You are on page 1of 40

DSC-V1

Ver 1.0 2003. 05 SECTION 6 ADJ


Revision History ADJUSTMENTS

Link
Before starting adjustments SERVICE MODE
Adjusting items when replacing main parts and boards APPLICATION FOR ADJUSTMENT (SEUS)

DATA PROCESS
CAMERA SECTION ADJUSTMENTS
SERVICE MODE
PREPARATIONS BEFORE ADJUSTMENTS

INITIALIZATION OF 0E, 2F, 4F, 6F PAGE DATA

VIDEO SYSTEM ADJUSTMENTS

CAMERA SYSTEM ADJUSTMENTS

LCD SYSTEM ADJUSTMENTS

Contents of LEVEL 2 and LEVEL 3 Service Manual


CONTENTS LEVEL 2 LEVEL 3
1. SERVICE NOTE a ✕
2. DISASSEMBLY a ✕
3. BLOCK DIAGRAMS OVERALL ✕
POWER
4. PRINTED WIRING BOARDS AND CD-441, ST-083, SW-395, SY-089, DD-195
SCHEMATIC DIAGRAMS JK-254, MS-165, BB-004,
FU-165
5. REPAIR PARTS LIST EXPLODED VIEWS ✕
ELECTRICAL PARTS a
(DD-195, SY-089)

2003E0500-1
©2003.5
9-876-261-51 Sony EMCS Co. Published by DI Customer Center
DSC-V1

TABLE OF CONTENTS
Section Title Page Section Title Page
6. ADJUSTMENTS 6-2. Service Mode ································································· 6-31
Before starting adjustment ························································· 6-1 2-1. Application for Adjustment (SEUS) ······························ 6-31
1-1. Adjusting Items when Replacing 2-1-1. Using Method of SEUS ················································· 6-31
Main Parts and Boards ···················································· 6-2 1. Connection ····································································· 6-31
6-1. Camera Section Adjustments ··········································· 6-3 2. Operation ······································································· 6-31
1-1. Preparations Before Adjustments ···································· 6-3 2-1-2. Precaution on Use of SEUS ··········································· 6-31
1-1-1. List of Service Tools ························································ 6-3 2-2. Data Process ·································································· 6-32
1-1-2. Preparations ····································································· 6-4 2-3. Service Mode ································································· 6-32
1-1-3. Precautions ······································································ 6-5 1. Setting the Test Mode ···················································· 6-32
1. Setting the Switch ···························································· 6-5 2. Bit Value Discrimination ··············································· 6-33
2. Order of Adjustments ······················································ 6-5 3. LED Check ···································································· 6-33
3. Subjects ··········································································· 6-5 4. Jog Dial Check ······························································ 6-33
4. Preparing the Flash Adjustment Box ······························· 6-6 5. Switch Check (1) ··························································· 6-33
1-2. Initialization of 0E, 2F, 4F, 6F Page Data ······················· 6-7 6. Switch Check (2) ··························································· 6-34
1-2-1. Initialization of 0E, 2F, 4F, 6F Page Data ······················· 6-7 7. Mode Dial Check (1) ····················································· 6-34
1. Initializing 0E, 2F, 4F, 6F Page Data ······························· 6-7 8. Mode Dial Check (2) ····················································· 6-35
2. 0E Page table ··································································· 6-7 9. Self Diagnosis Code ······················································ 6-35
3. 2F Page table ··································································· 6-7
4. 4F Page table ··································································· 6-7
5. 6F Page Table ·································································· 6-8 * The sheet for auxiliary light is shown on page 6-36.
1-3. Video System Adjustments ············································ 6-11 * The color reproduction frame is shown on page 6-37.
1. Composite Video Level Adjustment ······························ 6-11
1-4. Camera System Adjustments ········································· 6-12
Data Setting During Camera System Adjustments ········ 6-12
Picture Frame Setting ···················································· 6-13
1. Flange Back Adjustment
(Using the minipattern box) ·········································· 6-14
2. Flange Back Check ························································ 6-15
3. F No. Compensation ······················································ 6-15
4. Mechanical Shutter Adjustment ···································· 6-16
5. Light Value Adjustment ················································· 6-16
6. Mixed Color Cancel Adjustment ··································· 6-17
7. AWB 3200K Standard Data Input ································· 6-17
8. AWB 5800K Standard Data Input ································· 6-18
9. AWB 5800K Check ······················································· 6-18
10. AWB 3200K Check ······················································· 6-19
11. CCD Linearity Check ···················································· 6-19
12. Color Reproduction Adjustment ···································· 6-21
13. CCD White Defect Compensation ································ 6-22
14. CCD Black Defect Compensation ································· 6-23
15. Strobe Adjustment ························································· 6-24
16. Hologram AF Data Input ··············································· 6-25
17. Hologram AF Angle Check ··········································· 6-26
1-5. LCD System Adjustments ············································· 6-27
1. LCD Initial Data Input ·················································· 6-27
2. VCO Adjustment (SY-089 Board) ································· 6-27
3. Bright Adjustment (SY-089 Board) ······························· 6-28
4. Contrast Adjustment (SY-089 Board) ···························· 6-28
5. Black Limit Adjustment (SY-089 Board) ······················ 6-29
6. V-COM Adjustment (SY-089 Board) ···························· 6-29
7. White Balance Adjustment (SY-089 Board) ················· 6-30

—2—
DSC-V1
SECTION 6
COVER ADJUSTMENTS

Before starting adjustment

EVR Data Re-writing Procedure When Replacing Board


The data that is stored in the repair board, is not necessarily correct.
Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a
board is replaced.

(Machine before starting repair) PC PC (Machine after a board is replaced)

Save the EVR data Download the saved


to a personal computer. data to a machine.

Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM
to the replaced board.

Remove the EEPROM and install it.

(Former board) (New board)

Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or in-
stalled, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)

Download the data.

Save the data.

(The same model of the same destination)

After the EVR data is saved and downloaded, check the


respective items of the EVR data.
(Refer to page 6-2 for the items to be checked.)

6-1
DSC-V1

COVER

1-1. Adjusting items when replacing main parts and boards


When replacing main parts and boards, adjust the items indicated by z in the following table.

Replaced parts
Block Mounted parts Board
replacement replacement replacement

(Camera DSP, 256M SDRAM)

(LCD drive, Timing generator)


(Camera module)

(VIDEO AMP)
(CCD imager)
(LCD panel)
(Back light)

(Laser unit)

EEPROM
(EVR)

(COMPLETE)

(COMPLETE)
Adjustment section Adjustment

Flash unit
LCD901

IC101
IC152
IC304
IC601
IC101
IC801

IC502
D901

D333
ST-083 flexible board
ST-083 flexible board

ST-083 flexible board


Lens block assy

CD-441 board
SY-089 board
SY-089 board
SY-089 board
SY-089 board
SY-089 board

SY-089 board

SY-089 board
LCD block
LCD block

Initialization of 0E, 2F, Initialization of 0E, 2F, 4F,


z z
4F, 6F page data 6F page data
Video Composite video level adj. z z z z
Camera Flange back adj. z z z z
F No. compensation z z z z z
Mechanical shutter adj. z z z z z z
Light value adj. z z z z z
Mixed color cancel adj. z z z z z
AWB 3200K
z z z z z
standard data input
AWB 5800K
z z z z z
standard data input
CCD linearity check z z z z
Color reproduction adj. z z z z
CCD (white and black)
z z z
defect compensation
Strobe adj. z z z z z z
Hologram AF data input z z z z z z
LCD LCD initial data input z z
VCO adj. z z z
Bright adj. z z z
Contrast adj. z z z
Black limit adj. z z z
V-COM adj. z z z z
White balance adj. z z z z z

Table 6-1-1

6-2
DSC-V1

COVER

6-1. CAMERA SECTION ADJUSTMENTS

1-1. PREPARATIONS BEFORE ADJUSTMENTS


1-1-1. List of Service Tools
• Oscilloscope • Color monitor • Vectorscope
• Regulated power supply • Digital voltmeter
• Calculating machine capable of calculating hexadecimal numbers.
Ref. No. Name Parts Code Usage
Auto white balance adjustment/check
J-1 Filter for color temperature correction (C14) J-6080-058-A
White balance adjustment/check
J-2 Pattern box PTB-450 J-6082-200-A
J-3 Color bar chart for pattern box J-6020-250-A
J-4 Siemens star chart J-6080-875-A For checking the flange back
J-5 Clear chart for pattern box J-6080-621-A
OS: Windows 98/98SE/Me/2000/XP Home/XP Pro
J-6 Personal computer
USB connector × 2
J-7 USB cable 1-823-932-11 For connecting the camera to PC
HASP key and application for adjustment Contact our service headquater of each area how to get
J-8
(SEUS) the application for adjustment (SEUS) and HASP key
J-9 Minipattern box J-6082-353-B For adjusting the flange back
J-10 Back ground paper J-2501-130-A For adjusting the strobe

J-1 J-2 J-3 J-4 J-5

J-6 J-7 J-8 J-9 J-10

and application for


adjustment (SEUS)

Fig. 6-1-1

6-3
DSC-V1

1-1-2. Preparations
Pattern box
1) Connect the equipment for adjustments according to Fig. 6-1-3.
2) Start up the application for adjustment (SEUS).

