NEW Ethernet System Catalogue

NEW
EtherNet/IP™ Compatible
Communication Unit
KV-EP02

Conquer the Ethernet


Debut of an EtherNet/IP™ compatible communication unit
PLCs

Connect to
over 100 types of
new and old PLCs
from all over the world
Just select the model to
communicate with in order to KEYENCE sensors
enable data links between PLCs
regardless of their manufacturers.

Program-less
communication with
over 200 types of
KEYENCE sensors Devices made by
other manufacturers
Obtain the information from a
variety of sensors in order to
expand the scope of applications Ladder-less
to include those such as
traceability, predictive communication with
maintenance, and tooling everything ranging
changes.
from measurement
systems to robots

Connect all the devices It is possible to communicate


with devices made by other
manufacturers without having to

within a production site use any bothersome


communication programs such

over Ethernet.
as for command definition and
for processing during command
transmission/reception.

2
NEW
EtherNet/IP™ Compatible
Communication Unit
KV-EP02

Remote I/O systems

Plug & Play


Easily connect everything over
Ethernet—from devices with no
communication functions to
sensors.

3
Master

CPU Unit with Built-In Ethernet Unit


EtherNet/IP™ Port KV-XLE02
KV-7500
Remote I/O system

EtherNet/IP™
Communication speed: 2 ports Maximum number of
Compatible Hardware w EtherNet/IP™
100 Mbps (built-in switching hub function) connectable units: 15*
Communication Unit
* When the scanner is the KV-7000/5000/3000 Series (The maximum number of units is 7 for analogue units.)
KV-EP02 NEW

I/O Unit (European Terminal Block)

16-point Input Unit 8-point Output Unit 16-point Output Unit


DC input Relay output Transistor (sink) output
KV-NC16EXE NEW KV-NC8ER KV-NC16ETE NEW

Transistor (source) output


KV-NC16ETPE NEW

I/O Unit (Screw Terminal Block)

8-point Input Unit 16-point Input Unit


DC input DC input
KV-N8EX KV-N16EX

8-point Output Unit 16-point Output Unit 8-point/8-point I/O Unit


Relay output Relay output DC input
KV-N8ER KV-N16ER Relay output
KV-N8EXR
Transistor (sink) output Transistor (sink) output
KV-N8ET KV-N16ET DC input
Transistor (sink) output
Transistor (source) output Transistor (source) output KV-N8EXT
KV-N8ETP KV-N16ETP

4
32-point Type Base Unit
KV-NC32T
EtherNet/IP™ Unit
KV-NC1EP

I/O Unit (MIL Connector) Connection Conversion Unit

16-point Input Unit 32-point Input Unit 16-point Output Unit European Terminal
DC input DC input Transistor (sink) output Block/MIL Connector Š
KV-NC16EX KV-NC32EX KV-NC16ET Screw Terminal Block
KV-NC1
Transistor (source) output
KV-NC16ETP Screw Terminal Block
Š European Terminal
Block/MIL Connector
KV-N1

ŠFor connection
examples, see the
32-point Output Unit 16-point/16-point 32-point/32-point system configuration
Transistor (sink) output I/O Unit I/O Unit diagrams on page 18.
KV-NC32ET DC input DC input
Transistor (sink) output Transistor (sink) output
Transistor (source) output
KV-NC16EXT KV-NC32EXT
KV-NC32ETP

Analogue I/O Unit/Temperature Input Unit (European Terminal Block/Screw Terminal Block)

4-point Analogue 2-point Analogue 2-point/1-point 4-point Temperature


Input Unit Output Unit Analogue I/O Unit Input Unit
KV-NC4AD KV-NC2DA KV-N3AM KV-NC4TP

5
REMOTE I/O
SYSTEM
Single-Touch Setup

Decimal
rotary switches

2 EtherNet/IP™ ports All points


common terminal

Easy configuration of both hardware and software

Use rotary switches to set the IP address


The IP address can be set with the communication
unit’s built-in rotary switches. Because the setting
can be configured with the hardware as well as
with the software, anyone can configure the setting
easily.

Open the lid Simply use the rotary


switches to set the
IP address

Configure the device settings


with a single click
After wiring and powering the devices, just click
the Auto Configuration button to finish configuring
the settings. The settings can be configured as a
batch, which leads to major reductions in the
required work hours even in large-scale facilities.

6
Flexible support for device layouts

Space saving
The thinnest case in the industry minimises the
installation space requirements. Furthermore, the
European terminal block types require no external
terminal block, which further reduces the
installation space requirements.

48.9
mm

Supports line-type and star-type wiring


Both line-type and star-type wiring are possible,
allowing for highly flexible wiring. Furthermore,
Line type
empty ports can be used in place of switching
hubs, which reduces costs.

Star type

Thorough optimisation of everything


from settings to monitoring
No device comment registration required
Device comments are automatically registered No device registration
when the device settings are configured. RT (Real is required. Just search
with comments.
Time) Edit makes it possible to perform
programming without worrying about device
numbers, which reduces the amount of work hours
that are required.

Model names can be


used to narrow-down
the results.

Multiple dedicated monitors available


Dedicated monitors for remote I/O and for the Monitor screen
sensors are available. KEYENCE’s VT5 touch panel on a PC
can be used to monitor the devices from a list
without having to perform drafting,* which is useful
when identifying the cause of an error that has
occurred.
* This is not supported by the VT5-W07M and by Soft-VT.

Monitor screen on the VT5

7
ETHERNET
NETWORK
High-speed and Large-capacity
Communication via EtherNet/IP™

Remote I/O

High-speed, large-capacity network

High-speed communication with Various sensors,


solenoid valves, etc.
a maximum speed of 0.5 ms
EtherNet/IP™ realises high-speed communication
with a speed of 0.5 ms. This can be used between
expansion units in order to perform operations
such as the high-speed acquisition of sensor data
and measured values for high-speed response Number of data updates per second * When transmitting 128 bytes of data
applications.
Serial 45×
180 times 2000 times
EtherNet/IP™

Large-capacity communication to support


large-scale systems Communication image

Communication bandwidth for communication over general-purpose Ethernet


A communication bandwidth of 30000 pps is
dedicated for EtherNet/IP™, which makes it Communication bandwidth dedicated for EtherNet/IP™
possible to construct large-scale systems that use
a large amount of remote I/O and sensor devices.
* When using the KV-XLE02 256 units maximum*

EtherNet/IP™

* With an RPI of 17.5 ms or more

8
Highly flexible systems

Can be combined with general-purpose


Ethernet
EtherNet/IP™ can be used together with general-
purpose Ethernet communication such as PLC link
and FTP. This makes it possible to construct
everything from sensor control to data EtherNet/IP™ Ethernet devices
communication with the host system over the same compatible devices
network.

These can be used together on the same network

Independent communication cycles


for each device 0.5 ms: Target pass detection
Fibreoptic sensor
The communication cycle can be set on each
communication device to match the application.
Communication can be performed with a maximum
1.0 ms: Cylinder operation
speed of 0.5 ms, so these unique communication
Remote I/O
cycles are effective in supporting high-speed
responses and in reducing the load on the network.
20.0 ms: Instantaneous
The optimal flow rate measurement
communication cycle
can be set for each Flow sensor
device

Functions that improve usability

Visualising the network load factor


The state of the network load can be checked on a
dedicated screen. Just by changing the
communication cycle, the network load is
automatically calculated. This makes it possible to
verify the optimal communication cycle setting in
advance.

Automatic calculation of the load rate Communication cycle


of the unit or adapter setting for each device

QoS function that maintains


the punctuality NE-Q05(P)
Touch panel
display
Using the KEYENCE NE-Q05 switching hub causes
QoS (packet priority control) to operate without the
Ethernet
need for users to configure any settings.
This allows EtherNet/IPTM control data to be EtherNet/IP™
Packets are
maintained in real time. transmitted
with Sensor
priority.

