You are on page 1of 5

3/4/2020 Corrosion and Protection of Transmission Steel Structure Tower - Communication tower,Lattice tower,Self-support tower manufacture…

 86-0318-7973636  steeltowerchn@163.com

HOME ABOUT US PRODUCTS EQUIPMENTS NEWS TECHNICAL V

Corrosion and Protection of Transmission Steel


Structure Tower

PRODUCTS
 
HOME

Corrosion and Protection of Transmission ABOUT US

Steel Structure Tower PRODUCTS

Tags  Categories  EQUIPMENTS

NEWS

2
TECHNICAL

VIDEO

0
CONTACT US

0
LAST UPDATE PRO

Single
Circuit
Angle Steel 0
Power
Transmission
Line Tower

 March
Abstract: With the continuous improvement of social and economic development level, China’s power grid construction 22, 2019
has also been continuously developed and advanced. Transmission towers are an important part of current power grid
construction work, and they play a role in the power transmission process. It plays an important role. However, the Camou aged
transmission tower is mainly located in the external environment and is easily affected by environmental pollution such as Palm Tree
rain and the atmosphere. Corrosion may easily occur. This will not only affect the service life of the tower, but also threaten Antenna 0
to collapse, affecting the electrical energy. Normal and effective transmission. Based on this, this paper analyzes the Telecom
corrosion characteristics, causes, and protection issues of the current transmission tower, and proposes an effective WIFI Tower
strategy to strengthen the protection of the transmission tower.  March
20, 2019
 

3 legged
Introduction: In recent years, with the continuous improvement of the development level of the power industry, the
lattice mast
construction of power grids has also become more and more complete. The most important part is the link of transmission triangular 0
towers, which plays an important role in the reliability and safety of power transmission. The anti-corrosion treatment radio
should be strengthened in the process of manufacturing the tower, but the current environmental pollution is becoming telecom
more and more serious, and the corrosion intensity of the transmission tower is also continuously strengthened, not only Privacy - Terms

www.steeltowerchn.com/technical-specifications/steel-tower-corrosion-protection/corrosion-and-protection-of-transmission-steel-structure-tower/ 1/5
3/4/2020 Corrosion and Protection of Transmission Steel Structure Tower - Communication tower,Lattice tower,Self-support tower manufacture…
shortening the overall service life of the transmission tower, but also increasing the transmission tower The frequency of communication
protection. Therefore, more and more anticorrosive materials are used in the new era. The quality control and tower
management are strengthened during the coating process, and the protection work quality of transmission towers is  March
continuously improved, so as to ensure the stability of the grid transmission and promote the long-term effectiveness of the 18, 2019
power industry. development of.
Telecom
WIFI GSM
Microwave 0
60m
Triangular
Lattice
Tower

 March
15, 2019

1. Characteristics and Causes of Corrosion of Transmission Towers

SEARCH PRODUCT
(A) Basic Characteristics of Tower Corrosion

Enter your search

Because the geographical environment and construction period of the tower are different, there are obvious features
in the phenomenon of corrosion of the tower, such as: In those areas where the environment is relatively poor, the
corrosion phenomenon in the towers is more serious, and if the protection measures adopted are more perfect, it may
reduce the degree of corrosion of the tower. Transmission towers are mainly composed of oblique materials, main TAGS
materials, and auxiliary materials. There are great differences in the specifications and materials of raw materials. Under
132kv 160' 230kV
normal circumstances, the probability of corrosion of the main materials is relatively low, and the corrosion phenomenon
occurs in the plate. , diagonal materials and auxiliary materials [1]. At the same time, the corrosion structure of the iron 33kv 35kv 380kv
tower also has certain characteristics. The corrosion position of the iron tower is usually prone to occur at the corners of
4 Legged Angular Telecommunic
some auxiliary materials and oblique materials. The main reason is that the materials at the corners are affected by the
stress, so they are easy to produce. Crack phenomenon. And the corners are also very vulnerable to fluids, especially in 4 Legged Tubular Communicatio
the rainy days, it is easy to accumulate some moisture, so that the raw materials have redox phenomenon. In addition, the
400KV
corrosion phenomenon often occurs in the nails and bolts of the tower. The main cause of this corrosion phenomenon is
that the corresponding anti-corrosion measures have not been taken. 500 KV lattice angel tower