Front of the lens

L = About 25 cm

Fig. 6-1-2

PC with USB connectors (x 2)


(Windows 98/98SE/ME/2000/XP)

To USB connector USB cable


(1-823-932-11) To USB connector
DSC- V1

HASP Key
To USB connector
To A/V OUT jack
Vectorscope Color monitor
Terminated Video (yellow)
75 Ω
To DC IN jack
Audio (Black)

AC power adaptor Insert the Memory Stick.


AC IN LOCK

Fig. 6-1-3

6-4
DSC-V1

1-1-3. Precautions
1. Setting the Switch
Unless otherwise specified, set the switches as follows and per-
form adjustments.
1. Mode Dial ................................................. CAMERA
2. ZOOM button
(MODE-51470 block S101, S105) ........... WIDE end
3. DSPL/LCD ON/OFF button
(GL-51470 block S258) ............................ OSD OFF
4. SMART ZOOM (SET UP setting) ........... OFF
5. VIDEO OUT (SET UP setting) ................ NTSC

2. Order of Adjustments
Basically carry out adjustments in the order given.

Color bar chart (Standard picture frame)


Electronic beam scanning frame
H
Yellow

Magenta
White
Cyan
Green

C C=D D
Red
Blue

Magenta
Yellow

Green
White
Cyan

Blue
Red
CRT picture frame

V
A B A=B B A
Fig. b (monitor TV picture)
Enlargement

Difference in level
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig a
and the monitor TV display shown in Fig. b.

B A

Fig. 6-1-4

3. Subjects
1) Color bar chart (Standard picture frame).
When performing adjustments using the color bar chart, ad-
just the picture frame as shown in Fig. 6-1-4. (Standard pic-
ture frame)
2) Clear chart (Standard picture frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations dur-
ing this time)

6-5
DSC-V1

4. Preparing the Flash Adjustment Box


A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;

1) Provide woody board A, B and C of 15 mm thickness.


Dimensions without brackets are for a box of 1 m in depth.
Dimensions in brackets are for a box of 50 cm in depth.

woody board A (2) woody board B (2) woody board C (1)


530 mm 500 mm 1000 mm
(400 mm) (370 mm) (700 mm)

1026 mm 1026 mm 1000 mm


(513 mm) (513 mm) (700 mm)

1030 mm 1000 mm
(730 mm) (700 mm)

Fig. 6-1-5

2) Apply black mat paint to one side of woody board A and B.


3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig 6-1-6)

woody board A

woody board B

woody board A

woody board B

woody board C

Fig. 6-1-6

6-6
DSC-V1

COVER

1-2. INITIALIZATION OF 0E, 2F, 4F, 6F PAGE 2. 0E Page table


DATA Note 1: Fixed data-1: Initialized data.
(Refer to step 5 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
1-2-1. Initialization of 0E, 2F, 4F, 6F Page Data Data”)
1. Initializing 0E, 2F, 4F, 6F Page Data Note 2: Fixed data-2: Modified data.
Note 1: Initialize the data every page of 0E, 2F, 4F, and 6F. (Refer to step 7 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Note 2: If the 4F page data has been initialized, the following Data”)
adjustments need to be performed again. Address Initial value Remark
1) Video system adjustment
2) LCD system adjustments 00 to FF Fixed data-1 (Initialized data)
Note 3: If the 6F page data has been initialized, the following
adjustments need to be performed again.
1) Camera system adjustments 3. 2F Page table
Note 1: Fixed data-1: Initialized data.
Adjusting Page 0E (Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Adjusting Address 00 to FF Note 2: Fixed data-2: Modified data.
Adjusting Page 2F (Refer to step 7 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Adjusting Address 00 to 7F Data”)
Adjusting Page 4F Address Initial value Remark
Adjusting Address 00 to FF 00 to 20 Fixed data-1 (Initialized data)
Adjusting Page 6F 21 00 Test mode
Adjusting Address 00 to FF 22 to 7F Fixed data-1 (Initialized data)

Initializing Method:
1) Select page: 00, address: 01 and set data: 01. 4. 4F Page table
2) Click [Page Edit] on the SEUS screen to display the SEUS Note 1: Fixed data-1: Initialized data.
PAGE EDIT screen. (Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
3) Click [Page], and then enter the page to be initialized. Data”)
4) Click [Preset Data Read] to display the Set ID input screen. Note 2: Fixed data-2: Modified data.
5) For page 0E, enter Set ID = “00” and read the initializing data (Refer to step 7 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
on the SEUS PAGE EDIT screen. Data”)
6) For page 2F, 4F and 6F, enter Set ID = “09” and read the ini- Address Initial value Remark
tializing data on the SEUS PAGE EDIT screen.
00 to 81 Fixed data-1 (Initialized data)
7) On the SEUS PAGE EDIT screen, change the data at “Fixed
data-2” address given in the table on the page to be initialized. 82 90 VCO adj. (NTSC mode)
Note: New data for change are not listed in the table. If the 83 9B VCO adj. (PAL mode)
data are to be changed, read and copy the data from the
84 91 V-COM adj.
same model. Copying the data from different models
may cause an operation failure. 85 B2 Bright adj.
8) Confirm that the data at respective adjustment addresses are 86 2D Black limit adj.
the initial values (adjustment initial values) given in the table.
87 Fixed data-1 (Initialized data)
If different, change to the adjustment initial values.
9) Click [Write] to write the initializing data to the set. 88 84
White balance adj.
10) Click [Close] to close the SEUS PAGE EDIT screen. 89 66
8A 3F Contrast adj.
Processing after Completing Initializing
8B to 9F Fixed data-1 (Initialized data)
Order Page Address Data Procedure
A0 80 Composite video level adj.
1 20 00 29 [set]
A1 to A7 Fixed data-1 (Initialized data)
2 20 01 29 [Write] (Note)
A8
Fixed data-2
Note: At this time, the set is reset and the power is turns off once A9
and then on again. Accordingly, the message “Receive AA to FF Fixed data-1 (Initialized data)
Packet Error” is displayed on the SEUS screen, and the
SEUS goes in “disconnect” state, but this is not a trouble.
Click [Connect] on the SEUS screen to restore the “con-
nected” state. (In case that the power does not turn on again,
press the power button.)

6-7
DSC-V1

5. 6F Page Table
Note 1: Fixed data-1: Initialized data. Address Initial value Remark
(Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”) 3C 00
Note 2: Fixed data-2: Modified data. 3D 00 Flange back adj.
(Refer to step 7 of “ 1. Initializing of 0E, 2F, 4F, 6F Page 3E FF
Data”)
3F Fixed data-1 (Initialized data)
Address Initial value Remark
40 00
00 to 0F Fixed data-1 (Initialized data)
41 00
10 58
42 00
11 FF
43 00
12 FF Hologram AF data input
44 00
13 FF
45 00
14 00
46 00
15 to 17 Fixed data-1 (Initialized data)
47 00
18 4C
48 00
19 0F
49 00 Flange back adj.
1A AC
4A 00
1B CA
4B 00
1C 10
4C 00
1D 00
4D 00
1E 00
4E 00
1F 00
4F 00
20 00
50 00
21 00
51 00
22 00
52 00
23 00
53 00
24 20
54 00 Hologram AF data input
25 20
55 to 5F Fixed data-1 (Initialized data)
26 64
60 00
27 46
61 00
28 0A
62 00 F No. compensation
29 00 Flange back adj.
63 00
2A 00
64 00
2B 00
65 30
2C 00
66 FE Light value adj.
2D 00
67 6D
2E 00
68 to 6A Fixed data-1 (Initialized data)
2F 00
6B FF
30 00 F No. compensation
6C 00
31 00 Mechanical shutter adj.
6D 00
32 00
6E 00
33 00 Mixed color cancel adj.
6F 00
34 00
70 29
35 00
71 83
36 00
72 1F
37 00
73 DF
38 00 AWB 3200K standard data input
74 29
39 00
75 0C
3A 00
76 22
3B 00
77 6D

