[Version: D]
MN000003108
Preface
Operation procedure
Start
Safety
Reference information Page 2
precautions
Page
Specifications and
Pages Installation Page 4 precautions for
2-5 preparations card operations
Operation
p rules
for plugging /
Page 5 unplugging optical
Installing modules
Page 6
cabinets
Subrack
Page 6
overview
Pages Connecting
15-23 cables
Installing
Page 27
Pages Connecting cabinet doors Checking the
24-26 fiber jumpers Page 27 connection and
layout of wires
and cables
Pages Post-installation Checking before
27-28 inspection Page 28
power-on
11
2 Safety Precautions
Warning
Laser Safety
To prevent laser radiation from injuring eyes, do not look into the
end face of the fiber or fiber connector directlly with naked eyes. Laser class
identifier
Caution
ESD Protection
Carpets or other materials that easily gene
erate static electricity should not be used on the floor
of the equipment room.
Do not touch any component or wires on cards,
c or metal conductors in sockets. ESD protection
measures should be taken if it is necessarry to touch the card during maintenance.
Caution
Binding Cables
Cables of different types on the installation
n site should be laid out independently and bound
separately. Please note that optical fibers should be bound with dedicated fiber binding straps.
Exercise care if you must bend fibers. If bends
b are necessary, the fiber bending radius should
never be less than 20 d (d refers to the fibber diameter).
The
Th cables
bl are bbound d with
i h proper andd equuall spacing
i b between them.
h The cable
Th binders
bl bi d are
arranged in good order. The extra parts off the binders are cut from the root without leaving sharp
points.
Caution
Inspection Prior to Installation
Prior to equipment installation, please inspecct the equipment room, cabinet, power supply,
connection of cables (especially earth ground d cable), and supporting facilities. After confirming
that the conditions for installation are satisfacctory, start the work following the project designing
documents. Please refer to the manual Installlation Reference for details.
22
3 Installation Tools
Cable tie
ESD protection gloves ESD protection wrist strap Insulating tape Fiber binding strap
3
4 Specifications and Precautions forr Card Operations
Caution
Do not contact cards with bare hands. Alw
ways wear ESD protection gloves or ESD protection
wrist strap when operating on cards.
When holding a card, put your hands on itts panel, and do not touch any component or wires on
cards, or metal conductors in sockets.
All vacant slots in the subrack should be innstalled with dummy panels. When you unplug
a dummy panel, ensure that you will plug it back in five minutes.
Use care when plugging a card. The card cannot be inserted if not properly oriented.
The cards are valuable and fragile. Users should treat them with great care.
Prevent the circuit surfaces of cards from contacting each other, to avoid shorting or
scratching.
If the unpacked card is a spare card, it willl not be installed immediately. Users can put
the card with its original ESD protection baag in a dry and cool place, keeping it away
from sunlight and strong electromagnetic radiation
r sources.
44
5 Operation Rules for Plugging / Unplugging Optical Modules
1 Hold the optical module, and plug it into the card along
the EMI cage.
Material Order
number number
Working wavelength
wrist strap
Rate 电
手
套
/
腕
带
Pulling the
optical module
(tweezers)
Pulling the
optical
p fiber
55
6 Installing Cabinets
Note
The AN5516-04 can be installed in the followwing cabinets. Please refer to the following
manuals for the procedures of installing the cabinets.
7 Installing Subracks
Subrack Dimensions
66
7.2 Equipment Layout
When multiple AN5516-04 subracks are to be installed in a cabinet, usually arrange them from the
top down.
The AN5516-04 subrack supports both DC pow wer supply and AC power supply. The equipment
layouts in the two cases are different.
A cabinet can house three AN5516-04 subrackks at most.
The subracks are mounted on the front vertical mounting flanges in both 19-inch and 21-inch
cabinets.
The distance between every three mounting ho oles on the front vertical mounting flange in a 19-inch
cabinet is 1 U (44.45 mm).
