Before starting adjustments SERVICE MODE
Adjusting items when replacing main parts and boards APPLICATION FOR ADJUSTMENT (SEUS)
DATA PROCESS
CAMERA SECTION ADJUSTMENTS
SERVICE MODE
PREPARATIONS BEFORE ADJUSTMENTS
2003E0500-1
©2003.5
9-876-261-51 Sony EMCS Co. Published by DI Customer Center
DSC-V1
TABLE OF CONTENTS
Section Title Page Section Title Page
6. ADJUSTMENTS 6-2. Service Mode ································································· 6-31
Before starting adjustment ························································· 6-1 2-1. Application for Adjustment (SEUS) ······························ 6-31
1-1. Adjusting Items when Replacing 2-1-1. Using Method of SEUS ················································· 6-31
Main Parts and Boards ···················································· 6-2 1. Connection ····································································· 6-31
6-1. Camera Section Adjustments ··········································· 6-3 2. Operation ······································································· 6-31
1-1. Preparations Before Adjustments ···································· 6-3 2-1-2. Precaution on Use of SEUS ··········································· 6-31
1-1-1. List of Service Tools ························································ 6-3 2-2. Data Process ·································································· 6-32
1-1-2. Preparations ····································································· 6-4 2-3. Service Mode ································································· 6-32
1-1-3. Precautions ······································································ 6-5 1. Setting the Test Mode ···················································· 6-32
1. Setting the Switch ···························································· 6-5 2. Bit Value Discrimination ··············································· 6-33
2. Order of Adjustments ······················································ 6-5 3. LED Check ···································································· 6-33
3. Subjects ··········································································· 6-5 4. Jog Dial Check ······························································ 6-33
4. Preparing the Flash Adjustment Box ······························· 6-6 5. Switch Check (1) ··························································· 6-33
1-2. Initialization of 0E, 2F, 4F, 6F Page Data ······················· 6-7 6. Switch Check (2) ··························································· 6-34
1-2-1. Initialization of 0E, 2F, 4F, 6F Page Data ······················· 6-7 7. Mode Dial Check (1) ····················································· 6-34
1. Initializing 0E, 2F, 4F, 6F Page Data ······························· 6-7 8. Mode Dial Check (2) ····················································· 6-35
2. 0E Page table ··································································· 6-7 9. Self Diagnosis Code ······················································ 6-35
3. 2F Page table ··································································· 6-7
4. 4F Page table ··································································· 6-7
5. 6F Page Table ·································································· 6-8 * The sheet for auxiliary light is shown on page 6-36.
1-3. Video System Adjustments ············································ 6-11 * The color reproduction frame is shown on page 6-37.
1. Composite Video Level Adjustment ······························ 6-11
1-4. Camera System Adjustments ········································· 6-12
Data Setting During Camera System Adjustments ········ 6-12
Picture Frame Setting ···················································· 6-13
1. Flange Back Adjustment
(Using the minipattern box) ·········································· 6-14
2. Flange Back Check ························································ 6-15
3. F No. Compensation ······················································ 6-15
4. Mechanical Shutter Adjustment ···································· 6-16
5. Light Value Adjustment ················································· 6-16
6. Mixed Color Cancel Adjustment ··································· 6-17
7. AWB 3200K Standard Data Input ································· 6-17
8. AWB 5800K Standard Data Input ································· 6-18
9. AWB 5800K Check ······················································· 6-18
10. AWB 3200K Check ······················································· 6-19
11. CCD Linearity Check ···················································· 6-19
12. Color Reproduction Adjustment ···································· 6-21
13. CCD White Defect Compensation ································ 6-22
14. CCD Black Defect Compensation ································· 6-23
15. Strobe Adjustment ························································· 6-24
16. Hologram AF Data Input ··············································· 6-25
17. Hologram AF Angle Check ··········································· 6-26
1-5. LCD System Adjustments ············································· 6-27
1. LCD Initial Data Input ·················································· 6-27
2. VCO Adjustment (SY-089 Board) ································· 6-27
3. Bright Adjustment (SY-089 Board) ······························· 6-28
4. Contrast Adjustment (SY-089 Board) ···························· 6-28
5. Black Limit Adjustment (SY-089 Board) ······················ 6-29
6. V-COM Adjustment (SY-089 Board) ···························· 6-29
7. White Balance Adjustment (SY-089 Board) ················· 6-30
—2—
DSC-V1
SECTION 6
COVER ADJUSTMENTS
Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a
board is replaced.
Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM
to the replaced board.
Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or in-
stalled, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)
6-1
DSC-V1
COVER
Replaced parts
Block Mounted parts Board
replacement replacement replacement
(VIDEO AMP)
(CCD imager)
(LCD panel)
(Back light)
(Laser unit)
EEPROM
(EVR)
(COMPLETE)
(COMPLETE)
Adjustment section Adjustment
Flash unit
LCD901
IC101
IC152
IC304
IC601
IC101
IC801
IC502
D901
D333
ST-083 flexible board
ST-083 flexible board
CD-441 board
SY-089 board
SY-089 board
SY-089 board
SY-089 board
SY-089 board
SY-089 board
SY-089 board
LCD block
LCD block
Table 6-1-1
6-2
DSC-V1
COVER
Fig. 6-1-1
6-3
DSC-V1
1-1-2. Preparations
Pattern box
1) Connect the equipment for adjustments according to Fig. 6-1-3.
2) Start up the application for adjustment (SEUS).
L = About 25 cm
Fig. 6-1-2
HASP Key
To USB connector
To A/V OUT jack
Vectorscope Color monitor
Terminated Video (yellow)
75 Ω
To DC IN jack
Audio (Black)
Fig. 6-1-3
6-4
DSC-V1
1-1-3. Precautions
1. Setting the Switch
Unless otherwise specified, set the switches as follows and per-
form adjustments.
1. Mode Dial ................................................. CAMERA
2. ZOOM button
(MODE-51470 block S101, S105) ........... WIDE end
3. DSPL/LCD ON/OFF button
(GL-51470 block S258) ............................ OSD OFF
4. SMART ZOOM (SET UP setting) ........... OFF
5. VIDEO OUT (SET UP setting) ................ NTSC
2. Order of Adjustments
Basically carry out adjustments in the order given.
Magenta
White
Cyan
Green
C C=D D
Red
Blue
Magenta
Yellow
Green
White
Cyan
Blue
Red
CRT picture frame
V
A B A=B B A
Fig. b (monitor TV picture)
Enlargement
Difference in level
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig a
and the monitor TV display shown in Fig. b.
B A
Fig. 6-1-4
3. Subjects
1) Color bar chart (Standard picture frame).
When performing adjustments using the color bar chart, ad-
just the picture frame as shown in Fig. 6-1-4. (Standard pic-
ture frame)
2) Clear chart (Standard picture frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations dur-
ing this time)
6-5
DSC-V1
1030 mm 1000 mm
(730 mm) (700 mm)
Fig. 6-1-5
woody board A
woody board B
woody board A
woody board B
woody board C
Fig. 6-1-6
6-6
DSC-V1
COVER
Initializing Method:
1) Select page: 00, address: 01 and set data: 01. 4. 4F Page table
2) Click [Page Edit] on the SEUS screen to display the SEUS Note 1: Fixed data-1: Initialized data.
PAGE EDIT screen. (Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
3) Click [Page], and then enter the page to be initialized. Data”)
4) Click [Preset Data Read] to display the Set ID input screen. Note 2: Fixed data-2: Modified data.
5) For page 0E, enter Set ID = “00” and read the initializing data (Refer to step 7 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
on the SEUS PAGE EDIT screen. Data”)
6) For page 2F, 4F and 6F, enter Set ID = “09” and read the ini- Address Initial value Remark
tializing data on the SEUS PAGE EDIT screen.