6-8
DSC-V1

6F Page Table
Address Initial value Remark Address Initial value Remark
78 00 A8 D5
79 00 A9 FE
7A 00 AA 73
7B 00 AB 45
Color reproduction adj.
7C 00 AC 63
7D 00 AD 83
7E 00 AE 03
7F 00 AF E9
AWB 3200K standard data input
80 00 B0 00 AWB 3200K standard data input
81 00 B1 00 AWB 5800K standard data input
82 00 B2 00 AWB 3200K standard data input
83 00 B3 00 AWB 5800K standard data input
84 00 B4 00 AWB 3200K standard data input
85 00 B5 Fixed data-1 (Initialized data)
86 00 B6 28
Strobe adj.
87 00 B7 6E
88 19 B8 10
89 66 B9 6B
8A 30 BA 0F
8B 6E BB F6
8C 19 BC 0F
8D A7 BD F7
8E 32 BE 0F
8F FB BF F2
90 00 C0 0F
91 00 C1 F7
92 00 C2 00
93 00 C3 00
94 00 C4 00
95 00 AWB 5800K standard data input C5 00
96 00 C6 00
97 00 C7 30 Mechanical shutter adj.
98 00 C8 1B
99 00 C9 12
9A 00 CA 0D
9B 00 CB 08
9C 00 CC 80
9D 00 CD 88
9E 00 CE 98
9F 00 CF 90
A0 2A D0 88
A1 7E D1 00
A2 5F D2 00
A3 81 D3 00
A4 03 D4 00
A5 E9 D5 00
Color reproduction adj.
A6 63 D6 00
A7 83 D7 14

6-9
DSC-V1

6F Page Table
Address Initial value Remark
D8 FF
D9 FF
DA FF
DB 00
DC 00
DD 00
DE 00
DF 00
E0 00
E1 00
E2 00
E3 00 Strobe adj.
E4 00
E5 00
E6 00
E7 00
E8 00
E9 00
EA 00
EB 00
EC 00
ED 00
EE 00
EF 00
F0 to FF Fixed data-1 (Initialized data)

6-10
DSC-V1

COVER

1-3. VIDEO SYSTEM ADJUSTMENTS


1. Composite Video Level Adjustment
Adjust the sync level of the composite video signal output and
check the burst level of the composite video signal output.
Mode PLAY
Signal Arbitrary
Measurement Point Video terminal of A/V OUT jack
(75 Ω terminated)
Measuring Instrument Oscilloscope
Adjustment Page 4F
Adjustment Address A0
Specified Value Sync level:
A = 286 ± 5 mV (NTSC mode)
A = 300 ± 5 mV (PAL mode)
Burst level:
B = 286 ± 30 mV (NTSC mode)
B = 300 ± 30 mV (PAL mode)

Adjusting method:
Order Page Address Data Procedure
1 00 01 01 [Set]
2 2F 21 08 [Write]
3 4F 0F 01 [Write]
4 4F 02 03 [Write]
5 60 C1 [Read] Check the data is “01”.
6 40 F1 04 [Set]
Change the data and set
7 4F A0 the sync level (A) to the
specified value.
8 4F A0 [Write] Write this data.
Check the burst level (B)
9
to the specified value.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 40 F1 00 [Set]
2 2F 21 00 [Write]
3 4F 02 00 [Write]
4 4F 0F 00 [Write]
5 00 01 00 [Set]

B
A

Fig. 6-1-7

6-11
DSC-V1

COVER

1-4. CAMERA SYSTEM ADJUSTMENTS After completing the camera system adjustments, release the
Before perform the camera system adjustments, check that the data setting:
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat- 1) Click [Page Edit] on the SEUS screen to display the SEUS
isfied. PAGE EDIT screen.
Note: For “CAMERA SYSTEM ADJUSTMENTS”, perform in 2) Click [Page], and then enter the page “0E”.
order of item numbers. 3) Click [Preset Data Read] to display the Set ID input screen.
4) Enter Set ID = “00” and read the initializing data on the SEUS
Data setting during camera system adjustments PAGE EDIT screen.
Perform the following data setting before the camera system ad- 5) Check that all the data is “FF”.
justments. 6) Click [Write] to write the initializing data to the set.
It is not necessary to perform the following data setting every time 7) Click [Close] to close the SEUS PAGE EDIT screen.
when you perform some items of camera system adjustments con- 8) Release the data setting which has been executed before ad-
tinuously unless the power is turned off. Only when the power is justment.
turned off during this adjustments, perform the data setting again,
then continue the adjustments. Order Page Address Data Procedure
1 4F 01 00 [Write]
Set up setting:
2 7F 68 40 [Write]
1) VIDEO OUT of SET UP setting............... NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don't 3 75 0A 00 [Write]
set the SET UP setting to “PAL”) 4 60 6C 00 [Set]
5 4F 02 00 [Set]
Data setting method 6 2F 21 00 [Write]
7 4F 0F 00 [Write]
Order Page Address Data Procedure
8 00 01 00 [Set]
1 00 01 01 [Set]
2 4F 01 20 [Write]
3 7F 68 00 [Write]
4 75 0A 04 [Write]
5 20 00 29 [Set]
6 20 01 29 [Write] (Note 1)
7 00 01 01 [Set]
8 4F 0F 01 [Write]
9 2F 21 0B [Write]
Check the data changes
10 60 C1 [Read]
to “02”.
11 4F 02 03 [Set]
12 60 6C 01 [Set]
13 Wait for 1 second.
Note 1: At this time, the set is reset and the power is turned off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click [Connect] on the SEUS screen to restore
the “connected” state. (In case that the power does not
turn on again, press the power button.)
Note 2: Repeat the “Data setting method”, if the power was turned
off and on during the “CAMERA SYSTEM ADJUST-
MENTS”.

6-12
DSC-V1

Picture Frame Setting How to reset the zoom and focus when they deviated:
Mode CAMERA Order Page Address Data Procedure
Subject Color bar chart 1 60 2C 01 [Set]
(Standard picture frame with the 2 60 90 00 [Set]
zoom lens at WIDE end)
3 60 91 00 [Set]
Measurement Point Video terminal of A/V OUT jack
(75 Ω terminated) 4 60 92 YL [Set] (Note)

Measuring Instrument Oscilloscope and monitor TV 5 60 93 YH [Set] (Note)

Specified value A=B, C=D, E=F 6 60 01 79 [Write]


Check the data changes
7 60 07 [Read]
Switch setting: to “01”.
1) FOCUS button .............................. AUTO 8 60 01 00 [Write]
2) MACRO (Control button) ............. ON Note: The data noted down at step 7 and 8 of “Setting method”.

Setting method:
Check on the oscilloscope
Order Page Address Data Procedure
Shoot the color bar chart 1. Horizontal period
1 with the zoom WIDE
A=B C=D
end.
2 60 8C 30 [Set] B C
Enter the output of A D
VIDEO OUT to the
3 monitor TV, and move
the position as shown in
Fig. 6-1-10.
Horizontal width of one
color (B, C) and that of
4 black (A, D) on the color
bar chart should be same.
(See Fig. 6-1-8)
With vertical width of
black (E, F) set in same,
the color bar chart
5
should come to the
center of monitor TV.
(See Fig. 6-1-9)
Fig. 6-1-8
Check that the color bar
6 on the monitor TV is 2. Vertical period
focused.
Read the data. E E=F F
7 10 44 [Read] Note down the data, and
this is named YH data.
Read the data.
8 10 45 [Read] Note down the data, and
V
this is named YL data.
Fig. 6-1-9
Processing after Completing Adjustments:
Order Page Address Data Procedure Check on the monitor TV
1 60 8C 00 [Set]

