You are on page 1of 7
Ambetronics Engineers Pvt. Ltd. Manufacturers of Process Control & Gas Detection Instruments & Automation System Integrator 77-8, Tarun Industrial Estate, Mogra Pada, New Nagardas Road, Andheri (East), Mumbai - 400069, India. Tol: +91-22.61673000, 28371143 + Fax : +91-22-28226570 * E-mail : sales@ambetronics.com + Web : www.ambetronics.com CIN NO.: U2925aMH2008PTC182791 * VAT NO.: 27720664681V * CST NO.: 27720664681C STANDARD WARRANTY CUSTOMER : M/S, DEEP INDUSTRIES LTD P.O.NO. POL/1617/01965 P.O. DATE : 17/06/2018 MODEL&SERIALNO. : 1). GT-4000-FLP (CH4) ~ 3602,3604,3608;3629 - 04 NOS. 2) ‘TC-800-FLP ~ 3470916 — 01 NO. <é 3) HOOTER 24 VDC ~ 361216-SPR~ 01 NO. DISPATCH DATE + 24/07/2018 AMBETRONICS ENGINEERS PVT. LTD. hereby certifies that the above equipment has been tested & approved by ac. AMBETRONICS ENGINEERS PVT. LTD. Warranties the above equipment for a period of Twelve months from the date of dispatch. This Warranty is .d to either repair or replacement of manufacturing defects & does not include damage due to mishandling, improper use, improper storage, natural calamities or accidental. During the warranty period for any repair or part replacement the equipment should be send to AMBETRONICS ENGINEERS PVT. LTD, factory. Ambetronics Engineers Pvt. Ltd. ‘Manufacturers of Process Control & Gas Detection Instruments & Automation System Integrator 17-8, Tarun industiol Estate, Mogra Pada, New Nagardas Road, Andheri (Ean), Mumbal ~ 400089, In Tots +91-22-60096825, 28371143 + Fax : +-91-22.28226570 + E-mall : eales@ambetronies.com » Wed = wrwcambetronics.com TEST & CALIBRATION REPORT: DIGITAL SCANNER / LOGGER / MONITOR CUSTOMER DETAILS: [NAME DEEP INDUSTRIES LTD LOCATION + AHMEDABAD P.0.No._:Po/1617/01965 Dated _:17-05.2018 INSTRUMENT DETAILS: instrument Type : Multichannel Gas Monitor ‘Model No T6-800-FLP rN, 3940736 zalvate __: 23/07/2018 Due Date : 22/07/2019 ee ! “Traceability Details: ! instrument Type: Digital Multimeter (634 Digit) “Model No. "wm 4050 SeNe. + 1405208 calibrated By: Electronics Regional Test Laboratory. Report No: ERTL(W}/ 201658181 } Calibration Date : 04/03/2018 Due Date : 04/03/2019 Specification Details: Specifications Customer Requirement ‘Specification Of instrument Remarks Number Of Channels os channet [08 channel oK instrament Sie '350(H)x290(W)x170(0) in mm 350(H)290(W)X170(0) in mm ox Power Supply Iso-270v ac/oc Iso-270v ac/oc ox | [aC Current i [46-oarna ok Signal input 1708 CH420mA To cH&20mA ox Range programmable [Programmable ox [Accuracy [50.25% OF FS [£0.25% OF FS OK Resolution 5 programmable OK ISofware Version sais oK \pitertace [Serial Por Serial Port NA [Relay Output /Grouping 2 Common Relay [2 common Relay ox Testing DETAUS: FUNCTIONAL CHECKS: Parameter Check ea [status Parameter status Parameter status Vibration Test 10Min_[ OK |Oata Scanning OK splay BLED Status ox (Oven Test at 50° pay OK _ |oata togeing NA [Warm Up Testat Ambient |10Min_| OK [Data Printing NA Contactor Test at Ambient [10min | OK |Reai Time Clock NA lunder & Over Voltage Test |S Min 0K [Relay Condition ox high voltage Test at .5KV [1 min NA FORM No: PO/AM/F/O7 REV No: 00 Date: 01.08.2017 AMBETEONS Ambetronics Engineers Pvt. Ltd. Manufacturers of Process Control & Gas Detection Instruments & Automation System Integrator TEST & CALIBRATION REPOR' CUSTOMER DETAILS: Name! M/S. DEEP INDUSTRIES LTD Location : AHMEDABAD PO. No. : POL/1617/01965 Dated : 17.06.2018 INSTRUMENTDETAILS: 1 Tnstrument Type 1GASTRANSMINTER Model No. GT-a000-FLP Sr. No. 8802 | Gas METHANE Range ‘0 to 100% LEL Testing Date 22/07/2018 Due Date : 21/07/2019 “TRACEABILITY DETAILS: = | Instrument Type : Digital Multimeter (6 % Digit) Model No. DMM 4050 Sr. No. ? 