You are on page 1of 4

Jadestone Gas Metering Specification

S.NO

1 AVL

2 Area Classification
3 Certification
4 Weather Proof
5 Metering Panel Location
Uncertainity in terms of
6
metering
7 Turn Down Range
8 Repeatability
9 Flow Meter Type
10 No of metering streams
11 Manual Sampling
12 C9+ Gas chromatography
13 Moisture Analyzer

14 Mirror Gas Dewpoint


Analyzer

15 Diagnostics

16 Approval

17 Isolation

18 Controlled Pressurisation
19 Vent & Drain Valves
20 Communication Protocol
21 PT Uncertainity
22 PT Repeatability
23 PT Indication
24 PG Accuracy
25 PT Installation Standard
26 Temperature Inst. Type
27 TT Uncertainity
28 Test Thermowell
29 WFC
30 Sun Shade
31 TT Indication
32 TG Accuracy
33 TD Dial Size
34 Sample Probe Location
35 Gas Chromatograph type
36 Make
37
g Specification

Approved Packaged Equipment and Manufactured Components List (JSEV00-GEN-FPSO-D-PUR-LST-0002)


Zone 2, Gas Group IIA, T3
ATEX/Cenelec agency
IP 56 per IEC 529
unclassified air conditioned building
<1.0% of energy, mass, & Volume

10:1
+/-0.2%
Minimum 4 or 5 path Ultrasonic Gas Flowmeter
2
1L Manual Sampling
2Nos, at inlet
1Nos,
A single chilled mirror gas dewpoint analyser

• Velocity of sound checks;


• Chord velocity checks;
• Chord gain checks;
• Chord ratio checks; and
• Efficiency checks.
Quatest-3
Inlet and Outlet DBB, shall be electrically actuated with Locally operated Upstream & remotely operated
Downstream valves
globe valve across one of the 2 main inlet valves
DBB locked Close
Smart type HART
0.15% of calibration span.
+/-0.1%
Local digital reading
0.5%
ISO2186
PT100 RTD
0.15oC of calibration span.
Required
Required
Required
Local digital reading
0.5 DegC
125MM
Upstream Common point
Emerson Danalyzer 500, ABB Vista.

You might also like