Even when other Ethernet communication loads are large,


EtherNet/IP™ communication is given priority, which maintains
the communication punctuality.

9
KEYENCE
SENSOR
Connecting between KEYENCE Devices
for an Expanded Scope of Applications

Sensor linking to connect to the selected device

Immediately connect to
over 200 types of sensors
Program-less communication with KEYENCE
sensors is possible simply by selecting and placing
General-purpose
the sensors. There are over 200 types of sensor Code reader
compatible sensors, which makes it possible to
flexibly support a wide variety of applications.

Measurement
Vision system system

Sensor monitor that requires no drafting


The KEYENCE Touch Panel Display VT5 is
provided with setting/monitor screens as standard.* Change the setting
These screens are created automatically, which value from the VT5.

eliminates the hassle of drafting the screens and


reduces the amount of work required.
* This is not supported by the VT5-W07M and by Soft-VT.

Display the sensor error


messages.

10
Drastically reduces sensor adjustment work

Sensors can be adjusted even from


a remote location
Even when a sensor amplifier is installed in a
hard-to-reach location such as a clean room or
within a deep control panel, the sensor amplifier
can easily be checked and adjusted from a touch
panel.

Tool changes with a single touch


Changing the settings
Conventionally, tool changes required that the on multiple sensors
settings be changed on each sensor. However, this KV-7500
can now be performed using only operations from
a touch panel, reducing the amount of sensor
Setting
adjustment work that is required. change Measured data

GT2 Series
+ DL-EP1
VT5 Series

Using the sensor network to expand


the scope of applications
Sensor predictive maintenance
The PLC’s ability to acquire the current value of a
sensor in addition to the OK/NG signals makes it
possible to detect how dirty the sensor is and how
much the sensor deteriorates over time—things
that could not be detected until now. This makes it
possible to construct a system for predictive Received
light intensity
maintenance.

Displays the
Threshold fluctuations
FS-N Series change in received VT5 Series
KV-7500
+ NU-EP1 light intensity.

High-speed data communication through COS + direct output


COS transmission and reception
The COS (Change Of State) function, which COS + unit interrupt
performs data communication as an interrupt, KV-X COM XG-X/CV-X
supports transmission and reception. This leads to
Image capture trigger input Image capture data
improvements in processing time during control acquisition
■ Transfer time comparison
with frequent communication such as alignment
using a vision system. COS reception only 8.68 ms
COS
transmission and 1.40 ms Approximately 6 times faster
reception
* When 100 bytes are transmitted and received using the XG-X2000 and a 10 ms RPI
(using unit interrupts)

11
PLC AND
FIELD DEVICE
Integrate Data from New and Old Machines
without Ladder Programs

Connectible to various PLCs from all over the world

Program-less communication with over


100 types of new and old PLCs PLC Link PLCs
Function from
Communication can be established with PLCs from ■ Ethernet various
each vendor without the need for programming. ■ Serial vendors
A wide range of industrial Ethernet networks, which
vary from one manufacturer to the next, are also
supported. This makes it possible to collect data Industrial
from and visualise new and old devices. Ethernet
PLCs
■ EtherNet/IP™ from
■ EtherCAT ® various
■ CC-Link IE Field vendors
■ PROFINET

Establish PLC links just by selecting the


PLC and setting the device
Just select the PLC that will be used for
communication and set the device to finish
configuring the settings. Large-capacity data links
up to 720k words can be established between up
to 64 units comprised of up to 16 different models
with absolutely no need for ladder programs.

(1)Set the PLC to transmit from (2)Set the PLC to transmit to


• Pattern (writing/reading/transmitting) • Equipment • Device
• Equipment • Device • Number of words • Timing (event/cyclic)

* EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.

12
Connect to communication devices
without ladder programs
PROTOCOL STUDIO provides support to
create communication protocols
Conventionally, the creation of communication
commands required a ladder program. However,
communication commands can now be set easily
and interactively. Such ladder-less communication
leads to reduced work hours.

Loaded with over 100 types of preset Devices that support presets with Ethernet
communication
commands Category Vendor name/protocol name
Image processing system
A rich variety of communication commands such 2D code/barcode reader
as general-purpose protocols (Modbus/TCP) and Laser marker/inkjet printer KEYENCE
Displacement sensor/
commands ranging from those for temperature measurement system
Recorder
controllers to those for robots have been loaded as RKC Instrument
presets. Communication can be established Temperature adjuster Yokogawa
Azbil
smoothly without having to check the device’s Inverter Mitsubishi
manual. YASKAWA
EPSON
Industrial robot
YAMAHA
DENSO
Modbus/TCP
General-purpose protocol
SLMP

Š For details on devices that support presets, see page 17.

Minimising the time from programming


to establishing communication
Making complicated communication
programs simple with flows Handshaking is easy because
the user can establish
conditional branches just by
The user can perform programming easily just by arranging blocks.
arranging blocks according to an operation flow.
Also, the progress of a program can be monitored
visually because the active (running) block is
highlighted.

The running block is


highlighted, so the progress
of the program can be
understood easily at a glance.

The communication test and the


communication monitor improve the
debugging efficiency
These two debugging functions minimise the trial
and error that are required until communication is
established due to issues such as the entry of
incorrect ASCII codes or incorrectly typed [Communication monitor function]
This function makes it possible to monitor the
transmission/reception. This dramatically reduces transmission and reception statuses while a
the time required until communication is [Communication test function] program is running without requiring a protocol
analyser.
established. This function makes it possible to transmit
communication commands in a ladder-less
manner and to check the connection and
received data.

13
ROBOT
Ensuring Availability of Robots That are
Indispensable for Manufacturing

Simplifying complicated communication with robots

NEW

Loaded with preset commands for


industrial robots
Typical commands for communicating with robot
controllers are loaded as presets. Communication
is possible without having to purchase additional
options that support open networks, which leads to
reduced costs.

Supports everything from SCARA robots


Positioning
to multi-joint robots instruction
SCARA/
It is possible to communicate with everything from multi-joint robot
SCARA robots used to convey targets to multi-joint Positioning
KV-7000 Series Robot
robots used in assembly work and conveyance + KV-XLE02
complete
controller
between processes, which makes it possible to
SCARA Multi-joint
support a wide range of applications. Vendor name Robot controller model
robot robot
YASKAWA YRC1000, DX200, FS100 — ✓
EPSON RC700-A, RC90 (RC + 7.0) ✓ ✓
YAMAHA RCX340 ✓ —
DENSO* RC8A, RC8 ✓ ✓
* Because this is RAC communication, an update time of 300 ms or more is required when
reading or writing data.

14
Setting configuration in just 3 steps

STEP 1 Command/response settings

The preset commands are displayed automatically.

Device assignments can be selected from data memories (DMs)


and buffer memories (UGs).

STEP 2 Command addition/creation

Preset commands can be selected from the pull-down list.


Commands can also be added to this list.

It is also possible to create new commands that have not been


preset. Up to 320 communication commands can be created.

STEP 3 Automatic program generation

[Flow]
Flow blocks with pre-registered settings are generated
automatically (PROTOCOL STUDIO).

[Ladder program] Drag and drop Drag and drop


Just drag the communication commands to automatically
generate the ladder programs.
■ Enable operation ■ Execute event
■ Obtain execution result
■ Clear error ■ Obtain error details
Flow Ladder program

Using communication with robots to expand the scope of applications

Monitoring the electrical current to perform Setting and changing robot operations
predictive maintenance from a PLC
Communication can be used to It is possible to perform robot
collect various information from teaching and to change the
within a robot. For example, robot’s operations from a PLC
monitoring the electrical current without having to use
in real time makes it possible to specialised software or
understand the load status and pendants. Tooling changes can
thereby prevent problems before also be executed easily from the
they occur. PLC.