00 to 81 Fixed data-1 (Initialized data)
7) On the SEUS PAGE EDIT screen, change the data at “Fixed
data-2” address given in the table on the page to be initialized. 82 90 VCO adj. (NTSC mode)
Note: New data for change are not listed in the table. If the 83 9B VCO adj. (PAL mode)
data are to be changed, read and copy the data from the
84 91 V-COM adj.
same model. Copying the data from different models
may cause an operation failure. 85 B2 Bright adj.
8) Confirm that the data at respective adjustment addresses are 86 2D Black limit adj.
the initial values (adjustment initial values) given in the table.
87 Fixed data-1 (Initialized data)
If different, change to the adjustment initial values.
9) Click [Write] to write the initializing data to the set. 88 84
White balance adj.
10) Click [Close] to close the SEUS PAGE EDIT screen. 89 66
8A 3F Contrast adj.
Processing after Completing Initializing
8B to 9F Fixed data-1 (Initialized data)
Order Page Address Data Procedure
A0 80 Composite video level adj.
1 20 00 29 [set]
A1 to A7 Fixed data-1 (Initialized data)
2 20 01 29 [Write] (Note)
A8
Fixed data-2
Note: At this time, the set is reset and the power is turns off once A9
and then on again. Accordingly, the message “Receive AA to FF Fixed data-1 (Initialized data)
Packet Error” is displayed on the SEUS screen, and the
SEUS goes in “disconnect” state, but this is not a trouble.
Click [Connect] on the SEUS screen to restore the “con-
nected” state. (In case that the power does not turn on again,
press the power button.)
6-7
DSC-V1
5. 6F Page Table
Note 1: Fixed data-1: Initialized data. Address Initial value Remark
(Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”) 3C 00
Note 2: Fixed data-2: Modified data. 3D 00 Flange back adj.
(Refer to step 7 of “ 1. Initializing of 0E, 2F, 4F, 6F Page 3E FF
Data”)
3F Fixed data-1 (Initialized data)
Address Initial value Remark
40 00
00 to 0F Fixed data-1 (Initialized data)
41 00
10 58
42 00
11 FF
43 00
12 FF Hologram AF data input
44 00
13 FF
45 00
14 00
46 00
15 to 17 Fixed data-1 (Initialized data)
47 00
18 4C
48 00
19 0F
49 00 Flange back adj.
1A AC
4A 00
1B CA
4B 00
1C 10
4C 00
1D 00
4D 00
1E 00
4E 00
1F 00
4F 00
20 00
50 00
21 00
51 00
22 00
52 00
23 00
53 00
24 20
54 00 Hologram AF data input
25 20
55 to 5F Fixed data-1 (Initialized data)
26 64
60 00
27 46
61 00
28 0A
62 00 F No. compensation
29 00 Flange back adj.
63 00
2A 00
64 00
2B 00
65 30
2C 00
66 FE Light value adj.
2D 00
67 6D
2E 00
68 to 6A Fixed data-1 (Initialized data)
2F 00
6B FF
30 00 F No. compensation
6C 00
31 00 Mechanical shutter adj.
6D 00
32 00
6E 00
33 00 Mixed color cancel adj.
6F 00
34 00
70 29
35 00
71 83
36 00
72 1F
37 00
73 DF
38 00 AWB 3200K standard data input
74 29
39 00
75 0C
3A 00
76 22
3B 00
77 6D
6-8
DSC-V1
6F Page Table
Address Initial value Remark Address Initial value Remark
78 00 A8 D5
79 00 A9 FE
7A 00 AA 73
7B 00 AB 45
Color reproduction adj.
