You are on page 1of 6
PT. LIANG CHI INDONESIA Cent its) Inlet Louver & Side Plate i PVC Inlet louvers and FRP side plales are ant-acié, ant-alkaline, weather-proof, anti-corrasive and resistant to Ultra-Vielet, none-twisted and non-deformed Water Sump The water am is made of FRP material and externally supported with hot-dipped-galvanized steel. The piping of water sump includes outlet water, auto files ip, quick filer pg, over-‘ow pie an dan ppe. The sainless steel sition stner installed on outlet pietotockade the aien objects from entering. The basin parttions can be. eae installed for multiple cells so that the tower can be cleaned or maintained for the individual cell or partially, without affecting the operation of the whole system. Plenum The cross flow type's heat exchanging process is applied. The direct contact between vertical air from both sides and the falling water from hot water ‘asin occurs inside the PVC lings so hat he heat can be rejetted from te towrby te fn. The access door and wahway equiped inside the ower ate t insure th convenience of maintenance and cleaning. Motor Outdoor TEFC motors are applied. Fan & Driving Unit The axial fan design is applied and can be adjusted based on actual operation of alt volume. The a ‘reducer is driven with mutti-belts to insure that thereis larger contact area, lew vibration and smooth transmission. The belts are protected with FRP casing so that they are not wetted and rot gliding, Filling PVC iilings are vacuum-ormed ard glued together on nipple ends so that there is edequate space to avoid scaling and clogging. Thus, the water can te velo nsu gout et excharg f coning oes, ah yer ong tot as ea upto reve fo eign taling of. Thebotim ar designed wih suspenced sapportrs to void éepostng varous objets and scaling so tht cooling towers canbe ease of mainenaree and cleaning Distribution System Hot water basins are installed on two sides of tower and distribution water is gravitationally falling into tower with low water pressure. This design leads. ‘the water 10 spread into the filings evenly and achieve the best efficiency of heat exchanging. FRP distribution box inside can lower the inlet water pressure ‘o prevent the water ro splshing. Float Valve Ass’y Bronze Float valve ass'y is equipped inside the water basin and adjustable for controling normal water level during operation, Water Eliminators The peat lminasvael one ffi hae Dest waren cen andar nate svete make wae by tena irift loss. K a Me ULL} FAN STAGK (ERP) MOTOR CLERC) FANGUARD HO.GS/SST) _SPEEDREDUNER GEL DAME OR GEAR ONE) FANASS'Y (AL. ALLOY / ERP) /, NLETPIPE (FR) ae AL MOMRTELSESN ERE, a he if ‘LADDER (HD.GS/S.ST) SE PLATES ERE _— AGES DOOR (ERE) WATER BASN suPPoRTORS (065/851) \__OMMLET @uDGS./8. st weve \\ ae Fete ; \\ attra CAD ATR AS FRE) Ty \\oerrownng ‘SUMP (FRP) DRAIN (S. ST) DUES STRSTR ete Uae Le Es ( x I LRC-H-80-250 DANS LRG-H300-500 o/bAe LRC-H-600 Dimensions mm (inch) drop, piping friction loss and tower head. Towel Nerina Height i ROH Loe Width Length 3) Fan Dia Fan Mo Vin mim mim mm mim mm mm HP. -80 0408) 2635 (PRA7ON 520 2850") 3670 | 4200 Px ~100 1,300 2,635, 1,670 820 2,850 3,670 1,300 3X 7125 1,625 2,835, 1,870 810 2,850 3,660 1,500 5X7 -150 1950 2835 2070 3810 2,850 3660 | 1,500 5X1 “175 Ber" 3035 |pe275) sso 2850) 3730 [roo zyx: -200 2,600 3,135, 2,475, 880 2,850. 