Supplying, handling, fitting 113mm dia UPVC pipe conforming to IS:12818;1992. The pipe should beof male-female socket type, 8kg/cm2 strength and
of TIRUPATI/FINOLEX OR equivalent make. Rate to include supply, transportation and lowering of pipes, fittings and accessories like drill plug with
lock at bottom, well cap etc complete. Necessary proof of manufacturer and specification conformance is to furnished before pipe lowering. Only
length lowered shall be paid
Providing and filling all around the annular portion between the pilot hole and main pipe for full depth, approved quality pea gravel (size 3mm to 10mm)
to make the surrounding perforated as per the specifications of the the site-in-charge.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 1 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
Same as item no. 15 but for beyond 3 m depth
18 EXCAVATION-HARD ROCK<=3M Cubic
Metres
Description same as item no.15 except the soil will be hard rock and the excavation should be carried out by pneumatic tools like jack hammer, chisels,
or by blasting taking all safety precautions and approvals as required. For 0-3 m depth
Note: For all cutting/excavation and filling jobs, it will be the responsibility and duty of the contractor to take joint initial levels with Engg.-In-Charge in
all cases before commencing the work. The joint levels should be certified by the contractor as well as HPCL Engg.-In-Charge. The payments will be
made basis the initial levels and final levels taken jointly and certified. The payment for all cutting / excavation will be made at the lower rate applicable
for 0 to 3 m and the higher rate will be paid only for the portion beyond 3 m depth. If the contractor fails to take jointly certified levels, the levels as
taken by HPCL Engg.-In-Charge shall be treated as final and all payments will be released basis the levels so taken by the HPCL Engg.-In-Charge.
Same as Item No.23 but for PCC 1:4:8 using 40 mm and down size graded stone aggregates
28 PCC WORK-1:5:10 Cubic
Metres
Same as Item No.23 but for PCC 1:5:10 using 40 mm and down size graded stone aggregates
Providing and laying PCC 1:1.5:3 mix using 20mm and down stone aggregate for grouting Angles/MS Structurals. Other specs as per item no. 23. MS
Structurals will be paid for separately.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 2 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
31 RCC1:1.5:3FOUND.PLNTH.RET. WAL Cubic
Metres
REINFORCED CEMENT CONCRETE : Providing , Mixing, laying and placing RCC 1:1.5:3 mix with ordinary Portland cement using 20 mm and down
size graded crushed stone aggregate including providing and fixing necessary plywood(minimum 19 mm thick)/ steel shuttering , scaffolding, machine
mixing, compacting by mechanical vibrators (needle / skid etc), curing, hacking the surface to receive plaster using plastic / PVC sheet of thickness
minimum 20micron under RCC, as directedwherever required. etc. all complete. Machine mixing to be done without exception. Rate shall be exclusive
of the cost of steel reinforcement, Concrete shall conform to relevant specifications of IS 456:2000 Latest Edition. For footings/foundations / plinth
beam / floor beam / retaining wall etc.
Superplasticiser Rheobuild SP1 (Napthalene base) shall be dosed in mixing water after 50-70% of mixing water has been added in the mixer machine.
The Dosage will be in the range of 0.6% to 0.8% by weight of cement (i.e. 300ml - 400ml per 50 kg. bag of cement) to get desired workability.
Equivalent Napthalene based superplasticiser may be used in manufacturer's specified proportions/methods after prior approval of Engg.-in-Charge .
32 RCC1:1.5:3COL.SLAB.TIE.CLVRT…. Cubic
Metres
Same as Item No.30 but for Column / Tie beams / Chhajja / Lintel / roof slab / stair case / culvert slab etc.
33 RCC1:1.5:3 FOR COPING Cubic
Metres
Same as Item No.30 but for Coping
41 BRICKMASONRY:SUPERST.-NEWBRICK Cubic
Metres
SUPER STRUCTURES. Providing and laying brick Masonry as item no. 38 but for superstructure above DPC level including scaffolding.
42 BRICKMASONRY:SUPERST-OLDBRICKS Cubic
Metres
SUPER STRUCTURE : Same as item no. 38 but using old bricks taken out from demolished masonry. Rate includes removing mortars and cleaning of
bricks etc. complete. Once the demolition is over, the party has to take out the usable good bricks and stack them properly to enable Engg.-In-Charge
to assess the quantity of bricks for future reference and calculation. Once the assessment is made it is duty of the contractor to obtain certificate from
Engg.-In-Charge about the quantity of usable bricks available before these bricks are put to use. In absence of certificate no payment will be made.
However, in no case the old bricks shall be used without the assessment of quantity and clearance to use the old bricks is given by the Engg.-In-
Charge.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 3 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
Same as item no.38 but for 115 mm thick in partition walls in CM 1:4. Rate to include providing 75 mm thick RCC 1:1.5:3 bands using 2 nos 8 mm dia
Torsteel reinforcement at every 1 M height of wall including plywood/ MS shuttering. Steel reinforcement shall be paid for separately.