7C 00 AC 63
7D 00 AD 83
7E 00 AE 03
7F 00 AF E9
AWB 3200K standard data input
80 00 B0 00 AWB 3200K standard data input
81 00 B1 00 AWB 5800K standard data input
82 00 B2 00 AWB 3200K standard data input
83 00 B3 00 AWB 5800K standard data input
84 00 B4 00 AWB 3200K standard data input
85 00 B5 Fixed data-1 (Initialized data)
86 00 B6 28
Strobe adj.
87 00 B7 6E
88 19 B8 10
89 66 B9 6B
8A 30 BA 0F
8B 6E BB F6
8C 19 BC 0F
8D A7 BD F7
8E 32 BE 0F
8F FB BF F2
90 00 C0 0F
91 00 C1 F7
92 00 C2 00
93 00 C3 00
94 00 C4 00
95 00 AWB 5800K standard data input C5 00
96 00 C6 00
97 00 C7 30 Mechanical shutter adj.
98 00 C8 1B
99 00 C9 12
9A 00 CA 0D
9B 00 CB 08
9C 00 CC 80
9D 00 CD 88
9E 00 CE 98
9F 00 CF 90
A0 2A D0 88
A1 7E D1 00
A2 5F D2 00
A3 81 D3 00
A4 03 D4 00
A5 E9 D5 00
Color reproduction adj.
A6 63 D6 00
A7 83 D7 14
6-9
DSC-V1
6F Page Table
Address Initial value Remark
D8 FF
D9 FF
DA FF
DB 00
DC 00
DD 00
DE 00
DF 00
E0 00
E1 00
E2 00
E3 00 Strobe adj.
E4 00
E5 00
E6 00
E7 00
E8 00
E9 00
EA 00
EB 00
EC 00
ED 00
EE 00
EF 00
F0 to FF Fixed data-1 (Initialized data)
6-10
DSC-V1
COVER
Adjusting method:
Order Page Address Data Procedure
1 00 01 01 [Set]
2 2F 21 08 [Write]
3 4F 0F 01 [Write]
4 4F 02 03 [Write]
5 60 C1 [Read] Check the data is “01”.
6 40 F1 04 [Set]
Change the data and set
7 4F A0 the sync level (A) to the
specified value.
8 4F A0 [Write] Write this data.
Check the burst level (B)
9
to the specified value.
B
A
Fig. 6-1-7
6-11
DSC-V1
COVER
1-4. CAMERA SYSTEM ADJUSTMENTS After completing the camera system adjustments, release the
Before perform the camera system adjustments, check that the data setting:
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat- 1) Click [Page Edit] on the SEUS screen to display the SEUS
isfied. PAGE EDIT screen.
Note: For “CAMERA SYSTEM ADJUSTMENTS”, perform in 2) Click [Page], and then enter the page “0E”.
order of item numbers. 3) Click [Preset Data Read] to display the Set ID input screen.
4) Enter Set ID = “00” and read the initializing data on the SEUS
Data setting during camera system adjustments PAGE EDIT screen.
Perform the following data setting before the camera system ad- 5) Check that all the data is “FF”.
justments. 6) Click [Write] to write the initializing data to the set.
It is not necessary to perform the following data setting every time 7) Click [Close] to close the SEUS PAGE EDIT screen.
when you perform some items of camera system adjustments con- 8) Release the data setting which has been executed before ad-
tinuously unless the power is turned off. Only when the power is justment.
turned off during this adjustments, perform the data setting again,
then continue the adjustments. Order Page Address Data Procedure
1 4F 01 00 [Write]
Set up setting:
2 7F 68 40 [Write]
1) VIDEO OUT of SET UP setting............... NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don't 3 75 0A 00 [Write]
set the SET UP setting to “PAL”) 4 60 6C 00 [Set]
5 4F 02 00 [Set]
Data setting method 6 2F 21 00 [Write]
7 4F 0F 00 [Write]
Order Page Address Data Procedure
8 00 01 00 [Set]
1 00 01 01 [Set]
2 4F 01 20 [Write]
3 7F 68 00 [Write]
4 75 0A 04 [Write]
5 20 00 29 [Set]
6 20 01 29 [Write] (Note 1)
7 00 01 01 [Set]
8 4F 0F 01 [Write]
9 2F 21 0B [Write]
Check the data changes
10 60 C1 [Read]
to “02”.