3,730 1,800 TVX -225 2925 «3,385 | 2575 880 Beso 37350 Oo 72x: -250 Sep 3.335 fee75 | 880 2850, 3730 | 2000 10x’ -300 8900 2,885 [4075 )) sto 2850) 3660 | 1\600 8Xz -350 4,550 3,035 4,485, 880 2,850 3,730 1,700 TVXe -400 5200 3,135 [7/4885 880 Beso) 3730 | GBC 72x: 450 5,850 3,335 5,085 880 2,850 3,730 2,000 7X2 -500 Goo! 3,535 eee) «seo Beso 3730 eo tox: -600 7800 3,135 | 7,205 880 250°) 3730 [§as00N) 7%x: -700 G00 3.335 |) 7,595") 880 2850" 3730 [BG 7»x: 800 10,400, 3,135, 9,705 880 2,850 3,730 1,800 7X4 2900") /77\700" 3,335 10,1057 880 2850. 3730 [2000 7%xé 1000 13,000 3,335 «11,805 += 880 2.850 3730 | 2000 10x 1125, 14,625 3,335 12,615 880 2,850 3,730 2,000 7VeXE 1250 16,250 3,335 «14,115 880 Beso) 3730 (2000) 10x: 1. Nominal Tons are defined as 131/min/Ton, Cooled from 37°C to 32°C with 27°C wet bulb temperature. 2, Total pump head required for cooling water circulation pump is the sum of condensed water pressure T 7 rf ow ES w | Jot Jot = L = ofp LRG-H-800-1000 LRC-H-1125-1250 Pipe Connection mm Approx. Tower Inlet Outlet Drain Over Flow Auto Filter Quick Filler Dry Wt. Nita Head *2 @ -er re) (6) Wa ewe ae kg M SB(G0A)X2 | 4B(100A) | 2B(50A) | 2B(50A) | 9B(20A) —48(20A) 710 1940 a7 SB(G0A)X2 © 5B(125A) 2B(60A) 2B(50A) 1B(25A) —-1B(25A) 750 2050 37 (B(IOOA)X2) 5B(125A) | 2B(0A))) 2B(50a) [/HB(25A) —18(25A) 800 2220 an 1B(100A)X2_ 6B(150A) 2B(50A) 2B(50A) 1B(25A) 1B(25A) 850 2320 3.7 B(i25A)X2| 6B(150A) | 2B(G0A) | 28/504) [9 4B(25A) 18(25A) 970 2870 38 B(I25A)X2 8B(200A) 2B(50A) -28(50A) 1#B(32A) 1%B(92A) 1090 2830 3.8 B(F25AK2| aB(200A) [/2B(G0A) 28/60) ANBG2ANlY 11G;020) [NAAZ0 3170 3.8 B(125A)X2_ 8B(200A) 2B(50A) ‘2B(50A) 1%4B(32A) 114B(32A) 1200 3370 3.8 B(100A)K4| 8B(200A) | 2B(50A)) 2B(60A) //1KB(G2A) 1uB(G2A) | 4600 4040 3.7 B(125A)X4 6B(150A)X2 2B(S0A)X2 2B(50A)X2 1B(25A)X2_ 1B(25A)X2 1840, 5240 3.8 B(I25A)x4| 8B(200A)x2 | 2B(50A)X2 28(60A)x2 [ARAB(G2A)XA) 1B(32A)X2 [NNNBEON | 5560 3.8 B(125A)X4 8B(200A)X2 | 2B(S0A)X2 2B(50A)X2 114B(32A)X2 114B(32A)X2 | 2440 6240 38 B(i25A)X4| 8B(200A)X2 | 2B(60A)X2 26(50A)X2 [T44B(Q2A)X2 114B(32A)x2 | 2800 6640 3.8 B({25A)X6 8B(200A)X2 | 2B(60A)X2 2B(50A)X2 1%4B(32A)X2 1%B(32A)xX2 2890-7790 38 B(125A)X6 8B(200A)X3 2B(S0A)X3 2B(50A)X3_ 144B(32A)X3 1%B(32A)x3_ 3160 9310 3.8 B(125A)X8 8B(200A)X3 2B(S0A)X3_ 2B(50A)X3 114B(32A)X3. 114B(32A)X3 3820 10520 3.8 B(I25AKE 85(200A)x3 | 2B(GOA)NS 20(50A)x3 1%B(G2A)KS 118(92Ax3 4180 1180 | 88 B(I25AXB 8B(200A)X3 2B(GOA)X9 28(50A)X3. 1%B(G2A)X3 1%B(92AX3 4500 12660 3.8 B(125A)X10 8B(200A)X4 2B(S0A)X4 2B(50A)X4 114B(S2A)X4 114B(32A)X4 5200 14950, 3.8 B(I25A)X10 8B(200A)X4 2B(50A)X4 28(50A)X4 194B(92A)X4 1%B(32A)X4 5600 15950 3.8 3. Make-up water inlet pipe of 11/B(32A) is joined with outside piping connector of 1158408). 4, We reserve the right to make change in the specifications and dimensions without notice. RECOMMENDED CONCRETE FOUNDATIONS : 02.5 2105 735 3130 1002.5 2305 735.3130 1105 2510 835 33308 a 1255 = 2810 985 «= 3630 8 isos 3110) 985) ae00) |e 300 2005 «4310 735 «313012 zero 4720 835 3390 | 12 2410 5120 885 3430 12 210 | Sa 985 asso 12 | 2810 5920 985 3630 12. 00 2510 10340 985 3630 20 ‘as10 11540 985 9590 20 | 12850 985 3630 24° 2510 LRC-H4125-1250 : 4422” wre xz00.xe # Sf ats 160 [[alal 150 3 Hal LRC-H-80-300 LRG-H350-500 Che LRC-H-600-700 L-TYPE ANCHOR: WS/a x 2001 x E, BOLT GROUTING AFTER ANCHOR BOLTS ARE ta EMBEDED LRC-H-800-1000 Head Office : GRHA PRABA SAMANTA Jl. Daan Mogot Km. 12 No. 9 Jakarta 11730 Telp : 021 6193099, 6193212 6196349, 6196962, ee Fax-* 0246196341 ge. lonesia @oa Ip : 031-8432636, 8497868 91-8497438, 8497433 Ici@sby.oas.co.id ‘Bandung: _ Telp : 022-6124001, 6124002 Fax : 022-6124001, 6124002

You might also like