Professional Documents
Culture Documents
■Dimensions(mm)
Terminal type
18 M6
18
※Contents indicated (including the recycle
Battery case resin: Flame-retardant (UL94V-0)
marking,etc) are subject to change without notice.
■Characteristics 0℃
60
20 hour rate 75Ah
Capacity 10 hour rate 70Ah
30
(25 ℃) 3 hour rate 53Ah
1 hour rate 50Ah -15℃
(minute)
Internal Resistance 10
Fully charged battery 7 mΩ
(25 ℃)
Temperature 40 ℃ 102% 5
Dependency of 25 ℃ 100% 3
Capacity 0℃ 85%
(20 hour rate) -15 ℃ 65%
After 3 months 91% 1
Self Discharge 1 3 10 30 100 300 1000
After 6 months 82%
(25 ℃) Discharge current(A)
After 12 months 64%
1/2
■Charging Method (25℃) ■Cut off voltage
3.75A- 15.0A- 37.5A- 75.0A- 150A-
Discharge current
Control voltage:13.6-13.8V 15.0A 37.5A 75.0A 150A 225A
Trickle use
Initial current:11.3A or smaller
Cut off voltage(V) 10.5 10.2 9.9 9.3 8.7
10 2.275V/Cell 80
5℃
60 (41℉)
0.1 0
0 10 20 30 40 50 60 0 2 4 6 8 10 12 14 16 18 20
Temperature (℃) Storage Period (Month)
■Constant-voltage constant-current charge characteristics for Trickle use ■Discharge capacity by temperature and by discharge current
160 16.0 120
B attery Voltage
140 14.0
0.3 0.05CA
100 0.10CA
120 12.0
Charge Quantity(%)
Battery Voltage(V)
80 0.25CA
100 10.0
Capacity(%)
0.50CA
0.2 ① Discharge
80 —
— 100% (0.05CA*20H) 8.0
— 60 1.00CA
— 50% (0.05CA*10H)
2.00CA
60 ② Charge 6.0
40 3.00CA
0.1 Charge Voltage: 13.7V(2.28V/Cell)
40 Charge Current: 0.15CA 4.0
③ Temperature: 25℃ (77℉ ) 20
20 2.0
C harge Cu rren t
0 0 0.0 0
0 4 8 12 16 20 24 -15 0 15 30 45
Char ge Tim e (H) Battery temperature(℃)
■Discharge characteristics(25℃)
20.0
15.0
Terminal voltage(V)
10.0
18.75A 3.75A
225A 75.0A
5.0
0.0
0 1 2 3 5 7 10 20 40 60 2 4 6 8 10 20 40
(minute) (hour)
Duration of discharge
! Caution
Due to the potential energy stored in the batteries, Please read《Precautions for handling the Rechargeable Valve Regulated Lead Acid Batteries》
before using batteries. If improper handling or use of the batteries without understanding《Precautions for handling the Rechargeable Valve
Regulated Lead Acid Batteries》may result in bodily injury caused by electrolyte leakage, heat generation, or explosion.
2011.12
2/2