You are on page 1of 8
‘A PRODUCT FROM HYDROMATIK GMBH RE 91470/05.90 Hydromatik MANNESMANN Fixed Displacement Pump, A7FO RE with variable setting 91470/05.90 Series 6, for open circuits, axial tapered piston —bent axis design Brueninghaus Hydraulik| Sizes 29...160 Nominal pressure 250 bar Peak pressure 400 bar | __Replaces 04.85, High pressure range ATFO Archivbild - dert alét entoommen werden Fixed capacity pump for special applications, with axial tapered piston rotary group of bent axis design for opera- tion in open circuits Flow is proportional to input speed and displacement The displacement of this pump may be steplessly set down to the value of the next smaller pump size, allowing tlow to be exactly matched to requirements. — high speeds — no drain line required — port for flushing of bearings, e.g. at high ambient temperatures = flange and shalt fully interchangeable with fixed dispalcement pump A2FO, series 6 Hydromatik BrueninghausHydraulik 1 RE 01470/05.90 Fixed displacement pump with variable setting A7FO Ordering Code avr Jo] | /[6jo| |-| | [B|11 Flui Mineral il (no short code)” * When ordering units for HF-flulds please note codo “E the type codification, ‘Axial piston unit Fixed displacement, bent axis decign (variable setting) [ are | Nominal pressure 350 bar, peak pressure 400 bar [A ‘Mode of operation Pump in open circuit Size eat diaplacamant V, (em) 0.9.2 V, = 100 om= oa factory set; infinitely variable in increments of 1 cm? | Setting range-displacement —([_29...55 | 56...80 V, (om) e . Series Index oe Direction of rotation Viewed on shaft end clockwise cA] anticlockwise ee Seals 29...55 _56...80 _81...107 108. Perbunan 1 shaft seal Viton 1 shaft seal [ Peibunan 2 shaft seal Viton 2 shalt seal elelele elelele eolele eleljele a < Shatt end Splined DIN 5480 Keyed DIN 6885 . . . ° Mounting flange 150 hole e;elfe oe Tay | Service ports Port A (B): SAE ai rear [Pon S: SAE at rear * ° ° ‘e aa @ = available 2 Hydromatik BrueninghausHydrautk RE 9147005.90 Fixed displacement pump with variable setting A7FO Technical data Fluid For extensive information on the selection of fluids and for application conditions, please consult our data sheets RE 90220 {mineral oi), RE $0221 (environmentally acceptable hydraulic fluids) or RE 90223 (ire resistance fluids, HF) You might hava to consider reduced operating data with HF: fluids or environmentally acceptable hydraulic fluids. Please contact our technical dopartment. Operating viscosity range In order to obtain optimum efficiency and service fe, wo ro- ‘commend thatthe operating viscosity (at operating temperature) be selected from within the range: Veg, = Operating Viscosity 16.36 mis referred to the tank temperature for open circu). Viscosity limits The limiting values for viscosity are as follows: Vion = 10 mms short term at a maximum permissible drain temperature of 90 Vg 1000 minis Selection diagram mt eae aD TOD 000 364 2» pi le 16 st Le oe -TTemperatre1(°) =25°C Fld temperaturerange@ Aggy = + 90°C Notes on the selection of the Hydraulle Fluid In order to select the correct fluid, itis necessary to know the ‘operating temperature in the circuit in relation to the ambient temperature ~ in an open circuit and the tank terparature. ‘Tho hydraulic fluid should be solocted so that within the opera: ting temperature range, the operating viscosity lies within the optimum range (v,,.) (See shaded section of the selection diagram). We recommend that the highest possible viscosity range should be chosen in each case, Example: At an ambient temperature of X*C, the