15
List of PLCs that support KV-X COM

PLC Link Function Industrial Ethernet


Ethernet Serial
Vendor name Series name CPU model CC-Link
Expansion Expansion EtherNet/IP™ EtherCAT® PROFINET
IE Field
CPU direct CPU direct
unit unit
KV-7500 ✓ ✓ — ✓ ✓ — — —
KV-7300 — ✓ ✓ ✓ ✓*1 — — —
KV-5500 ✓ ✓ — ✓ ✓ — — —
KEYENCE KV KV-5000 ✓ ✓ — ✓ ✓*1 — — —
KV-3000 — ✓ ✓ ✓ ✓*1 — — —
KV-1000/700 — ✓ ✓ ✓ — — — —
KV Nano — ✓ ✓ ✓ ✓*1 — — —
RxxCPU ✓ ✓ — — — — — ✓*3
MELSEC iQ-R
RxxENCPU ✓ ✓ — — — — — ✓
QxxJ — ✓ ✓ ✓ — — — —
Qxx(H) — ✓ ✓ ✓ — — — —
QxxUJ — ✓ ✓ ✓ — — — ✓*3
QxxU(D) — ✓ ✓ ✓ — — — ✓*3
MELSEC-Q
QxxUDH — ✓ ✓ ✓ — — — ✓*3
QxxUDE(H) ✓ ✓ — ✓ — — — ✓*3
QxxUDV ✓ ✓ — ✓ — — — ✓*3
Q02CPU-A, Q02HCPU-A, Q06HCPU-A — — ✓ ✓ — — — —
MELSEC-L LxxCPU(-BT) ✓ — — ✓ — — — ✓*3
MELSEC iQ-F FX5U, FX5UC ✓ — — — — — — —
Mitsubishi FX3U(C)/3G(C)/3S — ✓ ✓ ✓ — — — —
MELSEC-FX FX0, FX0N, FX0S, FX1N(C), FX1S, FX2N(C) — — ✓ ✓ — — — —
FX1, FX2(C) — — ✓ — — — — —
A2US(H) — ✓ ✓ ✓ — — — —
MELSEC-AnS A1S(H), A1SJ(H), A2S(H), A171S(H),
— ✓ ✓ ✓ — — — —
A1SCPUC24-R2
MELSEC-A2C A2CCPUC24(-PRF) — — — ✓ — — — —
MELSEC-A0J2 A0J2(H) — — ✓ ✓ — — — —
MELSEC-AnN A1N, A2N, A3N — — ✓ ✓ — — — —
MELSEC-AnA A2A, A3A — — ✓ ✓ — — — —
MELSEC-AnU A2U, A3U, A4U — — ✓ ✓ — — — —
Q2A — — ✓ ✓ — — — —
MELSEC-QnA
Q2A-S1, Q3A, Q4A, Q2AS(-S1), Q2ASH(-S1) — — — ✓ — — — —
NJ NJ501, NJ301, NJ101 — — — — ✓ ✓ — —
NX1P NX1P2 — — — — ✓ ✓ — —
CJ2H, CJ2M-CPU3x, CJ1M-ETN ✓ ✓ ✓ ✓ ✓ — — —
SYSMAC CJ2/CJ1 CJ2M-CPU1x, CJ1M-CPU1x,
— ✓ ✓ ✓ ✓*1 — — —
CJ1M-CPU2x, CJ1G, CJ1H
SYSMAC CS1 CS1G, CS1H — ✓ ✓ ✓ ✓* 1
— — —
CP1H, CP1L — ✓ — ✓ — — — —
SYSMAC CP1
CP1E-N — ✓ ✓ — — — — —
OMRON
SYSMAC SRM1 SRM1-C01, SRM1-C02 — — ✓ ✓ — — — —
SYSMAC CPM1(A) CPM1, CPM1A — — — ✓ — — — —
CPM2A, CPM2C,CQM1(H),
— — ✓ ✓ — — — —
C200HE, C200HG, C200HX, C200HS
SYSMAC C C20H, C40H, C80H — — ✓ — — — — —
C120(F), C200H, C500(F),
— — — ✓ — — — —
C1000H(F), C2000(H)
SYSMAC CV CVM1, CV500, CV1000, CV2000-Vx — — ✓ ✓ — — — —
MEWNET FP — — ✓ ✓ — — — —
Panasonic
FP7 ✓ ✓ ✓ ✓ ✓ — — —
Fuji MICREX-SX ✓ ✓ ✓ ✓ — — — —
HX — — — — — ✓ — —
HITACHI EHV ✓ ✓ ✓ ✓ — — — —
HIDIC-S10α — — ✓ ✓ — — — —
MP3000 ✓ ✓ — — ✓*1 — — —
YASKAWA
MP2000 ✓ ✓ ✓ ✓ ✓*1 — — —
PC2/PC3 — — ✓ ✓ — — — —
JTEKT
PC10 ✓ — ✓ — — — — —
(TOYODA)
TOYOPUC-Plus ✓ ✓ — — ✓*1 ✓*2*4 — —
Yokogawa FA-M3 ✓ ✓ ✓ ✓ — — — —
nv type1 light ✓ ✓ — — — — — —
TOSHIBA V/PROSEC T1/PROSEC T3 — ✓ ✓ — — — — —
PROSEC T2 — ✓ ✓ ✓ — — — —
TOSHIBA MACHINE TCmini α/TC200 — — — ✓ — — — —
JW300 — ✓ ✓ ✓ — — — —
SHARP JW-21/22/31/32/33/50/70/100CU — — ✓ ✓ — — — —
JW10 — — ✓ — — — — —
SLC500 — — — — ✓ — — —
Rockwell CompactLogix — — — — ✓ — — —
(Allen-Bradley) MicroLogix — — — — ✓ — — —
ControlLogix — — — — ✓ — — —
SIMATIC S7-300 — — — ✓ — — ✓ —
Siemens SIMATIC S7-1200 ✓ — — — — — ✓ —
SIMATIC S7-1500 ✓ — — — — — ✓ —
LSIS XGK/XGI ✓ ✓ — — — — — —
*1 Requires an EtherNet/IP™-compatible communication unit.
*2 Requires an EtherCAT®-compatible communication unit.
*3 Requires a CC-Link IE Field-compatible communication unit.
*4 For details on the connection method, contact your KEYENCE sales representative.

