You are on page 1of 3

Dyckerhoff

MIKRODUR® MICROFINE Cements

Types: P, R
Grading: X (extrafine) d95 ≤ 6 µm
U (ultrafine) d95 ≤ 9,5 µm
F (fine) d95 ≤ 16 µm

Dyckerhoff MIKRODUR
- Examples of Grain Size Distributions compared to OPC -
100
d95

80
Minus Mesh [w.-%]

60

40 CEM I 32,5
CEM I 52,5
Grading F
20 Grading U
Grading X

0
1
1 2 4 6 8 10
10 20 40 60 100
100
Grain Size [µm]

Grouting binders
Product Dyckerhoff MIKRODUR® are Portland cement clinker (“P” Types) or granulated blast furnace slag
based (“R” Types) microfine cements designed for grouting into soil, rock and concrete.
Dyckerhoff MIKRODUR® feature a maximum particle size from d95 ≤ 6 µm to d95 ≤ 16 µm.
Dyckerhoff MIKRODUR® type R is comparable to cements with high sulphate resistance
according to DIN 1164-1.

Field of applications Geotechnical grouting (soil, rock)


Grouting into concrete structures (cracks and voids in concrete / masonry)
Additive in mortar or concrete (improves flowability, early strength and durability)

Specifications Dyckerhoff MIKRODUR® P and R

This bulletin contains general Type P-U P-F R-X R-U R-F
information only. It cannot
consider chemical and/or Bulk Specific Gravity [kg/dm³] ~ 0,8 ~ 0,7
physical influences of
Absolute Density [kg/dm³] ~ 3,1 ~ 2,9
substances unknown to us
having any contact with our Specific Surface, Blaine
products at mixing or in any ~ 1600 ~ 1200 ~ 1900 ~ 1600 ~ 1200
[m²/kg]
other way at work on the
construction site. Hence the Grain Size d50 [µm] ≤ 3,5 ≤5 ≤ 2,5 ≤ 3,5 ≤5
information is perhaps not
suitable for the actual Grain Size d95 [µm] ≤ 9,5 ≤ 16 ≤6 ≤ 9,5 ≤ 16
application. In this case
individual tests considering Setting Time* [min]
the actual on-site conditions
start ~ 120 ~ 150
are necessary. The
information in this bulletin end ~ 180 ~ 200
cannot be seen as a quality
guarantee. Indemnification Compressive Strength* [MPa]
and quality claims due to the
information in this bulletin 1 day ≥ 50 ≥ 35 ≥ 25 ≥ 10 ≥5
are excluded in general.
2 days ≥ 60 ≥ 55 ≥ 45 ≥ 35 ≥ 15
Court of jurisdiction:
Wiesbaden, Fed. Rep. Of 28 days ≥ 70 ≥ 70 ≥ 70 ≥ 70 ≥ 65
Germany.
* Tests acc. to EN 196-1 and 3 at 20°C / 68°F (For technical reasons sample preparation with Dyckerhoff MSH flüssig (FM) for P-U type)

Dyckerhoff MIKRODUR R-U: Examples for grout formulations

Water / MIKRODUR-ratio 1,0 2,0


Admixture* BWOM** [w.-% ] 3,0 3,0
Water BWOM per 25 kg bag [l ] 25 50
Admixture BWOM per 25 kg bag [kg] 0,75 0,75
MIKRODUR grout per 25 kg bag [l ] ~ 33 ~ 58
Grout density [kg/l ] ~ 1,49 ~ 1,29
Run out time (Marsh´s funnel device) [sec/dm³]
0 minutes ~ 32 ~ 31
30 minutes ~ 32 ~ 31
60 minutes ~ 33 ~ 32
Bleeding [Vol.-% ]
120 min ≤2 ≤5
Compressive Strength [MPa]
1 day ≥3 ≥ 0,5
7 days ≥ 10 ≥5
28 days ≥ 15 ≥ 7,5
* Admixture Dyckerhoff MSH flüssig (FM); Producer: Grace Bauprodukte GmbH, D-32676 Lügde
** BWOM = by weight of MIKRODUR
Tests according to “Instruction leaflet for grouting works with microfine cements in soil (2002)” at 20°C/68°F

2
Dyckerhoff MIKRODUR type P and R grout must always be prepared with the dispersant Grout Preparation
Dyckerhoff MSH flüssig (FM). Grout preparation must be done in colloidal mixers or other equivalent
high-speed mixers in the following mixing order:
1. Water
2. Dyckerhoff MSH flüssig (FM) (Mixing time: approx. 30 seconds)
3. Dyckerhoff MIKRODUR (Mixing time not less than 3 minutes)
The recommended time of workability after mixing is up to 60 minutes. The slurry should be moved
continuously during the grouting process. Grout characteristics should be checked according to
“Instruction leaflet for grouting works with microfine cements in soil”.

Grading List of Products


Types in supply F (fine) U (ultrafine) X (extrafine)
(d95 ≤ 16 µm) (d95 ≤ 9,5 µm) (d95 ≤ 6 µm)
MIKRODUR P
MIKRODUR R
MIKRODUR R-E/plus
MIKRODUR rock

Packaging
bulk
big bag
25 kg paper bags (3-layers with PE-coating), wrapped plus additional plastic cover
40 bags (1000 kg) on one-way pallet
MIKRODUR in bags can be delivered also in 20`or 40`containers.

Availability and Time of


All MIKRODUR products are worldwide available. The delivery time depends on the destination, Delivery
amount and packaging. Please ask us for further information.

Freshly mixed MIKRODUR grout can cause skin irritations. Avoid contact with skin where possible Safe Handling and Storage
and wash exposed skin promptly with water. Use dust mask when breaking bags and mixing. If
cement grout gets into the eye, rinse immediately and repeatedly with water for 15 minutes and seek
prompt medical attention. MIKRODUR must be stored in dry locations. In original and undamaged
bags the shelf-life of MIKRODUR is 6 month. After longer storage periods MIKRODUR should be
checked before each application.
The water soluble chromate content in MIKRODUR is below 2 ppm.

All MIKRODUR products were tested through Hygiene-Institut, D-45879 Gelsenkirchen, accredition Environmental Aspects
number DAP-PL-2548.00, issued by Deutscher Akkreditierungsrat (German Accredition Council).
All existing test reports can be requested.

Dyckerhoff AG Contact
Export Department
P.O. Box 2247
D-65012 Wiesbaden
phone. +49 611 676 1311
fax: +49 611 676 1285
mail: export@dyckerhoff.com