Professional Documents
Culture Documents
PROTECTION
RELIABLE
CONNECTION
SOLUTIONS
Legrand Seico, an ISO certified and With three manufacturing facilities in Saudi
approved vendor in the whole GCC, has Arabia to cope with the high demand on
proven to be the ideal choice in providing Earthing and Lighting. Legrand Seico is
effective, efficient and reliable solutions in setting the pace in product innovation,
Earthing and Lighting. quality control and timely delivery.
Since 1990 Legrand Seico has been We value our pride in the trust and
providing technical, logistical and sales satisfaction earned from our esteemed
support with over 50 distributors covering customers which positioned us as a leader
the GCC. as we persist on providing the utmost level
of quality products and services to the
Legrand Seico examines every step in the market.
manufacturing process and applies strict
procedures to ensure the highest possible
quality in every product. An R&D team has
been put in place to offer installers and
engineers innovative products that combine
reliability, safety and value.
WHY IS LIGHTNING PROTECTION SEICO EARTHING AND LIGHTNING
IMPORTANT? PROTECTION SYSTEM
Lightning is a natural flow of static The SEICO Earthing and Lightning System
electricity between the sky and the ground. provide a dependable structure to protect
It strikes buildings, structures, trees, resources from such hazards. We offer
livestock and persons in all parts of the a products made from highly conductive
world. Although it rarely occurs in some materials and with high resistance
areas, it is a severely destructive hazard to corrosion to achieve a sustainable
whose destructive force is beyond human “connection” to earth.
scale.
The damage from lightning comes from
electrocution, human burns, burning
buildings, explosions, melted or damaged
electrical equipment and stresses on
electrical equipment that are responsible
for failures.
An effective earthing system is a
fundamental requirement of any modern
structure or system for operational and/
or safety reasons. Without such a system,
the safety of a structure, the equipment
contained within it and its occupants is
compromised.
In order to preserve resources and human
lives a reliable lightning protection system
must be set in place and must be taken into
account during the planning stage of any
project.
A reliable lightning protection system
intercepts lightning strikes and attempts
to guide the static electic flow down a
chosen path, slightly away from the people,
structures and electrical equipment. It
provides means to carry electric currents
into the earth under normal and fault
conditions without exceeding any operating
and equipment limits or adversely affecting
continuity of service and assure that a
person in the vicinity of grounded facilities
is not exposed to the danger of critical
electric shock.
We provide the entirety of the devices d) Exothermic Welding System
needed in installing an effective • Creates a permanent bond that
and reliable Earthing and Lightning is capable of withstanding repeated
Protection System on or in the fault currents and abnormal heating
structure to be protected. Enabling due to a high fault current.
clients to install an economical
system that will intercept and Whether you need a full Earthing
discharge static electric flow into the and Lightning Protection System
earthing system. for a major construction project
or you need your annual system
Our system is composed of: maintenance replacement, your job
will be handled with the same care
a) Interception Devices (Air and attention we give to all our work.
Termination System)
• A system designed to capture
lightning strikes to a specified and
selected attachment point.
b) Down Conductors
• Electrically conductive connection
between the interception device
and the earth system directing
the discharge current safely to
ground with minimal risk from
“sideflashing”.
c) Earth System
• An essential part of the lightning
protection system, the low
impedance ground dissipates the
energy into the ground. Minimizing
the ground voltage potential rise
therefore lessening the risk of injury
to the occupants and damage to
equipment.
2
Table of Contents
3
4
Length Material
Plating Color
Circular Conductor
Conductor Conductor
Diameter Size
Flat Conductor
Conductor Conductor
Width Thickness
5
LIGHTNING
PROTECTION SYSTEM
Tape Conductor Connection
AIR TERMINAL
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
6
Lightning Protection System
Tape Conductor Connection
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
7
Lightning Protection System
Tape Conductor Connection
DC TAPE CLIP
TAPE CLIP
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
8
Lightning Protection System
Tape Conductor Connection
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
9
Lightning Protection System
Tape Conductor Connection
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
10
Lightning Protection System
Tape Conductor Connection
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
11
Lightning Protection System
Tape Conductor Connection
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
12
Lightning Protection System
Solid Circular Conductor Connection
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
13
Lightning Protection System
Solid Circular Conductor Connection
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
14
Lightning Protection System
Solid Circular Conductor Connection
RE-BAR CLAMP
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
15
Lightning Protection System
Wire Conductor Connection
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
16
Lightning Protection System
Wire Conductor Connection
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
17
Lightning Protection System
Wire Conductor Connection
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
18
EARTHING
PROTECTION SYSTEM
Earth Rods
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
19
Earthing Protection System
Earth Rods
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
20
Earthing Protection System
Earth Rods
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
21
Earthing Protection System
Earth Plates
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
22
Earthing Protection System
Earth Rod Clamps
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
23
Earthing Protection System
Earth Rod Clamps
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
24
Earthing Protection System
Bonds and Clamps
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
25
Earthing Protection System
Bonds and Clamps
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
26
Earthing Protection System
Earth Points
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
27
Earthing Protection System
Bonds and Clamps
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
28
Earthing Protection System
Earth Points
DISCONNECTING LINK
ACCESSORIES
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
29
Earthing Protection System
Additional Requirements
COMPRESSION LUGS
FLAT
FLATPLATE
PLATEBAR
BAR
See STANDARD DIMENSION for reference code. Shown are standard sizes, other sizes are available upon request.
