You are on page 1of 2

TELECOMMUNICATIONS

Public Address System

„„ Fully remote- controlled and supervised public


address system with power output of up to
300 W for 100 V distribution for the version
with 230 V AC power supply and 150 W for
the version with 48 V DC power supply.
„„ Integrated input VoIP for direct connection to
the digital infrastructure
„„ 6 output loops with separate indications of
currently broadcasted messages
„„ Communication and control by standard
protocols (HTML, SNMP, NTP, SYSLOG)
„„ Option of direct coupling with the automatic
announcement system

General description plifier it includes functions needed tion of the current state, control
The public address system has been for remote operation and supervi- and configuration are possible by
designed as a replacement of the ex- sion of the operating conditions. website browser. Current operating
isting RU-6 public address systems The basic input of the low frequency states and information from the in-
and of other similar equipment dur- signal is an Ethernet interface with ner auto-diagnostics can be trans-
ing the transition to the remote con- VoIP Protocol and the option of mitted into the superior supervisory
trol system. It includes a high-power the simultaneous operation of two system by SNMP Protocol and it is
low frequency amplifier 300 W 100 V, independent channels. The first possible to record the operation his-
control circuits for supervision, VoIP channel is designed for connecting tory by SYSLOG Protocol. The inter-
circuits for the input of low-frequen- to the centralized announcement nal real time clock can be synchro-
cy signal in the digital form. Besides system, the second channel for local nized using the NTP protocol.
the standard features of the LF am- or remote access using VoIP phone.
The other con- The basic technical description
necting options The public address system is built-in
TOP of the low- in the case designed for installation
frequency signal to 19“ rack, height 3U and depth of
Central radio
are the line input 40 cm. Its weight is 18 kg. The front
office and the micro- panel includes two Ethernet connec-
LAN RAILWAY STATION phone input. All tors (one for connecting into the sys- AC
settings of ana- tem, the second for connecting of 00
16
logue param- the service technician), LEDs indicat-
eters (volume, ing the current state of the lines
Loudspeakers heights, basses, and of the public address system
levels of individ- itself, and alphanumeric LCD display
WAN ual inputs and
RV3 server their priorities)
are carried-out
Interconnection diagram of the Public Address System with digitally. Detec-
the environment

www.azd.cz
showing details of the current state. ment system, where compared with Protocol from the network and it
In addition, the front panel includes the existing equipment the use of an allows as well automatic switching
connectors for connecting analogue external computer with the sound of the day and night mode. To check
recording, line output and micro- card is not necessary. Other options the carried-out announcements
phone output. On the rear panel are the local or remote announce- current flowing through the line is
there are EURO plugs for connect- ments via the standard VoIP network measured in each of the six output
ing 230 V power supply and con- with a variable priority. For these lines. Input circuits formed by an
nectors for connecting the output two options the public address output transformer, relay switching
lines. Cooling is forced by ventila- system uses two independent VoIP the output lines and output current
tors, the coolers are located inside inputs. It is also possible to con- sensor are galvanically separated by
the public address system case. nect the input signal to the line or 4kV insulation barrier.
to the microphone input. Inputs
The regular operation is expected to use adjustable priorities. Real time
proceed in the automatic announce- circuit is synchronised by NTP

Basic technical parameters


19“ module height 3U and depth 40 cm (without connectors), width
(without handles) 43 cm, depth 40 cm, height 9 cm
Dimensions
The Public Address System has been designed for installation into 19“ (rack)
distributor, vents on the front and rear panel must not be covered
Weight 18 kg
Cover IP20
Working temperature range 0 to 45 °C
Storage temperature range –20 to 60 °C
Humidity 20 to 80 % non-condensing
230 V ±10% 50 Hz, max. 8 A ( the 300 W version), or 48 V DC max. 10 A
Rated power supply voltage
(the 48 V version)
Output power till 100V of 300 W (the 230 V power supply version) or 150 W (the 48 V power supply
distribution version)
The number of output loops 6
LAN (Ethernet) – 2× RJ45
230V intake – EURO plug
48V intake – two pole connector
Connectors Output lines - 2 two-pin plugs PA256/7,62, cable plugs PA256/7,62 are
included in the source supply
Microphone input, line input and output for analogue recording – RJ11
plugs

C