FEATURES: @ Maintains satisfactory operation over a +£10% range in bus voltage. ¢ Provides accuracy of 5% of full generator KVAR rating. © Operates on 120 or 208 volt sensing circuits. @ Provides smooth “walk-in” when adding generators to the bus. © Advanced solid-state circuitry. © Dither control provided to overcome motor stiction © No electrolytic capacitors. © Mechanically rugged. ‘© Withstands 15G's shock in any plane. © Available from stock. cP Bo eet ‘Signal Sha Tbe Power FIGURE 1—APPLICATION DIAGRAM EP SCP 240 KVAR CONTROLLER APPLICATION: The Basler Model SCP 240 KVAR Controller provides unattended KVAR control during parallel operation of a generator-prime mover ina peaking application. & typical peaking application is illustrated pictorially in Figure 1 and schematically in Figure 2. Note that use of the SCP 240 is unnecessary in an isolated bus application when using Basler voltage regulators and the reactive differential com: pensation (parallel cross current compensation) interconnecting loop. In such an isolated bus system KVAR load division is obtained automatically. DESCRIPTIOI ‘The SCP 240 KVAR Controller senses generator output voltage and current and, based upon these inputs, provides an output toa motor ‘operated control (MOC) to raise or lower the voltage regulator set point, Generator field excitation is correspondingly changed to ‘obtain the desired KVAR load. The SCP 240 can be preprogrammed to take on the desired KVAR load. A dither circuit with an adjustable output level is provided to overcome the motor stiction by gently pulsing the motor-operated control. When only minor KVAR cor- rections are required, the KVAR Controller supplies @ reduced voltage to the MOC to minimize motor stress. The unit is designed for be- hind:the-panel mounting. ‘aster Motor operates Contot ‘spe Voit euiatot “Sa Yotase sensing Sed insat Pome Basler Electric , Highland, Illinois ‘SPECIFICATIONS: © INPUT POWER: 120 oF 208 10%, Frequency. .50/60 Hertz Phase... Three Burden, : 14VA per phase Current Sensing Current. -3-5 Amperes. Withstands up to 15 amps for 30 seconds without failure. Phase. Single or three Burden ‘3VA per phase Power Volta ++120 or 208 10% Frequency. Seo 8Q/60 Hertz Phase... «Single Burden. 80 VA # OUTPUT: 0 to £0 Volts to the motor operated control ‘at nominal input voltage and frequency. Current .6A max. © TEMPERATURE: Operates within 40°C (—40°F) to +70°C (+158°F). ‘© VIBRATION: Withstands 1.3 G's from § to 26 Hz, 036 D. A. from 26 to 52 Hz, and 5 G's from 52 to 260 Hz without damage or degradation of performance. perature range of meats FIGURE 2—TYPICAL INTERCONNECTION DIAGRAM— PEAKING APPLICATION. Note: This drawing NOT intended fr iatllation purposes eter OPERATION MANUAL ‘© SHOCK: Withstands 15 G's in each of three mutually perpendicular axes. ‘@ MOUNTING: Behind-the-panel ark brown, lusterless, textured, baked. © WEIGHT: 22 pounds net, 24 pounds shipping HOW TO ORDER: Specify Basler Electric Company Model SCP 240 KVAR Controlier. Please provide the following information when ordering Example Input sensing voltage (1.20 or 208 volts 3 ). -120v Power input voltage (220 or 208 volts 1 9 ). “120 Currant sensing Single or three phiase)...Single Phase PT rat eee 35/1 CT ratio. 50/1 Full load line current and P-F.. Generator KW rating... Generator voltage and frequency... 174A @0.8P-F. ---1000 KW A16OV @ 60 Hz. Basler Electric . Highland, Illinois PHONE 618-654-2341 BOX 269 HIGHLAND, ILLINOIS 6224:

You might also like