You are on page 1of 10

1/1

1570

Inlet Outlet

810

100
Plan View

Ø 50 Vent Pipe
(Typ 2)

Flow Direction
K/O
300 x 510
Panel
Each
800 1065 End
1165

610

225
130

250 880 250 610


1380

Side View End View

General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Designed for Roadway Use - H-20 Traffic Loading
⋅Installation of T-Pipe Assemblies Recommended - Supplied & Installed by Others.
⋅Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅Up-gradable with Facet "M-Pak" Coalescing Plate System - Design/Build
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others
Scale 1:20 mm
Model 24x54 Oil Interceptor {API}
Oil Int. Wgt: 1,130 kgs / 2,480 lbs
A.E. CONCRETE
®
Con-Force Division of Armtec Limited Partnership Baffles Wgt: 60 kgs / 130 lbs
Office: 19060 - 54th Ave. Surrey, BC V3S 8E5
Tel (604) 576-1808 Fax (604) 576-2454 Rev: 28Jun08
Shipping: 5353 - 192nd St. Surrey, BC V3S 8E5
Website: www.ae-concrete.com Dwg#: 24OI-20-1420-API-C
1/1

2695

Ø 915
Ø 620

1190

Plan View

760Ø MH Casting (C-23/23A) 508Ø MH Casting (C-18)


H-20 Traffic Load Rated
181

188

South Elevation East Elevation

General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Designed for Roadway Use - H-20 Traffic Loading
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others

Scale 1:25 mm
Model 385 Roof Slab w/ Circular Openings {CPS}
Wgt: 1,070 kgs / 2,350 lbs
® A.E. CONCRETE
Con-Force Division of Armtec Limited Partnership
Office: 19060 - 54th Ave. Surrey, BC V3S 8E5
Tel (604) 576-1808 Fax (604) 576-2454
Rev: 28Jun08
Shipping: 5353 - 192nd St. Surrey, BC V3S 8E5
Website: www.ae-concrete.com Dwg#: 35OI-AC-2400-C
1/1

2695

1270
410

660 410 1190

Bolt Down Painted Steel


Plan View
Checker Plate Covers
(Galvanizing Available)

Boulevard Use Only


H-20 Static Load Rated

188

South Elevation East Elevation

General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Designed for Boulevard (Off-Road) Use - H-20 Static Loading
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others
Scale 1:25 mm
Model 385 Roof Slab w/ Model 243 Lid Assembly
Wgt: 1,130 kgs / 2,470 lbs
® A.E. CONCRETE
Con-Force Division of Armtec Limited Partnership
Office: 19060 - 54th Ave. Surrey, BC V3S 8E5
Tel (604) 576-1808 Fax (604) 576-2454
Rev: 28Jun08
Shipping: 5353 - 192nd St. Surrey, BC V3S 8E5
Website: www.ae-concrete.com Dwg#: 35OI-A6-2400-C
1/1

2695

1190

Ø 620 Typ

Plan View

H-20 Traffic Load Rated


508Ø MH Casting (C-18)

181

188

South Elevation East Elevation

General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Designed for Roadway Use - H-20 Traffic Loading
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others
Scale 1:25 mm
Model 385 Roof Slab w/ Circular Openings
Wgt: 1,270 kgs / 2,790 lbs
® A.E. CONCRETE
Con-Force Division of Armtec Limited Partnership
Office: 19060 - 54th Ave. Surrey, BC V3S 8E5 Rev: 28Jun08
Tel (604) 576-1808 Fax (604) 576-2454
Shipping: 5353 - 192nd St. Surrey, BC V3S 8E5
Website: www.ae-concrete.com Dwg#: 35OI-A2-2400-C
1/1
1795

1190

Ø 620
(Typ 2)

H-20 Traffic Load Rated


Plan View 508Ø MH Casting (C-18)
181

188

Side View End View

1795

Bolt Down Painted Steel


Checker Plate Covers
1190 (Galvanizing Available)

Plan View
Boulevard Use Only
H-20 Static Load Rated

188

1270 660
Front View End View

General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others
Scale 1:20 mm
Model 355 Lid Assemblies
Roof Slab Wgt: 740 kgs / 1,620 lbs
® A.E. CONCRETE
Con-Force Division of Armtec Limited Partnership
Hatch R/S Wt: 720 kgs / 1,580 lbs
Office: 19060 - 54th Ave. Surrey, BC V3S 8E5
Tel (604) 576-1808 Fax (604) 576-2454
Rev: 28Jun08
Shipping: 5353 - 192nd St. Surrey, BC V3S 8E5
Website: www.ae-concrete.com
Dwg#: 24OI-A2-1500-C
1/1

Inlet Outlet

Plan View

Flow Direction

600 x 600 x 75
1640 K/O Panel
Each End
1125

1525
915

150

450 1495 450 900


2395
End View
Side View

General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Designed for Roadway Use - H-20 Traffic Loading
⋅Installation of T-Pipe Assemblies Recommended - Supplied & Installed by Others.
⋅Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others