Color bar chart picture frame Monitor TV picture frame


Fig. 6-1-10

6-13
DSC-V1

1. Flange Back Adjustment Adjusting method:


(Using the minipattern box)
Order Page Address Data Procedure
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered. Perform “Data setting
during camera system
Mode CAMERA 1
adjustment”.
Subject Siemens star chart with ND filter (Refer to page 6-12)
for minipattern box (Note 1) 2 60 01 13 [Write]
Measurement Point Data of page: 6F, address: 24 and 3 60 01 27 [Write] (Note 5)
3E
Check the data changes
Adjustment Page 6F 4 60 02 [Read]
to “01”.
Adjustment Address 18 to 3E, 40 to 53 Check that the data
Specified value 1 00 5 6F 3E [Read] satisfied the specified
Specified value 2 0A to 40 value 1.
Note 1: Dark Siemens star chart. Check that the data
Note 2: Check that the data of page: 60, address: 02 is “00”. If 6 6F 24 [Read] satisfied the specified
not, press the RESET switch using a thin and long pin. value 2.
7 60 01 00 [Write]
Preparations before adjustments: 8 60 01 25 [Write]
1) The minipattern box is installed as shown in the following fig-
ure. 9 Wait for 3.5 seconds.
Note 3: The attachment lenses are not used. Note 5: The adjustment data will be automatically input to page:
Note 4: Take care not to hit the minipattern box when ex- 6F, address: 18 to 3E and 40 to 53.
tending the lens.
2) Install the minipattern box so that the distance between it and Processing after Completing Adjustments:
the front of lens of camera is less than 3 cm.
Order Page Address Data Procedure
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the 1 60 01 00 [Write]
specified voltage ± 0.01 Vdc. Release “ Data setting
5) Check that the center of Siemens star chart meets the center of during camera system
shot image screen with the zoom lens at TELE end and WIDE 2
adjustment”.
end respectively. (Refer to page 6-12)
Perform “Flange Back
Specified voltage: The specified voltage varies according to the 3
Check”.
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.

Below 3 cm

Minipattern box

Camera

Camera
table

Regulated power supply


Output voltage : Specified voltage ± 0.01 Vdc
Output current : more than 3.5 A

Red (+)
Black (–)

Yellow (SENS +)

White (SENS –) Need not connected


Black (GND)

Fig. 6-1-11

6-14
DSC-V1

2. Flange Back Check 3. F No. Compensation


Compensate the unevenness of the iris meter sensitivity.
Mode CAMERA
Subject Siemens star Mode CAMERA
(1.0 m from the front of the lens) Subject Clear chart
(Luminance: 200 to 400 lux) (Standard picture frame with the
Measurement Point Check operation on monitor TV zoom lens at WIDE end)
Measuring Instrument Measurement Point Data of page: 6F, address: 6B
Specified value Focused at the TELE end and Adjustment Page 6F
WIDE end Adjustment Address 60 to 64, 6B to 6D
Specified value 00
Checking method:
Note 1: Check that the data of page: 60, address: 02 is “00”. If
Order Page Address Data Procedure not, press the RESET switch using a thin and long pin.
Perform “Data setting
during camera system Adjusting method:
1
adjustment” Order Page Address Data Procedure
(Refer to page 6-12)
Perform “Data setting
Place the Siemens star during camera system
2 1.0 from the front of the 1
adjustment”.
lens. (Refer to page 6-12)
To open the IRIS, Perform “Picture frame
decrease the luminous 2 setting”
intensity to the Siemens (Refer to page 6-13)
3
star up to a point before
noise appear on the 3 60 01 BB [Write] (Note 2)
image. Check the data changes
4 60 02 [Read]
4 60 8C 30 [Set] to “01”.

5 5F 3D 50 [Set] Check that the data


5 6F 6B [Read] satisfied the specified
Set the zoom lens to the value.
TELE end then set the
6 center of the Siemens Note 2: The adjustment data will be automatically input to page:
star chart in the center of 6F, address: 60 to 64 and 6B to 6D.
the TV monitor.
Processing after Completing Adjustments:
Check that the lens is
7 Order Page Address Data Procedure
focused.
8 60 2C 01 [Set] 1 60 01 00 [Write]
9 7B 98 94 [Set] Release “Data setting
during camera system
While observe the TV 2
adjustment”
monitor, change the
(Refer to page 6-12)
10 zoom to the WIDE end
and check that the lens is
focused.

Processing after Completing Adjustments:


Order Page Address Data Procedure
The data reverts back to
1 5F 3D [Read]
the first.
The data reverts back to
2 7B 98 [Read]
the first.
3 60 8C 00 [Set]
Release “Data setting
during camera system
4
adjustment”
(Refer to page 6-12)

6-15
DSC-V1

4. Mechanical Shutter Adjustment 5. Light Value Adjustment


Adjust the period which the mechanical shutter is closed, and com- Adjust the standard light value.
pensate the exposure.
Mode CAMERA
Mode CAMERA Subject Clear chart
Subject Clear chart (Standard picture frame with the
(Standard picture frame with the zoom lens at WIDE end)
zoom lens at WIDE end) Measurement Point Data of page: 10, address: 0C and
Measurement Point Data of page: 6F, address: 6B 0D (2byte data) (Note 2)
Adjustment Page 6F Data of page: 6F, address: 65
Adjustment Address 6B to 6D, B8 to D7 Adjustment Page 6F
Specified value 00 Adjustment Address 65 to 67
Note 1: Check that the data of page: 60, address: 02 is “00”. If Specified value 1 0FE0 to 1020
not, press the RESET switch using a thin and long pin. Specified value 2 30 to 50

Adjusting method: Note 1: Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Order Page Address Data Procedure Note 2: 2byte data is upper 1byte data and lower 1 byte data.
1 Perform “Data setting XX XX
during camera system Lower 1byte data (Page: 10, address: 0D)
adjustment”. Upper 1byte data (Page: 10, address: 0C)
(Refer to page 6-12)
Adjusting method:
Perform “Picture frame
2 setting” Order Page Address Data Procedure
(Refer to page 6-13) Perform “Data setting
3 60 01 AD [Write] (Note 2) during camera system
1
Check the data changes adjustment”.
4 60 02 [Read] (Refer to page 6-12)
to “01”.
Check that the data Perform “Picture frame
5 6F 6B [Read] satisfied the specified 2 setting”
value. (Refer to page 6-13)
Note 2: The adjustment data will be automatically input to page: 3 60 01 0D [Write] (Note 3)
6F, address: 6B to 6D and B8 to D7. Check the data changes
4 60 02 [Read]
to “01”.
Processing after Completing Adjustments: Read the data
5 10 0C [Read]
Order Page Address Data Procedure (Upper 1byte).
1 60 01 00 [Write] Read the data
6 10 0D [Read]
(Lower 1byte).
Release “Data setting
during camera system Check that the 2byte
2 7 data (Note 2) satisfied
adjustment”
(Refer to page 6-12) the specified value 1.
Check that the data
8 6F 65 [Read] satisfied the specified
value 2.
Note 3: The adjustment data will be automatically input to page:
6F, address: 65 to 67.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 [Write]
Release “Data setting
during camera system
2
adjustment”
(Refer to page 6-12)

6-16
DSC-V1

6. Mixed Color Cancel Adjustment 7. AWB 3200K Standard Data Input


Correct the dispersion of Gr/Gb filter on CCD imager Adjust the white balance reference at 3200K.
Mode CAMERA Mode CAMERA
Subject Color bar chart Subject Clear chart
(Standard picture frame with the (Standard picture frame with the
zoom lens at WIDE end) zoom lens at WIDE end)
Measurement Point Data of page: 6F, address: B5 Measurement Point Data of page: 6F, address: B5
Adjustment Page 6F Adjustment Page 6F
Adjustment Address 6E and 6F Adjustment Address 70 to 87, B0, B2 and B4
Specified value 00 Specified value 00
Note 1: Check that the data of page: 60, address: 02 is “00”. If Note 1: Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin. not, press the RESET switch using a thin and long pin.

