100% found this document useful (1 vote)
449 views1 page

Ut Test Report

1) 25 armature shafts were ultrasonically tested according to specification AA0850118 category 2 to check for defects in all accessible areas. 2) The test was performed using pulse echo method with an Epoch 600 instrument, N2LS probe, and hydraulic oil couplant. 3) All 25 shafts passed ultrasonic testing and were deemed acceptable for use based on the observations and final results.

Uploaded by

Manish Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
449 views1 page

Ut Test Report

1) 25 armature shafts were ultrasonically tested according to specification AA0850118 category 2 to check for defects in all accessible areas. 2) The test was performed using pulse echo method with an Epoch 600 instrument, N2LS probe, and hydraulic oil couplant. 3) All 25 shafts passed ultrasonic testing and were deemed acceptable for use based on the observations and final results.

Uploaded by

Manish Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

BHARAT HEAVY ELECTRICALS LIMITED,BHOPAL

NON DESTRUCTIVE TESTING DIVISION


Ultrasonic Testing

(TEST REPORT)

PART1 : TEST REQUISITION


RefNo QTM/19-20 Request Date 19-AUG-19 Requester SHRI TILAK RAM YADAV
From Qc QTM Auto No 5967 Test Spec AA0850118 cat 2
Component Armature shaft TA4502 AZ Qty 25 Test Material forge shaft

Drg No 24304592076 Drg Rev No 03 Witness


Item No/TestArea all accessible area
WO No/PO No 57217A74202 Proj DETC ELECTRICS AND ENGINE
Component Id SL NO.75 TO 99 HN 1730764
Surface Condition
Thickness

PART2 : TEST REPORT


Report No : NDT19080424 Test Date : 26-AUG-19

EXAMINATION DETAILS :

Method Pulse Echo Method Test Procedure AA0850118 Cat. 2


Probe Description N2LS
Probe Scanning Manual
Equipment Epoch 600
Couplant Hydraulic Oil

Calibration & IIW - V1 Block


Sensitivity

OBSERVATION
Above mentioned 25 No.s Armature shaft ultrasonic tested as per specification and get satisfactory result.

Note:- No identification was present on Jobs so Mettalic Seal was not be transfered.

Final Result/ ACCEPTED


Remark :

Tested By : BHUPENDRA S CHAUDHARY Approved by : BHUPENDRA S CHAUDHARY Witnessed by :

ASNT Level II (UT) ASNT Level II (UT)


BHEL Bhopal BHEL Bhopal

Note : This is an electronically generated record and does not require any signature