11 4F 02 03 [Set]
12 60 6C 01 [Set]
13 Wait for 1 second.
Note 1: At this time, the set is reset and the power is turned off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click [Connect] on the SEUS screen to restore
the “connected” state. (In case that the power does not
turn on again, press the power button.)
Note 2: Repeat the “Data setting method”, if the power was turned
off and on during the “CAMERA SYSTEM ADJUST-
MENTS”.
6-12
DSC-V1
Picture Frame Setting How to reset the zoom and focus when they deviated:
Mode CAMERA Order Page Address Data Procedure
Subject Color bar chart 1 60 2C 01 [Set]
(Standard picture frame with the 2 60 90 00 [Set]
zoom lens at WIDE end)
3 60 91 00 [Set]
Measurement Point Video terminal of A/V OUT jack
(75 Ω terminated) 4 60 92 YL [Set] (Note)
Setting method:
Check on the oscilloscope
Order Page Address Data Procedure
Shoot the color bar chart 1. Horizontal period
1 with the zoom WIDE
A=B C=D
end.
2 60 8C 30 [Set] B C
Enter the output of A D
VIDEO OUT to the
3 monitor TV, and move
the position as shown in
Fig. 6-1-10.
Horizontal width of one
color (B, C) and that of
4 black (A, D) on the color
bar chart should be same.
(See Fig. 6-1-8)
With vertical width of
black (E, F) set in same,
the color bar chart
5
should come to the
center of monitor TV.
(See Fig. 6-1-9)
Fig. 6-1-8
Check that the color bar
6 on the monitor TV is 2. Vertical period
focused.
Read the data. E E=F F
7 10 44 [Read] Note down the data, and
this is named YH data.
Read the data.
8 10 45 [Read] Note down the data, and
V
this is named YL data.
Fig. 6-1-9
Processing after Completing Adjustments:
Order Page Address Data Procedure Check on the monitor TV
1 60 8C 00 [Set]
6-13
DSC-V1
Below 3 cm
Minipattern box
Camera
Camera
table
Red (+)
Black (–)
Yellow (SENS +)
Fig. 6-1-11
6-14
DSC-V1
6-15
DSC-V1
Adjusting method: Note 1: Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Order Page Address Data Procedure Note 2: 2byte data is upper 1byte data and lower 1 byte data.
1 Perform “Data setting XX XX
during camera system Lower 1byte data (Page: 10, address: 0D)
adjustment”. Upper 1byte data (Page: 10, address: 0C)
(Refer to page 6-12)
Adjusting method:
Perform “Picture frame
2 setting” Order Page Address Data Procedure
(Refer to page 6-13) Perform “Data setting
3 60 01 AD [Write] (Note 2) during camera system
1
Check the data changes adjustment”.
4 60 02 [Read] (Refer to page 6-12)
to “01”.
Check that the data Perform “Picture frame
5 6F 6B [Read] satisfied the specified 2 setting”
value. (Refer to page 6-13)
Note 2: The adjustment data will be automatically input to page: 3 60 01 0D [Write] (Note 3)
6F, address: 6B to 6D and B8 to D7. Check the data changes
4 60 02 [Read]
to “01”.
Processing after Completing Adjustments: Read the data
5 10 0C [Read]
Order Page Address Data Procedure (Upper 1byte).
1 60 01 00 [Write] Read the data
6 10 0D [Read]
(Lower 1byte).
Release “Data setting
during camera system Check that the 2byte
2 7 data (Note 2) satisfied
adjustment”
(Refer to page 6-12) the specified value 1.
Check that the data
8 6F 65 [Read] satisfied the specified
value 2.