If masonry wall is over 600mm thick, a line of headers (not less than 450mm length ) overlapping each other by 150mm shall be laid. Bond stones shall
be distinctly marked on its face during construction for verification. Quoin / key / corner stone shall not be less than 0.03cum in volume. FOR
SUBSTRUCTURE
If masonry wall is over 600mm thick, a line of headers (not less than 450mm length ) overlapping each other by 150mm shall be laid. Bond stones shall
be distinctly marked on its face during construction for verification. Quoin / key / corner stone shall not be less than 0.03cum in volume.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 4 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
Providing Brick on edge soling 4.5" thick (including sand bedding), surface dressing, making required slope, soaking the bricks before laying, packing
the gaps using sand and watering etc all complete.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 5 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
Providing, fabricating, welding and fixing structural steel in position with angle iron / flats / tees / squares / SHS tubes conforming to IS 4923 : 1997,
plates etc as per design and direction given by Engg.-In-Charge for drain grating, manhole frames, gratings ,tree guards, Island Covering Frame etc,
as per requirement. Job includes all necessary grouting, supply and fixing of handles, nuts - bolts etc, painting the grating with 2 coats of approved
synthetic enamel paint, over a coat of red oxide primer.
Rate to include supplying and fixing of required collars and fixing the same by using cement mortar 1:3. All pipes must be new and perfectly sound,
free from cracks, cylindrical, straight and of standard nominal diameter and length with even texture. Test certificates from manufacture shall be
submitted and approved by Engg.-In-Charge before use, all complete. Diameter 1000mm NB
Plinth area of building at ground floor only shall be measured for payment. The work shall be carried out by a qualified agency as approved by Engg.-
In-Charge. Contractor will have to submit 10 years guarantee bond on Rs. 100/- stamp paper for the treatment.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 6 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
78 CERAMIC TILE FLOORING Square
Metres
Providing and laying matt finish Ceramic tiles of approx 8 mm thick of size as specified in flooring. The tiles used should be of KAJARIA make of Group
- IV or equivalent group of approved makes. The tiles should be of first quality of approved make and shade and free from cracks, warpage, fissures
and flakes with straight edges and perfect corner laid at right angle as per design & pattern over a bedding of cement mortar 1:5 of average 30 mm
thick, finishing the joints neatly with white cement mixed with matching colour pigment and finish in all respect with all material and labour complete
giving required slope as directed by Engg.-In-Charge. If necessary, surface unevenness shall be filled up with brick ballast manually compacted with
watering etc. complete as per instructions of Engg.-In-Charge without extra cost. Tiles size shall not be less than 300x300 mm. Basic Rate - Not lower
than Rs.350/sqm
Tiles size shall vary between 300x300 mm (minimum) and 600X600 mm (maximum) as directed by Engg.-In-Charge. If necessary, surface
unevenness shall be filled up with brick ballast manually compacted with watering etc. complete as per instructions of Engg.-In-Charge without extra
cost. Basic rate not lower than Rs. 700/- per sqm.
If necessary, surface unevenness shall be filled up with brick ballast manually compacted with watering etc. complete as per instructions of Engg.-In-
Charge without extra cost.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 7 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
90 KOTA STONE FLOORING / STEPS Square
Metres
Providing and fixing 20 mm thick Kota stone slabs with 25mm bedding CM 1:3, cement slurry and machine polishing on one side. The tiles should be
of first quality and free from cracks, warpage, fissures and flakes with straight edges and perfect corner laid at right angle as per design and pattern
over a bedding of cement mortar 1:5 of average 30 mm thick, finishing the joints neatly with white cement mixed with matching colour pigment and
finish in all respect with all material and labour complete, giving required slope as directed by Engg.-In-Charge.
If necessary, surface unevenness shall be filled up with brick ballast, manually compacted with watering etc. complete as per instructions of Engg.-In-
Charge without extra cost. In case of step slabs, one piece slab to be used. The slab shall not have exposed sharp edges. The exposed edges shall be
grinded and polished in smooth curvature.