(B) Causes of Corrosion in Transmission Towers

The corrosion of power transmission towers is mainly affected by climatic factors. For example, alkaline gases and
acid gases present in the atmosphere, especially in some humid climate areas, the tower is prone to corrosion. Therefore, 
in order to prevent the corrosion of the tower, the electric power company staff usually adopts a series of anti-corrosion
measures, such as the anti-corrosion paint brushing the surface of the tower material. However, in the actual anti-
Privacy - Terms
corrosion work, the coating work of the anti-corrosion layer often appears irregular and unreasonable phenomenon, so that

www.steeltowerchn.com/technical-specifications/steel-tower-corrosion-protection/corrosion-and-protection-of-transmission-steel-structure-tower/ 2/5
3/4/2020 Corrosion and Protection of Transmission Steel Structure Tower - Communication tower,Lattice tower,Self-support tower manufacture…
the anti-corrosion layer has a lot of defects, does not play a good protective effect, resulting in corrosion [2 ]. In addition, in
the specific coating, the company did not uniformly regulate the coating thickness and other related standards, so that the
coating thickness is not very uniform. If the coating thickness is too large, cracking will occur, otherwise the anti-corrosion
effect will not be obtained. Therefore, if the quality control and management of painting work are not enhanced in time,
there will be many defects in the coating, which will affect the overall anti-corrosion effect and reduce the overall service
life of the tower.

2. the main problems of transmission tower in the protection work

Compared with the old tower which has been built and used for a long time, it is necessary to remove the original coating
in the protection work, and then use the cold spraying zinc for anti-corrosion treatment.

 When the galvanized layer of the iron tower is damaged, brushing the zinc spray can effectively prevent the destruction of
the rust situation, this shows that the steel tower members in the protection of the work of zinc plating has a unique
advantages of protection. Because this kind of coating method not only the construction is simple, moreover the cost
input is also relatively low, therefore is regarded as the tower anticorrosion protection work one of important means.

 However, this method also has some problems in the protection, such as zinc layer has a relatively weak surface, so many
coatings can not be effectively attached to the zinc layer, thus reducing the overall protective effect of the coating. At the
same time, the paint repair frequency is relatively large, almost every two or three years need to carry out a painting. And in
the coating before painting also need to carry out the relevant oil removal, derusting work, in the actual work if the rust can
not be thoroughly treated clean, then the tower will soon again appear corrosion, which greatly weakened the effectiveness
of the protection work. Therefore, we should strengthen the study of reducing the rust removal process, streamline the
coating process, and continuously improve the quality and effectiveness of the tower protection.

Iii. effective strategies for strengthening the protection of transmission towers

(a) Protection of new towers Because the tower is mainly in the external environment, often faced with a variety of natural
environment, the degree of corrosion and its causes are also different. Therefore, in the protection of the tower, we need to
combine the local environmental characteristics to take targeted protection measures. In the relatively poor pollution of
the mainland, the air humidity is small, salt concentration is also low, so the zinc layer of the Iron Tower corrosion degree is
also relatively mild, hot dip galvanized can play a good protective effect, so you can through the hot Dip galvanizing
method to protect the inland area of the new tower. and relative to the coast, it is not only a large humidity, but also very
high salt concentration, because of its harsh natural environment, make the tower is prone to the overall corrosion
phenomenon, in response to this situation can be used in hot-dip galvanized anti-corrosion coating coating, to achieve the
double protection of the tower to enhance the protective effect [3].

In addition, in the actual painting should pay attention to quality control, strengthen the hot-dip galvanizing layer and anti-
corrosion coating between the two forces, so as to continuously extend the overall service life of transmission towers.
 
(ii) Corrosion protection of the Iron Tower At present, we often see the corrosion of the Iron tower, so it should be the focus
of protection work. Relevant staff should be in the area of the corrosion of the tower to investigate, timely understanding
of those who have corroded the basic situation of the tower, in the grasp of the tower’s environmental characteristics and
corrosion, corrosion reasons, and so on, based on targeted protection methods, anti-corrosion coating of the painting
work. For example, Acrylate topcoat itself has a good anti-corrosion performance, with alkali, water and acid and other
advantages, can be the general tower protection. In the less polluting areas of the interior, the tower should be protected
by a coat of primer and a layer of acrylic paint, ensuring that both the topcoat and the primer are in two ways. In the
environment is more bad or more polluting coastal areas, should be combined with the actual corrosion of the tower to
take the most appropriate protection measures, the maximum lifting anti-corrosion materials salt resistance, water
resistance and acid resistance [4]. Fluorocarbon resin materials, such as not only has heat-resistant characteristics, but 
also has strong stability, can protect the tower from other kinds of chemical substances corrosion, but this material needs
high-temperature curing to use, so the relatively high cost, resulting in relatively few applications. Acrylate also has a good
Privacy - Terms