Adjusting method: Adjusting method:


Order Page Address Data Procedure Order Page Address Data Procedure
Perform “Data setting Perform “Data setting
during camera system during camera system
1 1
adjustment”. adjustment”.
(Refer to page 6-12) (Refer to page 6-12)
Perform “Picture frame Perform “Picture frame
2 setting” 2 setting”
(Refer to page 6-13) (Refer to page 6-13)
3 6F B5 FF [Write] 3 6F B5 FF [Write]
4 60 01 D7 [Write] 4 60 01 0B [Write] (Note 2)
5 Wait for 3 seconds. Check the data changes
5 60 02 [Read]
6 60 01 D5 [Write] (Note 2) to “01”.
Check the data changes Check that the data
7 60 02 [Read] 6 6F B5 [Read] satisfied the specified
to “01”.
value.
Check that the data
8 6F B5 [Read] satisfied the specified Note 2: The adjustment data will be automatically input to page:
value. 6F, address: 70 to 87, B0, B2 and B4.
Note 2: The adjustment data will be automatically input to page: Processing after Completing Adjustments:
6F, address: 6E and 6F
Order Page Address Data Procedure
Processing after Completing Adjustments: 1 60 01 00 [Write]
Order Page Address Data Procedure Perform “AWB 5800K
2
1 60 01 00 [Write] Standard Data Input”.
Release “Data setting
during camera system
2
adjustment”
(Refer to page 6-12)

6-17
DSC-V1

8. AWB 5800K Standard Data Input 9. AWB 5800K Check


Adjust the white balance reference at 5800K.
Mode CAMERA
Mode CAMERA Subject Clear chart
Subject Clear chart (Standard picture frame with the
(Standard picture frame with the zoom lens at WIDE end)
zoom lens at WIDE end) Filter Filter C14 for color temperature
Filter Filter C14 for color temperature correction
correction Measurement Point Data of page: 6F, address: B5
Measurement Point Data of page: 6F, address: B5 Specified value 00
Adjustment Page 6F Note: Check that the data of page: 60, address: 02 is “00”. If not,
Adjustment Address 88 to A3, B1 and B3 press the RESET switch using a thin and long pin.
Specified value 00
Checking method:
Note 1: Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin. Order Page Address Data Procedure
Note 2: Perform this check after “AWB 3200K Standard Data Place the C14 filter on
Input” without a break. 1
the lens.
Perform “Data setting
Adjusting method:
during camera system
2
Order Page Address Data Procedure adjustment”.
“AWB 3200K Standard (Refer to page 6-12)
1 Data Input” is com- Perform “Picture frame
pleted. 3 setting”
Place the C14 filter on (Refer to page 6-13)
2
the lens. 4 6F B5 FF [Write]
3 6F A0 2A [Write] 5 60 01 3F [Write]
4 6F A1 7E [Write] Check the data changes
6 60 02 [Read]
5 6F A2 5F [Write] to “01”.
6 6F A3 81 [Write] Check that the data
7 6F B5 [Read] satisfied the specified
7 6F B5 FF [Write] value.
8 60 01 A5 [Write] (Note 3)
Check the data changes Processing after Completing Adjustments:
9 60 02 [Read]
to “01”.
Order Page Address Data Procedure
Check that the datasatis-
10 6F B5 [Read] 1 60 01 00 [Write]
fied the specified value.
Release “Data setting
Note 3: The adjustment data will be automatically input to page:
during camera system
6F, address: 88 to A3, B1 and B3. 2
adjustment”
(Refer to page 6-12)
Processing after Completing Adjustments:
Remove the C14 filter
Order Page Address Data Procedure 3
on the lens.
1 60 01 00 [Write]
Release “Data setting
during camera system
2
adjustment”
(Refer to page 6-12)
Remove the C14 filter
3
on the lens.

6-18
DSC-V1

10. AWB 3200K Check 11. CCD Linearity Check


Check that CCD output keep being straight even ISO sensitivity is
Mode CAMERA
changed.
Subject Clear chart
(Standard picture frame with the Mode CAMERA
zoom lens at WIDE end) Subject Clear chart
Measurement Point Data of page: 6F, address: B5 (Standard picture frame with the
zoom lens at WIDE end)
Specified value 00
Specified value 1 97 to 103 (Decimal)
Note: Check that the data of page: 60, address: 02 is “00”. If not,
press the RESET switch using a thin and long pin. Specified value 2 96 to 104 (Decimal)
Note: 2byte data is upper 1byte data and lower 1byte data.
Checking method: XX XX
Lower 1byte data
Order Page Address Data Procedure
(Page: 10, address: 81 or 83)
Perform “Data setting Upper 1byte data
during camera system (Page: 10, address: 80 or 82)
1
adjustment”.
(Refer to page 6-12) Checking method:
Perform “Picture frame Order Page Address Data Procedure
2 setting”
(Refer to page 6-13) Perform “Data setting
during camera system
3 6F B5 FF [Write] 1
adjustment”
4 60 01 0F [Write] (Refer to page 6-12)
Check the data changes Perform “Picture frame
5 60 02 [Read]
to “01”. 2 setting”
Check that the data (Refer to page 6-13)
6 6F B5 [Read] satisfied the specified 3 75 09 04 [Set]
value. 4 77 F6 00 [Set]
5 77 F7 42 [Set]
Processing after Completing Adjustments:
6 77 F2 82 [Set]
Order Page Address Data Procedure
7 60 14 90 [Set]
1 60 01 00 [Write]
8 60 12 9F [Set]
Release “Data setting
9 60 05 16 [Set]
during camera system
2 10 75 21 88 [Set]
adjustment”
(Refer to page 6-12) 11 75 22 00 [Set]
12 75 23 BB [Set]
13 75 24 1B [Set]
14 75 25 24 [Set]
15 Wait for 2 seconds.
16 60 01 F9 [Write]
Check the data changes
17 60 E1 [Read]
to “08”.
Read the data
18 10 80 [Read]
(Upper 1byte).
Read the data
19 10 81 [Read]
(Lower 1byte).
This 2byte data (Note) is
20
named D1.
Read the data
21 10 82 [Read]
(Upper 1byte).
Read the data
22 10 83 [Read]
(Lower 1byte).
This 2byte data (Note) is
23
named D2.
24 60 01 00 [Write]
25 60 E1 00 [Set]

6-19
DSC-V1

Order Page Address Data Procedure Order Page Address Data Procedure
26 77 72 54 [Set] The data reverts back to
60 75 22 [Read]
27 Wait for 2 seconds. the first.
28 60 01 F9 [Write] The data reverts back to
61 75 23 [Read]
the first.
Check the data changes
29 60 E1 [Read] The data reverts back to
to “08”. 62 75 24 [Read]
the first.
Read the data
30 10 80 [Read] The data reverts back to
(Upper 1byte). 63 75 25 [Read]
the first.
Read the data
31 10 81 [Read] Convert D1, D2, D3, D4,
(Lower 1byte).
D5, D6 to decimal
This 2byte data (Note) is 64
32 notation, and obtain D1’,
named D3. D2’, D3’, D4’, D5’ D6’.
Read the data
33 10 82 [Read] Calculate S1, S2, S3, S4
(Upper 1byte). using following
Read the data equations.
34 10 83 [Read]
(Lower 1byte). (Decimal calculation)
65
This 2byte data (Note) is S1 = (D3’ ÷ D1’) × 100
35 S2 = (D4’ ÷ D2’) × 100
named D4.
S3 = (D5’ ÷ D1’) × 100
36 60 01 00 [Write]
S4 = (D6’ ÷ D2’) × 100
37 60 E1 00 [Set]
Check that the S1 and S2
38 60 12 A2 [Set] 66 satisfies the specified
39 77 72 09 [Set] value 1.
40 Wait for 2 seconds. Check that the S3 and S4
67 satisfies the specified
41 60 01 F9 [Write]
value 2.
Check the data changes
42 60 E1 [Read]
to “08”.
Processing after Completing Adjustment:
Read the data
43 10 80 [Read] Order Page Address Data Procedure
(Upper 1byte).
Read the data Release “Data setting
44 10 81 [Read] during camera system
(Lower 1byte). 1
adjustment”
This 2byte data (Note) is (Refer to page 6-12)
45
named D5.
Read the data
46 10 82 [Read]
(Upper 1byte).
Read the data
47 10 83 [Read]
(Lower 1byte).
This 2byte data (Note) is
48
named D6.
49 60 01 00 [Write]
50 60 E1 00 [Set]
51 60 12 00 [Set]
52 60 14 00 [Set]
The data reverts back to
53 75 09 [Read]
the first.
The data reverts back to
54 77 F6 [Read]
the first.
The data reverts back to
55 77 F7 [Read]
the first.
The data reverts back to
56 77 F2 [Read]
the first.
The data reverts back to
57 77 72 [Read]
the first.
58 60 05 00 [Set]
The data reverts back to
59 75 21 [Read]
the first.

