Experiment 6: DIFFUSION OF SODIUM CHLORIDE IN WATER

OBJECTIVE

1. Study the diffusion coefficients.

2. Determination mass transfer rate without convective effects.

Recommendation
Experiment 1 : EFFECT OF FLOW RATE IN THE EFFECTIVENESS OF SHELL & TUBE HEAT EXCHANGER

Methodology

Experiment A: Effect of Hot Water Stream

Perform the general start-up Set the hot tank temperature at 500C. After the
procedure (Refer to Work temperature is constant at 500C, switch on
Instruction on equipment). Set the pumps (P1 and P2) and air cooler. Release the air
valves arrangements asper trap in shell side by opening valve HV14 .
instructed in Table

Adjust valves HV5 to obtain the


desired flow rate for hot water and Allow the system to reach steady state
the same time fix the flowratefor cold and record all related data
water stream using valve HV15 (please
set one value of flowrate) .

Repeat steps 3 to 5 for next 4


different hot water flowrate (Hot
Water Flowrate Range: 2 – 20 LPM).

7. Shut down the equipment


Experiment B: Effect of Cold Water Stream

Perform the general start-up procedure Set the hot tank temperature at 500C. After
(Refer to Work Instruction on the temperature is constant at 500C, switch
equipment). ). Set the valves on pumps (P1 and P2) and air cooler.
arrangements as per instructed in Table 1 Release the air trap in shell side by opening
valve HV14 if necessary.

Adjust valves HV15 to obtain the desired


flow rate for cold water and the same time Allow the system to reach steady state and
fix HV5 forHot water (please set one value Record all related data.
of flowrate).

Repeat steps 3 to 5 for next 4different cold


flow rate.(Cold Water Flow rate Range: 2 – 20
LPM) and Shut down the equipment