You are on page 1of 15

Assembly Thermal Resistance

Application
It is usually connected with display meter, recording
meter and computer, etc. to directly measure temperature
-200 500
of liquid, vapor, gas and solid surface ranging from -200
to 500 during various production process.

Features
1. 1.Spring thermal sensor with good shock-proof performance
2. 2.No compensational wire, spare cost
3.High measuring accuracy
3. ;
4.High mechanical strength, good pressure-resistant
4. ;
performance
5. ;
5.Imported film resistor with stable & reliable performance

Operation Theory
It is based on that temperature change of material
results in change of its resistance. When resistance value
changes, the working instrument will display relevant
temperature.

Main Technical Parameters


Executive Standard
IEC751 IEC751
JB/T8622-1997
JB/T8622-1997
JB/T8623-1997
JB/T8623-1997

Insulation Resistance at Normal Temperature


15~35 , 80%, The insulation resistance between electrode and
10~100v( ) protection tube of armored resistance shall be no less than
100M under condition that environment temperature is
100M
15~35 , relative humidity is no more than 80%, and testing
voltage is D. C. 10~100V.

Measuring Range & Tolerance

Measuring Tolerance
Type Graduation Accuracy
Range
A (0.15+0.002)ltl
WZP Pt100 -200 +500
B (0.30+0.005)ltl
Cu50 _
WZC -50 +100 (0.30+0.005)ltl
Cu100

Remarks: t is absolute value actually tested with thermal sensor.

84
Type Naming Method

W Temperature Instrument

Z Thermal Resistance

Thermal Element Material


Pt
P
Cu
C

Filament
blank Simplex
2 Duplex

Mounting & Fixing


1 1without Fixing Device
2 2 Threaded Connector

Temperature Sensor
3 3 Movable Flange
4 4 Fixed Flange
5 5 Elbow Tube Connector
6 6 Fixed Threaded Cone Connector
7 Straight Tube Connector
7
8 Fixed Threaded Tube Connector
8
9 Movable Threaded Tube Connector
9

Junction Box
2 2 Anti-spray Type
3 3 Water-proof Type

Protection Tube Diameter


0 Φ16 0 16
1 Φ 12 1 12

Measuring End
G G Variable Cross Section

W Z P 2 2 3 1 G Model Example

85
Type & Specification
Thermal Element

Name Type Graduation Measuring Specification


Range d L

310
Simplex WZP-101 Φ3 360
Pt Thermal Φ4
Resistance 410
Pt100 -200 500
Φ5 460
Φ6 510
WZP2-101
Duplex
Pt Thermal 560
Resistance

Wiring Method

Wiring Method (Simplex) Wiring Method (Duplex)

86
Thermal Resistance without Fixing Device

Measuring Thermal
Type Graduation Specification
Response
Range d L
Time

Temperature Sensor
WZP-120
90S
W Z P 2- 1 2 0
Φ16
WZP-120G
24S
W Z P 2- 1 2 0 G
WZP-121
W Z P 2- 1 2 1 45S
Φ12
WZP- 121G
24S 300
W Z P 2- 1 2 1 G 350
WZP- 130 400
Pt100 -200 500
W Z P 2- 1 3 0 90S 450
WZP- 130G Φ16 500
24S 550
W Z P 2- 1 3 0 G
650
WZP- 131 900
W Z P 2- 1 3 1 45S 1150
WZP- 131G Φ12 1650
W Z P 2- 1 3 1 G 24S 2150
WZC-120G 120S
WZC-120 40S
Φ16
WZC-130 120S
WZC-130G Cu50 40S
-40 100
WZC-121 Cu100 120S
WZC-121G 40S
Φ12
WZC-131 120S
WZC-131G 40S

1) Type 120, 121 for anti-spray type,protection class IP65;


1 120 121 IP65;
Type 130, 131 for water-proof type, protection class IP55;
130 131 IP55
2) Protection tube material is 1Cr18Ni9Ti, and we also produce the
2 1Cr18Ni9TI,
resistance with protection tube of other material.

