You are on page 1of 9

C-FIX 1.84.0.

0
Database version
2019.9.20.11.13
Date
05/02/2020

fischer FZE

Jebel Ali Free Zone Warehouse No XB


P.O. Box 261738 Dubai

Enquiry@fischer.ae
www.fischer.ae

Comment
WORST CASE 1

Design Specifications
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 16/50 A4, stainless steel,
property class A4
Calculated anchorage 85 mm
depth
Design Data Specification by manufacturer

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including

partial safety factor for the load) Static

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.84.0.0
Database version
2019.9.20.11.13
Date
05/02/2020

Input data

Design method TR055/Design method ENSO Mechanical


Base material Normal weight concrete, C40/50, EN 206
Concrete condition Cracked, dry hole
Reinforcement No or standard reinforcement. No edge reinforcement.
Without reinforcement against splitting
Drilling method hammer drilling
Installation type Push-through installation
Annular gap Annular gap not filled
Type of loading Static or quasi-static
Base plate location Base plate with non bearing layer, e.g. grout pad, g = 15 mm
calc. lever arm l = 31 mm
Degree of restraint αM = 1.0
Mortar compression strength: 30.0 N/mm²
Base plate geometry 300 mm x 200 mm x 16 mm
Profile type Customized profile

Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 8.68 0.00 -6.70 4.28 0.00 0.00 Static or quasi-static

*⁾ The required partial safety factors for actions are included

Resulting anchor forces


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. kN kN kN kN
1 13.00 1.68 0.00 -1.68
2 13.00 1.68 0.00 -1.68
3 5.18 1.68 0.00 -1.68
4 5.18 1.68 0.00 -1.68

max. concrete compressive strain : 0.12 ‰


max. concrete compressive stress : 4.4 N/mm²
Resulting tensile actions : 36.37 kN , X/Y position ( 0 / 52 )
Resulting compression actions : 27.69 kN , X/Y position ( 0 / -86 )

Resistance to tension loads

Action Capacity Utilisation βN


Proof kN kN %
Steel failure * 13.00 47.07 27.6
Concrete cone failure 36.37 50.69 71.8
Splitting failure 36.37 40.82 89.1

* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2
C-FIX 1.84.0.0
Database version
2019.9.20.11.13
Date
05/02/2020

Steel failure

( NRd,s )

NRk,s γMs NRd,s NSd βN,s


kN kN kN %
70.60 1.50 47.07 13.00 27.6

βN,s
Anchor no. % Group N° Decisive Beta
1 27.6 1 βN,s;1
2 27.6 2 βN,s;2
3 11.0 3 βN,s;3
4 11.0 4 βN,s;4

Concrete cone failure

( NRd,c )

Eq. (5.2)

Eq. (5.2a)

Eq. (5.2c)

Eq. (5.2d)

Eq. (5.2e)

NRk,c γMc NRd,c NSd βN,c


kN kN kN %
76.03 1.50 50.69 36.37 71.8

βN,c
Anchor no. % Group N° Decisive Beta
1, 2, 3, 4 71.8 1 βN,c;1

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3
C-FIX 1.84.0.0
Database version
2019.9.20.11.13
Date
05/02/2020

Splitting failure due to loading

( NRd,sp )

Eq. (5.3)

Eq. (5.2a)

Eq. (5.2c)

Eq. (5.2d)

Eq. (5.2e)

Eq. (5.3a)

NRk,sp γMsp NRd,sp NSd βN,sp


kN kN kN %
61.24 1.50 40.82 36.37 89.1

βN,sp
Anchor no. % Group N° Decisive Beta
1, 2, 3, 4 89.1 1 βN,sp;1

Resistance to shear loads

Proof Action Capacity Utilisation βV


kN kN %
Steel failure with lever arm * 1.68 4.78 35.0
Concrete pry-out failure 6.70 172.58 3.9
Concrete edge failure 6.70 28.69 23.3

* Most unfavourable anchor

Steel failure with lever arm

( VRd,s )

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4
C-FIX 1.84.0.0
Database version
2019.9.20.11.13
Date
05/02/2020

Eq. (5.5/a)

VRk,s γMs VRd,s VSd βVs


kN kN kN %
5.98 1.25 4.78 1.68 35.0

βVs
Anchor no. % Group N° Decisive Beta
1 35.0 1 βVs;1
2 35.0 2 βVs;2
3 28.5 3 βVs;3
4 28.5 4 βVs;4