operating temperature is 60°C. Within the operating viscosity range (v, shaded area), this correspondsto viscosily ranges VG 460r VG 68. VG 68 should be selected Important: The leckage oll (case drain oil) temperature is influenced by pressura and pump spaod and is always highor thaa the ciccut temperature. Homaver, at no point in the circuit may tha tamparatura exceed 90°C itis not possible to comply withthe cbove conditions because of extreme operating parameters or high ambient emperatures, Wo recommend tisluing the baarings via port U. Flushing flows z i si 56...80 _81...107 108...160 Q,iUmin 4 8 8 12 Temperature of flushing fluid < tank temperature Filtration of fluid The better the filtration, the longer the service life of the axial piston unit In order fo ensure correct functioning of the unit, a minimum level of cleanliness is required to: NAS 1638, class 9 Class 6 to SAE,ASTM or AIA 18/15 to ISO/DIS 4406, It this degree of cleanliness cannct be maintainod, please consult us. Cas0 Drain “Tha laakago oll chambers connactedto the suction chambor. A Grain ine to tank is not regred (por Ri plugged). Case Drain Pressure ‘The lower the speed and case drain pressure, he longer the seal lite, The values given in the diagram are limiting values for Perounan seals and should not be exceeded. It the limiting values are @xcaedod, tho sea! ite will be reduced, Shalt seal "Perbunan" ‘ zs & i a4 : 107 da 18..160 g Ro © 1000 2000 3000 4000 S000 000 speedo (pm) —Pm Shaft seal “Viton” ‘Compared with pumps equipped with Perbunan seals, in pumps equipped with Viton seals the case drain pressure can be raised by 50% at tho same drive spaed, or the speed raised by 50% at the same case pressure, Under cartain operating conditions, it may be necessary to reduce these valves. Note Maximum permissible pump speeds are given in the table on page 5 Max. permissibie casing pressure Pas na 6 bar. ‘Thepressureinthe housing mustbethe same as or gresterthan the external pressure on the shaft seal Hydromatik a) BrueninghausHydraulik RE 91470/05.90 Fixed displacement pump with variable setting ATO Technical Data Operating pressure outlet Maximum prossure at ports A or 8 Drive shaft Nom. press, Peak press. Pr ss without radial loading 350bar 400 bar (couping) with radial Toading ~~ BiSbar* 400 bar (pinion, v-bet) (Prossure data to DIN 24312) * withthe smallest possible pinion or v-belt puley diameter. With pulsating loads ovar 316 bar, we recommend the use of a splined shaft (standard A) Operating pressure inlet Minimum pressure at port $ (Suction inlet) ag yg 0,8 bar ‘The max. prassure P.,, ., (8 dependent on the shalt seal uso and the spi Installation position Optional. The pump housing mustbe filed with fluid prior to com- mmissioning, and must remain full whenever tis operating For extensive information oninstallation position, please consult ‘our data sheet RE 90 270 before completing your design work. Direction of low ‘lockvise roition —An-clockwise tation Si0B StoA Input drive Permissible axial and radial loads on drive shaft The values givan are maximum values and do not apply to continous operation (al smallest PCD of pinion Dp na) = Preload required bar op. pressure (radial force) to transmit torque at v-belt drive (DIN 7753) (a smallest pulley diameter Dy.) . S a Bt... 107 408...160 75 100 1125 mm SS«S 200 SSC mm OS 2S N88 “73580 —~=~=~«* 8062 Nibar Bae 340 co N 500 ‘900 1120 a Near 78 113 15,1 qi Code explanation Dana = Smallest PCD of pinion +Fana = Max, permissible axial force when stationary 0 When axial piston unt is