You are on page 1of 3

ORDER FORM No.

(DATA SHEET) SHEET 1 OF 3


SPECIFICATION FOR TANK DESIGN IN ACCORDANCE WITH SAFETY
INSTRUCTIONS FOR VERTICAL CYLINDRICAL STEEL TANKS FOR x - TICK AS NECESSARY
OIL AND OIL PRODUCTS

CUSTOMER

CUSTOMER'S ADDRESS

SITE

SITE ADDRESS

Normative and technical documentation for design

Normative and technical documentation for fabrication

TANK NOMINAL CAPACITY CUB. М

TANK TYPE: WITH FIXED ROOF WITHOUT PONTOON


WITH FIXED ROOF WITH PONTOON
WITH FLOATING ROOF

SHELL INTERNAL DIAMETER MM ; SHELL HEIGHT ММ

RESPONSIBILITY CLASS : CLASS 1 CLASS 2 CLASS 3

TANK SERVICE LIFE YEARS

OPERATION DATA
1. STORED PRODUCT
2. STORED PRODUCT DENSITY Т / CUB. М
3. MAXIMUM PRODUCT FILLING LEVEL ММ
4. MAXIMUM PRODUCT STORAGE TEMPERATURE О
С
5. INTERNAL EXCESSIVE PRESSURE IN THE TANK kPа
6. RELATIVE VACUUM IN THE TANK kPа
7. PRODUCT FILLING/DISCHARGE RATE CUB. М / HOUR

8. STORED PRODUCT CIRCULATION CYCLES PER YEAR


9. TEMPERATURE OF COLDEST DAY AND NIGHT with prov. 0.98 acc. to SNiP 23-01-99 О
С

10. SNOW LOAD kPа


11. WIND LOAD kPa
12. SITE SEISMIC ZONE POINTS
13. SHELL HEAT INSULATION: YES, ММ NO
14. ROOF HEAT INSULATION: YES, ММ NO

DESIGN AND PROCESS DATA


1. SHELL : ROLLED PLATE BY PLATE
CORROSION ALLOWANCE : YES, ММ NO
2. BOTTOM : ROLLED PLATE BY PLATE
SLOPE : OUTSIDE INSIDE NO
CORROSION ALLOWANCE : YES, ММ NO
3. FIXED ROOF : CONE UMBRELLA
CONE FRAME UMBRELLA FRAME
CONE PANEL UMBRELLA PANEL
CORROSION ALLOWANCE : YES, ММ NO
4. FLOATING ROOF : SINGLE DECK DOUBLE DECK
CORROSION ALLOWANCE : YES, ММ NO
5. STAIRWAY : CIRCULAR ( SPIRAL) STREIGHT
6. PONTOON : ROLLED PANEL ON FLOATS (ALUMINIUM)

REPRESENTATIVE OF THE CUSTOMER OR COMPANY AUTHORIZED BY THE CUSTOMER :

TITLE, NAME, SIGNATURE, DATE


ORDER FORM No. (DATA SHEET) SHEET 2 OF 3

MANHOLES AND NOZZLES


(MAY BE GIVEN AS SPECIFICATION - SEE APPENDIX E sheet 3)

1. SHELL MANHOLES : DN 600 IN THE FIRST SHELL COURSE PCS.

DN 800 IN THE FIRST SHELL COURSE PCS.

600 x 900 IN THE FIRST SHELL COURSE PCS.

DN 600 IN THE THIRD SHELL COURSE PCS.

2. INLET / OUTLET NOZZLES :

NOM. PIPE SIZE (ММ) NOM. PRESSURE. (МPа) TYPE ''S'' TYPE ''D'' TYPE ''F''

100 1.6 PCS. PCS. PCS.


150 1.6 PCS. PCS. PCS.
200 1.6 PCS. PCS. PCS.
250 1.6 PCS. PCS. PCS.
400 1.6 PCS. PCS. PCS.
600 1.6 PCS. PCS. PCS.
700 1.6 PCS. PCS. PCS.
3. CLEANOUT NOZZLES : DN 100 PCS. DN 150 PCS. DN 200 PCS.

