Hakko T12 Controller Setup instructions

Numerical editing mode: Left and right rotation encoder to change the current bit value, short
press encoder to move to the next edit bit (that is, the decimal point indicated position), long press
the encoder to determine the input

Yes or no: input 0 is NO, input 1 is YES.

When Constant heating, press the encoder into setting the common parameters of the editor
P10 Encoder temperature Stepping (1-100) is to rotate the encoder temperature changing value
(default 5)

P11 temperature Calibration, enter P11 display 000. Input 0 means discarding modify, input 1, short
Press Shows default 270, gain and edit thermocouple amplifier. The difference between the actual
temperature and the setting temperature can be calibrated according to the 191 measurement
tools. The temperature display value is greater than the actual measurement value, decreases; the
value conversely increases the value. (this maximum parameter is 999. Should not be greater than
350 in order to avoid temperature runaway and burn iron core).

NOTE: The debugging is the best condition, please don’t change easily.

Press encoder into setting parameter:

P01 ADC Reference voltage (obtained by measuring TL431), is the actual measured voltage MV
(unit divided by 10)

P02 NTC correction, display at the current room temperature for 3 seconds, after showing
P02( choose YES or NO) choose No (Exit settings), choose to enter the new correction value after
the repeat setup process.

P03 op-put input offset voltage correction value, display current ADC value for 3 seconds, after
displaying P03( choose YES or NO)choose No (Exit settings), choose to enter the new correction
value after the repeat setup process (need to T12 to maintain room temperature).

P04 thermocouple Amplifier Gain

P05 PID parameter Pgain

P06 PID parameter Igain

P07 PID parameter Dgain

P08 Automatic shutdown Time setting (3-50 mins)


P99 restores default settings, chooses YES means to restore, and chooses NO means to discard.
Current default parameters
ADC Reference voltage 2490
NTC Correction Value 32
Automatic Shutdown time 10
Op-Drop input offset voltage correction value 55
Thermocouple Amplifier Gain 270
Pgain 64
Igain 2
Dgain 16