Professional Documents
Culture Documents
Cemont Citig 1500 DC Rev.00 PDF
Cemont Citig 1500 DC Rev.00 PDF
Service Manual
CITIG 1500 DC
R1
FIG. 1
1.3 CHECK OF THE MAIN COMPONENTS • Diodes of the secondary circuit: check
WITH TESTER (OHMMETER) points A-B of diode 1 and points C-D of
1. Electronic circuit ref. 3: check the presence of diode 2 (fig. 5): if at least one shows short
short circuits on the rectifier bridge and the circuits the board is broken.
1102 Pag. 3
CITIG 1500 DC
FIG. 5 FIG. 9
• Prefeeding resistances R1 and R2: verify • Disconnect the feeder; set the oscillo-
for each resistance the value 3K3 with the scope with a range of 1V/DIV and connect
levelling condensers discharged; if there the probe X100 between points XT2-
are other readings the resistances are bro- 3(GND) and XT2-1(probe) (fig. 10), con-
ken. nect the machine to the power supply,
switch it on:
FIG. 10
1
5
A
FIG. 6
FIG. 8
1102 Pag. 5
CITIG 1500 DCCITIG 1500 DC
ding, the electronic circuit ref. 1 is correctly • if the voltages are not regular replace the
fed but it does not work. electronic circuit ref. 48; if the fault is still
P there replace the electronic circuit fig. 20
M
2. Short-circuit points G - F of the remote outlet
ref. 51 and check for:
• the presence of a high frequency hum for
approx. 2 seconds; if there is no hum, there
is no command from the board ref. 32
• the presence of 24Vdc on the solenoid
valve ref. 46; if this is not present, replace
the electronic circuit ref. 20; if the fault is still
FIG. 12
there replace the electronic circuit ref. 32
3. In case of malfunction of the tig functions
1.5 CHECK OF GENERATOR WORKING IN TIG (slope down spot, pre-and post gas) replace
the electronic circuit ref. 48
1. Set the generator to tig mode, switch it on and
verify: Carry out the final test after the repair.
• on the electronic circuit ref. 20 check the
voltage on the following points:
2.0 FINAL TEST
• between XF3 and X F2 a voltage of 230
Vac (fig. 13) 1. Carry out the safety test according to our ope-
rative instruction N. SLL12, before procee-
ding, act as follows:
3
2 RHEOPHORE
THE PRIMARY
1 CIRCUIT
FIG. 15
FIG. 14
• switch on
• on the connector X4 between points 2
(GND) and 3 (POS.) (fig. 14) measure a • short-circuit the feeder plug
voltage of approx. - 1,2Vdc • short-circuit the output dinse.
1102 Pag. 7
CITIG 1500 DC
• After the test remove all the short circuits 8. Disconnect the probe, switch off the genera-
and restore the connections. tor and with the load to the maximum current,
let the machine work at the greatest capacity
2. Connect the generator to the power supply till the thermostatic protection intervenes (the
(230 Vac), set it in MMA and check if the vol- thermostatic protection led turns on).
tage of the outputs is 55 Vdc (+/- 5%): switch
off the generator. 9. Wait until the machine starts working again
(the thermostatic protection led turns off) and
3. Connect the generator to the resistive load: disconnect the machine from the resistive
the load must be regulated so that the voltage load.
o n th e l o a d , w it h ma x i mu m c u r r e n t , is
between 20V and 25V. Apply oscilloscope 10.Carry out MMA welding tests at the maximum
probe as in fig. 8 current (one electrode).