6-20
DSC-V1

12. Color Reproduction Adjustment Processing after Completing Adjustments:


Adjust the color separation matrix coefficient so that proper color
Order Page Address Data Procedure
reproduction is produced.
1 60 01 00 [Write]
Mode CAMERA
The data reverts back to
Subject Color bar chart 2 7F 68 [Read]
the first.
(Standard picture frame with the
zoom lens at WIDE end) Release “Data setting
during camera system
Measurement Point Video terminal of A/V OUT jack 3
adjustment”
(75 Ω terminated) (Refer to page 6-12)
Data of page: 6F, address: B5
Measuring Instrument Vectorscope
Adjustment Page 6F
Adjustment Address A4 to AF
R-Y
Specified value 00
Menu setting:
1) VIDEO OUT of SET UP menu MG
R
................................. NTSC (NTSC mode)

Note 1: Check that the data of page: 60, address: 02 is “00”. If


not, press the RESET switch using a thin and long pin.

Adjusting method: YE W
B-Y
Order Page Address Data Procedure
B
Perform “Data setting
during camera system
1
adjustment”.
(Refer to page 6-12)
Perform “Picture frame
G
2 setting” CY
(Refer to page 6-13)
3 7F 68 00 [Set] Burst position

4 6F B5 FF [Write]
5 60 01 AB [Write]
6 60 12 80 [Write] Fig. 6-1-12
7 Wait for 1 seconds.
8 60 12 00 [Write]
9 Wait for 2 seconds.
10 60 01 A9 [Write] (Note 2)
Check the data changes
11 60 02 [Read]
to “01”.
Check that the data
12 6F B5 [Read] satisfied the specified
value.
Check the each color
luminance point is in
13
each color reproduction
frame.
Note 2: The adjustment data will be automatically input to page:
6F, address: A4 to AF.

6-21
DSC-V1

13. CCD White Defect Compensation


Mode CAMERA
Subject Not required
Measurement Point Data of page: 60, address: 55
Note 1: Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Note 2: The “CCD White Defect Compensation” should be made
when the set warms up at certain duration after the power
was turned on, as it is affected with the temperature.

Adjusting method:
Order Page Address Data Procedure
Perform “Data setting
during camera system
1
adjustment”.
(Refer to page 6-12)
2 7D 64 1E [Set]
3 7D 69 18 [Set]
4 60 01 8B [Write]
Check the data changes
5 60 02 [Read]
to “01”.
Check the data.
6 60 55 [Read] 00 to 7F: Normal
80 to FF: Defective
7 60 01 00 [Write]
8 7D 64 0F [Set]
9 7D 69 60 [Set]
10 60 01 87 [Write]
Check the data changes
11 60 02 [Read]
to “01”.
Check the data.
12 60 55 [Read] 00 : Normal
01 to FF: Defective

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 [Write]
2 7D 64 0F [Set]
3 7D 69 43 [Set]
Release “Data setting
during camera system
4
adjustment”
(Refer to page 6-12)

6-22
DSC-V1

14. CCD Black Defect Compensation Processing after Completing Adjustments:


Mode CAMERA Order Page Address Data Procedure
Subject Clear chart 1 60 01 00 [Write]
(Standard picture frame with the 2 60 91 00 [Set]
zoom lens at WIDE end)
3 60 30 00 [Set]
Measurement Point Data of page: 60, address: 55
4 7D 65 4C [Set]
Note 1: Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin. Release “Data setting
Note 2: Check that there are no dust, no dirt and reflection of the during camera system
5
clear chart. adjustment”
Note 3: Any subject other than the clear chart should be in the (Refer to page 6-12)
screen.

Adjusting method:
Order Page Address Data Procedure
Perform “Data setting
during camera system
1
adjustment”.
(Refer to page 6-12)
Perform “Picture frame
2 setting”
(Refer to page 6-13)
3 7D 65 4C [Set]
4 60 90 00 [Set]
5 60 91 03 [Set]
6 60 92 00 [Set]
7 60 93 00 [Set]
8 60 01 79 [Write]
9 60 30 08 [Set]
Check the data changes
10 60 07 [Read]
to “01”.
11 60 01 8D [Write]
Check the data changes
12 60 02 [Read]
to “01”.
Check the data.
00: Proceed to “Process-
ing after Completing
13 60 55 [Read]
Adjustment”
00 to 14 : Normal
15 to FF : Defective
14 60 01 00 [Write]
15 7D 65 5A [Set]
16 60 01 89 [Write]
Check the data changes
17 60 02 [Read]
to “01”.
Check the data.
18 60 55 [Read] 00 : Normal
01 to FF : Defective

6-23
DSC-V1

15. Strobe Adjustment Adjusting method:


Adjust the light value and white balance when strobe light flashed.
Order Page Address Data Procedure
Mode CAMERA Perform “Data setting
Subject Flash adjustment box (Note 2) during camera system
1
(50 cm from the front of lens) adjustment”.
Measurement Point Data of page: 6F, address: DC (Refer to page 6-12)
and B5 2 60 2C 01 [Set]
Adjustment Page 6F 3 60 90 00 [Set]
Adjustment Address B6, B7 and D8 to EF 4 60 91 00 [Set]
Specified value 1 03 to 0E 5 60 92 FF [Set]
Specified value 2 00 6 60 93 FF [Set]
Note 1: Perform this adjustment in the Flash adjustment box. 7 60 01 79 [Write]
Note 2: Refer to “4. Preparing the Flash adjustment box”. (See Check the data changes
page 6-6) 8 60 07 [Read]
to “01”.
Note 3: “Strobe Adjustment” is available only once after the
power is turned on. If the adjustment is retried, press the 9 6F B5 FF [Write]
RESET switch using a thin and long pin. Check the flashing.
10 60 01 B9 [Write]
Note 4: Check that the data of page: 60, address: 02 is “00”. If (Note 5)
not, press the RESET switch using a thin and long pin. Check the data changes
11 60 02 [Read]
to “01”.
Switch setting:
1) FLASH (Control button) .................... ON
12 6F D8 [Read] Check the data is “00”.
13 60 01 00 [Write]
Check the data changes
14 60 ED [Read]
to “02”.
15 60 01 E7 [Write] Check the flashing.
Check the data changes
16 60 02 [Read]
to “01”.
17 6F D8 [Read] Check the data is “00”.
Check that the data
18 6F DC [Read] satisfied the specified
value 1.
Check that the data
19 6F B5 [Read] satisfied the specified
value 2.
Note 5: The adjustment data will be automatically input to page:
6F, address: B6, B7 and D8 to EF.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 60 01 00 [Write]
2 60 92 00 [Set]
3 60 93 00 [Set]
4 60 2C 00 [Set]
Release “Data setting
during camera system
5
adjustment”.
(Refer to page 6-12)

6-24
DSC-V1

16. Hologram AF Data Input


Set the data for laser output of the hologram AF.
Mode CAMERA
Adjustment Page 6F
Adjustment Address 10 to 14 and 54

Input method:
Order Page Address Data Procedure
1 00 01 01 [Set]
2 6F 10 91 [Write]
3 6F 11 00 [Write]
4 6F 12 00 [Write]
5 6F 13 00 [Write]
6 6F 14 00 [Write]
7 6F 54 00 [Write]

Processing after Completing Input:


Order Page Address Data Procedure
1 00 01 00 [Set]

6-25
DSC-V1

17. Hologram AF Angle Check Checking method:


Check a deviation of optical axis between hologram AF and cam-
Order Page Address Data Procedure
era image.
Perform “Data setting
Mode CAMERA during camera system
1
Subject Flash adjustment box (Note 2) adjustment”
(1 m from the front of lens) (Refer to page 6-12)
Measurement Point Check operation on monitor TV 2 60 30 06 [Set]
Measuring Instrument 3 5F 3D 50 [Set]
Specified value All luminance points should 4 60 2C 01 [Set]
settle within specification frame. 5 60 90 00 [Set]
Note 1: Perform this adjustment in the Flash adjustment box. 6 60 91 00 [Set]
Restrict external light to enter the Flash adjustment box
as less as possible. 7 60 92 00 [Set]
Note 2: Refer to “4. Preparing the Flash adjustment box”. (See 8 60 93 40 [Set]
page 6-6) 9 60 01 79 [Write]
Note 3: Perform checking by making the shooting surface of the
Check the data changes
Flash adjustment box perpendicular to the optical axis of 10 60 07 [Read]
to “01”.
the camera.
11 60 01 00 [Write]
12 60 22 05 [Set]
Preparation
13 60 23 0A [Set]
1) Take a reduced or enlarged copy on the clear sheet so that a
rectangular frame of the sheet for auxiliary light is suitable for Check that the hologram
the effective image size of the monitor. patterns are all within the
2) Stick the copied sheet for auxiliary light on the monitor screen. specification frame.
14
(None of the hologram
patterns are completely
out of the frame)