Scale 1:25 mm
Model 385 Oil Interceptor {CPS}
Oil Int. Wgt: 4,170 kgs / 9,180 lbs
® A.E. CONCRETE
Con-Force Division of Armtec Limited Partnership
Baffles Wgt: 130 kgs / 280 lbs
Office: 19060 - 54th Ave. Surrey, BC V3S 8E5
Tel (604) 576-1808 Fax (604) 576-2454
Rev: 28Jun08
Shipping: 5353 - 192nd St. Surrey, BC V3S 8E5
Website: www.ae-concrete.com Dwg#: 35OI-20-2400-CPS-C
1/1

Inlet Outlet

Plan View

Flow Direction

600 x 600 x 75
1640 K/O Panel
Each End
1125

1525
1525
915

150

450 1495 450 900


2395
End View
Side View

General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Designed for Roadway Use - H-20 Traffic Loading
⋅Installation of T-Pipe Assemblies Recommended - Supplied & Installed by Others.
⋅Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅Up-gradable with Facet "M-Pak" Coalescing Plate System - Design/Build
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others
Scale 1:25 mm
Model 385 Oil Interceptor {API}
Oil Int. Wgt: 4,170 kgs / 9,180 lbs
® A.E. CONCRETE
Con-Force Division of Armtec Limited Partnership
Baffles Wgt: 130 kgs / 280 lbs
Office: 19060 - 54th Ave. Surrey, BC V3S 8E5
Tel (604) 576-1808 Fax (604) 576-2454
Rev: 28Jun08
Shipping: 5353 - 192nd St. Surrey, BC V3S 8E5
Website: www.ae-concrete.com Dwg#: 35OI-20-2400-API-C
1/1

1780

Inlet Outlet

1170

150
Plan View
Ø 50 Vent Pipe
(Typ 2)

Flow Direction

600 x 600 x 75
K/O Panel
Each End

1175 1525
1640

915

495

150

300 900 300 900


1500 End View
Side View

General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Designed for Roadway Use - H-20 Traffic Loading
⋅Installation of T-Pipe Assemblies Recommended - Supplied & Installed by Others.
⋅Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others

Model 355 Oil Interceptor {API} Scale 1:25 mm


Oil Int. Wgt: 2,970 kgs / 6,530 lbs
® A.E. CONCRETE
Con-Force Division of Armtec Limited Partnership
Steel Baffles: 130 kgs / 280 lbs
Office: 19060 - 54th Ave. Surrey, BC V3S 8E5
Tel (604) 576-1808 Fax (604) 576-2454
Rev: 28Jun08
Shipping: 5353 - 192nd St. Surrey, BC V3S 8E5
Website: www.ae-concrete.com
Dwg#: 35OI-20-1500-C
1/1

1795

1190

Ø 620 Typ.
H-20 Traffic Load Rated.
508Ø MH Casting (C-18)
Plan View - Roof Slab
181

188

Side View - Roof Slab End View - Roof Slab

Boulevard Use,
H-20 Static Load Rated.

Optional: Perforated Lid


Checker Plate Covers

General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others
Scale 1:20 mm
Model 24x54 Lid Assemblies
Roof Slab Wgt: 740 kgs / 1,620 lbs
® A.E. CONCRETE
Con-Force Division of Armtec Limited Partnership
Steel Chk. Plt. Wt: 111 kgs / 244 lbs
Office: 19060 - 54th Ave. Surrey, BC V3S 8E5
Tel (604) 576-1808 Fax (604) 576-2454
Rev: 28Jun08
Shipping: 5353 - 192nd St. Surrey, BC V3S 8E5
Website: www.ae-concrete.com
Dwg#: 24OI-A1-1420-C
1/1

1570

Inlet Outlet

810

100
Plan View

Ø 50 Vent Pipe
(Typ 2)

Flow Direction

K/O
300 x 510
Panel
Each
800

1065 End
1165
Facet M-Pak
610

225
130

250 880 250 610


1380

Side View End View

General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Designed for Roadway Use - H-20 Traffic Loading
⋅Installation of T-Pipe Assemblies Recommended - Supplied & Installed by Others.
⋅Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others

Scale 1:20 mm
Model 24x54 Oil Separator {CPS}
Oil Sep. Wgt: 1,130 kgs / 2,480 lbs
® A.E. CONCRETE
Con-Force Division of Armtec Limited Partnership
Baffles Wgt: 60 kgs / 130 lbs
Office: 19060 - 54th Ave. Surrey, BC V3S 8E5
Tel (604) 576-1808 Fax (604) 576-2454
Rev: 28Jun08
Shipping: 5353 - 192nd St. Surrey, BC V3S 8E5
Website: www.ae-concrete.com Dwg#: 24OI-20-1420-CPS-C