You are on page 1of 20

`

SINGLE-MODE FIBER DROP CABLE


(G.657.A1)

Product Specification

`
`

CONTENTS

A. Overview……………………………………….……………. 1
B. Features………………………………………….…………… 1
C. Technical Parameters…………………………..…...... 2
D. Product Structure
D.1 Dimension…………………………………...…..... 4
D.2 Structure………………….………….………….….. 5
E. Installation Procedure…………………………………. 6

`
`

OVERVIEW

Fiber Drop Cable is mainly designed to apply for the last link in
the optical network (FTTx such as Fiber to the Home, FTTH, such as Fiber
to the Building, FTTB) which terminates the fiber from the optical splitter
distribution closure or optical distribution point to the premise
termination box at the customer place.

FEATURES

• Features:
• Single Mode
• Low friction
• Flat-Type with Strength Members
• High Temperature Stability
• LSZH Outer Sheath

Page 1 of 9
`

TECHNICAL PARAMETERS

@1310nm ≤0.36dB/km

@1383nm ≤0.35dB/km
Attenuation Coefficient of
Cable
@1550nm ≤0.25dB/km

@1625nm ≤0.28dB/km

Cable cut-off wavelength ≤1260nm

Zero-dispersion slope ≤ 0.090 ps/nm².km

@1285-1625nm ≤3.50 ps/nm².km


Chromatic dispersion
@1550nm ≤ 18.0 ps/nm².km

Mode field diameter @1310nm 8.6 ± 0.4 µm

Core/Clad concentricity error ≤ 0.5 µm

Cladding diameter 125 ± 1.0 µm

Cladding non-circularity ≤ 0.5 %

Primary Coating Diameter 245 ± 10 µm

Proof Test Level 1%, 100kpsi

Page 2 of 9
`

TECHNICAL PARAMETERS

20mm radius ≤ 0.1dB/km


Macro Bending Loss
@1550nm
30mm radius ≤ 0.1dB/km

Max Tension 500/1000 (N)

Max. Crushing Resistance 300/1000 (N/100mm²)

Min. Bending Radius 15D (Dynamic) /10D (Static)


Storage and operating
-40°C-+70°C
temperature
CABLE STRUCTURE

Number of Optical Fiber 1/2/4/6


Fiber Reinforced Plastic
Material
(FRP)
Strength Member
Number 2

w/messenger wire 2.2mmx5.3mm


Cable Size w/messenger wire:6C 2.2mmx5.7mm
w/out messenger wire 2.2mmx3.00mm
LSZH (OD:
Material
2.2+2.0*3.0±0.1mm)
Outer Sheath
Color Black
`

Page 3 of 9
`

DIMENSION

1-4C 6C

5.3mm 5.7mm

3mm 3mm

2.2mm 2.2mm

Page 4 of 9
`

STRUCTURE

Messenger Wire

Outer Sheath

Optical Fiber

Strength Member

6CORE

1CORE 2CORE 4CORE

Page 5 of 9
`

INSTALLATION

Tools

Page 6 of 9
`

INSTALLATION

Step 1

Insert the boot into


the cable.

Step 2

Remove the jacket to expose


the buffer coating using fiber
optic cable stripper. The
length should be at least
45mm.

Step 3

Remove the buffer coating to


expose the bare fiber using
miller clamp and guide rail.
Keep a length of 17mm buffer
coating.
`

Page 7 of 9
`

INSTALLATION

Step 4

Clean the bare fiber with lint


free tissue and 99.9% IPA.
Check the fiber for any
damage.

Step 5

Cleave the bare fiber at 12mm


using optical fiber cleaver (FC-
6S).

Step 6

Ensure the unlock clip (gray) is


inserted in the connector.
Then insert the bare fiber into
the connector body.

Note: the cable should have a


microbend (NOT exceed the height of
1mm)
`

Page 8 of 9
`

INSTALLATION

Step 7

Fasten the boot into the


connector body.

Step 8

Remove the unlock clip.