Processing after Completing Adjustment:


Order Page Address Data Procedure
The data reverts back to
1 5F 3D [Read]
the first.
2 60 23 00 [Set]
3 60 2C 00 [Set]
4 60 30 00 [Set]
5 60 93 00 [Set]
Release “Data setting
during camera system
6
adjustment”
Specification frame (Refer to page 6-12)

Fig. 6-1-13

6-26
DSC-V1

COVER

1-5. LCD SYSTEM ADJUSTMENTS 2. VCO Adjustment (SY-089 Board)


Set the VCO free-run frequency. If deviated, the LCD screen will
Note 1: Taken an extreme care not to destroy the liquid crystal be blurred.
display module by static electricity when replacing it. Mode PLAY
Note 2: Set the LCD BRIGHTNESS (SET UP setting) to the
NORMAL. Signal Arbitrary
Measurement Point Data of page: 40, address: 4F
1. LCD Initial Data Input Adjustment Page 4F
Mode PLAY Adjustment Address 82 (NTSC mode)
Signal Arbitrary 83 (PAL mode)
Adjustment Page 4F Specified value 00
Adjustment Address 80 to 8A, 8F, 91 to 93, 95, A3, A4
Menu setting:
Note: “Memory Stick” must be inserted. 1) VIDEO OUT of SET UP menu
................................. NTSC (NTSC mode)
Input method: (This adjustment must be performed in NTSC mode, so don’t set
1) Select page: 00, address: 01, and set data: 01. the menu setting to “PAL”)
2) Select page: 4F, and write the data given in the following table.
Address Data Remark Adjusting method:
80 5F Order Page Address Data Procedure
Fixed value
81 EF 1 00 01 01 [Set]
82 90 VCO adjustment (NTSC mode) 2 4F 99 1D [Write]
83 9B VCO adjustment (PAL mode) 3 40 4F 01 [Set]
84 91 V-COM adjustment 4 40 4E 01 [Set] (Note)
85 B2 Bright adjustment Check that the data
86 2D Black Limit adjustment 5 40 4F [Read] satisfied the specified
value.
87 41 Fixed value
Read the data and this
88 84 6 4F 82 [Read]
White Balance adjustment data is named D82.
89 66
Calculate D83 using
8A 3F Contrast adjustment following equations.
8F B2 7 (hexadecimal calcula-
tion)
91 40
D83 = D82 + 0B
92 2E
8 4F 83 D83 [Write]
93 0E Fixed value
Note: The adjustment data will be automatically input to
95 1F page: 4F, address: 82.
A3 24
Processing after Completing Adjustments:
A4 12
Order Page Address Data Procedure
Processing after Completing Input: 1 00 01 00 [Set]
1) Select page: 00, address: 01, and set data: 00.

6-27
DSC-V1

3. Bright Adjustment (SY-089 Board) 4. Contrast Adjustment (SY-089 Board)


Set the amplitude of the RGB decoder for driving the LCD to the Set the level of the VIDEO signal for driving the LCD to the speci-
specified value. fied value.
If deviated, the LCD screen image will be blackish or saturated If deviated, the LCD screen image will be blackish or saturated
(whitish). (whitish).
Mode PLAY Mode PLAY
Signal Arbitrary Signal Arbitrary
Measurement Point Data of page: 40, address: 4F Measurement Point Data of page: 40, address: 4F
Adjustment Page 4F Adjustment Page 4F
Adjustment Address 85 Adjustment Address 8A
Specified value 00 Specified value 00
Note 1: Perform “Bright Adjustment” before this adjustment.
Adjusting method:
Adjusting method:
Order Page Address Data Procedure
1 00 01 01 [Set] Order Page Address Data Procedure
2 4F 8F B1 [Write] 1 00 01 01 [Set]
3 40 4F 02 [Set] 2 4F 91 40 [Write]
4 40 4E 01 [Set] (Note) 3 40 4F 03 [Set]
Check that the data 4 40 4E 01 [Set] (Note 2)
5 40 4F [Read] satisfied the specified Check that the data
value. 5 40 4F [Read] satisfied the specified
Note: The adjustment data will be automatically input to value.
page: 4F, address: 85. Note 2: The adjustment data will be automatically input to
page: 4F, address: 8A.
Processing after Completing Adjustments:
Processing after Completing Adjustments:
Order Page Address Data Procedure
1 00 01 00 [Set] Order Page Address Data Procedure
1 00 01 00 [Set]

6-28
DSC-V1

5. Black Limit Adjustment (SY-089 Board) 6. V-COM Adjustment (SY-089 Board)


Set the black limit voltage of LCD panel to the specified value. Set the DC bias of the common electrode drive signal of LCD to
If deviated, the LCD screen image will be blackish or saturated the specified value.
(whitish). If deviated, the LCD display will be move, producing flicker and
conspicuous vertical lines.
Mode PLAY
Signal Arbitrary Mode PLAY
Measurement Point Data of page: 40, address: 4F Signal Arbitrary
Adjustment Page 4F Measurement Point Check on the LCD screen
Adjustment Address 86 Measuring Instrument
Specified value 00 Adjustment Page 4F
Adjustment Address 84
Adjusting method: Specified value The brightness difference between
the section-A and section-B is
Order Page Address Data Procedure
minimum
1 00 01 01 [Set]
2 4F 9F BD [Write] Adjusting method:
3 40 4F 04 [Set] Order Page Address Data Procedure
4 40 4E 01 [Set] (Note) 1 00 01 01 [Set]
Check that the data 2 40 F1 82 [Set]
5 40 4F [Read] satisfied the specified
value. Change the data so that
3 4F 84 brightness of the section
Note: The adjustment data will be automatically input to A and section B is equal.
page: 4F, address: 86.
Subtract 6 from the data,
4 4F 84 [Write]
Processing after Completing Adjustments and write this data.

Order Page Address Data Procedure


Processing after Completing Adjustments:
1 00 01 00 [Set]
Order Page Address Data Procedure
1 40 F1 00 [Set]
2 00 01 00 [Set]

B A

A B

B A

A B

Fig. 6-1-14

6-29
DSC-V1

7. White Balance Adjustment (SY-089 Board)


Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode PLAY
Signal Arbitrary
Measurement Point Check on the LCD screen
Measuring Instrument
Adjustment Page 4F
Adjustment Address 88, 89
Specified value LCD screen must not be colored
Note 1: Check the white balance only when replacing the fol-
lowing parts. If necessary, adjust them.
1. LCD901 PANEL UNIT
2. IC801

Adjusting method:
Order Page Address Data Procedure
1 00 01 01 [Set]
2 40 F1 0A [Set]
Write the data.
3 4F 88 84 [Write]
(Initial value)
Write the data.
4 4F 89 66 [Write]
(Initial value)
Check that the LCD
screen is not colored. If
not colored, proceed to
5
“Processing after
Completing Adjust-
ments”.
Change the data so that
88 the LCD screen is not
6 4F [Write]
89 colored, and write this
data.

Processing after Completing Adjustments:


Order Page Address Data Procedure
1 40 F1 00 [Set]
2 00 01 00 [Set]

6-30
DSC-V1

COVER

6-2. SERVICE MODE 2. Operation


• Page change
2-1. APPLICATION FOR ADJUSTMENT (SEUS) To change the page, click [Page] on the SEUS screen and enter
the page to be changed. The page is displayed in hexadecimal
The application for adjustment (SEUS) is used to change the coef- notation.
ficient for calculating the signal processing or EVR data. The SEUS
performs two-way communication between PC and set through • Address change
the USB terminal. The two-way communication result data can be To change the address, click [Address] on the SEUS screen and
written to the nonvolatile memory. enter the address to be changed. The address is displayed in
hexadecimal notation.
2-1-1. Using Method of SEUS
1. Connection • Data change
1) Connect the HASP key to the USB terminal of the PC. To change the data, click [Set] on the SEUS screen and enter
2) Connect the PC and set with the USB cable. the data. The data is displayed in hexadecimal notation.
3) Confirm that the set starts in the USB mode. This operation does not write the data to the nonvolatile memory.
4) Start the SEUS on the PC.
5) Click [Connect] on the SEUS screen. If the connection is nor- • Data writing
mal, the SEUS screen will be as shown in Fig. 6-2-1, indicat- To write the data to the nonvolatile memory, click [Write] on
ing the “connected” state. the SEUS screen and enter the data to be written.
Note: The SEUS will go in “disconnect" state, if the set is
• Data reading
turned off (for instance, by resetting the set). In such a
The data displayed on the SEUS screen are the data values at
case, click [Connect] on the SEUS screen to restore
the time when the pages and addresses were set, and they are
the “connected” state. not updated automatically. To check the data change, click
[Read] on the SEUS screen and update the displayed data.