The distance between every two mounting hole es on the front vertical mounting flange in a 21-inch
cabinet is 1 SU (25 mm).
mm)
Note: 1U = 44.45 mm
Note: 1U = 44.45 mm
77
Example of Arranging Subracks in a 21-inch Cabin
net (AC Power Supply)
Unit: mm
E
Example
l off Arranging
A i Subracks
S b k in
i a 21-inch
21 i h CCabin
binett (DC Power
P Supply)
S l )
Unit: mm
88
7.3 Installing Subrack in 19-inch Cabinet
Installing Components
Mark the positions for mounting the Install the slide rails.
subrack and slide rails on the vertical
mounting flanges of the cabinet. Then Panel screw
install the floating nuts.
M6
Panel screw
Push the subrack into the
cabinet along the slide rails. M6
M6
6
99
7.4 Installing Subrack in 21-inch Cabinet
Installing Components
Installation steps
3 Install the adapter mounting ears. 4 Push the subrack into the cabinet along
g the
Panel screw
slide rails.
5 Tighten the panel screws clockwise to
M6 secure the subrack.
Panel screw
M6
Tip
Flat
Marker pen screwdriver
Cross
screwdriver Panel screw
10
90
7.5 Mounting Subrack on the Wall
Marker pen
Drilling bit
Expansion
bolt
Unit: mm M8 Vacuum
cleaner
3 Install the wall mounting
ears.
Screw
M4
Claw
hammer
C
Cross
Tighten the screws on the screwdriver
4 mounting ears with a wrench
to secure the subrack.
Screw
M4
Socket
wrench
11
111
8 Installing Cards and Components
1 Hold the fan unit and align the slide rails on the
upper and lower sides of the fan unit with the e slide
rail grooves for the fan unit on the subrack
respectively.
12
122
9 Preparations for Cable Connection
n
Note
Internal cables are the wires and cables th hat are connected inside the cabinet. These cables
are usually connected before delivery. Insstallers should check the connection of internal cables
on site. The items to check include whether the cable distribution is reasonable, whether the
wires and cables are properly and neatly arranged,
a whether the plugs are connected firmly,
whether incorrect insertion or poor insertioon exists, and whether any part is missing.
The installers can choose the top access wiring mode or the floor access wiring mode
according to the equipment room and the installation site conditions (This guide uses the top
access wiring mode as an example for de escription).
The AN5516
AN5516-04 04 can use the PDP296B (3000068).
000068) Please refer to Hardware Description for the
DP.
specifications and pin definitions of the PD
Tip
Before laying out wires and cables, you ne eed to remove the front panel of the PDP. If space is
limited for operations, remove the baffle at
a the bottom of the PDP.
After you have completed layout of wires and cables, restore the front panel and baffle to their
original places.
Caution
uence.
Prepare the holes from near to far in sequ
Polish the raw edges of holes so that theyy will not cut hands or cables.
L M R
Pierce the cover plate
with diagonal pliers
along the edges desired
for making a wiring hole
13
133
10 Cabinet with Routed Fibers and Cables
C
14
144
11 Connecting Power Cables and Pro
otection Earth Ground Cables
Cross
screwdriver Screw
M6
Warning
hut off before connecting the power cable. Do not
Make sure the external power supply is sh
connect the power cable when it is powered.
Make sure the DC input is cut off; identifyy the switches to be used.
er cable and the power connector unless necessary.
Never expose the joining part of the powe
ound cable of the equipment and the ground bar is
If the bonding resistance between the gro
ould be re-arranged.
larger than 0.1 ohm, the ground cable sho
Caution
With the premise that the cables must be arranged in compliance with the route, the power
cables (including ground cables) should be
b processed on site according to the “shortest” route
principle.
ontinuous segment of copper core with no
The power cables should be made of a co
intermediate connections.
15
155
Connection
PDP End
CableNote 1 Opposite End
PDP296B (3000068)
0V power cable (b
black)
0V_A terminal (active)
External power earth ground
0V_B terminal (standby)
Bus bar
St
Structure
t IInstallation
t ll ti
Insulating
sleeve
Shorting bar
Tip
The protection earth ground cable for the PD
DP has been connected with the PE terminal before
delivery of the PDP; users need only to conn
nect the other end of the cable to the earth ground
point on the cabinet top.
Note
The following introduces how to connect the cabinet power cables when the PDP296B (3000068) is
used.
