9" 9"

1'-0" 1'-0"
9"
8 -16 Ø 4 -20 Ø
4-16 Ø 4 -20 Ø 4 -16 Ø
+4 -16 Ø
+4 -16 Ø +4 -12 Ø
1'-6"

1'-6"
9"

8Ø@ 4''c/c / 8''c/c 8Ø@ 4''c/c / 8''c/c 8Ø@ 4''c/c / 8''c/c 8 Ø @ 4'' c|c / 8'' c|c 8 Ø @ 4'' c|c / 8'' c|c
C1 C2,C4,C5 C3,C6 C7 C8,C9
FOOTING SCHEDULE
COL. NO. Footing Size CONC. DEPTH FOOTING REINFORCEMENT
LXB
C1 4'-0''X 4'-0'' 21'' D
12 Ø @ 6'' c/c BOTHWAYS
C2,C4,C5 6'-0''X 6'-0'' 24'' 12Ø @ 6'' c/c BOTHWAYS
C3,C6 7'-6''X 7'-6'' 30'' 12Ø @ 5'' c/c BOTHWAYS
C7 6'-6''X 4'-6'' 27'' 12Ø @ 5'' c/c BOTHWAYS
C8,C9 4'-0''X 4'-0'' 21'' 12 Ø @ 6'' c/c BOTHWAYS
N.G.L
6" 6"
FOOTING REINFORCEMENT

Concrete Depth

3'-6"
1'-6"
1'-6"
9"

4" 4"
6"

6"
FOOTING SIZE
P.C.C
NOTES:- REVISION PROJECT TITLE DRAWING TITLE :- ARCHITECTS
1. USE M-20 CONC. i.e. 1:112:3 PROJECT FOR COLUMNS DETAIL LIVING SPACE
Revision No.00 ARCHITECTURE INTERIORS
2.USE TMT STEEL GRADE Fe 415. H. No. -12,13,14
3.MIN. CONC. TO STEEL REINFORCEMENT IN : AT LUDHIANA HJ-749, BRS NAGAR,LUDHIANA.
Revised On.00-00-00 SCALE DATE DRG. NO: DRAWN
COLUMN= 40 MM Ph. +91-161-5058968 ,5088968
FOOTING= 60 MM info@livingspacearch.com
1'-0" = 34" 20-09-13 CN/GF/FLP/01/a SHIVANGI www.livingspacearch.com