Features
• Protects against downtime, data loss and process interruption by
providing continuous, clean power
• Offers premium performance with a 0.9 power factor and >95
percent efficiency in high efficiency mode
• Increases battery service life and system uptime with ABM®
battery charging technology
• Enables prolonged runtime of essential equipment during power
outages by allowing for orderly, remote shutdown of non-critical
systems or processes
• Provides installation flexibility with a choice of rack or tower
designs, both conserving valuable space
Product snapshot
• Ensures data and system integrity with LanSafe® power
management software
Product rating: 700 to 3000 VA
• Provides a two-year limited warranty, an extended warranty,
Voltage 120 Vac, 208–240V
on-site Flex™ and on-site PowerTrust™ service contracts, and a
Frequency: 50/60 Hz $250,000 load protection guarantee (US and Canada)
(auto-sensing)
Configuration: Rackmount or tower
The Eaton® 9130 UPS, resolves Double-conversion
utility power problems and deliv-
ers superior power protection for design for superior
IT and networking equipment, power protection
Advanced power protection for: medical systems, manufacturing
process control—or anywhere The 9130 is constantly monitor-
• IT and networking environments critical equipment and applica- ing power conditions—regulating
tions require clean, continuous both voltage and frequency.
• Servers, networking gear Even when presented with the
power.
• Telecommunications, VoIP, security systems most severe power problems,
Every organization is concerned this UPS’s output remains
• Medical systems about being “green,” saving within three percent of nominal
• Diagnostics and medical screening energy, cutting costs. The 9130 voltage.
• Patient record archives makes the best use of every
utility dollar. It runs efficiently, With a wide input voltage range,
• Manufacturing systems dissipates less heat and saves the 9130 does not depend on
thousands of dollars a year in batteries to smooth out minor
• Chip fabrication power fluctuations. Batteries are
power and cooling.
• Pharmaceutical production conserved for those times when
utility power is highly unstable
• Chemical processing
or completely out. If an outage
occurs, the 9130 transfers to
battery with zero interruption
in power, making this an ideal
UPS for sensitive and critical
equipment.
More real power for Advanced design and Stronger, longer battery External battery
less cost self-monitoring for life with exclusive ABM modules for extended
More real power. High 0.9 premium availability technology runtime
output power factor enables The 9130 continually monitors Most UPS manufacturers on the During a power outage, internal
the 9130 to provide its full voltage, temperature, internal market today employ a constant batteries in the 9130 keep loads
power capability to modern element functions, battery ‘trickle-charging’ system, which running long enough to grace-
IT equipment that may have a health, battery state-of-charge can ultimately reduce potential fully shut down systems. Add
wide range of leading and lag- and runtime remaining. If the battery service life by as much more runtime at any time, with
ging power factors. With a 0.99 UPS detects a potential problem as 50 percent. In contrast, ABM up to four external battery mod-
input power factor, this UPS with any of these measures, it technology uses sophisticated ules to run systems for hours if
avoids the disturbances that sends alarms or takes corrective sensing circuitry and an innova- necessary. These battery mod-
some energy converters tend to action, with no interruption in tive three-stage charging tech- ules are hot-swappable and can
cause. power. At the end of an alarm nique that significantly extends be replaced at any time without
High efficiency. The more effi- condition, the 9130 automatically UPS batteries’ useful service life powering down the UPS or pro-
cient the UPS, the lower your reverts from bypass to normal while optimizing their recharge tected loads. You can also start
utility and cooling bills. Even a operation. time. up the UPS and power its loads
small increase in efficiency can The 9130 provides up to 60 with battery power.
quickly translate into thousands days’ notice of the end of use-
of dollars. When power condi- ful battery service life. You have
tions are within acceptable ample time to hot-swap batter-
limits, the 9130 can operate in ies without ever having to shut
a remarkable high-efficiency down connected equipment.
mode: 95 percent efficient or
higher.
Battery runtimes
Note:
Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
Runtimes are shown at a 0.7 power factor.
PW9130i700T PW9130L2000T-XL
700/490 8 N/A N/A N/A N/A 2000/1400 15 61 111 156 194
525/368 12 N/A N/A N/A N/A 1500/1050 21 81 145 184 269
350/245 19 N/A N/A N/A N/A 1000/700 34 129 198 293 410
175/123 35 N/A N/A N/A N/A 500/350 72 225 449 590 766
Note:
Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
Runtimes are shown at a 0.7 power factor.
www.eaton.com/powerquality 1.800.356.5794 3
Maximum battery run- Intuitive, visual UPS
time for critical systems monitoring and
Using LanSafe power manage- management
ment software, you can indepen- Local. An on-site user can con-
dently control load segments, figure and monitor many fea-
which are groups of receptacles tures of the 9130 using a large,
on the rear panel of the UPS. bright, backlit display with easy
This feature enables you to man- navigation—available in mul-
age scheduled shutdowns and tiple languages. LEDs provide
sequential startups of protected at-a-glance insight into system
loads. During a power outage, status.
you could shut down power
to non-critical devices, thereby Remote. The 9130 comes com-
extending battery backup time plete with the LanSafe suite of
available for critical devices. power management software
You can also use this feature that provides control and vis-
to remotely re-boot locked-up ibility over all your UPS systems,
equipment. using an intuitive, graphical inter-
face and SNMP.