16
List of external devices that support KV-X COM

KEYENCE devices
PROTOCOL STUDIO
Category Series name Communication unit KV sensor network
Ethernet Serial
Fibreoptic sensor/ FS-N/LV-N/PS-N NU-EP1 ✓ — —
laser sensor/
photoelectric sensor LR-T/LR-W NU-EP1 (via MU-N) ✓ — —
AP-N NU-EP1 ✓ — —
FD-Q NU-EP1 (via MU-N) ✓ — —
Pressure/flow sensor FD-X NU-EP1 ✓ — —
DL-EP1 ✓ — —
FD-S/FD-MH
DL-RS1A — — ✓
DL-EP1 ✓ — —
Displacement sensor GT2/GT/IL/IG/IB
DL-RS1A — — ✓
XG-X/XG-8000/7000*1 — ✓ ✓ ✓
Image processing
CV-X/CV-5000*2 — ✓ ✓ ✓
system
CV-3000 — — ✓ ✓
Vision sensor IV-HG/IV-G/IV — ✓ — —
SR-2000/1000/750 — ✓ ✓ ✓
SR-D100 — ✓ — ✓
SR-650 — ✓ — —
N-L20 ✓ ✓ —
SR-700
N-410, N-R2/R4, BL-U1/U2, N-42, DV-90 — — ✓
SR-G100 SR-LR1 ✓ ✓ ✓
— — — ✓
HR-100 N-L20 ✓ — —
2D code/
N-R2, BL-U1/U2, N-42, DV-90 — — ✓
barcode reader/
— — — ✓
RFID
HR-50/40 N-L20 ✓ — —
N-R2, BL-U1/U2, N-42, DV-90 — — ✓
N-L20 ✓ ✓ —
BL-1300
N-410, N-R2/R4, BL-U1/U2, N-42, DV-90 — — ✓
N-L20 ✓ ✓ —
BL-700
N-410, N-R2, BL-U1/U2, N-42, DV-90 — — ✓
BL-600 N-410, BL-U1/U2, N-42, DV-90 — — ✓
RF-500 N-410, N-R2/R4, BL-U1/U2, N-42 — — ✓
MD-U1000 — ✓ — —
MD-X1000/X1500/F3200/F5200*3 — ✓ ✓ ✓
Laser marker/ MD-T1000/F3100/F5100 — — ✓ ✓
inkjet printer MD-S9900(A) — — — ✓
ML-Z9500/G9300 — — — ✓
MK-U6000 — — ✓ ✓
WI-5000 — ✓ ✓ ✓
CB-EP100 ✓ — —
LJ-V7000/LS-9000
Displacement sensor/ — — ✓ ✓
measurement system LK-G5000 — ✓ ✓ ✓
LK-G3000/LJ-G5000/LS-7600/LS-7500/
— — — ✓
TM-3000/LT-9500/SI-T1000/SI-F1000
Recorder TR-H/W — — ✓ ✓
SJ-E/H — — — ✓
Static eliminator/
DL-EP1 ✓ — —
electrostatic sensor SK
DL-RS1A — — ✓
Safety sensor SZ-V — ✓ — —
*1 Supported from Ver. 4.0; *2 Second Edition (2.2) supported; *3 Supported from main unit and PC software Marking Builder 3 Ver. 2.0 Contact your nearest office for release status.

Devices by other manufacturers


Vendor name / PROTOCOL STUDIO
Category Series name Model
protocol name Ethernet Serial
RB RB100, RB400, RB500, RB700, RB900 — ✓
FB FB100, FB400, FB900 ✓ ✓
CB CB100, CB400, CB500, CB700, CB900 — ✓
RKC Instrument FAREX SR Mini HG H-PCP-J — ✓
REX-F REX-F400, REX-F700, REX-F900 — ✓
Z-TIO, Z-DIO ✓ ✓
SRZ
Z-CT, Z-COM (Z-TIO, Z-DIO, Z-CT) — ✓
Temperature adjuster E5AC, E5CC, E5EC, E5GC, E5GN, E5CN, E5CN-H,
OMRON Thermac NEO — ✓
E5CN-U, E5AN, E5AN-H, E5EN, E5EN-H, E5DC
UT75A, UT55A, UT35A, UP55A, UP35A ✓ ✓
Yokogawa UT Advanced
UT52A, UT32A, UP32A — ✓
SDC15, SDC25, SDC26, SDC35, SDC36,
SDC — ✓
Azbil SDC45A, SDC46A, SDC45V, SDC46V
NX NX-CB2, NX-CL1/CR1, NX-TL1/TR1 ✓ ✓
DB600 DB630, DB650, DB670 — ✓
CHINO
DB DB1000, DB2000 — ✓
AD-4410, AD-4407A, AD-4406A, AD-4402, AD-4401,
Weighing indicator A&D AD — ✓
AD-4329, AD-4328
MC/GX/GF/GP MC, GX, GX-K, GF, GF-K, GP — ✓
A&D FZ/FX FZ-i, FZ-iWP, FX-i, FX-iWP — ✓
Electronic balance
AD-4212 AD-4212A, A-4212B, AD-4212C — ✓
Shimadzu UX/UW/UW-V UX, UW, UW-V — ✓
FR-A800, FR-F800 ✓ ✓
Mitsubishi FREQROL
FR-A700, FR-E700, FR-D700, FR-F700P — ✓
YASKAWA GA700/x1000 A1000, V1000, J1000, U1000, GA700 — ✓
Inverter
FRENIC-MEGA, FRENIC-Multi, FRENIC-Eco, FRENIC-Mini,
Fuji FRENIC — ✓
FRENIC-Ace, FRENIC-HVAC, FRENIC-VG
OMRON 3G3xx 3G3MX2, 3G3MX2-V1, 3G3RX-V1 — ✓
ROBO CYLINDER PCON, ACON, SCON, DCON, ERC2, ERC3 — ✓
IAI
Electric actuator X-SEL X-SEL — ✓
YAMAHA TRANSERVO TS-S2, TS-X, TS-P — ✓
AKW1110, AKW1111, AKW1121, AKW2010G,
Power meter Panasonic KW AKW2020G, AKW5112, AKW5212, AKW7111, — ✓
AKW8111, AKW8111H, AKW8115
V600 V600-CA5D01, V600-CA5D02 — ✓
RFID OMRON
V680 V680-CA-5D01-V2, V680-CA-5D02-V2 — ✓
YASKAWA YRC1000/DX200/FS100 YRC1000, DX200, FS100 ✓ —
EPSON RC700/RC90 RC700-A, RC90 (RC+7.0) ✓ —
Industrial robot
YAMAHA RCX340 RCX340 ✓ —
DENSO RC8 RC8A, RC8 ✓ —
Modbus/TCP ✓ —
General-purpose
Modbus RTU — ✓
protocol
SLMP ✓ —
17
System configuration

KV-7000 Series

256 units maximum*1


KV-7000 KV-XLE02

Line type

15 units maximum

NE-Q05 (P)

Star type

KV Nano Series

64 units maximum*2
KV-NC32T KV-NC1EP

Line type

8 units maximum
NE-Q05 (P)

Star type

*1 KV-XLE02: With an RPI of 17.5 ms or more


*2 KV-NC1EP: With an RPI of 21.5 ms or more

Connection Expansion unit


conversion unit extension cable
[Connection example] [Connection example]
The connection conversion unit This enables flexible layouts by
can be used to connect a extending the distance between
screw terminal block type units without adding any
expansion unit. communication units.

KV-NC1 Screw terminal block unit OP-87581 (1 m)

18
EtherNet/IP™ communication specifications/communication unit specifications

EtherNet/IP™ communication specifications — KV-XLE02/KV-7500/KV-NC1EP


Item KV-XLE02 KV-7500 KV-NC1EP
Supported transmission rates 1000BASE-T, 100BASE-TX, 10BASE-T 100BASE-TX, 10BASE-T
Number of connections 256*1 64*1

RPI (communication cycle) 0.5 to 10000 ms (0.5 ms unit)


Can be set by connection. (Refresh data without depending on the number of nodes)
Output to
adapter Cyclic/Change Of State*2 Cyclic*2
Transmission
trigger Input from
adapter Cyclic/Change Of State*2 Cyclic/Change Of State*2
Cyclic
communication Allowable band (504 bytes) 30000 (pps)*3 10000 (pps)*3 6000 (pps)*3
CIP for cyclic
service communication*4 (1444 bytes) 15000 (pps)*3 5000 (pps)*3 3000 (pps)*3

Maximum number of refresh words 24k words 16k words 8k words


Maximum data size for
1 connection*5 504 bytes or 1444 bytes

Multicast filtering function*6 Yes (IGMP client function)


Class 3
Server Number of connections: 256*7 Number of connections: 64*7
Message (connection type)
communication UCMM Client Number of simultaneous actions: 32
(non-connection type) Server Number of simultaneous actions: 256 Number of simultaneous actions: 96
EtherNet/IP™ conformance test Compliant with CT13 Compliant with CT11 Compliant with CT10
MDI/MDI-X automatic switching function Supported Supported —
*1 In total, the number of connections used for the message communication function in Class 3 (connection type) should be a maximum of 256 (64).
*2 Can communicate with devices that output data using the Change Of State (Send data when any change occurs) method.
*3 Abbreviation of “packet per second”, indicating the number of sent/received packets processed per second.
*4 If the communication bandwidth is more than 100 Mbps, use a 1000 Mbps compatible Ethernet switch.
*5 Data synchronism in a connection is guaranteed. If 505 bytes or more are used, the device used should support Large Forward Open (CIP option specification).
*6 Because the Ethernet unit has an IGMP client function, unnecessary multicast packets can be filtered by using an Ethernet switch supporting IGMP Snooping.
*7 In total, the number of connections used for the cyclic communication function should be a maximum of 256 (64).