Note 3: The adjustment data will be automatically input to page:
6F, address: 65 to 67.
6-16
DSC-V1
6-17
DSC-V1
6-18
DSC-V1
6-19
DSC-V1
Order Page Address Data Procedure Order Page Address Data Procedure
26 77 72 54 [Set] The data reverts back to
60 75 22 [Read]
27 Wait for 2 seconds. the first.
28 60 01 F9 [Write] The data reverts back to
61 75 23 [Read]
the first.
Check the data changes
29 60 E1 [Read] The data reverts back to
to “08”. 62 75 24 [Read]
the first.
Read the data
30 10 80 [Read] The data reverts back to
(Upper 1byte). 63 75 25 [Read]
the first.
Read the data
31 10 81 [Read] Convert D1, D2, D3, D4,
(Lower 1byte).
D5, D6 to decimal
This 2byte data (Note) is 64
32 notation, and obtain D1’,
named D3. D2’, D3’, D4’, D5’ D6’.
Read the data
33 10 82 [Read] Calculate S1, S2, S3, S4
(Upper 1byte). using following
Read the data equations.
34 10 83 [Read]
(Lower 1byte). (Decimal calculation)
65
This 2byte data (Note) is S1 = (D3’ ÷ D1’) × 100
35 S2 = (D4’ ÷ D2’) × 100
named D4.
S3 = (D5’ ÷ D1’) × 100
36 60 01 00 [Write]
S4 = (D6’ ÷ D2’) × 100
37 60 E1 00 [Set]
Check that the S1 and S2
38 60 12 A2 [Set] 66 satisfies the specified
39 77 72 09 [Set] value 1.
40 Wait for 2 seconds. Check that the S3 and S4
67 satisfies the specified
41 60 01 F9 [Write]
value 2.
Check the data changes
42 60 E1 [Read]
to “08”.
Processing after Completing Adjustment:
Read the data
43 10 80 [Read] Order Page Address Data Procedure
(Upper 1byte).
Read the data Release “Data setting
44 10 81 [Read] during camera system
(Lower 1byte). 1
adjustment”
This 2byte data (Note) is (Refer to page 6-12)
45
named D5.
Read the data
46 10 82 [Read]
(Upper 1byte).
Read the data
47 10 83 [Read]
(Lower 1byte).
This 2byte data (Note) is
48
named D6.
49 60 01 00 [Write]
50 60 E1 00 [Set]
51 60 12 00 [Set]
52 60 14 00 [Set]
The data reverts back to
53 75 09 [Read]
the first.
The data reverts back to
54 77 F6 [Read]
the first.
The data reverts back to
55 77 F7 [Read]
the first.
The data reverts back to
56 77 F2 [Read]
the first.
The data reverts back to
57 77 72 [Read]
the first.
58 60 05 00 [Set]
The data reverts back to
59 75 21 [Read]
the first.
6-20
DSC-V1
Adjusting method: YE W
B-Y
Order Page Address Data Procedure
B
Perform “Data setting
during camera system
1
adjustment”.
(Refer to page 6-12)
Perform “Picture frame
G
2 setting” CY
(Refer to page 6-13)
3 7F 68 00 [Set] Burst position
4 6F B5 FF [Write]
5 60 01 AB [Write]
6 60 12 80 [Write] Fig. 6-1-12
7 Wait for 1 seconds.
8 60 12 00 [Write]
9 Wait for 2 seconds.
10 60 01 A9 [Write] (Note 2)
Check the data changes
11 60 02 [Read]
to “01”.
Check that the data
12 6F B5 [Read] satisfied the specified
value.
Check the each color
luminance point is in
13
each color reproduction
frame.
Note 2: The adjustment data will be automatically input to page:
6F, address: A4 to AF.
6-21
DSC-V1
Adjusting method:
Order Page Address Data Procedure
Perform “Data setting
during camera system
1
adjustment”.