Flexible deployment and From a central vantage point,
you have the visibility and con- LanSafe answers network administrators’ key
communication options trol you need to ensure continu-
One platform, two form fac- ous up-time. For example, you questions with an intuitive visual display.
tors, dozens of choices. Up to can establish a prioritized shut- Is input voltage within the acceptable range?
3000 VA of UPS power is packed down of network devices and
into only 2U of rack space. The client/server applications, test all If the power went out, how long could the UPS run on battery power?
tower option is about the size of networked UPS systems from
a modern, compact PC, occupy- one node, analyze trends and Is the UPS running on battery power right now?
ing only 1.5 square feet or less network conditions, and stay
of footprint. Choose from doz- informed of power problems by Are there any active events I need to know about?
ens of models offering the input pager and e-mail.
plug type and output receptacles Is the UPS online or in bypass mode?
The LanSafe software package
that suit your needs and voltage. also includes multimedia demon- Is output voltage within acceptable limits?
Monitor and manage the UPS strations and a free trial for you
from anywhere. Connectivity to explore optional software for What percent of UPS capacity is being used right now?
options are available for almost UPS performance monitoring/
any networking environment. analysis and facility/data-center Is the battery being charged or discharged?
The standard unit comes with management.
USB and RS-232 serial com-
munication ports. You can Enhance your UPS with
customize your UPS by adding
BestDock interface options for complementary options • Power distribution units Eaton, your trusted ally
other types of communications, streamline the distribution
such as to:
Count on Eaton for comprehen-
of power throughout a data for power quality
sive power quality and infrastruc-
ture solutions. You can comple- center, rack or enclosure. Representing more than 40
• Control and monitor UPS
status and meters via SNMP ment your 9130 with options • Monitoring systems, such years of R&D excellence, the
or a Web browser that create a more effective, as LanSafe, give you the new 9130 delivers more real
manageable and resilient data insight to effectively man- power—so you can power
• Monitor and shut down center or facility. For example: age the facility and its power through any disruption and
multiple servers with different infrastructure for maximum keep your organization’s critical
operating systems • A maintenance bypass systems protected reliably and
enables power to completely uptime.
• Send relay-contact alarm efficiently. Eaton will be there
bypass the UPS, so it can be • Support services, such as with you for the long term with
notifications to remote safely serviced or replaced our eNotify remote monitor-
security systems premium warranty coverage and
without powering down ing, ensure that your power expert technical support.
critical systems. infrastructure is intelligently
designed, continuously When you want maximum
• Rugged and attractive enclo- peace of mind, count on
sures provide well-organized monitored and managed for
always-on operations. Eaton’s eNotify Remote
rack space for data centers, Monitoring service. With this
wiring closets, office environ- 7x24 service, our Customer
ments and warehouses. Reliability Center (CRC) remotely
monitors your UPS and contacts
you in case of an emergency.
To find out more about the 9130
and other Eaton power quality
solutions, visit our Web site at
www.powerware.com/9130 or
contact us at 1.800.356.5794.
Choose from various back panel configurations in either rack or tower models—
all offer load segmentation.
Tower models
1 5
Input cord length is 6 ft This EBM works with 700/1000 VA models, Additional notes:
2
Rack models occupy 2U of rack space where available When high voltage 9130 is used at 208V,
6
and fit into 19-inch racks This EBM works with 1500 VA model derate power by 10%, and 20% at 200V
3 7
C14, w/detachable L6-20P This EBM works with 2000/2500/3000 VA
4
C20, w/detachable L6-20P models, where available When low voltage 9130 is used at 110V,
derate power by 10%, and 20% at 100V
www.eaton.com/powerquality 1.800.356.5794 5
Technical specifications 1
General Communications
User interface Graphical LCD with blue backlight and text in Serial port RS-232 standard, for interface to power
English, French, German, Russian and Spanish management software
LEDs Four status-indicating LEDs USB port HID standard, for communicating with Windows 98,
Topology True online, double-conversion XP, ME and Vista computers
Diagnostics Full system self-test Relay output Common alarm standard
UPS bypass Automatic bypass Communications Optional communication slots (BD Slot)
slot
Dimensions See models table
Optional SNMP/Web card for direct control and monitoring
Rail kit 4-post rail kit included with all rackmount units communication in SNMP-based networks, monitoring of UPS status
EBMs Ship with a rail kit cards and meters through Web browser interface Relay
Remote Emergency shutdown control through the REPO port card for integration to industrial environment and
Emergency building management systems, remote shutdown
Power-off (REPO) for IBM AS/400 systems
Battery
Battery type VRLA 12V/9 Ah (both internal and external)
Battery runtime >3 minutes with internal batteries @100% load
Battery Hot-swappable internal and external batteries
replacement
Start-on-battery Allows start of UPS without utility input