4. Set the regulation knob to the centre of the 11. Carry out welding tests in tig either in 2 stro-
dial, switch on the generator, turn the knob to kes or in 4 strokes and check the following
the maximum welding current and read with functions:
the amperometer the maximum current indi- • SLOPE DOWN
cated on the technical table with +/- 5% tole-
rance. See on the oscilloscope a waveform as • SPOT
in fig. 16 • PRE-GAS
• POST-GAS
FIG. 16
T
FIG. 17
1102 Pag. 9
SPARE PARTS LIST - PIÈCES DÉTACHÉES - LISTA DE LAS PIEZAS DE RECAMBIO - ERSATZTEILLISTE
EÇAS SOBRESSELENTES - RESERVDELAR - WISSELSTUKKEN - LISTA PIESE COMPONENTE
LISTA CZĘŚCI ZAMIENNYCH - ∫∞∆∞§√°√™ ∞¡∆∞§§∞∫∆π∫ø¡ - ПЕРЕЧЕНЬ ЗАПАСНЫХ ЧАСТЕЙ
38 42
13.1
13
11
56
12 51
52
57
36
48
10
15
20
01
25
03
32
14 46
33 09
08
I
SPARE PARTS LIST - PIÈCES DÉTACHÉES - LISTA DE LAS PIEZAS DE RECAMBIO - ERSATZTEILLISTE
EÇAS SOBRESSELENTES - RESERVDELAR - WISSELSTUKKEN - LISTA PIESE COMPONENTE
LISTA CZĘŚCI ZAMIENNYCH - ∫∞∆∞§√°√™ ∞¡∆∞§§∞∫∆π∫ø¡ - ПЕРЕЧЕНЬ ЗАПАСНЫХ ЧАСТЕЙ
II
SPARE PARTS LIST - PIÈCES DÉTACHÉES - LISTA DE LAS PIEZAS DE RECAMBIO - ERSATZTEILLISTE
EÇAS SOBRESSELENTES - RESERVDELAR - WISSELSTUKKEN - LISTA PIESE COMPONENTE
LISTA CZĘŚCI ZAMIENNYCH - ∫∞∆∞§√°√™ ∞¡∆∞§§∞∫∆π∫ø¡ - ПЕРЕЧЕНЬ ЗАПАСНЫХ ЧАСТЕЙ
III
DUTY CYCLE - FACTEUR DE MARCHE - CICLO DE TRABALHO - BEDRIJFSCYCLUS - CICLO DE TRABAJO
INTERMITTENSFAKTOR - BEDRIJFSCYCLUS - CICLUCL DE LUCRU
∫À∫§√™ ∂ƒ°∞™π∞™ - РАБОЧИЙ ЦИКЛSE
SCHWEISSSTROMBEREICH - CORRENTE DE SOLDADURA - SVETSSTRÖM - SNIJSTROOM
CORENT DE TAIERE - PRĄD SPAWANIA - ƒ∂Àª∞ ™À°∫√§§∏™∏™ - Сила тока
WELDING CURRENT - COURANT DE SOUDAGE - CORRIENTE DE SOLDADURA
DUTY CYCLE - FACTEUR DE MARCHE - CICLO DE TRABAJO - EINSCHALTDAUER - CICLO DE TRABALHO - INTERMITTENSFAKTOR
BEDRIJFSCYCLUS - CICLUCL DE LUCRU - ∫À∫§√™ ∂ƒ°∞™π∞™ - РАБОЧИЙ ЦИКЛ
I OUT
IV
WIRING DIAGRAM - SCHÉMA ÉLECTRIQUE - ESQUEMA ELÉCTRICO - STROMLAUFPLAN
ESQUEMAS ELÈCTRICOS - ELSCHEMOR - ELEKTRISCHE SCHEMA'S - SCHEMA ELECTRICA
SCHEMAT ELEKTRYCZNY - ∏§∂∫∆ƒπ∫√ ¢π∞°ƒ∞ªª∞ - ЭЛЕКТРИЧЕСКАЯ СХЕМА
V
CIRCUIT BOARD HF 344/TH CE 22519 (W000050170)
ELECTRONIC CIRCUIT BOARD HF 344/TH CE 22519 (W000050170) page 1of2
ELECTRONIC CIRCUIT BOARD HF 344/TH CE 22519 (W000050170) page 2of2
CIRCUIT BOARD HF 344/TH CE 22538 (W000232541)
ELECTRONIC CIRCUIT BOARD HF 344/TH CE 22538 (W000232541)
CIRCUIT BOARD TV 316 CE 22438 (W000050187)
ELECTRONIC CIRCUIT BOARD TV 316 CE 22438 (W000050187)
CIRCUIT BOARD HF 317 CE 22437 (W000070040)
ELECTRONIC CIRCUIT BOARD HF 317 CE 22437 (W000070040)
CIRCUIT BOARD CE 22692
ELECTRONIC CIRCUIT BOARD CE 22692