Concrete pry-out failure

( VRd,cp )

Eq. (5.6)

Eq. (5.2)

Eq. (5.2a)

Eq. (5.2c)

Eq. (5.2d)

Eq. (5.2e)

VRk,cp γMc VRd,cp VSd βV,cp


kN kN kN %
258.88 1.50 172.58 6.70 3.9

βV,cp
Anchor no. % Group N° Decisive Beta
1, 2, 3, 4 3.9 1 βV,cp;1

Concrete edge failure

( VRd,c )

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5
C-FIX 1.84.0.0
Database version
2019.9.20.11.13
Date
05/02/2020

Eq. (5.7)

Eq. (5.7a)

Eq. (5.7b/c)

Eq. (5.7e)

Eq. (5.7f)

Eq. (5.7g)

Eq. (5.7h)

VRk,c γMc VRd,c VSd βV,c


kN kN kN %
43.04 1.50 28.69 6.70 23.3

βV,c
Anchor no. % Group N° Decisive Beta
1, 2 16.7 1 βV,c;1
3, 4 23.3 2 βV,c;2

Utilization of tension and shear loads

Tension loads Utilisation βN Shear Loads Utilisation βV


% %
Steel failure * 27.6 Steel failure with lever arm * 35.0
Concrete cone failure 71.8 Concrete pry-out failure 3.9
Splitting failure 89.1 Concrete edge failure 23.3

* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 6
C-FIX 1.84.0.0
Database version
2019.9.20.11.13
Date
05/02/2020

Resistance to combined tensile and shear loads


Utilisation steel
Eq. (5.8a)

Eq. (5.8b)

Eq. (5.9)

Utilisation concrete Proof successful


Eq. (5.8a)

Eq. (5.8b)

Eq. (5.8c)

Base plate thickness


Stress distribution pattern within the Base plate details
anchor plate
Anchor plate thickness t = 16 mm
Base plate material S 275
E-modulus E = 210,000 N/mm²
Yield strength Rp,0,2 = 275 N/mm²
Safety factor γM = 1.1
Poisson's ratio ν = 0.3
Utilisation η = 94 %

Profile type Customized profile

Technical remarks
All data and information in the software is based on fischer products and common engineering knowledge. Please
check all the proof results against local valid standards and approvals.
As fischer is not the design office, the attached is no guarantee for incorrect input or assumptions. Any
recommendations have to be approved by the building-authority or project engineer. Results are valid only for
anchor system calculated in the attached. If any part of the system is changed, it will invalidate this report and new
calculations would be required.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate must be
sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about
the stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 7
C-FIX 1.84.0.0
Database version
2019.9.20.11.13
Date
05/02/2020

Installation data
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 16/50 A4, Art.-No. 501424
stainless steel, property class A4

Accessories Blow-out pump ABG big Art.-No. 89300


SDS Plus II 16/150/210 Art.-No. 531827
or alternatively
FHD 16/250/380 Art.-No. 546599
Hammer drilling with or without
suction

Installation details
Thread diameter M 16
Drill hole diameter d0 = 16 mm
Drill hole depth h2 = 139 mm
Calculated anchorage hef = 85 mm
depth
Installation depth hnom = 103 mm
Drilling method hammer drilling
Drill hole cleaning only blow out by hand
No borehole cleaning required in
case of using a hollow drill bit, e.g.
fischer FHD.
Installation type Push-through installation
Annular gap Annular gap not filled
Installation torque Tinst = 110.0 Nm
Socket size 24 mm
Base plate thickness t = 16 mm
Grout thickness g ≤ 15 mm
Total fixing thickness tfix ≤ 31 mm
Tfix,max tfix, max = 50 mm

Base plate details


Base plate material S 275
Base plate thickness t = 16 mm
Clearance hole in base df=18 mm
plate

Attachment
Profile type Customized profile

Profile dimensions mm
Height 200
Width 75
Flange thickness 3

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 8
C-FIX 1.84.0.0
Database version
2019.9.20.11.13
Date
05/02/2020

Anchor coordinates

x y
Anchor no. mm mm
1 -120 75
2 120 75
3 -120 -5
4 120 -5

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 9

You might also like