General specifications — KV-EP02


Item Specifications
Supply voltage 24 VDC (+10%/-15%)
Operating ambient temperature 0 to +55°C (no freezing)*1*2
Operating ambient humidity 5 to 95%RH (no condensation)*1
Storage ambient temperature -25 to +75°C
Storage ambient humidity 5 to 95%RH (no condensation)*1
Operating environment No dust or corrosive gas
Operating altitude 2000 m or less
Pollution degree 2
Overvoltage category I

Noise immunity 1500 Vp-p or more; pulse width: 1 μs, 50 ns (based on noise simulator);
IEC standard-compliant (IEC61000-4-2/3/4/6)

Withstand voltage 1500 VAC for 1 minute between the power terminals and the I/O terminals, and between the external terminals and the housing
(1000 VAC for 1 minute between the power supply terminal and output terminals for the transistor output type expansion I/O unit)
Insulation resistance 50 MΩ or more (between the power terminals and the input terminals and between the external terminals and the housing, with 500 VDC megohmmeter)
Intermittent vibration No. of scans
Frequency Acceleration Half amplitude
5 to 9 Hz — 3.5 mm
Compliant with JIS B 3502 9 to 150 Hz 9.8 m/s2 — 10 times in each of
Vibration resistance*3
and IEC61131-2 Continuous vibration the X, Y, and Z directions
Frequency Acceleration Half amplitude (for 100 min.)
5 to 9 Hz — 1.75 mm
9 to 150 Hz 4.9 m/s2 —
3
Shock resistance* Acceleration: 150 m/s ; operation time: 11 ms; 3 times in each of the X, Y, and Z directions
2

Internal current consumption*4 120 mA or less


Weight Approx. 130 g
*1 Guaranteed range in which the system can be used.
*2 The temperature below the unit centre (30 mm) inside a control panel.
*3 When mounted on a DIN rail.
*4 The maximum current consumption including that of expansion units is 1.8 A.

Performance specifications — KV-EP02 EtherNet/IP™ communication specifications — KV-EP02


Specifications Item Specifications
Item
10BASE-T 100BASE-TX Cyclic communication
Connection interface RJ-45 8-position modular connector × 2 ports Message communication
Supported functions
Transmission rate*1 10 Mbps 100 Mbps (explicit message communication),
EtherNet/IP™ UCMM, and Class 3 support
Transmission media*2 Category 3 or higher UTP or STP Category 5 or higher UTP or STP specifications Number of connections 64
(STP is recommended) (STP is recommended)
RPI (communication cycle) 0.5 to 10000 ms (0.5 ms unit)
Maximum cable length*3 100 m 100 m Trigger Cyclic
Maximum number of connectable hubs*4 4 2 Conformance test Compliant with CT14
*1 10 Mbps/100 Mbps MDI/MDI-X automatic switching function supported * EtherNet/IP™ is either a registered trademark or a trademark of ODVA.
*2 STP = Shielded twisted pair cable; UTP = Unshielded twisted pair cable
*3 The maximum cable length refers to the distance between the KV-EP02 and the Ethernet switch.
*4 The maximum number is not limited when an Ethernet switch is used.

19
Expansion unit specifications (European terminal block/MIL connector type)

Specifications — Expansion input unit Specifications — Expansion output unit


KV-NC16EX KV-NC16EXE KV-NC32EX Model KV-NC16EXT (16 + 16 points) KV-NC32EXT (32 + 32 Points)
Model
(16 points) (16 points) (32 points) External connection method Connector
External connection method Connector European terminal block Connector Number of inputs 16 32
24 VDC 5 VDC 24 VDC 5 VDC 24 VDC 5 VDC Input mode 24 VDC mode 5 VDC mode 24 VDC mode
Input terminals
mode mode mode mode mode mode Maximum input voltage 26.4 VDC
Maximum input voltage 26.4 VDC Rated input voltage 24 VDC/5.2 mA 5 VDC/1 mA 24 VDC/3.6 mA
24 VDC 5 VDC 24 VDC 5 VDC 24 VDC 5 VDC Minimum ON voltage 19 V 3.5 V 19 V
Rated input voltage
5.2 mA 1 mA 5.2 mA 1 mA 5.2 mA 1 mA Maximum OFF current 1.5 mA — 1.5 mA
Minimum ON voltage 19 V 3.5 V 19 V 3.5 V 19 V 3.5 V Maximum OFF voltage — 1.5 V —
Maximum OFF current 1.5 mA — 1.5 mA — 1.5 mA — Common method 16 points/1 common (1 terminal)*1 32 points/1 common (2 terminal)*1

Input
Maximum OFF voltage — 1.5 V — 1.5 V — 1.5 V
Input time OFF to ON ON to OFF
16 points/1 common 16 points/1 common 32 points/1 common constant setting Typ. Max. Typ. Max.
Common method
(2 terminals)*1 (16 terminals)*2 (2 terminals)*1
25 µs 10 µs 50 µs 50 µs 150 µs
Input time constant
Input time OFF to ON ON to OFF 300 µs 240 µs 290 µs 280 µs 390 µs
constant setting Typ. Max. Typ. Max. 1 ms 1 ms 1.2 ms 1 ms 1.2 ms
Input time constant 10 ms 10 ms 11 ms 10 ms 11 ms
25 µs 10 µs 50 µs 50 µs 150 µs
(four-level
switching) 300 µs 240 µs 290 µs 280 µs 390 µs Input impedance 4.4 kΩ 6.3 kΩ
1 ms 1 ms 1.2 ms 1 ms 1.2 ms Number of outputs 16 32
10 ms 10 ms 11 ms 10 ms 11 ms Output mode MOSFET (N-ch) (with overcurrent protection function)*2
Input impedance 4.4 kΩ Rated load 30 VDC, 0.2 A*3
Internal current consumption 20 mA or less 20 mA or less 20 mA or less Leakage current at OFF 100 μA or less