87
Thermal Resistance with Threaded Connector

Measuring Thermal
Type Graduation Specification
Response
Range d L l
Time
WZP-220
90S
W Z P 2- 2 2 0
Φ16
WZP-220G
24S
WZP 2 -220G
WZP-221
45S
W Z P 2- 2 2 1
Φ12
WZP- 221G
24S 300 50
WZP 2 -221G 350 00
WZP- 230 400 50
W Z P 2- 2 3 0 Pt100 -200 500 90S 450 00
Φ16 500 50
WZP- 230G
24S 550 00
WZP 2 -230G
650 00
WZP- 231 900 50
W Z P 2- 2 3 1 45S 1150 000
Φ12 1650 500
WZP- 231G
WZP 2 -231G 24S 2150 000
WZC-220G 120S
WZC-220 40S
Φ16
WZC-230 120S
WZC-230G 40S
Cu50
WZC-221 -40 100 120S
Cu100
WZC-221G 40S
Φ12
WZC-231 120S
WZC-231G 40S

1 220 221 IP65 1) Type 220, 221 for anti-spray type, protection class IP65;
230 231 IP55 Type230, 231 for water-proof type, protection class IP55;
2 1Cr18Ni9TI, 2) Protection tube material is 1Cr18Ni9Ti, and we also produce the
3 10MPa resistance with protection tube of other material;
3) Nominal Pressure 10Mpa.

88
Thread Specification
d
Model Type
Code
WZP-230 M27 2

WZP-230A A G3/4 16

WZP-230C C NPT3/4

WZP-231G M27 2

WZP-231GA A G3/4 12

C NPT3/4
WZP-231GC

Temperature Sensor

89
Thermal Resistance with Movable Flange

Graduation Measuring Range Thermal Response Specification


Type
Time d L
WZP-320
90S
W Z P 2- 3 2 0
16
WZP-320G
24S
WZP 2 -320G
WZP-321
45S
W Z P 2- 3 2 1
12
WZP- 321G
24S 300
WZP 2 -321G 350
WZP-330 400
W Z P 2- 3 3 0 Pt100 -200 500 90S 450
16 500
WZP- 330G
24S 550
WZP 2 -330G
650
WZP- 331 900
W Z P 2- 3 3 1 45S 1150
12 1650
WZP- 331G
WZP 2 -331G 24S 2150
WZC-320G 120S
WZC-320 40S
16
WZC-330 120S
WZC-330G 40S
Cu50
WZC-321 -40 100 120S
Cu100
WZC-321G 40S
12
WZC-331 120S
WZC-331G 40S

1 320 321 IP65 1) Type 320, 321 for anti-spray type, protection class IP65;
330 331 IP55 Type 330, 331 for water-proof type, protection class IP55;
2 1Cr18Ni9Ti, 2) Protection tube material is 1Cr18Ni9Ti, and we also produce the
resistance with protection tube of other material.

90
Thermal Resistance with Fixed Flange

Measuring Thermal
Type Graduation Specification
Response

Temperature Sensor
Range d L I
Time
WZP-420
90S
W Z P 2- 4 2 0
16
WZP-420G
24S
W Z P 2- 4 2 0 G
WZP-421
45S
W Z P 2- 4 2 1
12
WZP- 421G
24S 300 50
W Z P 2- 4 2 1 G 350 00
WZP- 430 400 50
W Z P 2- 4 3 0 Pt100 -200 500 90S 450 00
16 500 50
WZP- 430G
24S 550 00
W Z P 2- 4 3 0 G
650 00
WZP- 431 900 50
W Z P 2- 4 3 1 45S 1150 000
12 1650 500
WZP- 431G
W Z P 2- 4 3 1 G 24S 2150 000
WZC-420G 120S
WZC-420 40S
16
WZC-430 120S
WZC-430G 40S
Cu50
WZC-421 -50 100 120S
Cu100
WZC-421G 40S
12
WZC-431 120S
WZC-431G 40S

