In a practical way we say that when two teeth are dull based on touch and vision, you should replace the cam. This is
really easy to determine, as people who inspect & test lifting equipment can easily feel when teeth are dull or worn
out.
Also if you compare this visually with the good teeth you can easily spot the difference. Please check the image
examples below.
For the pivot we advice to replace this when more than 50 % of one ring is dull.
1
2
Best regards / Mit freundlichen Grüßen / Met Vriendelijke Groet,
Maykel Polderman
__________________________
Terrier Lifting Clamps B.V.
NL-4338 PV Middelburg, Ohmweg 11
Phone: +31 1186517 - 17
Fax: +31 1186517 - 18
terrier@terrierclamps.com, www.terrierclamps.com
3
Before printing this email, please consider the environment
Confidentiality Notice: This message including any attachments contains information to be deemed strictly
confidential and is destined only to the addressee(s) identified above who may copy and, under his/her/their
responsibility, further disseminate it. Anyone who received this message by mistake or reads it without entitlement is
forewarned that keeping, copying, disseminating or distributing this message to persons other than the addressee(s)
is strictly forbidden and is asked to transmit it immediately to the sender and to erase the original message received.
Dear
Thank you very much on your instruction documentation. Could you advise me the method how to
measure the wearing of teeth as below ?
Do we have any means how to define the limit of wear/ dull of teeth to compare with the criterion ?
4
Best regards,
____________________________
Maintenance Department
Vard Vung Tau Ltd
+84 254
Direct:
3616 611
5
The data contained in this email may be confidential and/or privileged and is only for the person or entity to
which it is addressed. Any use of this data by other than the intended recipient is prohibited. If you receive
this email in error please contact the sender and delete the material from any computer.
From: Maykel Polderman [mailto:mpolderman@terrierclamps.com] On Behalf Of TERRIER
Sent: Tuesday, February 25, 2020 7:08 PM
To: Dao, Tran Thy <tran.thy.dao@vard.com>
Cc: Gerry Giang | S.R.C (Rope, Rigging, Liftings) <gerrygiang@src-rigging.com.vn>; Van, Huynh Thi Ha
<huynh.thi.ha.van@vard.com>; Ngoc Thao | S.R.C <ngocthao@src-rigging.com.vn>; Khanh, Pham Van
<pham.van.khanh@vard.com>
Subject: Betr: RE: Betr: RE: Terrier clamp -NC
Goodafternoon,
Please find attached a checklist with more details about the teeth and other criteria.
Maykel Polderman
__________________________
Terrier Lifting Clamps B.V.
NL-4338 PV Middelburg, Ohmweg 11
Phone: +31 1186517 - 17
Fax: +31 1186517 - 18
terrier@terrierclamps.com, www.terrierclamps.com
6
rigging.com.vn>, "Khanh, Pham Van" <pham.van.khanh@vard.com>
Datum: 25-02-2020 09:18
Onderwerp: RE: Betr: RE: Terrier clamp -NC
Regarding to our tool ‘’vertical lifting clamp TSE. Could you clarify me about how to inspect the cam and
pivot teeth condition? I have found in the maintenance instruction that’’ the cam and/ or pivot teeth are
no longer sharp’’ how can we evaluate it about this sharp, any criteria for reference? Thanks!
Best regards,
____________________________
7
Dao Tran Thy
Maintenance
Manager
Maintenance Department
Vard Vung Tau Ltd
+84 254
Direct:
3616 611
The data contained in this email may be confidential and/or privileged and is only for the person or entity to
which it is addressed. Any use of this data by other than the intended recipient is prohibited. If you receive
this email in error please contact the sender and delete the material from any computer.
From: Maykel Polderman [mailto:mpolderman@terrierclamps.com] On Behalf Of TERRIER
Sent: Monday, November 11, 2019 4:18 PM
To: Dao, Tran Thy <tran.thy.dao@vard.com>
Cc: Gerry Giang | S.R.C (Rope, Rigging, Liftings) <gerrygiang@src-rigging.com.vn>; Van, Huynh Thi Ha
<huynh.thi.ha.van@vard.com>; Ngoc Thao | S.R.C <ngocthao@src-rigging.com.vn>; Khanh, Pham Van
<pham.van.khanh@vard.com>
Subject: Betr: RE: Terrier clamp -NC
The clamps in the picture are older than 6 years. In 2013 we have changed the design of the pads.
For us this is already an indicator that this clamp has been used for a while. (also the lock lever is
missing? - which is not a common replace part)
If we look at the pictures, we can see that the housing of the clamp is probably deformed as well.
Also these pads are not glued, but casted on the steel. If the clamp is overloaded the force will pull
the plastic from the pads.
Therefore we can say that judged on this picture this clamp has been overloaded and cannot be
used or repaired in any way.
Please stop using the clamp and make the clamp unfit for further use .
Maykel Polderman
__________________________
8
Terrier Lifting Clamps B.V.
NL-4338 PV Middelburg, Ohmweg 11
Phone: +31 1186517 - 17
Fax: +31 1186517 - 18
terrier@terrierclamps.com, www.terrierclamps.com
Dear Supplier,
Regarding to the NON-MARKING CLAMP that you have supplied. We have discussed with you about the
outer part of push plate are very easy loosen out during short used time.
Could you find out the attached files for the NCR of your products that we would like to have your advice
and corrective action as soon as possible ?
We have ordered replacement of this parts but the root causes are not clarifying yet I believed that you are
a supplier for this part you have to know how to improve and issue the correction action to us very soon.
Since the safety of tool very importance for our production, we will not use the tool that can alternate
many risks for us during using.
Thanks!
9
Best regards,
____________________________
Maintenance Department
Vard Vung Tau Ltd
+84 254
Direct:
3616 611
The data contained in this email may be confidential and/or privileged and is only for the person or entity to
which it is addressed. Any use of this data by other than the intended recipient is prohibited. If you receive
this email in error please contact the sender and delete the material from any computer.
From: Gerry Giang | S.R.C (Rope, Rigging, Liftings) [mailto:gerrygiang@src-rigging.com.vn]
Sent: Thursday, October 10, 2019 9:14 AM
To: Dao, Tran Thy <tran.thy.dao@vard.com>
Cc: Van, Huynh Thi Ha <huynh.thi.ha.van@vard.com>; Khanh, Pham Van <pham.van.khanh@vard.com>;
Ngoc Thao | S.R.C <ngocthao@src-rigging.com.vn>
Subject: Re: Terrier clamp
t ti c ã x y ra tình tr ng bong mi ng cao su lót ra nh anh thông báo. SRC s báo l i Terrier
ngay và tìm cách kh c ph c. Tr c m t, kh c ph c v n t m lót cao su, anh vui lòng cho
bi t s l ng c n thay th cho t ng model 1.5 TNMK và 3 TNMK.
m n anh.
Regards,
Gerry Giang
VP Sales & Marketing
Cell: +84-90 3993 716
10
SRC Maritime Mechanical Co., Ltd.
(Quality Ropes, Slings & Lifting Products)
Block A-10b, Hiep Phuoc Industry Park, Nha Be District,
Ho Chi Minh City, Vietnam
Tel: +(84-28) 3512 4970 / 71 / 72 (3 lines)
Fax: +(84-28) 3512 4915
Email: gerrygiang@src-rigging.com.vn
Website: www.src-rigging.com.vn
Dear Supplier,
m n!
11
Best regards,
____________________________
+84 254
Direct:
3616 611
12
Vard Vung Tau Ltd
The data contained in this email may be confidential and/or privileged and is only for the person or entity to