Output
Weight Approx. 100 g Approx. 120 g Approx. 110 g Residual voltage at ON 0.6 VDC or less
*1 The KV-NC16EX and KV-NC32EX have 2 COM terminals, but these are shared internally. Common method 16 points/1 common (1 terminal)*1 32 points/1 common (2 terminal)*1
*2 The KV-NC16EXE has 16 COM terminals, but these are shared internally. Operation OFF to ON 100 μs or less (with a load of 1 mA or more)
time ON to OFF 200 μs or less (with a load of 1 mA or more)
Specifications — Expansion output unit Internal current consumption 30 mA or less 60 mA or less
Weight Approx. 120 g Approx. 150 g
KV-NC8ER KV-NC16ET(P) KV-NC16ET(P)E KV-NC32ET(P)
Model *1 The input COM and output COM terminals are independent.
(8 points) (16 points) (16 points) (32 points)
*2 If even a single overcurrent is detected, the protection operation (output turned OFF) and automatic
Output mode Relay MOSFET output (With overcurrent protection function)*1*6
recovery are repeated for all outputs within the shared common, until the cause of the problem is
External connection European terminal European terminal removed.
Connector Connector
method block block *3 Rated load of each common is 1.6 A.
Rated load 250 VAC/30 VDC, 2 A 30 VDC, 0.2 A*7
Leakage current at OFF — 100 μA or less Specifications — Temperature input unit
Residual voltage at ON — 0.6 VDC or less Model KV-NC4TP
ON resistance 50 mΩ or less — Number of inputs*1 4
4 points/1 common 16 points/1 common 16 points/1 common 32 points/1 common Input Thermocouple Platinum resistance thermometer
Common method
(8 terminals)*3 (2 terminals)*2*4 (16 terminals)*2 (2 terminals)*2*5
Response OFF to ON 100 μs or less (with a load of 1 mA or more) K: -270.0 to 1372.0˚C
10 ms or less
time ON to OFF 200 μs or less (with a load of 1 mA or more) J: -210.0 to 1200.0˚C
Internal current consumption 70 mA or less 30 mA or less 30 mA or less 50 mA or less T: -270.0 to 400.0˚C
E: -270.0 to 1000.0˚C
Weight Approx. 130 g Approx. 100 g Approx. 120 g Approx. 110 g Pt100: -200.0 to 850.0˚C
Input range N: -270.0 to 1300.0˚C
Electrical: 100000 JPt100: -200.0 to 600.0˚C
R: -50.0 to 1768.0˚C
cycles or more S: -50.0 to 1768.0˚C
Relay life (20 cycles/minute) — B: 0.0 to 1820.0˚C
Mechanical: 20000000 WRe5-26: 0.0 to 2315.0˚C
cycles or more
Relay replacement Impossible —
±0.2% of F.S. (at 25°C ±5°C) ±0.2% of F.S. (at 25°C ±5°C)
*1 If‌ even a single overcurrent is detected, the protection operation (output turned OFF) and automatic Overall accuracy
±0.4% of F.S. (at 0 to 55°C) ±0.4% of F.S. (at 0 to 55°C)
recovery are repeated for all outputs within the shared common*4*5, until the cause of the problem is
removed. 100 Ω max./wire
Allowable wiring
— (no variation allowed
*2 ‌The KV-NC16ET(P), KV-NC16ET(P)E, and KV-NC32ET(P) COM terminals are shorted internally. resistance
among three wires)
*3 ‌The KV-NC8ER has four C0s and four C1s, and each set of C0s and C1s is shorted internally.
(The sets of C0s and C1s are independent.) Conversion speed 125 ms/channel
*4 ‌The outputs within the shared common that are protected when an overcurrent is detected are outputs 000 Between input terminals and base unit:
to 007 or 008 to 015 for the KV-NC16ET(P) and KV-NC16ET(P)E. Photocoupler/semiconductor relay/transformer isolation
*5 ‌The outputs within the shared common that are protected when an overcurrent is detected are outputs 000 Isolation method Between channels: (When resistance thermometer is not used):
to 015 or 100 to 115 for the KV-NC32ET(P). Semiconductor relay isolation;
*6 ‌Sink output types use MOSFET (N-ch) output. Source output types use MOSFET (P-ch) output. (When resistance thermometer is used): No isolation
*7 ‌The rated load of each common terminal is 1.6 A for the KV-NC16ET(P) and KV-NC32ET(P) and is 3.2 A Internal current consumption 40 mA or less
for the KV-NC16ET(P)E. Weight Approx. 110 g
*1 Individual setting is possible for each channel.

Specifications — A/D & D/A conversion unit


Model KV-NC4AD KV-NC2DA
Conversion A/D conversion D/A conversion
Analogue input points 4 (single end) 2
-10 V to +10 V 1/8000 2.5 mV 1/8000 2.5 mV
0 to 10 V 1/4000 2.5 mV 1/4000 2.5 mV
Voltage
Analogue input range/ 0 to 5 V 1/4000 1.25 mV 1/4000 1.25 mV
resolution 1 to 5 V 1/3200 1.25 mV 1/3200 1.25 mV
0 to 20 mA 1/4000 5 μA 1/4000 5 μA
Current
4 to 20 mA 1/3200 5 μA 1/3200 5 μA
Conversion speed 80 μs/channel*1 80 μs/channel
Without temperature ±0.3% of F.S. (at 25°C ±5°C)
compensation ±0.5% of F.S. (at 0 to 55°C) ±0.3% of F.S. (at 25°C ±5°C)
Voltage
With temperature ±0.5% of F.S. (at 0 to 55°C)
±0.3% of F.S.(at 0 to 55°C)
compensation
Conversion precision
Without temperature ±0.4% of F.S. (at 25°C ±5°C)
compensation ±0.6% of F.S. (at 0 to 55°C) ±0.3% of F.S. (at 25°C ±5°C)
Current
With temperature ±0.5% of F.S. (at 0 to 55°C)
±0.4% of F.S.(at 0 to 55°C)
compensation
Voltage 5 MΩ —
Input resistance
Current 250 Ω —
Absolute Voltage ±15 V —
maximum input Current ±30 mA —
Between analogue I/O and CPU Isolated (photocoupler, transformer)
Isolation method
Between analogue I/O channels Non-isolated
Minimum load resistance Voltage — 1 kΩ
Maximum load resistance Current — 600 Ω
*1 When the temperature fluctuation compensation is used, the temperature fluctuation compensation time of 80 μs will be added regardless of the number of channels being used.
20
Expansion unit specifications (screw terminal block type)

Specifications — Expansion input unit Specifications — Expansion I/O unit


KV-N8EX KV-N16EX Model KV-N8EXR KV-N8EXT
Model
(8 points) (16 points) (8 + 8 points) (8 + 8 points)
External connection method Terminal block External connection method Terminal block
Input terminals 24 VDC mode 5 VDC mode 24 VDC mode 5 VDC mode Number of inputs 8
Maximum input voltage 26.4 VDC Input mode 24 VDC mode 5 VDC mode 24 VDC mode 5 VDC mode
Rated input voltage 24 VDC/5.3 mA 5 VDC/1 mA 24 VDC/5.3 mA 5 VDC/1 mA Maximum input voltage 26.4 VDC
Minimum ON voltage 19 V 3.5 V 19 V 3.5 V Rated input voltage 24 VDC/5.3 mA 5 VDC/1 mA 24 VDC/5.3 mA 5 VDC/1 mA
Maximum OFF current 1.5 mA − 1.5 mA − Minimum ON voltage 19 V 3.5 V 19 V 3.5 V
Maximum OFF voltage − 1.5 V − 1.5 V Maximum OFF current 1.5 mA − 1.5 mA −
Common method 8 points/1 common (2 terminals)*1 16 points/1 common (2 terminals)*1 Maximum OFF voltage − 1.5 V − 1.5 V
Common method 8 points/1 common (1 terminal)*1

Input
Input time OFF to ON ON to OFF
constant setting Typ. Max. Typ. Max.
Input time OFF to ON ON to OFF
Input time constant 25 µs 10 µs 50 µs 50 µs 150 µs constant setting Typ. Max. Typ. Max.
(four-level switching) 300 µs 240 µs 290 µs 280 µs 390 µs 25 µs 10 µs 50 µs 50 µs 150 µs
1 ms 1 ms 1.2 ms 1 ms 1.2 ms Input time constant
300 µs 240 µs 290 µs 280 µs 390 µs
10 ms 10 ms 11 ms 10 ms 11 ms 1 ms 1 ms 1.2 ms 1 ms 1.2 ms
Input impedance 4.3 kΩ 10 ms 10 ms 11 ms 10 ms 11 ms
Internal current consumption 20 mA or less Input impedance 4.3 kΩ
Weight 150 g 220 g
Number of outputs 8
*1 The KV-N8EX and KV-N16EX have 2 COM terminals, but these are shared internally.
MOSFET (N-ch)
Output mode Relay (with overcurrent protection
function)*4
Specifications — Expansion output unit
Rated load 250 VAC/30 VDC, 2A 30 VDC, 0.5 A
Model KV-N8ER KV-N16ER KV-N8ET(P) KV-N16ET(P)
(8 points) (16 points) (8 points) (16 points) Leakage current at OFF − 100 µA or less