(Refer to page 6-12)
2 7D 64 1E [Set]
3 7D 69 18 [Set]
4 60 01 8B [Write]
Check the data changes
5 60 02 [Read]
to “01”.
Check the data.
6 60 55 [Read] 00 to 7F: Normal
80 to FF: Defective
7 60 01 00 [Write]
8 7D 64 0F [Set]
9 7D 69 60 [Set]
10 60 01 87 [Write]
Check the data changes
11 60 02 [Read]
to “01”.
Check the data.
12 60 55 [Read] 00 : Normal
01 to FF: Defective
6-22
DSC-V1
Adjusting method:
Order Page Address Data Procedure
Perform “Data setting
during camera system
1
adjustment”.
(Refer to page 6-12)
Perform “Picture frame
2 setting”
(Refer to page 6-13)
3 7D 65 4C [Set]
4 60 90 00 [Set]
5 60 91 03 [Set]
6 60 92 00 [Set]
7 60 93 00 [Set]
8 60 01 79 [Write]
9 60 30 08 [Set]
Check the data changes
10 60 07 [Read]
to “01”.
11 60 01 8D [Write]
Check the data changes
12 60 02 [Read]
to “01”.
Check the data.
00: Proceed to “Process-
ing after Completing
13 60 55 [Read]
Adjustment”
00 to 14 : Normal
15 to FF : Defective
14 60 01 00 [Write]
15 7D 65 5A [Set]
16 60 01 89 [Write]
Check the data changes
17 60 02 [Read]
to “01”.
Check the data.
18 60 55 [Read] 00 : Normal
01 to FF : Defective
6-23
DSC-V1
6-24
DSC-V1
Input method:
Order Page Address Data Procedure
1 00 01 01 [Set]
2 6F 10 91 [Write]
3 6F 11 00 [Write]
4 6F 12 00 [Write]
5 6F 13 00 [Write]
6 6F 14 00 [Write]
7 6F 54 00 [Write]
6-25
DSC-V1
Fig. 6-1-13
6-26
DSC-V1
COVER
6-27
DSC-V1
6-28
DSC-V1
B A
A B
B A
A B
Fig. 6-1-14
6-29
DSC-V1
Adjusting method:
Order Page Address Data Procedure
1 00 01 01 [Set]
2 40 F1 0A [Set]
Write the data.
3 4F 88 84 [Write]
(Initial value)
Write the data.
4 4F 89 66 [Write]
(Initial value)
Check that the LCD
screen is not colored. If
not colored, proceed to
5
“Processing after
Completing Adjust-
ments”.
Change the data so that
88 the LCD screen is not
6 4F [Write]
89 colored, and write this
data.
6-30
DSC-V1
COVER
Fig. 6-2-1
6-31
DSC-V1
COVER
In some adjustment items, the calculation of SEUS displayed data 1. Setting the Test Mode
(hexadecimal) is needed to check the specified data or to acquire
the adjustment data. In such a case, prepare a computer capable of Page 2F Address 21
calculating hexadecimal numbers.
Also, the data at two addresses are read, which are treated as 2 Data Function
bytes of upper 1 byte and lower 1 byte (4-digit hex. number), to
check the specified data. 00 Normal
01 Forced S (shutter speed) mode
XX XX
02 Forced A (aperture) mode
03 Forced M (manual) mode
04 Forced SCN (scene selection) mode
Displayed data at lower 1 byte address 05 Forced MOVIE mode
Displayed data at upper 1 byte address 08 Forced PLAY mode
09 Forced SET UP mode
0A Forced CAMERA (auto) mode
0B Forced P (program) mode
• Before setting the data, select page: 00, address: 01, and set
data: 01.
• In the case of page 2F, writing the data by clicking [Write] on
the SEUS screen causes the data to be written to the nonvolatile
memory. In this case, the Test mode is not released even if the
set is turned off, thus requiring extreme care.
