Elisys Uno

Fully Automated ELISA Analyzer


> Excellent entry into ELISA automation
> Optimized and adaptable to your needs
> For all kinds of laboratories

ELISA
CoreLab DX

ELISA System Line

Diagnostics Worldwide
Elisys Uno
1-plate Fully Automated ELISA Analyzer
for all Kinds of Laboratories

> Preprogrammed for all available HUMAN and IMTEC tests


> Ideal automation at an affordable price
> Excellent cost/performance ratio
> Unique one plate automation concept
> Processing of one microplate

Flexible operation Convenient & efficient use


> Rapid setup and minimal maintenance > Use of original kit components
> Capacity: 96 samples > Testing of up to 8 parameters simultaneously*
> Different racks for all kinds of reagents > Capacity level sensing of reagents and samples
> Real walk-away thanks to high loading capacity > Automatic sample predilution
> Four filters installed: 405, 450, 492, 630 nm (IAD filter) > Self-monitoring mechanics and optics
> Two syringe pumps: 2.5 ml and 50 μl
> Optimised for volume ranges from 5 μl – 1.95 ml

* depending on the depending on the kind of procedure of the ELISA kits applied
> 2 wash buffers
> All bottles integrated
> Small footprint

Elisys Uno REF 17350

Easy-to-use software
> Graphical interface > Assay programming simplified
> Bidirectional host communication > Sample and reagent positions can be changed
> Event log documentation using the Windows® “drag and drop” feature

> Report generator; printout format according to user needs > Self-explanatory software structure

> Password protection > Multi tasking

> Win 7 compatible

Advanced
QC module
(Levey-Jennings)

Time-management system:
Real-time-mode display
Optimised scheduling for combined tests
Elisys Uno
Technical Data

Reagent and sample dispensing Software


Capabilities predilution, dispensing of single Format USB card
or multiple reagents Operating systems Windows 7
Pumps two syringe pumps 2.5ml and 50μl Minimum system USB port
Pipetting Stainless steel probe, level sensing Secondary menu options create/edit protocols,
Min. & max. volume 5μl – 1.95ml import/export data,
Max. no. of specimens 96 (including calibrators and controls) control, run, setup
Max. no. of reagents dependent on rack combination, reagents Calculation modes absorbance, cut-off, cut-off standard,
can also be placed into the sample rack point to point, linear regression,
Reaction vessel standard microplate wells cubic spline, dose response,
Instrument bottles 1l priming bottle, 1l system liquid, polynomial 2nd – 4th order,
2l wash bottle with low volume warning % – absorbance, log-logit, 4 PL
sensor. Self-monitoring modes lamp, bottle volume, filters,
1l rinse bottle (or 2nd wash) with low pressure, vacuum, mechanical
volume warning sensor, waste bottle function and more
include alarm when incubation QC options store control data, print Levey-
was out of range Jennings or QC range plots,
calculate SDs

Incubation, timing and temperature control Power


Thermal control plate/well 25°C, 37°C, Voltage range 100 – 250VAC
or ambient temperature, temperature Frequency range 50 – 60Hz
controlled to 25°C providing the ambient Power maximum 160W online UPS recommended
room temperature is below 25 °C, sample Installation category CAT II
rack is not temperature controlled

Washing Environmental conditions for safe operation


Wash head 8-needles, automatic prime and rinse Mains supply voltage fluctuations not to exceed ±10% of
Programs user-programmable protocols the nominal voltage
(aspirate, dispense, soak) Humidity 80 % for temperatures up to 31°C
decreasing linearly to 50% humidity
Reading at 40°C
Optical design absorbance reading in 4 simultaneous Operating temperature 18 – 35°C recommended
channels; NIST-traceable calibration; Operating humidity Less than 85 % recommended
monochromatic or bichromatic results Dimensions (incl. PC) 170 cm (W) x 80cm (D) x 80cm (H)
Light source Tungsten-Xenon lamp approx. weight = 35kg + PC
8 position filter wheel 4 filters: 405, 450, 492, 630 installed
Interference filters long life, hard coated, ion-assisted
deposition, ±2 nm, 10nm,
981230/2018-01 © 2018 Human

typical half bandpass


Linear range – 0.2 to 3.0A
Photometric accuracy ±1 % of the reading +0.005 A from 0 to 1.5 A
±2% of the reading +0.005A from 1.5 to 3.0A