1405208 Calibrated By + Electronics Regional Test Report No: | Laboratory(West) ERTL(W)/2016 S&C 181 | Calibration Date : 04/03/2018 Due Date: 04/03/2019 DETAILS OF STANDARD GASES USED: [~ Calibration | Gas Composition | Cylinder Certificate No. Dated Make | | Used No. Mi ace | AMBIENT Zero Calibration A | Zero Calibration aa NA NA NA N Range 50% LEL ; F : mere ena 128872 PGPL/36/2016-16/445 | 05/10/2016 | PHOENIX BI D F : Calibration Gas used Required READING OBSERVED ON ‘Acceptable Reading TRANSMITTER SR. NO. 3480916 | Tolerance %LEL | % LEL, limit Zero Calibration | AMBIENT AIR 00 00 +2% Range Calibration | METHANE 50 50, [2% [CALIBRATED BY: _veriries ove) APPROVED BY: ae tprooucmo excineen) | (HEADOESEERETIMENT) | From No: PD/AM/F/08 REV No: 03 DATE: 01.08.2017 AMpETRONICE Ambetronics Engineers Pvt. Ltd. Manufacturers of Process Control & Gas Detection Instruments & Automation Syatem Integrator ‘(East Mumbai - 400069, ini CUSTOMER DETAILS: Name! M/S. DEEP INDUSTRIES LTD Location : AHMEDABAD PO. No. : POL/1617/01965 Dated: 17.06.2018 INSTRUMENT DETAILS: Instrument Type | GAS TRANSMITTER Model No. : GT-4000-FLP Sr. No. 8604 Gas : METHANE Range 0 to 100% LEL Testing Date 22/07/2018 Due Date : 21/07/2019 ‘TRACEABILITY DETAILS: Instrument Type : Digital Multimeter 6 % Digit) Model No.: DMM 4050 Sr. No. ¢ 1405208 Calibrated By: Blectronies Regional Test Report No: Laboratory(West) ERTL(W)/2016 S&C 181 Calibration Date :04/03/2018 Due Date : 04/03/2019 DETAILS OF STANDARD GASES USED: Calibration Gas Composition |” Cylinder Certificate No. Dated Make Used No. AMBIENT Zero Calibration NA NA NA NA AIR | Range | 50% LEL ‘ ayy mole 2 ecmeeeeGenerae 128872 | PGPL/36/2016-16/445 | 05/10/2016 | PHOENIX ‘CALIBRATION DETAILS OF TRANSMITTER: ‘Calibration Gas used ‘Required READING OBSERVED ON ‘Acceptable Reading ‘TRANSMITTER SR. NO. 3490916 | Tolerance %LEL %LEL limit__| Zero Calibration | AMBIENT AIR 00 00, #2% Range Calibration | METHANE 50 50 42% pie ca (PRODUCTION ENGINEER) From No: PD/AM/F/08 REV No: 03 DATE: 01.08.2017 Aaaunerngnics Ambetronics Engineers Pvt. Ltd. ‘Manufacturers of Process Control & Gas Detection Insiruments & Automation System Integrator 77-8, Torun indusinal Estate, Mopra Pada, New Nagardas Road, Andheri (East). Mumbai - 400068, inde, Tol: +91-22-68008628, 20371143 » Fax: #91-22-28226870 + E-mal: sales@ambetronics.com + Web: waw.ambetronics.com TEST & CALIBRATION REPORT: GAS DETECTOR CUSTOMER DETAILS: Name ‘M/S. DEEP INDUSTRIES LTD Location : AHMEDABAD PO. No. : POL/1617/01965 Dated 17,06,2018 INSTRUM) Instrument Type: GAS TRANSMITTER ‘Model No. : GT-4000-FLP. Sr. No. +3608 Gas METHANE Range 0 to 100 % LEL Testing Date 22/07/2018 Due Date : 21/07/2019 ‘*TRACEABILITY DETAILS: ; : Instrument Type : Digital Multimeter (6 % Digit) “Model No. DMM 4050 Sr. No, 1405208 Calibrated By Electronics Regional Test Report No: Laboratory(West) ERTL(W)/2016 S&C 181 Calibration Date : 04/03/2018. Due Date : 04/03/2019 