• After the adjustment/repair finished, be sure to return the data
to “00” to restore the Normal mode. Also, select page: 00, ad-
dress: 01, and set data: 00.
6-32
DSC-V1
00 lit.
3) Select page: 20, address: 04, set data: 00.
Using method:
1) Select page: 20, address: 80.
2) By discriminating the bit value of read data, the state of the
switches can be discriminated.
6-33
DSC-V1
Page 20 Addresses 91 to 95
Using method:
1) Select page: 20, addresses: 91 to 95.
2) By discriminating the read data, the pressed key can be dis-
criminated.
Data
Address
00 to 0C 0D to 27 28 to 48 49 to 73 74 to DC DD to FF
IMAGE SIZE/
91 MENU CONTROL DOWN CONTROL RIGHT
DELETE
(KEY AD0) (GL-51470 block) (GL-51470 block) (GL-51470 block) (GL-51470 block) No key input
(IC402 tg) (S251) (S252) (S253) (S254)
DISPLAY/LCD
92 CONTROL UP CONTROL SET CONTROL LEFT
ON/OFF
(KEY AD1) (GL-51470 block) (GL-51470 block) (GL-51470 block) (GL-51470 block) No key input
(IC402 th) (S255) (S256) (S257) (S258)
EXECUTE EXPOSURE/
93 FOCUS AE LOCK
(JOG DIAL) INDEX
(KEY AD2) (MODE-51470 block) (GL-51470 block) (GL-51470 block) (GL-51470 block) No key input
(IC402 tj) (S106) (S259) (S260) (S261)
94 ZOOM DOWN ZOOM UP NIGHT SHOT NIGHT FLAMING
(KEY AD3) (MODE-51470 block) (MODE-51470 block) (MODE-51470 block) (MODE-51470 block) No key input
(IC402 tk) (S101) (S105) (S102) (S102)
LENS ADAPTOR
95
DETECT
(KEY AD4) (SW-395 flexible) No key input
(IC402 tl) (S101)
Using method:
1) Select page: 20, address: 80 and 81.
2) By discriminating the bit value of read data, the state of the
switches can be discriminated.
6-34
DSC-V1
Using method:
1) Select page: 20, addresses: 90 and 96.
2) By discriminating the read data, the pressed key can be discriminated.
Data
Address
00 to 0C 0D to 27 28 to 48 49 to 73 74 to DC DD to FF
90 S (shutter speed) A (aperture) M (manual) SCN (scene selection) MOVIE
(MODE DIAL) (MODE-51470 block) (MODE-51470 block) (MODE-51470 block) (MODE-51470 block) (MODE-51470 block) others
(IC402 tf) (S108) (S108) (S108) (S108) (S108)
96 CAMERA (auto) P (program)
(MODE DIAL 2) (MODE-51470 block) (MODE-51470 block) others
(IC402 y;) (S108) (S108)
C:32:ss Turn the power off and on again. Trouble with hardware. SYSTEM ERROR
Format the “Memory stick”. Unformatted memory stick is inserted. FORMAT ERROR
C:13:ss
Insert a new “Memory Stick”. Memory stick is broken. MEMORY STICK ERROR
When failed in the focus and zoom
E:61:ss Checking of lens drive circuit.
initialization.
—
Checking of flash unit or replacement Abnormality when flash is being
E:91:ss
of flash unit. charged.
6-35
DSC-V1
AF ILLUMINATION CHECK Take a reduced or enlarged copy on the clear sheet so that a
rectangular frame of the SHEET FOR AUXILIARY LIGHT
is suitable for the effective image size of the monitor.
DSC-V1
6-36
DSC-V1
R-Y
R MG
YE W
B-Y
B
G
CY
✄ DSC-V1
✄
6-37E
6-37
Reverse 987626151.pdf
Revision History
S.M. Rev.
Ver. Date History Contents
issued
1.0 2003.05 Official Release — —