1 420 421 IP65 1) Type 420, 421 for anti-spray type, protection class IP65;
430 431 IP55 Type 430, 431 for water-proof type, protection class IP55;
2 1Cr18Ni9TI, 2) Protection tube material is 1Cr18Ni9Ti, and we also produce the
3 2.5MPa resistance with protection tube of other material;
3) Nominal Pressure 2.5Mpa

91
Flange Specification

Model Type
D D1 D2 H d

WZP-420 105 75 55
16 16
WZP-420G 105 75 55

WZP-421 105 75 55
16 12
WZP-421G 105 75 55

p161 We may provide other flange as user s demand;PLS see more from P 161

92
Thermal Resistance with Fixed Threaded Cone Connector

Thermal Response Specification


Type Graduation Measuring Range
Time d L I

Temperature Sensor
WZP-620
90S
W Z P 2- 6 2 0
WZP-620A
24S
WZP 2-620A 300 150
Pt100 -200 500
WZP-630 350 200
45S 400 250
W Z P 2- 6 3 0
15 450 300
WZP- 630A
24S 500 350
WZP 2-630A 550 400
WZC-620 120S 650 500
WZC-620A Cu50
-50 100 40S
WZC-630 Cu100
120S
WZC-630A 40S

1 620 621 IP65 1) Type 620, 621 for anti-spray type,protection class IP65;
630 631 IP55 Type 630, 631 for water-proof type, protection class IP55;
2 1Cr18Ni9Ti, 2) Protection tube material is 1Cr18Ni9Ti, and we also produce the
3 30MPa resistance with protection tube of other material.
3) Nominal Pressure 30Mpa

Thread Specification
Model Type Code M
WZP-620 M33 2
WZP-620 A NPT1
WZP-630 M33 2
WZP-630A A NPT1

93
Thermal Resistance with Elbow Tube Connector

Specification
Type Graduation Measuring Range Connection Size
d L I
W Z P - 5 2 245
M20 1.5
W Z P 2- 5 2 Φ3 270
WZP-52A Φ4 295
NPT1/2
W Z P 2- 5 2 A Φ5 345
Pt100 -200 500
W Z P - 5 3 Φ6 395
M20 1.5
W Z P 2- 5 3 Φ8 445
WZP- 53A 545
W Z P 2- 5 3 A NPT1/2
645
W Z C - 5 2 M20 1.5
Φ5 745
WZC-52A Cu50 NPT1/2
-50 100 Φ6 899
W Z C - 5 3 Cu100 M20 1.5
Φ8 1149
WZC-53A NPT1/2

1 53,53A IP55 1) Type 53, 53A for water-proof type, protection class IP55;
52,52A IP65 Type 52, 52A for anti-spray type, protection class IP65;
2 ,L , 2) Specification L is only for reference if no special indication, and
U ; insert length of thermocouple shall be size U of protection tube.
3 P198 3) PLS see P198 for more about protection tube.

94
Thermal Resistance with Straight Tube Connector

Type Graduation Measuring Range Thermal Response Specification


Time d L I

Temperature Sensor
WZP-72 245
M20 1.5
W Z P 2- 7 2 Φ3 270
WZP-72A Φ4 295
NPT1/2
W Z P 2- 7 2 A Φ5 345
Pt100 -200 500
WZP-73 Φ6 395
M20 1.5
W Z P 2- 7 3 Φ8 445
WZP- 73A 545
W Z P 2- 7 3 A NPT1/2
645
WZC-72 M20 1.5
Φ5 745
WZC-72A Cu50 NPT1/2
-50 100 Φ6 899
WZC-73 Cu100 M20 1.5
Φ8 1149
WZC-73A NPT1/2

1 73,73A IP55 1) Type 73, 73A for water-proof type, protection class IP55;
72,72A IP65 Type 72, 72A for anti-spray type, protection class IP65;
2 ,L , 2) Specification L is only for reference if no special indication, and
U ; insert length of thermocouple shall be size U of protection tube.
3 P198 3) PLS see P198 for more about protection tube.