30
EXOTHERMIC
SEICOWELD SYSTEM
MOULD SPECIFICATION
Mould Cover
Starting Powder
Weld Powder
Steel Disc
Tap Hole
Graphite Mould
Weld Cavity
Cables
Weld Cavity
The majority of SEICOWELD connections have at least twice the cross sectional area of the conductors
being joined, and an equivalent or greater current carrying capacity. Because the connection is a fu-
sion of high conductivity (high copper contect alloy) it will withstand repeated fault currents, and will not
losen in the way that mechanical connectors can. Due to the alloys very high copper content
(in excess of 90%) is corrosion resistance too.
31
Exothermic Weld System
GOOD REPLACE
The SEICOWELD connection mould is designed to last for an average of 100 connections. This will very
according to the care given to the mould during use. To determine if a mould should be replaced,
regularly inspect the following checkpoints.
CABLE OPENING
•The Cable should be fit for the hole. A loose fit will cause leakage of weld powder.
•The opening should not be crack or worn out.
WELD CAVITY
•The cavity should be well defined.
•There should be no chips or gouges.
TAP HOLE
•The tap hole should be well defined.
DISK SEAT
•The seat should not be worn or cracked.
• The disk must seat properly.
32
Exothermic Weld System
WELD CONNECTION
SEICOWELD exothermic welding can be used in various applications to have certainly goods
connections in work.
Many projects trust in SEICOWELD such as:
•Lightning and Surge Protection
•Grounding in Electrical Works
•Railway Construction
•Cathodic Construction
•Another High Capacity of Current Supply
SEICOWELD offers different types of mould. There are “One Time Mould” and “Graphite Mould” with
different shapes to suit different welding works.
“ONE TIME MOULD” is made of ceramic suitable for “One off” welding work.
“GRAPHITE MOULD” is made of high quality graphite suitable for high quality welding work and can be
used for several times and which has the following advantages:
• A smooth metal connection that will not loosen or corrode.
• It is not affected by high current surge or over current.
• No need for external welding machine.
• Use only lightweight and cheap equipment.
• Virtually maintenance free.
33
Exothermic Weld System
34
Exothermic Weld System
SEICOWELD ACCESSORIES
This is made of graphite block, a This is used for opening and clos- For welding cables on steel pipes,
heat resistance material which ing the mould. The handle clamp the handle clamp SHC-1 is
normally welds an average of (HC) are of two types depending on especially designed to fit solid
70 to 100 connections under the mould size moulds.
normal size. (HC-M & HC-L).
For safety and quick For easy cleaing of the For cleaning safely the For removing easily the
ignition of the starting conductor before welding. inner part of the mould. stages which accumu-
powder. Standard flint (CCB) (MB) lated the crucible. (MS)
replacement are suitable.
(IL)
35
Exothermic Weld System
WELDING INSTRUCTION
Step1: When using insulated cables, Step2: Preheat the welding mould with Step3: Connect the handle clamp to
remove first 150mm of the isolation a welding torch or ignite a box of weld the hole and separate the two arms to
of the conductor and all the dust and powder in order to remove the mois- open the mould, then fit the conduc-
oxydes is to cleaned properly by mould ture before starting the first weld. tors and leave 5-6mm gap on the other
brush, and/or cardcloth brush. conductor.
Step4: Close the mould with the Step5: Pour the weld powder, which Step6: On the bottom of the powder
handle clamp and put the STEEL DISC is on the upper portion of the powder canister, you can see the ignition pow-
on the taphole, the conical side of the box, into the crucible. der, put it on the lip of the crucible and
disc should be at the bottom. on the top of the weld powder for easy
ignition.
Step7: Ignite the flint ignitor from Step8: After one minute, separate the Step9: Clean completely the mould
aside the ignition powder. Pull away two arms of the handle clamp to open by using mould scraper and by mould
the flint ignitor once it ignited to avoid completely the mould in order for the brush,m you can continue welding as
damage. welded parts tube to be removed. Extra long as the mould is still warm.
care should be taken so as not to dam-
age the mould.
36
Exothermic Weld System
INFORMATION
EXOTHERMIC WELDING MOULDS are designed and manufactured to fit different type and size of Cop-
per Conductors, Earth Rods and Concrete Steel Rebars. Above are the following conductor selection,
any other type or size not mentioned can be provided, just give us your details.
HOW TO ORDER:
Choose the appropriate required connection from our SEICOWELD Connection Chart. Check your run
cable size. The cell wherein the two selection meet, shows the powder size needed to carry out the
connections.
Example: If you require CABLE to CABLE (Straight Horizontal) with 35mm2 and 150mm2 Conductor,
You have to order as follows:
37
Exothermic Weld System
Cable to Cable Connection
38
Exothermic Weld System
Cable to Cable Connection
39
Exothermic Weld System
Cable to Rod / Rod to Rod Connection
40
Exothermic Weld System
Cable to Rod / Rod to Rod Connection
41
Exothermic Weld System
Cable to Concrete Steel Re-Bar Connection
42
Exothermic Weld System
Cable to Concrete Steel Re-Bar Connection
43
Exothermic Weld System
Cable to Steel Surface and Cable to Steel Pipe Connection
ONE SIDE SINGLE (CH-PVH) SINGLE ASCENDING (CH-VS) SINGLE PIPE HORIZONTAL
(CT-TH)
44
Exothermic Weld System
Cable to Steel Surface and Cable to Steel Pipe Connection
45
Exothermic Weld System
Cable to Busbar Connection
STRAIGHT INCLINED
(CH-TF)
SINGLE DESCENDING
(CH-VI)
SINGLE HORIZONTAL
(CH-TH)
46
Exothermic Weld System
Cable to Busbar Connection
47
Exothermic Weld System
Busbar to Busb ar Connection
48
Exothermic Weld System
Busbar to Busb ar Connection
49
INDEX
50
> NOTES
51
> NOTES
52
> NOTES