Page 9 of 9
CHina Telecommiunication Technology Labs
Report Code :F15X75282

Reprot Cord: F15X75282

TEST REPORT

Model : GJYXFCH-2B6
NAME: Access Network wireline Drop Cable_(Non-metallic Strength member)

Applicant : Nanjing Huamai Technology Co., LTD


Test Category : Product Certification Supervision And Inspection

China Telecommunication Technology Labs


CHina Telecommiunication Technology Labs
Report Code :F15X75282

China Telecommunication Technology Labs

TEST REPORT
Access Network Wireline
Product Bow-type Drop Product model
GJYXFCH-2B6
name Cable(Non-metallic Specifications
Strengh member)
Nanjing Huamai Inspection Product Certification
Applicant
Technology Co., Ltd. category Supervision and Testing
factory No. /
Production Nanjing Huamai 2015.10.15 /
Production
unit Technology Co., Ltd. 1505110175401
Date
No.66, Fengze Road,
Industrial Zone,
Production Dongshan Street, Sample Finished Products
Address Jiangning District, Location warehouse
Nanjing, Jiangsu
Province
Sampling
November 10, 2015 Sampler Gao Sihong
date
sample Number of
20 sets 1 plate (1.1km)
base samples
Sample
Sample initial state in good condition, meet inspection requirements
initial state
Inspection
YD / T 1997-2009 << Access Network Wireline Bow-type Drop Cable >>
basis
The company's GJYXFCH-2B6 Access Network Wireline Bow-type Drop
Cable (Non-metallic Strengh member self-supporting) products have been
Inspection tested, the results are as follows:
Conclusion 20 projects should be measured; 15 projects under the project; irrelevant
items 5; unqualified items 0, (B class 0: C class 0). Comprehensive
judgment:The sample is qualified for the test results .

1. Inspection of personnel based on: Tail Certification Center Power of


Attorney No. 1310035J2, " Cable equipment certification implementation
Remarks
rules" (VF.0)
2. The subcontracting test item name is indicated by an *.

Approve : review: Principal inspector:

Test Report on access network with drop cable


CHina Telecommiunication Technology Labs
Report Code :F15X75282

Inspection List

Unqulified Classfies
NO. TEST ITEM Conclusions
CLASS B CLASS C
1 Cable Construction &Size 〇 Qualified

2 Cladding diameter 〇 Qualified

3 Cladding non-circularity 〇 Qualified

4 Core/Clad concentricity error 〇 Qualified

5 Mode Field Diameter 〇 Qualified

6 Cut-off wavelength 〇 Qualified

7 Attenuation characteristic 〇 Qualified

8 Width of fiber array 〇 Irrelative

9 Thickness of fiber array 〇 Irrelative

10 Adjacent fiber spacing of fiber array 〇 Irrelative

11 Sides fiber spacing of fiber array 〇 Irrelative

12 Evenness of fiber array 〇 Qualified

13 Separability 〇 Qualified

14 Tensile 〇 Qualified

15 Crush 〇 Qualified

16 Impact 〇 Qualified

17 Repeat bending 〇 Qualified


18 Torsion 〇 Qualified
19 Buckling 〇 Qualified

20 Flame retardancy 〇 Qualified

NO CONTENT
CHina Telecommiunication Technology Labs
Report Code :F15X75282

TEST CONSEQUENCE
1.Cable structure & Size

No. Test Item Unit Standrad Request Test Conclusion Conclusion

(2.0±0.1)X(3.0
1 Structure & size mm 2.0 X 3.0 Qualified
±0.1)

2.Cable geometry、Optical Transmission & Mechanical Properties

Standrad
No. Test Item Unit Test Conclusion Conclusion
Request
Test Test
2 fiber fiber Qualified
value value
Cladding diameter μm 125.0±0.7
1 125.1 2 124.9 Qualified

3 Cladding non-circularity / ≤0.1 1 0.20% 2 0.20% Qualified

4 Core/Clad concentricity error μm ≤0.5 1 0.2 2 0.2 Qualified


(8.6~9.5)
5 Mode Field Diameter μm 1 8.7 2 8.7 Qualified
±0.4
6 cut-off wavelength nm ≤1260 1 1197 2 1203 Qualified
1310nm:
1 0.33 2 0.34 Qualified
≤0.4
7 attenuation characteristic dB/km
1550nm:
1 0.22 2 0.22 Qualified
≤0.3

3. Size of Fiber Array

NO. Test Item Unit Standrad Request Test Conclusion Conclusion

8 Width --- This is not Fiber Array Cable irrelative sets


9 Thickness --- This is not Fiber Array Cable irrelative sets
Adjacent
10 --- This is not Fiber Array Cable irrelative sets
fiber spacing μm
Sides fiber
11 --- This is not Fiber Array Cable irrelative sets
spacing
12 Evenness --- This is not Fiber Array Cable irrelative sets
No Content
CHina Telecommiunication Technology Labs
Report Code :F15X75282

4.The mechanical properties of the cable

No. Test Items Unit Standard Requirements Test Results Conclusions

Min: 3 5
N Tearing force Qualified
Max: 10 7
13 Separability Meet the
The separated fiber should meet the
------- requirements Qualified
requirements of c in standard 6.4.3.2.