95
Thermal Resistance with Fixed Threaded Tube Connector

Type Graduation Measuring Range Connection Size Specification


d L I
WZP-82 245
M20 1.5
W Z P 2- 8 2 Φ3 270
WZP-82A Φ4 295
NPT1/2
WZP 2 -82A Φ5 345
Pt100 -200 500
WZP-83 Φ6 395
M20 1.5
W Z P 2- 8 3 Φ8 445
WZP- 83A 545
NPT1/2
WZP 2 -83A 645
WZC-82 M20 1.5
Φ5 745
WZC-82A Cu50 NPT1/2
-50 100 Φ6 899
WZC-83 Cu100 M20 1.5
Φ8 1149
WZC-83A NPT1/2

1 83,83A IP55 1) Type 83, 83A for water-proof type, protection class IP55;
82,82A IP65 Type 82, 82A for anti-spray type, protection class IP65;
2 ,L , 2) Specification L is only for reference if no special indication, and
U ; insert length of thermocouple shall be size U of protection tube.
3 P198 3) PLS see P198 for more about protection tube.

96
Thermal Resistance with Movable Threaded Tube Connector

Measuring Thermal Specification


Type Graduation
Range Response Time d L I

Temperature Sensor
WZP-92 245
M20 1.5
W Z P 2- 9 2 Φ3 270
WZP-92A Φ4 295
NPT1/2
W Z P 2- 9 2 A Φ5 345
Pt100 -200 500
WZP-93 Φ6 395
M20 1.5
W Z P 2- 9 3 Φ8 445
WZP- 93A 545
W Z P 2- 9 3 A NPT1/2
645
WZC-92 M20 1.5
Φ5 745
WZC-92A Cu50 NPT1/2
-50 100 Φ6 899
WZC-93 Cu100 M20 1.5
Φ8 1149
WZC-93A NPT1/2

1 93,93A IP55 1) Type 93, 93A for water-proof type, protection class IP55;
92,92A IP65 Type 92, 92A for anti-spray type, protection class IP65;
2 ,L , 2) Specification L is only for reference if no special indication, and
U ; insert length of thermocouple shall be size U of protection tube.
3 P198 3) PLS see P198 for more about protection tube.

97
Explosion-proof Thermal Resistance

Application

It is usually connected with display meter, recording


meter and computer, etc. to directly measure temperature
200 500 of liquid, vapor, gas and solid surface ranging from -200
to 500 with exploxives such as hydrocarbon on
production spot.

Features
1. ; 1.Spring thermal element with good shock-proof
2. ; performance;
3. ; 2.High measuring accuracy;
3.No compensational wire, spare cost;
4. , ;
4.Imported film resistor with high reliability and stability

Operation Theory
Explosion-proof thermal resistance has a junction box of
enough strength with gaps inside it. All spare parts which
might produce spark, electric arc, and dangerous high
temperature are sealed in the junction box. When explosion
within the box happens, fire and high temperature caused by
explosion could be extincted and cooled. Thus, explosion
separation could be realized.
Main Technical Parameters
Executive Standard
IEC751
IEC751
JB/T8622-1997
JB/T8622-1997 JB/T8623-1997
JB/T8623-1997 JB/T5518-1991
JB/T5518-1991

Insulation Resistance at Normal Temperature


15~35 The insulation resistance between electrode and pro-
80% 10~100V tection tube of the thermocouple shall be no less than 100M
100M under condition that environment temperature is 15~35
, relative humidity is no more than 80%, and testing voltage
is D. C. 10~100V.

Measuring Range & Tolerance

Measuring Accuracy
Type Graduation Tolerance
Range
A (0.15+0.002)ltl
WZP Pt100 -200 +500
B (0.30+0.005)ltl
Cu50 _
WZC -50 +100 (0.30+0.005)ltl
Cu100
t Remarks: t is absolute value actually tested with thermal sensor.