You are on page 1of 1

TYPICAL TOP RFG DIMENSION INFORMATION

SLAB THICKNESS
CONC COVER
0.25 L1 0.33 L U/N 0.33 L U/N
0.20 L U/N 0.20 L U/N
Ld STAG DIST BAR LENGTH = 0.53 L U/N

TOP RFG

0
ROTATE HOOKED
BAR AS REQD
TO FIT IN SLAB

0
BOT RFG CHAIR BARS

CONC COVER
1x1/2 REGLET AT
REFER TO NOTES
POUR JOINT TS

CONC WALL CHAIR BARS CONC BEAM OR WALL CONC BEAM OR WALL CONC BEAM OR WA
REFER TO NOTES RFG NOT SHOWN RFG NOT SHOWN RFG NOT SHOWN

0.125 L1 U/N 0.125 L2 U/N 0.125 L2 U/N 0.125 L3 U/N 0.125 L3 U/N 0.125 L4 U/N
L1 L2 L3 L4

C
L EXTERIOR L PENULTIMATE
C C
L OTHER C
L OTHER
SUPPORT SUPPORT INTERIOR INTERIOR
SUPPORTS SUPPORTS

TYPICAL ONE WAY SLAB SUPPORTED ON CONC BEAMS


NTS

NOTES
PLACE REBAR FOR ONE WAY SLABS AS SHOWN U/N
L = MAX LENGTH OF SPAN ON EITHER SIDE OF SUPPORT
L TO BE BASED ON CLEAR SPANS FOR CONCRETE BEAMS
AND CENTRE TO CENTRE OF SPANS FOR STEEL BEAMS
STAGGER TOP BARS AS SHOWN
PROVIDE SUPPORT BARS AND CHAIRS TO CSA A23
PROVIDE TS EQUAL TO 0.2% OF SLAB AREA
TS SPACING TO BE 3 TIMES SLAB THICKNESS BUT NOT TO EXCEED 24"
WHERE MIN EMBEDMENT IS NOT POSSIBLE, PROVIDE 90° HOOK.
PROVIDE CLASS 'B' TENSION LAP SPLICE FOR BOT RFG AND TS U/N

TYPICAL TOP RFG DIMENSION INFORMATION


SLAB THICKNESS
CONC COVER

0.33 L U/N 0.33 L U/N


0.20 L U/N 0.20 L U/N
Ld STAG DIST BAR LENGTH = 0.53 L U/N

TOP RFG

0
ROTATE HOOKED
BAR AS REQD
TO FIT IN SLAB

1x1/2 REGLET AT 10 db BUT NOT TO


BOT RFG
CONC COVER

POUR JOINT BE LESS THAN 6"


TS
PROVIDE 1x1/2
POLYURETHANE
CAULKED JOINT C/W
ETHAFOAM SILL GASKET
BOND BREAKER

L PENULTIMATE
C C
L INTERIOR C
L INTERIOR
SUPPORT SUPPORT SUPPORT

0.125 L1 U/N 0.125 L2 U/N 0.125 L2 U/N 0.125 L3 U/N 0.125 L3 U/N 0.125 L4 U/N

L1 L2 L3 L4
C
L EXTERIOR L PENULTIMATE
C C
L OTHER C
L OTHER
SUPPORT SUPPORT INTERIOR INTERIOR
SUPPORTS SUPPORTS

TYPICAL ONE WAY SLAB SUPPORTED ON STEEL BEAMS


NTS

NOTES
PLACE REBAR FOR ONE WAY SLABS AS SHOWN U/N
L = MAX LENGTH OF SPAN ON EITHER SIDE OF SUPPORT
L TO BE BASED ON CLEAR SPANS FOR CONCRETE BEAMS
AND CENTRE TO CENTRE OF SPANS FOR STEEL BEAMS
STAGGER TOP BARS AS SHOWN
PROVIDE SUPPORT BARS AND CHAIRS TO CSA A23
PROVIDE TS EQUAL TO 0.2% OF SLAB AREA
TS SPACING TO BE 3 TIMES SLAB THICKNESS BUT NOT TO EXCEED 24"
WHERE MIN EMBEDMENT IS NOT POSSIBLE, PROVIDE 90° HOOK.
PROVIDE CLASS 'B' TENSION LAP SPLICE FOR BOT RFG AND TS U/N

Ld

ROTATE HOOKED
BAR AS REQD
TO FIT IN SLAB

10 db BUT NOT TO 10 db BUT NOT TO


1x1/2 REGLET AT BE LESS THAN 6" 1x1/2 REGLET AT BE LESS THAN 6"
POUR JOINT POUR JOINT
Ld

CONC WALL

CONC WALL

CONC WALL

CONC WALL
Ld

ROTATE HOOKED
BAR AS REQD
TO FIT IN SLAB

10 db BUT NOT TO
10 db BUT NOT TO 1x1/2 REGLET AT BE LESS THAN 6"
BE LESS THAN 6" POUR JOINT
Ld

CONC BEAM

CONC BEAM
CONC WALL

CONC WALL