16
6
Top
view
2
Wiring hole
2 Lea
ad the power cable into the cabinet.
3 Remove
R the front panel of the PDP.
M3
17
7
11.3 Connecting the Subrack Protection Eartth Ground Cable
Flat Cross
Subrack protection earth ground cable Marker pen screwdriver screwdriver Panel screw
M6
Uninsulated ring
tongue crimped
terminal
Uninsulated ring
tongue crimped
terminal
Caution
Completely insert the cord end terminals into the terminal blocks on the PDP. To ensure good
connection, the metal part exposed shou uld not exceed one sixth of the overall metal length.
The length of exposed insulation covering or metal part of terminals in the same row or batch
should be equal whenever possible.
he cord end terminals, which may result in poor
Do not press the insulation covering of th
electrical
e ec ca co connection.
ec o
Make sure the side with larger area of thee cord end terminal contacts with the terminal block.
Caution
8
18
Caution
Make sure that the power control switches for the corresponding
subrack on the PDP are placed in the OFF po osition.
Note
The subrack power cable is shown in the table below.
Subrack Power
RD Card
Power Interface on the PWR Power Cable Equipped
Cable
DC power cable
Cross Flat
screwdriver screwdriver
1 Connect the blue and black cord end terminals of the subrack power cable to the corresponding
interfaces on the PDP. Connection of the subrack power cables for the AN5516-04 on the PDP side
may vary with the PDP used. Refer to the table below for details.
P wiring hole on the top of the cabinet. Route the
2 Lead the subrack power cable through the PDP
power cable to the power interface of the powerr card in the subrack along the wire channels on the
side of the cabinet.
3 Insert the D-type two-conductor connector of the
e subrack power cable into the power interface of the
PWRD card, and tighten the screws clockwise.
Connection
Connection Descriptio
on
Cable Connector
PDP296B (3000068)
Cord end terminal Connected to the -48V__A_1 to 48V_A_3 terminals (active) and -48V_B_1
(-48 V, blue) to -48V_B_3 terminals (standby)
( on the PDP.
Cord end terminal Connected to the 0V_AA_1 to 0V_A_3 terminals (active) and 0V_B_1 to
(0 V, black) 0V_B_3 terminals (stan
ndby) on the PDP.
19
9
12 Connecting the Alarm Cable
12.2 Connecting the Alarm Cable for the Heaad of Row Cabinet
Connection
Connection
Cable Connector
Description
Three-conductor Connected to the head
Call (brown): Outputs the order wire call. cable of row cabinet.
Nua (black): Outputs the non-urgent alarm
D-type three- Connected to the XP1
signal.
Ua (blue): Outputs the urgent alarm signal. conductor connector terminal on the PDP.
20
0
13 Connecting the E1 Cable
Cross
screwdriver
Connected 1 Thread the E1 cable through the wiring hole at the
to the DDF top of the cabinet, and route it downward along the
wiring channel at the side of the cabinet.
1 :
nector
Conn Connected To
1 Bare wire
w External clock equipment
The CLK IN1 / CLK IN2 / CLK OUT
SAALL type interface on the C155A /TIMA card
ector
conne The CLK IN / CLK OUT interface on the
CE1B card
1 Lead
L the clock cable through the wiring hole at the top
of
o the cabinet, and route it downwards along the wiring
2 channel
ch l att the
th side
id off th
the cabinet.
bi t
2 Thread
T the clock cable through the fiber passage unit
on
o the subrack, and route it to the C155A /TIMA/CE1B
card.
c
3 nsert the SAA series L-type connector of the cable into
In
he clock interface of the C155A / TIMA/CE1B card.
th
SAA series
3 L-type coaxia
al
connector
1
21
15 Connecting the 64-conductor Audio Interface Cable
2 Pre-tighten the screw: Tighten the screw with moderate force, making sure that the screwdriver is
on the same line with the screw.
Caution
Please select an appropriate tool. It is adviised to use a flat screwdriver or a screwdriver set with
1# screwdriver head. The diameter of the screwdriver
s (metal rod) is no larger than 4 mm.
Do not operate forcefully while tightening the screw. Make sure that the moment of force is no
larger than 2.5 Kgf.cm.