4. ROOF MANHOLES : DN 500 PCS. DN 600 PCS. DN 1000 PCS.


5. ROOF NOZZLES :

NOM. PIPE SIZE (ММ) NOM. PRESSURE. (МPа) SITE VENT


100 0.25 PCS. PCS.

150 0.25 PCS. PCS.


200 0.25 PCS. PCS.

250 0.25 PCS. PCS.


350 0.25 PCS. PCS.
500 0.25 PCS. PCS.

TANK APPURTENANCES
1. LIGHTNING RODS : YES, HEIGHT ММ PCS. NO
2. EARTHING FIXTURES : YES, PCS. NO

3. STRUCTURES FOR FOAM GENERATORS : YES, TYPE , PCS. NO


4. SPRINKLING PIPELINE BRACKETS : YES, NO

5. LAVEL GAGE BRACKET УДУ-10 : YES, NO


6. CLEANOUT SUMP : YES, FOR PIPE WITH DIAMETER ММ NO
7. BOTTOM CLEANOUT DOOR : 600 x 600 900 x 1200 NO

SPECIFIC CONDITIONS AND ADDITIONAL REQUIREMENTS

REPRESENTATIVE OF THE CUSTOMER OR COMPANY AUTHORIZED BY THE CUSTOMER :

TITLE, NAME, SIGNATURE, DATE


ORDER FORM No. (DATA SHEET) SHEET 3 OF 3

MANHOLE AND NOZZLE LOCATION SCHEMES


SHELL 0º

SHELL SHELL

aо NOZZLE NOZZLE
В C В C
TYPE ''S'' TYPE ''D''
270º 90º

А BOTTOM А BOTTOM

ROOF
180º

SHELL А А
В
Manhole or В В
nozzle
TYPE ''F''
С С
BOTTOM SHELL ROOF SHELL FLOAT. ROOF
А
КРЫША

MANHOLES AND NOZZLES SPECIFICATION


SEC. NOMINAL NOM. NOZZLE LOCATION
PURPOSE PIPE SIZE PRESS, TYPE А В С NOTES
No.
ММ МPа (''S'',''D'',''F'')
aО ММ ММ ММ
1 2 3 4 5 6 7 8 9 10
SHELL MANHOLES AND NOZZLES
1
2
3
4
5
6
7
8
9
10
ROOF MANHOLES AND NOZZLES
1
2
3
4
5
6
7
8
9
10
NOTES:
1. NOZZLES ARE TAKEN WITH FLANGES TO GOST 12820-80, DESIGN 1 TO 12815-80, FOR
NOMINAL PRESSURE PY = 1.6 МPа FOR SHELL NOZZLES AND PY = 0.25 МPа FOR ROOF NOZZLES,
UNLESS OTHERWISE STATED IN COLUMNS 4 AND 10 OF THE SPECIFICATION.
2. MANHOLE AND NOZZLE LOCATION IN THE PLAN (CORNER a º) AND THEIR ELEVATION (SIZE А) MAY BE CHANGED
BY THE DESIGNER MINIMALLY TO FULLFILL THE REQUIREMENTS
REGARDING DISTANCE BETWEEN THE ATTACHMENT WELDS AND SHELL WELDS.
3. IF THE LOCATION DATA ARE NOT AVAILABLE IN THE SPECIFICATION (COLUMNS 6…9), COLUMN 6 (CORNER a º)
WILL NOT BE FILLED BY THE DESIGNER, AND COLUMNS 7…9 (SIZES А, В, С) WILL BE FILLED
IN ACCORDANCE WITH MINIMUM DESIGN REQUIREMENTS.

REPRESENTATIVE OF THE CUSTOMER OR COMPANY AUTHORIZED BY THE CUSTOMER :

TITLE, NAME, SIGNATURE, DATE