ISOLATED FOOTING DESIGN CALCULATION

P= 150 kN
Type F1

Location

Maxm Colm Load on Ftg., P 150 kN

Size of Column 200 400 mm x mm

Allowable Safe Bearing Capacity, SBC 150 kN/m2


qn= 96.15 kN/m2
Area Reqd. = P x 1.1/SBC 1.10 m 2

Select Ftg. Size, B x L 1.20 x 1.30 mxm


B= 1.20
Area Provided 1.56 m2 OK

Net Upward Pressure, qn 96.15 kN/m2


L= 1.30
Consider 1m strip:

Short Way: Moment/metre, Msw 12.02 kN-m/metre

Long Way: Moment/metre, Mlw 9.74 kN-m/metre


FC = 25 N/mm2
Assume Allowable punching shear stress 1.25 N/mm2 .25*Fc^.5 IS CODE

Depth Reqd. from Punching Shear consideration = 94.87 mm

Use D = 300 mm Use Ysw = 12 mm des = 244 mm

Use Ylw = 12 mm del = 241 mm

Mu/(bd2)sw= 1.5*M*106/(1000*des2) 0.30 N/mm2 ρsw = 0.205 (Min) %

As reqd.(sw) =b*d*ρ/100 500.20 mm2/m Use Y 12 113

Spacing = 225.91 mm

Use Spacing 200 mm C/C

As Sup. 565.00 mm2/m OK

Mu/(bd2)lw= 1.5*M*106/(1000*del2) 0.25 N/mm2 ρlw = 0.205 (Min) %

As reqd.(lw) = b*d*ρ/100 494.05 mm2/m Use Y 12 113

Spacing = 228.72 mm

Use Spacing 200 mm C/C

As Sup. 565.00 mm2/m OK

SUMMARY

TYPE F1
SIZE 1.20 x 1.30 x 0.30
SH. WAY Y 12 @ 200 mm C/C
LONG WAY Y 12 @ 200 mm C/C

F1
ONE WAY SHEAR CHECK: At "d" distance from column face

Vu(Total Force X (l – d) X B )= 48 KN
NOMINAL SHEAR STRESS(Vu/BXd)= 0.151324086 N/MM^2
Permissible shear stress in concrete (tc) for limit state design method
Ref IS 456:2000 Table 19
fck pt tc
N/mm2 % N/mm2
25 0.205 0.33 OK