2
22
16 Connecting the Network Cable
Connection
Caution
Ensure that the network cable and other cablees have a proper surplus in the section between the
connector and the nearest banding point, so that stress will not be produced at the connector
and that the cable can be easily plugged or un
nplugged.
23
3
17 Connecting the Optical Fiber Jumper
Note
Select the right type of the optical fiber jumper according to the type of the optical interfaces on the
local equipment and opposite end equipment.. The optical interfaces on the AN5516-04 correspond
to two types of optical fiber connectors: LC/PC C and SC/PC (SC/APC).
LC/PC Type Optical Fiber SC/PC Typee Optical Fiber SC/APC Type Optical Fiber
Connector Connector Connector
Caution
See the table below for the major specifications and
a appearance of the commonly used LC/PC and
SC/PC optical fiber connectors. When the equipm ment is mounted in a 300 mm-deep cabinet, it is
advisable to use the short optical fiber connectorss.
LC/PC 31 mm 48 mm
SC/PC 39 mm 55 mm
Caution
The open corrugated pipes should not bee overloaded with optical fibers. An open corrugated
pipe with the diameter of 32 mm should ca
arry no more than 60 optical fibers with the diameter
of 2 mm.
It is recommended that the corrugated pip
pe inside the cabinet should be about 10 cm long
long.
Arrange the corrugated pipe outside the cabinet
c according to the conditions of the equipment
room.
Internal pipe
External pipe
24
244
17.2 Connecting the Optical Fiber Inside the Cabinet
Caution
Bind all wires and cables used in onsite in
nstallation. Each cable type should be bound
separately. For example, power cables, alarm cables and optical fibers should be laid out
independently and bound separately. Note e that optical fibers should be bound with dedicated
fiber binding straps.
Exercise care if you must bend fibers. If bends are necessary, the fiber bending radius should
never be less than 20 d (d: fiber diameter)).
4 The optical interfaces not connected with fiberr pigtails should be covered with anti-dust caps. The
fiber pigtails not connected
with optical interfaces should be covered with pigtail caps.
Caution
Do not leave the label between two cards, wh
hich may affect the electrical conductivity between
cards.
5
25
18 Connecting the Serial Port Line
Note
The serial port line is used to connect the CONSOLE / ESC interface of the HSUC / HSUB
card and the serial port of the local computeer. It is used only in commissioning or debugging.
Insert the RJ-45 connector of the serial port liine into the CONSOLE / ESC interface of the
1
HSUC / HSUB card.
Tip
26
6
19 Installing the Cabinet Door
Note
The AN5516-04 can be installed in the followwing cabinets. Please refer to the following
manuals for the procedures of installing the cabinet
c doors.
Caution
Exercise care in operation especially when cllosing or opening the doors to avoid damage to
the cables.
20.1 Checking the Connection and Layout off Wires and Cables
Caution
When the connection and layout of the cabless and wires are completed, installers should
conduct the connectivity test and ensure that the signals are transmitted normally.
27
277
20.2 Checking before Power-on
Caution
The AN5516-04 uses -48 V DC power supplyy with an acceptable voltage range from -40 V
to -57 V.
Before powering on the equipment, installers should
1. Confirm that the cabinet power cables are correctly connected with the external power
supply equipment.
2 Confirm that all the wires and cables are co
2. onnected correctly
correctly.
3. Place all power switches on the PDP in the
e OFF position.
4. Disconnect all cards inside the subrack but leave them on their slots.
5. Disconnect the fan unit inside the subrack but leave it on its slot.
Note
The power-off procedures for the AN5516-04 are reverse to those of power-on.
28
28
28
21 Dos and Don’ts
29
299
FiberHome Telecommunication
Technologies Co., Ltd.
Address: No. 67, Guanggu Changye Jie,
Wuhan, Hubei, China
Zipcode: 430073
Tel: +6 03 7960 0860/0884 (for Malaysia)
+91 98 9985 5448 (for South Asia)
+593 4 501 4529 (for South America)
Fax: +86 27 8717 8521
Website: http://www.fiberhomegroup.com
Copyright©FiberHome Telecommunication Technologies Co., Ltd.