SRP-XXX-BPA: Maximum System Voltage1000 VDC


-HV SRP-XXX-BPA-HV: Maximum System Voltage1500 VDC

Electrical Characteristics
SRP-330-BPA SRP-335-BPA SRP-340-BPA SRP-345-BPA
Module Type SRP-330-BPA-HV SRP-335-BPA-HV SRP-340-BPA-HV SRP-345-BPA-HV

STC STC STC STC

Maximum Power at STC (Pmp) 330 335 340 345

1996±1
Open Circuit Voltage (Voc) 46.0 46.2 46.5 46.7
SERIAL NUMBER

Short Circuit Current (Isc) 9.11 9.19 9.24 9.32

Maximum Power Voltage (Vmp) 38.3 38.5 38.8 39.0

Maximum Power Current (Imp) 8.62 8.71 8.77 8.85

Module Efficiency at STC(ηm) 16.67 16.92 17.17 17.42 992±1

40±1

Power Tolerance (0,+4.99)


Mounting holes
SERIAL NUMBER

Maximum System Voltage 1000 VDC / 1500 VDC SERIALNUMBER I


Label

Maximum Series Fuse Rating 20A

STC: lrradiance 1000 W/m² module temperature 25°C AM=1.5; Grounding holes
2×Ø

1716±1
1216±1
10±1

1996±1
SERIALNUMBER
BOX

BOX
BOX

+
-

1100
1100
Junction Box
negative ( - ) positive ( + )

Temperature Characteristics A A

-0.38 %/°C

-0.30 %/°C
942±1

+0.05 %/°C 992±1

35
-40~+85 °C
9 70 70

.5
R4
45±2 °C

70

40
14

70
I II
5:1 2:1

Mechanical Specifications Section A-A


10:1

I-V Curve (SRP-340-BPA(-HV))


External Dimensions 1996x 992x 40 mm
Weight 22.5 kg 12
Cells temp. = 25 °C
Solar Cells Poly crystalline 10 Incident Irrad. = 1000 W/m²

Front Glass 3.2 mm AR coating tempered glass, low iron


8 Incident Irrad. = 800 W/m²
TM
Frame Anodized aluminium alloy
Current [A]

6 Incident Irrad. = 600 W/m²

Junction Box IP67


4 Incident Irrad. = 400 W/m²
Output Cables 4.0 mm²,cable length: 1100 mm
Incident Irrad. = 200 W/m²
Connector 2

Cuts Night, Breaks Dawn.


MC4 Compatible
Mechanical Load 0
5400 Pa 0 10 20
Voltage [V]
30 40 50

10

Packing Configuration 8

1996x 992x 40 mm 6
Current [A]

Container 20’GP 40’GP

Pieces per Pallet 27 27 4 Incident Irrad. = 1000 W/m²


Cells temp. = 10 °C
Cells temp. = 25 °C
Pallets per Container 10 22 Cells temp. = 40 °C
2 Cells temp. = 55 °C
Cells temp. = 70 °C
Pieces per Container 270 594
0
0 10 20 30 40 50 60
Voltage [V]

Add: No.1-2, HengyaoRd, HenglinTown, Wujin District, 213000, Changzhou, China


Tel: +86-519-69699879 Fax: +86-519-88786181 Email: info@seraphim-energy.com
info@seraphim-energy.com
www.seraphim-energy.com
330W-345W
TM TM

Cuts Night, Breaks Dawn. Cuts Night, Breaks Dawn.

Less Internal Power Loss


Blade™ – A Module re-Modeled
Seraphim’s Blade™ Series solar module boasts two identical parts, which are composed of cells that are half the size of ordinary solar
Cut
cells. By cutting cells into halves, these smaller currents will help reduce “Cell To Module” loss, which means higher output.

In the meantime, the overall space between cells are doubled, and more light will be transferred into power through multiple reflections.
Compared to mainstream standard modules, the Blade™ series module has lower current and series resistance which helps minimize
mismatch loss, internal power loss, and shadow effect, etc. Once one cell has EL defect or appearance defect, such as black edge or V
sharp. After cutting, one intact half can be reused. Standard Cell Half Cell

The ribbon length of half-cell is shorter than normal cell. Calculated by Joule's law and Ohm' law, the power loss reduction is nearly 6%.
More Output Higher Efficiency Higher ROI

Product Certificates
Less Mismatch loss Warranty
Instead of 6 internal strings of cells, the Blade series module has 2 x 6 shorter ones. This design effectively deals with the mismatch
happened between cells caused by shadow, out of sync performance degradation, ect. 100%
97.5% 97.5% Add
tion

10 Guarantee
al V
94.7% alue
from on product

Guaranteed Power
Line

Standard Module
91.2% ar W
arra material and workmanship
With 6 internal strings of cells 90%
87.7%
nty YEARS

84.2%

80.7%
25 linear power
9A 9A 9A 9A 9A 9A Insurance 80%

0 5 10 15 20 25
YEARS output warranty
9A 9A 9A 9A 9A 9A Years

9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A
Higher Yield Due to Better Shading Response
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 9A Blade™ comprises two separated and identical solar cell arrays, which means the ordinary strings of cells are cut into halves, and
9A 9A 9A 9A 9A 9A these shorter strings compose arrays which has separated current paths. When a module is shaded, only one side shaded array's
9A 9A 9A 9A 9A 9A
current will be impacted, while the other array will still be functionally producing power. Under this circumstance, when a module is
9A 9A 9A 9A 9A 9A
shaded, the affected working areas of Blade™ will be 50% less.
9A 9A 9A 9A 9A 9A
9A 9A 9A 9A 9A 8.7A
By cutting solar cell into halves, the internal power loss will be lower and hot spot effect will also be reduced.
Design Sketch Circuit Diagram Electrical Mismatch

Standard Module Blade Module


TM

Module current output is 8.7A, current mismatch in series is 0.3A.

Blade™ With 2 x 6 internal strings of cells


4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

4.5A 4.5A 4.5A 4.5A 4.5A 4.35A

Design Sketch Circuit Diagram Electrical Mismatch

Module current output is 4.5+4.35=8.75A, current mismatch in series is 0.15A.

SRP-DS-EN-2019V1.0 | © Copyright 2019 Seraphim