Fiber strain ≤0.2 in long-term tension


0.15%
under the 300N
------
Fiber strain≤ 0.4 in short-term tensile
0.22%
strength of 600N
Fiber additional attenuation ≤ 0.03 in
0.01 Qualified
14 Tensile long-term tension under the 300N
dB
residual additive attenuation≤ 0.03 after
0.00
the test
Sheath without
After the test, the sheath without visible
------ visible cracking
cracking

Additional attenuation ≤0.03 in long-term


0.01
pressure 1000N / 100mm
dB
Additional attenuation of ≤0.4 under Qualified
15 Crush 0.02
short-term pressure 2200N / 100mm
After the test sheath without visible Sheath without
------
cracking visible cracking
Weight 1N, fall from a height of one
dB meter ,each time from three points, 0.04
Qualified
16 Impact residual attenuation ≤ 0.4 after the test
After the test sheath without visible Sheath without
------
cracking visible cracking
Load 20N, bending radius 30H, additional
dB 0.05
Repeat attenuation ≤ 0.4 after 300 times test
17 Qualified
bending After the test sheath without visible sheath without
------
cracking visible cracking
dB tension 20N, by torsion length 1m,
dB 180 degrees, residual additional decay 0.04
18 Torsion ≤0.4 after 20 times tests Qualified
After the test sheath without visible Sheath without
------
cracking visible cracking
CHina Telecommiunication Technology Labs
Report Code :F15X75282

TEST CONSEQUENCE
4.The mechanical properties of the cable
No. Test items unit Standard requirements Test results Conclusions

Minimum ring diameter: double the


static bending radius of the cable. Force
19 Buckling ----- Do not Buckle Qualified
direction: cable flat direction. After the
test, the cable should not bend.

5.The environmental performance of the cable


No. Test items Standard requirements Test results Conclusions
unit
Flame
Distance between carbonized part upper
retardancy
margins and lower edge of upper bracket 382
(single
≥50
vertical
20 burning test) mm Qualified

Distance between lower margins of lower


edge of upper bracket ≤540
478

No Content
CHina Telecommiunication Technology Labs
Report Code :F15X75282

Sample Information
1. The description of the sample
Non-metallic Strength Member Wireline Bow-type Drop Cable ,2 Cores.

2. Key material information of the sample


Check Attachment

3. Photo of the sample

Certification
Name: Wireline Bow-type Drop Cable Model: GJYXFCH(F1)-2B6
Code:150511017 5401 Color code:BL
Attenuation: ≤0.34/0.22 dB/km Length: 1100 m
Date of manufacture:2015.10.15 Inspetor: Limin Chen

Manufacturer : Nanjing Huamai Technology Co.,Ltd TEL:025-52707016

GJYXFCH-2B6
Access Network Wireline Bow-type Drop Cable (Non-metallic Strengh member)
CHina Telecommiunication Technology Labs
Report Code :F15X75282

The Main Instruments For Test, Test Conditions /


Environment and Other
Remarks
No. Equipment Type Model No.

1 Vernier caliper 0-100mm 13473

Fiber geometric
2 PK2400 53172495
parameters tester
Fiber integrated
3 PK2500 55242887
parameter tester
Fiber domain
4 PK8000 8000420
reflectometer
Micro-control
5 electronic tensile LWK-250 037
machine
Fiber
mechanical and
6 VI type 20080301
physical property
test system
Single vertical
7 DR-1 199
burner

Inspection instructions :

None.

Test Location China Telecommunication Technology Labs(Minor Western Heaven)

Test Date 11.25.2015 to 12.8

Test
Temperature: (20~25)℃ relative humidity:(20~40)%
Environment

Tingting Li Checker Feixie


Examiner
CHina Telecommiunication Technology Labs
Report Code :F15X75282

Attachment :
Key Material Information Of The Sample

Report Code:F15X75282
Applicant : Nanjing Huamai Technology Co.,Ltd

Product Name: Access Net Work Wireline Bow-type Drop Cable (Non-metallic

Strengh Member)

Product Model : GJYXFCH-2B6


Material Name Model Manufacturer
Fiber G.657A2 Nanjing Wasin Fujikura Optical Communication Co.,

Ltd

Outer Jacket WD-XD10-05 Suzhou Xinde cable plastic Co., Ltd.


Strength Member KFRPφ0.5xφ0.58mm Nantong Longtai Communication Material
Technology Co., Ltd

China Telecommunication Technology Labs


2015.12.9

--------No Content--------