MOSFET output Residual voltage 0.8 VDC or less (with 0.5 A output)
Output mode Relay at ON −
With overcurrent protection function*3*5 0.6 VDC or less (with 0.3 A output)
Terminal block ON resistance 50 mΩ or less −
External connection method

Output
Rated load 250 VAC/30 VDC, 2A 30 VDC, 0.5 A Common method 4 points/1 common 8 points/1 common
(2 terminals)*1*2 (4 terminals)*1*3
Leakage current at OFF − 100 μA or less
0.8 VDC or less (with 0.5 A output) OFF to ON 100 μs or less
Residual voltage at ON − Operation (with a load of 1 mA or more)
0.6 VDC or less (with 0.3 A output) 10 ms or less
time 200 μs or less
ON resistance 50 mΩ or less − ON to OFF
(with a load of 1 mA or more)
4 points/1 common 8 points/1 common 16 points/1 common
Common method Independent Electrical: 100000 cycles or more
(8 terminals)*1 (4 terminals)*2 (8 terminals)*2*4
Relay life (20 cycles/minute)

100 μs or less Mechanical: 20000000 cycles or
OFF to ON
Response (with a load of 1 mA or more) more
time 10 ms or less Relay replacement Impossible −
200 μs or less
ON to OFF Internal current
(with a load of 1 mA or more) 60 mA or less 30 mA or less
consumption
Electrical: 100000 cycles or more
Relay life (20 cycles/minute) − Weight 230 g 210 g
Mechanical: 20000000 cycles or more *1 The input COM and output COM terminals are independent.
Relay replacement Impossible − *2 The KV-N8EXR has two C1 output terminals and two C2 output terminals, but each pair of these terminals
Internal current consumption is shared internally. (C1 and C2 are isolated.)
60 mA or less 100 mA or less 30 mA or less 40 mA or less
*3 The KV-N8EXT has four COM output terminals, but these terminals are shared internally.
Weight 230 g 260 g 160 g 210 g *4 If even a single overcurrent is detected, the protection operation (output turned OFF) and automatic
*1 ‌The KV-N16ER has two terminals for each of C0, C1, C2, and C3 respectively, which are shorted internally. recovery are repeated for all outputs within the shared common, until the cause of the problem is removed.
(C0, C1, C2, and C3 are independent.)
*2 The KV-N8ET(P) and KV-N16ET(P) COM terminals are shorted internally.
*3 ‌If even a single overcurrent is detected, the protection operation (output turned OFF) and automatic
recovery are repeated for all outputs within the shared common*4, until the cause of the problem is
removed.
*4 The outputs within the shared common that are protected when an overcurrent is detected are outputs 000
to 007 or 008 to 015 for the KV-N16ET(P).
*5 Sink output types use MOSFET (N-ch) output. Source output types use MOSFET (P-ch) output.

Specifications — Analogue I/O unit


Model KV-N3AM
Conversion A/D conversion D/A conversion
Number of points 2 (single end) 1
-10 V to +10 V 1/8000 2.5 mV 1/8000 2.5 mV
0 to 10 V 1/4000 2.5 mV 1/4000 2.5 mV
Analogue Voltage*1
0 to 5 V 1/4000 1.25 mV 1/4000 1.25 mV
I/O range and
resolution 1 to 5 V 1/3200 1.25 mV 1/3200 1.25 mV
0 to 20 mA 1/4000 5 μA 1/4000 5 μA
Current*1
4 to 20 mA 1/3200 5 μA 1/3200 5 μA
Conversion speed 80 μs/channel*2 80 μs/channel*2
Without temperature ±0.3% of F.S. (at 25°C ±5°C)
compensation ±0.5% of F.S. (at 0 to 55°C) ±0.3% of F.S. (at 25°C ±5°C)
Voltage
With temperature ±0.5% of F.S. (at 0 to 55°C)
±0.3% of F.S. (at 0 to 55°C)
Conversion compensation
precision Without temperature ±0.4% of F.S. (at 25°C ±5°C)
compensation ±0.6% of F.S. (at 0 to 55°C) ±0.3% of F.S. (at 25°C ±5°C)
Current
With temperature ±0.5% of F.S. (at 0 to 55°C)
±0.4% of F.S. (at 0 to 55°C)
compensation
Voltage 5 MΩ −
Input resistance
Current 250 Ω −
Absolute Voltage ±15 V −
maximum input Current ±30 mA −
Between analogue I/O and CPU Isolated (photocoupler, transformer)
Isolation method Between analogue input and output Non-isolated
Between analogue input channels Non-isolated −
Minimum load
Voltage − 1 kΩ
resistance
Maximum load
Current − 600 Ω
resistance
Internal current consumption 120 mA or less
Weight 200 g
*1 For the possible measuring range for out-of-range input, refer to “A/D and D/A conversion table” in “KV-N3AM User’s Manual.”
*2 When the temperature fluctuation compensation is used, the temperature fluctuation compensation time of 80 μs will be added regardless of the number of channels being used.

21
Dimensions

Communication unit Expansion unit (European terminal block/MIL connector type)

KV-EP02 KV-NC8ER KV-NC16EXE/ET(P)E


(20.3) 3.6 3.6

27.3 27.3 27.3

90 35.9 90 35.9 90 35.9


(37.6)

14.6 80.4 80.4


3.8 3.8 3.8
24.4 5.6 22.2 5.6 22.2
5.2 7.8 90.2 81.5
(20.7) (97)
26.7 80.4
(135.4)

Expansion unit (European terminal block/MIL connector type)

KV-NC16EX/ET(P) KV-NC32EX/ET(P) KV-NC32EXT


KV-NC16EXT
3.6 3.6 3.6

27.3 27.3 27.3

90 35.9 90 35.9 90 35.9

3.8 80.4 80.4 80.4


3.8
3.8
96.5 96.5 96.5
5.6 22.2 5.6 22.2 5.6 31.2 (125)
(130) (125)

KV-NC4AD KV-NC2DA KV-NC4TP


3.6 3.6 3.6

27.3 27.3 27.3

90 35.9 90 35.9 90 35.9

3.8 80.4 3.8 80.4 3.8 80.4


5.6 22.2 5.6 22.2 5.6 22.2
90.2 90.2 97

Expansion unit (screw terminal block type)

KV-N8EX/ET(P) KV-N8ER/EXR/EXT KV-N3AM


KV-N16EX/ER/ET(P)

37 57 47
2-ø4.5 2-ø4.5 2-ø4.5

27.3 27.3 27.3

90 82 35.9 90 82 35.9 90 82 35.9

3.8 3.8 3.8

45 83.7 65 83.7 55 83.7


17.2 17.2 17.2

Connection conversion unit Expansion unit extension cable

KV-NC1 KV-N1 OP-87581


3.6
18 1.2 43.5

27.3 27.3 6
27.3

90 35.9 90 35.9
58.2 73 36.8

5.6 22.2 22.2 2-ø4.6


3.8 80.4 3.8 80.4

22
Unit: mm

CPU unit Base unit

KV-7500/7300 With bus-connected unit KV-NC32T


1.4 95 85
1.2

27.3 27.3

92.5 35.9 92.5 90 35.9

90

55 4 4 80.4
55 22.6
43.6 3.8 96.5
16 16 (125)
16.6
15.6 15.6

12.9

16.9

Network unit

KV-XLE02 KV-NC1EP
1.2
3.6

27.3 27.3

92.5 35.9 90 90 35.9

95 3.8 80.4
4 22.2
5.6 (135)
8 36 150

Related products (network units)

Serial Communication
RS-422A/ Communication speed
Unit Hardware  RS-232C*1 2 ports
RS-485*2 230 kbps
KV-XL202/ PROTOCOL Modbus RTU
KV-XL402 PLC Link
STUDIO master/slave
Non-procedure
Functions 
Inter-unit
Unit interrupt
synchronisation
*1 KV-XL202 *2 KV-XL402