running at zero press Dena Smallest pulley diameter F om (02r = permissible axial forco/bar operating pressure cement evn shan shone 7 ‘The direction of the max. permissible axial force must be noted: Fifoar = Radial force/bar operating pressure ale Emm 7 increases bering ite at pinion (DIN 867) am" (avoid i possible) oS 4 Hydromatik Brueninghaus Hydraulic RE 91470105.90 Fixed displacement pump with variable setting A7FO Technical Data Size (2 sot disoaicomont) 29.55 56..80 61...107 108...160 Displacement max. setting 4880 107 ‘160 iin, seting 2 55 a 108 Max. speed) at Veen "2500 224020001750 at V, t bar or <1 bar, the max. permissile speeds shou be read from diagram Determination of displacement Venom, Ouputiow a= (Umin) —_V, = Displacement (cm*) per revolution Ap = Differential pressure (bar) ; ye 892M ae n= Speed (rom) orque 00h (Nm), Volumati aticioney ‘ga = Mochanical-hydraulc efficiency 2esMen Mein Q*AP gy "= Overall ficiency 7, = 7," Thy) 0000” 9549 ~ 600+, Power Diagrams for determination of max. speed and required inlet pressure in relation to set dispalcement Size 29...55 5eo0 TN 3400 ~ Ss 3200 SINKS 3000 2800 2600 2400 T 2200 hi LI It 2000- . 29 30 35 40 45 50 55 Speed n (pa) ——— Size (2 V, em!) > Hydromatik 5 BrueninghausHydraulik RE 91470108.90 Fixed displacement pump with variable setting A7FO Size 56...80 3350 2.3 3200 3000 2800 8 Speed n (pn) —— to 2400 2200 2000 | HAL 1800 56.60 65 70 75 80 Sive(2 V, en?) —————> Size 61...107 so TR 23 te 2.0 2800 se RYE os i r 18, 2600 4+————~ RUA !? £2400 . ath 1s = “NY nN Ms % 2200 - 2000 nth 1800 > L | 1600 + 8185 90 95 100 107 Sie (2 V, on"), ————t» Size 108...160 2600 23 2,0 2400 1° 7 2200 8, g 1 = 2000} »? & i 1800 +— 4 108 120 130 MO 150 160 Size (© V, om’) — Inet prossue py (b!) Inet prascure p, (ba) Int pressure, a) 6 Hydromatik Brueninghaus Hydraulic RE 91470105.90 Tle rlsng or dng lose aan aaa ding Fixed displacement pump with variable setting ATFO. Prorbrn Unit dimensions 29...55 et Z Spined shat RE Waocraortdugg [81 Lao DINS489 N Detail ¥ (clockwise rotation) Detail ¥ (anti-clockwise rotation) M12; 20 doe ee M10; 17 deep Ke Ba biNeses AB Service ports SAE 3/4 420 bar (6000 ps!) High pressure range Suction port SAE2 210 bar (3000 psi) Standard range R Bleed port Miaxi,5 (plugged) U_ Bearing flushing pot M1&x115 (plugged) Unit dimensions 56...80 Z Spined shat Ea? WSracoeos Fe DIN 5480 5 v My 2% si Feats "tal Ly cs Detail ¥ (clockwise rotation) Detail Y (anti-clockwise rotation) LT) Keyed sha AS 1008186 coweaes Mn, AB Sewice ports SAE 1 420 bar (6000 psi) High pressure range S’ Suction port SAE 21/2 170 bar(2500 psi) Standard range R Bleed port Migx1,5 (plugged) U___ Bearing flushing pon M18x1/5 (plugged) Hydromatik 7 BrusninghausHydraulk RE 9147005.90 Fixed displacement pump with variable setting A7FO Toke fag you in se aint acon Snt Stacia Unit dimensions 81...107 Z Soinedshat Wabra0x1899 OWNseo ——m Z Splined shat W a5c2e80x21909 DIN 5480 0 Keyed shat AS 140170 DN sa5s | aes AB Service ports SAE 1 420 bar (6000 psi) High pressure range "Suction port SAE 21/2 170bar (2500 psi) Standard range R Bleed port Mi8x1,5 (plugged) U__Bearing flushing pot Mi8x1,5 _ (plugged) Unit dimensions 108...160 38. AB Service ports SAE 11/4 420 bar (6000 psi) High pressure range S' Suction port SAES 140 bar (2000 psi) Standard range FR Blaed pon Misxi5 (plugged) U___ Bearing flushing pot M18x1,5 (plugged) Hydromatik GmbH, Glockeraustrate 2, D-7918 Elehingen 2, B (07908) 820, Tolox 712 838, Telotax (07308) 7274, 7273 8 Hydromatik BrueninghausHydraulk

You might also like