DETAILS OF STANDARD GASES USED: = z Calibration Gas Composition Cylinder Certificate No. Dated Make Used No. - AMBIENT ee Calibration AIR NA NA NA NA Range 50% LEL a ee 7 | a Calibration METHANE 128372, PGPL/36/2016-16/445 ees PHOENIX ‘CALIBRATION DETAILS OF TRANSMITTER: © Calibration — Gas used Required READING OBSERVED ON ‘Acceptable Reading TRANSMITTER SR. NO. 3500916 Tolerance % LEL % LEL limit Zero Calibration | AMBIENT AIR 00 00 42% Range Calibration METHANE 50, 50, £2% CALIBRATED BY pe (PRODUCTION ENGINEER) From No: PD/AM/F/08 REV No: 03 DATE: 01.08.2017 AMBETRONICS Ambetronics Engineers Pvt. Ltd. (ocess Control & Gas Detection Instruments & Aulomatlon System Integrator 17-8, Tarun Indusval Estate, Mogra Pada, New Nagardos Road, Andheri (East). Mumbal - 400069, India. Yel: +91-22-66905825, 28371143 + Fax: 191-22-26226570 » E-mail: salen@ambetronics.com = Web: www-ambetronics.com TEST & CALIBRATION REPORT: GAS DETECTOR Manufacturers of CUSTOMER DETAILS: (Name = M/S, DEEP INDUSTRIES LTD Location ? AHMEDABAD PO. No. : POL/1617/01965 Dated: 17.06.2018 INSTRUMENT DETAILS: [Instrument Type: GAS TRANSMITTER Model No. : GT-4000-FLP Sr. No, # 3629 Gas : METHANE Range £0 to 100% LEL <_ Testing Date 22/07/2018 Due Date + 21/07/2019 ‘TRACEABILITY DETAILS: Instrument Type : Digital Multimeter (6 % Digit) ‘Model No. = DMM 4050 Sr. No, ? 1405208 Calibrated By: Electronics Regional Test Report No: Laboratory(West) ERTLAW)/2016 S&C 181 Calibration Date : 04/03/2018 Due Date : 04/03/2019 "DETAILS OF STANDARD GASES USED: eS Calibration | Gas Composition | Cylinder Certificate No. ‘| Dated Make Used No. ‘AMBIENT | Zoro Calibration jn NA NA NA NA Range 50% LEL : 7 Saat ieee Seen tsar PGPL/36/2016-16/445 | 05/10/2016 | PHOENIX CALIBRATION DETAILS OF TRANSMITTER: |S Calibration Gas used Required READING OBSERVED ON Acceptable | | Reading TRANSMITTER SR. NO. 3510916 | Tolerance % LEL. % LEL limit. Zero Calibration | AMBIENT AIR 00 00 #2% Range Calibration 50, 50 #2% (CALIBRATED BY: ~ VERIFIED 4 ee (PRODUCTION ENGINEER) APPROVED B) - (ead OF DEPARTMENT) From No: PD/AM/F/08 REV No: 03 DATE: 01.08.2017 491-022-2761 1055 info@phoenixgases.com www phoonbxgases.com 9/5, MIDC, TTC. Industrial Area, Turbhe, Navi Mumbai 400 705. +91-022- 6534 6061 PHOENIX GASES PVT CERTIFICATE OF ANALYSIS Name of Party ‘Ambetronics Engineers Pvt. Ltd. fall Reference No. PGPL/36/2016-16/445 Date of analysis (05/10/2016 P.ONO. & Date 1516P00682 Dated - 26-09-2016 / 125 Ke/Cm' ration Tolerance 47-10% Certification Accuracy 2% 2 Stability 12 Month Cylinder No. 128372 ‘Cylinder capacity 1.8 Lit. A/L Cylinder Basis Refilling < $R.NO. | Components ‘Ord. Conc. | Certified Cone. | Analytical Method is Methane 50% LEL (2.5 %) 2.52% A 2. Air Balance Balance A Analytical Methods: = ‘A= Gas Chromatography (TCD) F-Multi Gas Analyzer | K-Chlorine Gas Monitor B— Gas Chromatography (FID) CO Gas Monitor __| L-HCL Gas Monitor ‘C Gas Chromatography (FID) TE-H2S Gas Monitor | M-Ammonia Gas Monitor Methanizer D=Trace Oxygen Analyzer ENO2 Gas Monitor | N-NO Gas Monitor E-Dew Point Meter ‘S02 Gas Monitor I Note: S _ The Reference standards are gravimetric/volumetric filled Mixture whereon the standard ‘weights are traceable to NPL, New Delhi whose reference standards are traceable to NIST. uzeteownr999PTe121592 cin no Aporea by

You might also like