CC-Link unit
Transmission speed Trunk line length Input 896 points* Input 128 words
Hardware 
KV-CL20 10 Mbps 1200 m Output 896 points* Output 128 words

Functions  Remote I/O PLC Link

Mode  Master station Local station


*Maximum number of link points per local station

DeviceNet™ unit
Transmission speed Trunk line length Input 128 words*
Hardware 
KV-DN20 500 kbps 500 m Output 128 words

Functions  Remote I/O PLC Link

Master & slave


Mode  Master mode Slave mode *‌Maximum number of
mode
link points per slave

23
List of component devices

Remote I/O systems


Category Item name Model Functions/Specifications
Network EtherNet/IP™ compatible communication unit KV-EP02 2 ports, EtherNet/IP™, 100BASE-TX/10BASE-T
KV-NC16EXE 16 points, 5/24 VDC switchable, European terminal block
Input KV-NC16EX 16 points, 5/24 VDC switchable, 20-pin MIL connector × 1
KV-NC32EX 32 points, 5/24 VDC switchable, 34-pin MIL connector × 1
KV-NC8ER 8 points, relay output, European terminal block
KV-NC16ETE 16 points, transistor (sink) output, European terminal block
KV-NC16ET 16 points, transistor (sink) output, 20-pin MIL connector × 1
Output KV-NC16ETPE 16 points, transistor (source) output, European terminal block
KV-NC16ETP 16 points, transistor (source) output, 20-pin MIL connector × 1
Expansion unit KV-NC32ET 32 points, transistor (sink) output, 34-pin MIL connector × 1
(European terminal block/
KV-NC32ETP 32 points, transistor (source) output, 34-pin MIL connector × 1
MIL connector type)
KV-NC16EXT Input 16 points/output 16 points, transistor(sink) output, 34-pin MIL connector × 1
Input/output
KV-NC32EXT Input 32 points/output 32 points, transistor(sink) output, 34-pin MIL connector × 2
Voltage, current input 4 ch; conversion speed: 80 μs/ch;
A/D conversion KV-NC4AD
resolution: 1/4000; conversion precision: 0.3% (25°C ±5°C); European terminal block
Voltage, current output 2 ch; conversion speed: 80 μs/ch;
D/A conversion KV-NC2DA
resolution: 1/4000; conversion precision: 0.3% (25°C ±5°C); European terminal block
Temperature input KV-NC4TP Thermocouple and platinum resistance thermometer 4 ch, conversion speed: 125 ms/ch, European terminal block
Connection conversion unit KV-NC1 For connecting terminal block type expansion units
KV-N8EX 8 points, 5/24 VDC switchable, screw terminal block
Input
KV-N16EX 16 points, 5/24 VDC switchable, screw terminal block
KV-N8ER 8 points, relay output, screw terminal block
KV-N8ET 8 points, transistor (sink) output, screw terminal block
KV-N8ETP 8 points, transistor (source) output, screw terminal block
Output
KV-N16ER 16 points, relay output, screw terminal block
Expansion unit (screw KV-N16ET 16 points, transistor (sink) output, screw terminal block
terminal block type) KV-N16ETP 16 points, transistor (source) output, screw terminal block
KV-N8EXR Input 8 points/output 8 points, relay output, screw terminal block
Input/output
KV-N8EXT Input 8 points/output 8 points, transistor (sink) output, screw terminal block
Voltage, current input 2 ch/voltage, current output 1 ch; conversion speed: 80 μs/ch;
A/D-D/A conversion KV-N3AM
resolution: 1/4000; conversion precision: 0.3% (25°C ±5°C); screw terminal block
Connection conversion unit KV-N1 For connecting European terminal block/MIL connector type expansion units
Screw terminal block unit extension cable OP-87581 Cable length: 1 m, cable width: 2 cm

KV-7000 Series
Category Item name Model Functions/Specifications
CPU unit with built-in EtherNet/IP™ port KV-7500 Program capacity: 1500k steps, LD command processing speed: 0.96 ns, EtherNet/IP™ port, USB port (USB 2.0), CPU inner bus
CPU
CPU unit with built-in serial port KV-7300 Program capacity: 160k steps, LD command processing speed: 0.96 ns, RS-232C port, USB port (USB 2.0), CPU inner bus
2 ports; support for EtherNet/IP™, EtherCAT® (slave), CC-Link IE Field (intelligent device station), and PROFINET (device);
Network Ethernet unit KV-XLE02 1000BASE-T/100BASE-TX/10BASE-T; PLC Link function; PROTOCOL STUDIO mode; FTP client/server function; unit interrupt;
inter-unit synchronisation
Power supply AC power supply unit with error output KV-PU1 Output capacity: 1.8 A; Relay output: rated load of 24 VDC, 0.5 A

KV Nano Series
Category Item name Model Functions/Specifications
CPU Connector type base unit KV-NC32T Program capacity: 32k steps, RS-232C port, USB port, 16 inputs/16 outputs, transistor (sink) output
Network EtherNet/IP™ unit KV-NC1EP 1 port, EtherNet/IP™, 100BASE-TX/10BASE-T

Related products
Category Item name Model Functions/Specifications
NE-Q05P 5 ports, 24 VDC, QoS function, PoE supported
Industrial Ethernet switch EtherNet/IP™ compatible Ethernet switch
NE-Q05 5 ports, 24 VDC, QoS function
NU-EP1 N-bus supported, PoE supported
Network EtherNet/IP™ compatible communication unit
DL-EP1 D-bus supported

Software
Category Item name Model Functions/Specifications
Programming support
KV STUDIO Ver. 9 KV-H9G DVD-ROM, Windows 10/8/7/Vista/XP-compatible, site licence*
software
* Through user registration, the software can be used by multiple people associated with the office (including factories, business offices, and sales offices) that purchased the software.

SAFETY INFORMATION
Please visit: www.keyence.com Please read the instruction manual carefully in
order to safely operate any KEYENCE product.

GLOBAL NETWORK CONTACT YOUR NEAREST OFFICE FOR RELEASE STATUS

AUSTRIA CZECH REPUBLIC INDIA MALAYSIA ROMANIA TAIWAN


Phone: +43-2236-378266-0 Phone: +420-220-1847-00 Phone: +91-44-4963-0900 Phone: +60-3-7883-2211 Phone: +40-269-232-808 Phone: +886-2-2721-8080

BELGIUM FRANCE INDONESIA MEXICO SINGAPORE THAILAND


Phone: +32-15-281-222 Phone: +33-1-56-37-78-00 Phone: +62-21-2966-0120 Phone: +52-55-8850-0100 Phone: +65-6392-1011 Phone: +66-2-369-2777

BRAZIL GERMANY ITALY NETHERLANDS SLOVAKIA UK & IRELAND


Phone: +55-11-3045-4011 Phone: +49-6102-3689-0 Phone: +39-02-6688220 Phone: +31-40-20-66-100 Phone: +421-25939-6461 Phone: +44 1908-696-900

CANADA HONG KONG JAPAN PHILIPPINES SLOVENIA USA


Phone: +1-905-366-7655 Phone: +852-3104-1010 Phone: +81-6-6379-2211 Phone: +63-2-981-5000 Phone: +386-1-4701-666 Phone: +1-201-930-0100

CHINA HUNGARY KOREA POLAND SWITZERLAND VIETNAM


Phone: +86-21-5058-6228 Phone: +36-1-802-73-60 Phone: +82-31-789-4300 Phone: +48-71-36861-60 Phone: +41-43-455-77-30 Phone: +84-24-3772-5555

The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice. WW1-1078
Company and product names mentioned in this catalogue are either trademarks or registered trademarks of their respective companies.
Copyright © 2018 KEYENCE CORPORATION. All rights reserved. Ethernetsystemcatalog-WW-C2-GB 1108-1 600R58

You might also like