2-1-2. Precaution on Use of SEUS


Wrong SEUS operation could clear correct adjustment data. To
prevent the data clear by mistake, it is recommended to save all
adjustment data by clicking [Page Edit] on the SEUS screen be-
fore starting the adjustment.

Fig. 6-2-1

6-31
DSC-V1

COVER

2-2. DATA PROCESS 2-3. SERVICE MODE

In some adjustment items, the calculation of SEUS displayed data 1. Setting the Test Mode
(hexadecimal) is needed to check the specified data or to acquire
the adjustment data. In such a case, prepare a computer capable of Page 2F Address 21
calculating hexadecimal numbers.
Also, the data at two addresses are read, which are treated as 2 Data Function
bytes of upper 1 byte and lower 1 byte (4-digit hex. number), to
check the specified data. 00 Normal
01 Forced S (shutter speed) mode

XX XX
02 Forced A (aperture) mode
03 Forced M (manual) mode
04 Forced SCN (scene selection) mode
Displayed data at lower 1 byte address 05 Forced MOVIE mode
Displayed data at upper 1 byte address 08 Forced PLAY mode
09 Forced SET UP mode
0A Forced CAMERA (auto) mode
0B Forced P (program) mode

• Before setting the data, select page: 00, address: 01, and set
data: 01.
• In the case of page 2F, writing the data by clicking [Write] on
the SEUS screen causes the data to be written to the nonvolatile
memory. In this case, the Test mode is not released even if the
set is turned off, thus requiring extreme care.
• After the adjustment/repair finished, be sure to return the data
to “00” to restore the Normal mode. Also, select page: 00, ad-
dress: 01, and set data: 00.

6-32
DSC-V1

2. Bit Value Discrimination 3. LED Check


In the following items, the bit values must be discriminated from
the data displayed on the SEUS. Whether bit values are “1” or “0” Page 20 Address 04 Data 02
can be discriminated from the table shown below.
Using method:
Data displayed on SEUS 1) Select page: 20, address: 04, set data: 02.
2) Check that all LED (SELF TIMER, POWER, SELF TIMER/
RECODING, AE/AF LOCK, FLASH/CHG, MS ACCESS) are

00 lit.
3) Select page: 20, address: 04, set data: 00.

bit 3 to bit 0 discriminated


bit 7 to bit 4 discriminated 4. Jog Dial Check
Page 20 Address 81

Bit values Using method:


Display on the bit3 bit2 bit1 bit0 1) Set the mode dial to any position other than “SET UP’”.
SEUS or or or or 2) Select page: 20, address: 81.
bit7 bit6 bit5 bit4 3) By discriminating the upper digit of read data, the rotation of
the control dial can be discriminated.
0 0 0 0 0
1 0 0 0 1 Jog dial Upper digit of the data
(MODE-51470 block S106)
2 0 0 1 0
When rotated upward. ...→ 1 → 5 → D → 9 → 1 →...
3 0 0 1 1 ...→ 1 → 9 → D → 5 → 1 →...
When rotated downward.
4 0 1 0 0
5 0 1 0 1
6 0 1 1 0 5. Switch Check (1)
7 0 1 1 1
Page 20 Address 80
A 8 1 0 0 0
9 1 0 0 1
Bit Function When bit value=1 When bit value=0
A 1 0 1 0
POWER SW
B 1 0 1 1 0 OFF ON
(MODE-51470 block
C 1 1 0 0 S104)
D 1 1 0 1 1
B E 1 1 1 0 2
F 1 1 1 1 Shutter button
(XSHTR ON)
3 OFF ON
Example: If the displayed data is “8E”, bit 7 - bit 4 values can be (MODE-51470 block
discriminated from block (A), and also bit 3 - bit 0 val- S103)
ues from block (B). Shutter button
(XAE LOCK ON)
4 OFF ON
(MODE-51470 block
S103)
MEMORY STICK
5 IN SW IN OUT
(MS Socket)

Using method:
1) Select page: 20, address: 80.
2) By discriminating the bit value of read data, the state of the
switches can be discriminated.

6-33
DSC-V1

6. Switch Check (2)

Page 20 Addresses 91 to 95

Using method:
1) Select page: 20, addresses: 91 to 95.
2) By discriminating the read data, the pressed key can be dis-
criminated.

Data
Address
00 to 0C 0D to 27 28 to 48 49 to 73 74 to DC DD to FF
IMAGE SIZE/
91 MENU CONTROL DOWN CONTROL RIGHT
DELETE
(KEY AD0) (GL-51470 block) (GL-51470 block) (GL-51470 block) (GL-51470 block) No key input
(IC402 tg) (S251) (S252) (S253) (S254)
DISPLAY/LCD
92 CONTROL UP CONTROL SET CONTROL LEFT
ON/OFF
(KEY AD1) (GL-51470 block) (GL-51470 block) (GL-51470 block) (GL-51470 block) No key input
(IC402 th) (S255) (S256) (S257) (S258)
EXECUTE EXPOSURE/
93 FOCUS AE LOCK
(JOG DIAL) INDEX
(KEY AD2) (MODE-51470 block) (GL-51470 block) (GL-51470 block) (GL-51470 block) No key input
(IC402 tj) (S106) (S259) (S260) (S261)
94 ZOOM DOWN ZOOM UP NIGHT SHOT NIGHT FLAMING
(KEY AD3) (MODE-51470 block) (MODE-51470 block) (MODE-51470 block) (MODE-51470 block) No key input
(IC402 tk) (S101) (S105) (S102) (S102)
LENS ADAPTOR
95
DETECT
(KEY AD4) (SW-395 flexible) No key input
(IC402 tl) (S101)

7. Mode Dial Check (1)

Page 20 Address 80, 81

When bit When bit


Address Bit Function
value=1 value=0
80 1 PLAY others PLAY
81 4 SET UP others SET UP

Using method:
1) Select page: 20, address: 80 and 81.
2) By discriminating the bit value of read data, the state of the
switches can be discriminated.

6-34
DSC-V1

8. Mode Dial Check (2)

Page 20 Addresses 90, 96

Using method:
1) Select page: 20, addresses: 90 and 96.
2) By discriminating the read data, the pressed key can be discriminated.

Data
Address
00 to 0C 0D to 27 28 to 48 49 to 73 74 to DC DD to FF
90 S (shutter speed) A (aperture) M (manual) SCN (scene selection) MOVIE
(MODE DIAL) (MODE-51470 block) (MODE-51470 block) (MODE-51470 block) (MODE-51470 block) (MODE-51470 block) others
(IC402 tf) (S108) (S108) (S108) (S108) (S108)
96 CAMERA (auto) P (program)
(MODE DIAL 2) (MODE-51470 block) (MODE-51470 block) others
(IC402 y;) (S108) (S108)

9. Self Diagnosis Code


Display Code Countermeasure Cause Caution Display During Error

C:32:ss Turn the power off and on again. Trouble with hardware. SYSTEM ERROR

Format the “Memory stick”. Unformatted memory stick is inserted. FORMAT ERROR
C:13:ss
Insert a new “Memory Stick”. Memory stick is broken. MEMORY STICK ERROR
When failed in the focus and zoom
E:61:ss Checking of lens drive circuit.
initialization.

Checking of flash unit or replacement Abnormality when flash is being
E:91:ss
of flash unit. charged.

6-35
DSC-V1

AF ILLUMINATION CHECK Take a reduced or enlarged copy on the clear sheet so that a
rectangular frame of the SHEET FOR AUXILIARY LIGHT
is suitable for the effective image size of the monitor.

DSC-V1

6-36
DSC-V1

FOR CAMERA COLOR REPRODUCTION ADJUSTMENT

Take a copy of CAMERA COLOR


REPRODUCTION FRAME with a
For NTSC mode
clear sheet for use.

R-Y

R MG

YE W
B-Y
B

G
CY

✄ DSC-V1

6-37E
6-37
Reverse 987626151.pdf

Revision History

S.M. Rev.
Ver. Date History Contents
issued
1.0 2003.05 Official Release — —