Electrical Characteristics
SRP-330-BPA SRP-335-BPA SRP-340-BPA SRP-345-BPA
Module Type SRP-330-BPA-HV SRP-335-BPA-HV SRP-340-BPA-HV SRP-345-BPA-HV
1996±1
Open Circuit Voltage (Voc) 46.0 46.2 46.5 46.7
SERIAL NUMBER
40±1
STC: lrradiance 1000 W/m² module temperature 25°C AM=1.5; Grounding holes
2×Ø
1716±1
1216±1
10±1
1996±1
SERIALNUMBER
BOX
BOX
BOX
+
-
1100
1100
Junction Box
negative ( - ) positive ( + )
Temperature Characteristics A A
-0.38 %/°C
Ⅱ
-0.30 %/°C
942±1
35
-40~+85 °C
9 70 70
.5
R4
45±2 °C
70
40
14
70
I II
5:1 2:1
10
Packing Configuration 8
1996x 992x 40 mm 6
Current [A]
In the meantime, the overall space between cells are doubled, and more light will be transferred into power through multiple reflections.
Compared to mainstream standard modules, the Blade™ series module has lower current and series resistance which helps minimize
mismatch loss, internal power loss, and shadow effect, etc. Once one cell has EL defect or appearance defect, such as black edge or V
sharp. After cutting, one intact half can be reused. Standard Cell Half Cell
The ribbon length of half-cell is shorter than normal cell. Calculated by Joule's law and Ohm' law, the power loss reduction is nearly 6%.
More Output Higher Efficiency Higher ROI
Product Certificates
Less Mismatch loss Warranty
Instead of 6 internal strings of cells, the Blade series module has 2 x 6 shorter ones. This design effectively deals with the mismatch
happened between cells caused by shadow, out of sync performance degradation, ect. 100%
97.5% 97.5% Add
tion
10 Guarantee
al V
94.7% alue
from on product
Guaranteed Power
Line
Standard Module
91.2% ar W
arra material and workmanship
With 6 internal strings of cells 90%
87.7%
nty YEARS
84.2%
80.7%
25 linear power
9A 9A 9A 9A 9A 9A Insurance 80%
0 5 10 15 20 25
YEARS output warranty
9A 9A 9A 9A 9A 9A Years
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
Higher Yield Due to Better Shading Response
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A Blade™ comprises two separated and identical solar cell arrays, which means the ordinary strings of cells are cut into halves, and
9A 9A 9A 9A 9A 9A these shorter strings compose arrays which has separated current paths. When a module is shaded, only one side shaded array's
9A 9A 9A 9A 9A 9A
current will be impacted, while the other array will still be functionally producing power. Under this circumstance, when a module is
9A 9A 9A 9A 9A 9A
shaded, the affected working areas of Blade™ will be 50% less.
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 8.7A
By cutting solar cell into halves, the internal power loss will be lower and hot spot effect will also be reduced.
Design Sketch Circuit Diagram Electrical Mismatch