive the absorption cycle. 33˚C 27 Auxiliary
Upper Upper

Superior reliability: Virtually eliminates


Chilled Evaporator
(91˚F) (8
Absorber Absorber

Water 2
crystallization risk and reduces the potential Outlet
for corrosion.
Lower Lower
Evaporator Absorber
Low Temp.
Lower total operating cost: Can operate Generator

with lower hot water flow rates and reduced Chilled 12˚C (54˚F)
pumping energy.
Water
Inlet
AA
Solution Pump

The Most Flexible Refrigerant Pump

Operating Envelope
1
The YHAU-CL-DXS single-effect absorption chiller’s two- Solution
Circulation Pump
step design backed with an auxiliary cycle provides a wide
operating envelope utilizing waste heat as low as 55°C (131°F)
where competitive offerings cannot operate. 7˚C (44˚F) Low Temp.
Heat Exchanger

Condenser
Upper Upper Auxiliary
Single-effect double lift cycle with three generators
Chilled
(high-temperature generator, low-temperature generator
Evaporator Absorber Absorber

Water
and auxiliary generator) reduces hot water flow as a driving Chilled Water
Outlet
force. The large temperature difference can reduce total Cooling Water High Aux. Gen.
Temp.
system operation cost. Refrigerant Gen.

Hot Water Lower Lower


YORK® technology provides the flexibility to handle combined Evaporator Absorber
Diluted Solution Low Temp.
heat and power (CHP) systems, comfort or industrial-process High Concentrated Solution
Generator

Chilled 12˚C (54˚F)


cooling applications with outstanding efficiency and reliability. Auxiliary Diluted Solution
Water 1. Two-step evaporator and
Auxiliary Concentrated
absorber splits the absorption
2. G
 ravity-fed distribution
system for the evaporator/
Available YHAU-CL-DXS water temperature ranges
Inlet Solution
process into two steps, similar absorber employs stainless
WATER CHARACTERISTIC TEMPERATURE RANGE to how a series-counter-flow steel material that prevents
arrangement splits the work AA corrosion while ensuring
Entering cooling-water temperature As high as 37°C (98°F) Solution Pump
between two chillers. Therefore, consistent performance and
compared to conventional designs, long life.
Leaving chilled-water temperature As low as 4°C (39°F) the YHAU-CL-DXS absorption
Refrigerant Pump
cycle utilizes lower lithium-
Entering-hot-water temperature As low as 55°C (131°F) bromide solution concentrations
for increased efficiency and lower
Leaving-hot-water temperature As low as 40°C (104°F) cost of ownership.

Solution
Circulation Pump
Cooling Cooling YORK® YHAU-CL-DXS SINGLE-EFFECT
Water Water
Outlet Inlet DOUBLE LIFT HOT WATER ABSORPTION CHILLERS
Cooling Cooling
50 TO 1,250 TR Water
Water (176-4,395 kW)
33˚C 27˚C Outlet Inlet

(91˚F) (81˚F) 33˚C 27˚C


(91˚F) (81˚F)

Minimizing Total
Cost of Ownership
World-class YORK® engineering, support and
service reduce the cost of ownership by simplifying
4 startup and chiller operation over the life of the
Control Valve

7˚C (44˚F) system. Here’s how:


Condenser
Control Valve Upper Upper Auxiliary
Chilled Evaporator Absorber Absorber

Water
Outlet Fully automatic purging system provides High Aux. Gen.
Temp.

trouble-free operation by purging and


Gen.

Condenser Lower Lower


Evaporator Absorber

removing non-condensable gases without


Low Temp.
Generator

51˚C (123˚F)
Chilled 12˚C (54˚F)
operator intervention.
Water
High Aux. Gen. Hot Water Outlet
Inlet
Temp.
Gen. AA

Hot Water Inlet Solution Pump

Superior hermetic integrity is ensured by High Temp.


Heat Exchanger

95˚C (203˚F) high quality processes and rigorous helium leak


Refrigerant Pump

detection technique.
Auxiliary
Solution Heat Exchanger
Circulation Pump

Solution Spray
Tubes made with de-oxidized low phosphorus Pump

3 Low Temp.

(DLP) copper protect against corrosion cracking.


Heat Exchanger

High Temp.
Heat Exchanger
Water boxes are coated with epoxy paint for added
Chilled Water
corrosion resistance.
Cooling Water
Refrigerant
Auxiliary
Hot Water Control Center with graphical animated
Heat Exchanger Diluted Solution
LCD display lets the user see several operating
High Concentrated Solution
Solution Spray Auxiliary Diluted Solution parameters at once. Present and past operational
Pump
Auxiliary Concentrated status, data recording and chiller safeties are
Solution
accessible at a touch.

Isolation valves on the suction and discharge


of the solution and refrigerant pumps allow quick
and easy servicing of pumps, which typically have a
60,000-hour life.
3. H
 igh-efficiency plate heat  arallel flow design enables solution
5. P
exchanger provides increased flow to low-temperature generator
efficiency over conventional and high-temperature generator Marine-type water chamber case with hinges
shell and tube. simultaneously. This flow design ensures easy maintenance without removing the
allows an increase in the amount of
4. F
 alling-film generator design water piping around the chiller unit, reducing
recovered heat.
provides superior heat transfer maintenance cost.
compared to a conventional flooded  ouble lift cycle uses waste heat
6. D
generator. This design also reduces in three generators (high-temperature
the required amount of lithium- generator, low-temperature generator Factory functional testing on single-piece
bromide solution to be circulated, and auxiliary generator) to lower shipments, ensures control-panel and safety-device
decreasing startup time from a temperature more efficiently than
cold start. Stainless steel tubes are a conventional single-effect
operation to reduce on-site startup time in the field.
adopted to prevent stress corrosion absorption cycle.
cracking while intermediate tube
supports reinforce and extend unit life.
Why install anything but YORK®?
You want high performance. You expect efficiency. And you need a chiller that gives you confidence.

When your reputation is at stake, it’s smart to demand nothing less than YORK® technology and service. That’s because we provide
local service and parts to keep your equipment operating at peak performance year after year. Enjoy the peace of mind knowing that
trained service experts and Original Equipment Manufacturer parts are available from Johnson Controls – the largest HVAC service and
preventative maintenance organization in the world.

Johnson Controls, the Johnson Controls logo, YORK and Metasys are registered trademarks of Johnson Controls, Inc. in the United States of America
and other countries. Other trademarks used herein may be trademarks or registered trademarks of other companies.
©2017 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201. All rights reserved worldwide. Printed in USA PUBL-8691-A-0717.

FOR MORE INFORMATION VISIT JOHNSONCONTROLS.COM

You might also like