www.steeltowerchn.com/technical-specifications/steel-tower-corrosion-protection/corrosion-and-protection-of-transmission-steel-structure-tower/ 3/5
3/4/2020 Corrosion and Protection of Transmission Steel Structure Tower - Communication tower,Lattice tower,Self-support tower manufacture…
salt resistance and acid resistance, can meet the needs of the tower protection work.
Therefore, in the coastal area of the tower protection work, can be a certain characteristics of the primer and acrylate
topcoat Organic combination method, and can be appropriate to increase the epoxy paint coating, and further enhance the
protection of the tower.

 Conclusion: In a word, with the continuous development of power grid construction, the corrosion of transmission towers
is more and more common and serious, so enterprises should attach great importance to the protection of the tower,
correct understanding of regional environmental characteristics and the extent and causes of the corrosion of the tower,
take new paint and new technology for the tower protection

At the same time, according to the characteristics of the new tower and the corrosion of the Iron tower, to take targeted
protection work, as far as possible to enhance the anti-corrosion capacity, to extend the overall life of the tower, thus
promoting the long-term effective development of electric power.

 
Reference documents:

[1] Yazanu, Li Xingeng, Shi Bin, Guo Kai. Total life cycle cost of transmission tower corrosion Protection [J].
China power, 2015,02:150-155. [2] Chen, Zhangjianqui, Huang Weilin, chat, handsome XI. Local corrosion failure analysis
and protection of galvanized iron tower in transmission line [J].
China power, 2015,05:139-143. [3] Dr. Yu.
Experimental study on Phosphating and nano-modi ed anticorrosive coatings of corroded transmission towers [D]. Ncepu,
2012. [4] Chen Yao, Anzhen. Corrosion analysis of transmission towers and protection design of organic coatings [J].
Modern paint and painting, 2010,10:23-27.

Keywords: transmission tower; corrosion problem; protection research

admin

Leave a Reply
Your email address will not be published. Required elds are marked *

Comment

Name * Email * Website

Post Comment

LANGUAGE ABOUT KEHANG PRODUCTS NEWS PRO KeHang Company


Hengshui Kehang Metal Communication Tower
Video
Single
Structure Co., Ltd-a collection Circuit
of scienti c research, Camou aged Tower Angle 0 structural st…
st…
Steel tower production and Steel
Kehang Structural & Steel Monitoring Tower
installation, communication Power
Products has the capabilities,
lines construction, Transmission

capacity and experience to Chimney Tower 
Line 00:00 03:19
manufacture and deliver the professional maintenance of
Tower
communication tower sites Self-Supporting Towers
Transmission &
Communication structures (main equipment, secondary Privacy - Terms
Street Lighting Pole

www.steeltowerchn.com/technical-specifications/steel-tower-corrosion-protection/corrosion-and-protection-of-transmission-steel-structure-tower/ 4/5
3/4/2020 Corrosion and Protection of Transmission Steel Structure Tower - Communication tower,Lattice tower,Self-support tower manufacture…
and related products you equipments, and other Electric Transmission Line  March
require from our state-of-the peripheral equipments as well Tower 22, 2019
art facilities. We manufacture as indoor distribution
transmission towers and system). Integrated Base Station Camou aged
Communication tower for all Palm Tree
Lattice Steel Tower Antenna
terrains, environments and 0
Telecom
operating conditions. Microwave Steel Tower
WIFI
Tower

 March
20, 2019

3 legged
lattice
mast 0
triangular
radio
telecom
communication
tower

 March
18, 2019

© 2017 KEHANG. All Rights Reserved. RONSUN 

 

Privacy - Terms

www.steeltowerchn.com/technical-specifications/steel-tower-corrosion-protection/corrosion-and-protection-of-transmission-steel-structure-tower/ 5/5

You might also like