You are on page 1of 1

印尼庞卡兰苏苏火电项目部

PANGK ALAN SUSU COAL FIRED STEA M POWER PLANT PROJECT UNIT
3&4 2X200MW

监盘调整培训记录卡
DCS Screen Monitoring and Adjusting Training Record Card

培训项目 工业消防水系统
Training projects (Industrial/Fire Water System)
培训日期 培训老师
Training Date Trainer
重点关注的参数及调整方法(Important parameters and adjustment methods):
1、监视工业水箱水箱液位,保持水箱液位在 3.0~10.0m 之间,液位低,容易造成水箱水打空,泵进气,
损坏设备,液位高容易造成水箱溢流。
1. Monitor the level of industrial water tank, keep the level of water tank between 3.0 and
10.0 m, if the level is low, it’s easy to cause water tank emptying, pump air intake, it will
damage equipment, if the level is high, it’s easy to cause overflow of water tank.
2、监视画面上程控是否在自动位(AUTO),如果没有,投上自动。
2. Whether the program control on the monitor screen is in the automatic position (AUTO),
if not, put into the automatic..
3、监视启动工业水泵后工业水泵运行状态,观察电流、母管压力是否正常,带稳定后,投上联锁,避免工
业水泵出现跳停现象后,影响工业水用户用水。根据用户对水量的需求,调节工业水泵频率来控制出口母管
压力。
3. Monitor the operation status of industrial water pump after starting industrial water
pump, observe whether the current and the pressure of the main pipe are normal. After
stabilization, put into interlock to avoid the phenomenon of industrial water pump jumping
and stopping, which will affect the water consumption of industrial water users. According
to the user's demand for water, adjust the frequency of industrial water pump to control
the outlet main pipe pressure.

培训签到
SIGNATURE