95 SKIRTING Running
Metre
Providing and fixing tile skirting of approved shade and make of First quality free from crack fissures & flakes with straight edges & perfect corners
fixed at right angles of 150 mm height using cement mortar bedding 1:3 and fixed with neat cement slurry and finishing the joint with white cement
mixed with matching colour pigment . Rate to include necessary chipping if required in masonry / concrete, so that skirting is projecting uniformly 6mm
from plastered face. All vertical joints of skirting should match with floor tiles spacing uniformly complete as per direction of EIC.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 8 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
Providing and fixing terracotta tiles minimum 3 mm thick and minimum 75x150 mm size of approved shade and make First quality , free from crack
fissures & flakes with straight edges & perfect corners fixed in true line & level as per the design and pattern advised by Engg.-In-Charge. Rate
includes applying 12 mm thick backing plaster in 1:3 CM in true line & level, properly cured & rough finished. Fixing the tiles with neat cement paste
and finishing the joints with terracotta paint in a neat & aesthetic way complete in all respects. Approved Make of Tiles: Dazzle Designer Tiles of Milan -
Terracotta smooth finish
The slab should have following minimum dimensions. Width = 0.8 M, Length = 1.2M, Thickness = 18 mm, The slabs have to be fixed by taking
services of highly skilled mesons true to plumb complete in all respect. Granite slabs used shall not be more than six nos. In case of increase in no. of
slabs prior approval of Engg.-In-Charge shall be obtained.
With fixing LOGO supplied by HPCL: Including fixing of logo and electrification for the same. Granite used shall be minimum 18 mm thick.
Contractor will be required to submit a guarantee on Rs. 100/- stamp paper for a period of 10 years in respect of performance of waterproofing.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 9 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
THERMAL & MOISTURE PROTECTION (roof water proofing) : Providing and laying the following roof water proofing treatment consisting of (i) First
layer of 50 mm thick CC 1:3:6 over roof slab laid to falls and slope on minimum 1:100 and finished smooth to receive water proofing membrane. (ii)
Second layer of 3mm thick polyester reinforced modified bituminous water proofing membrane including primer coat as per manufacturer's
specification. (iii) Third layer of 150 micron polythene sheet laid over the water proofing membrane.
(iv) final layer of 25mm thick 600mm x 600mm precast concrete tiles of M-25 grade with 10mm grooves filled up with cold bitumen to form 600x600mm
panels as contraction joints all material and labour complete in all respect. Contractor will be required to submit a guarantee on Rs. 100/- stamp paper
for a period of 10 years in respect of performance of waterproofing.
All holes, cracks, patches etc shall be made good with material similar to that of the surface. The painting shall be applied in specified coats or more
so as to obtain the desired finish. If additional coats are required to obtain uniform and smooth finish, the same shall be carried out at no extra cost.
The job includes provision of scaffolding using safety precautions, curing etc as required.
WHITEWASH : Providing and applying 3 coats of white wash to plastered and concrete surfaces by mixing binder, , glue, indigo etc. complete as per
IS: 712- Latest Edition.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 10 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
125 ECONOMY EMLSN. PAINT-INTERIOR Square
Metres
Providing and applying 2 coats ( first coat with brush and final coat with Roller) of approved shade Economy Emulsion (Bison Super Emulsion of Beger
or approved equivalent) paint on all surfaces and heights to give an even shade including primer and compatible putty. General
specifications/guidelines given under item no.120 also to be followed, as applicable.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 11 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
136 TEAK WOOD DOOR FRAME Running
Metre
Supply and fixing seasoned (IS 1141:1993 latest edition) pretreated (IS 401 : 2001 latest edition) teak wood frame for flush door installation and of
125x63 mm nominal cross section. The timber will be sound, straight and free from sap, radial cracks, decay, fungal growth, boxed heart, pitch
pockets, borer holes, splits, loose knots, rots or any other flaws. Rates are inclusive of 25x10 mm teakwood beading of same specification and
matching colour polish covering junction of frame and wall in true line, level and finish.
Rate to include all labour, carpentry, making chases, grooves, polish and provision of 6nos. M.S.holdfast 25x4x230mm per frame with nuts and bolts
as required and grouted in situ in concrete blocks of mix 1:2:4 and of size as directed. For concrete surfaces, 12mm diameter counter sunk anchor
bolts or coarch screws shall be used for fixing of all door frames, finishing the frames with putty and two coats of approved matching polish/enamel
paint. Inner surface of teak wood frame shall be coated with anti-termite solution etc. all complete.
polysulphide sealant / silicon sealant etc complete as per architectural drawing and instruction of Engg.-In-Charge. Al anodised shop front doors with
frames at top and bottom (without any vertical aluminium section) of HINDALCO make - section no.
SP-2670 of size 88x42x2.3 with weight of 2.927 kg/m for door top and bottom, round acrylic handle using CP brass / Stainless steel screws. The glass
should be single piece only. All glass edges shall be grinded and polished smooth as per instructions. The floor spring strut shall be fixed and
accommodated in Aluminium section groove. In case of non-availability, approved equivalent make for Al sections is JINDAL. Approval of Engg.-In-
Charge shall be taken before using equivalent sections matching next higher dimensions and weight per running metre without extra cost. Approved
Make of Glass: AIS, Modi, Saint Gobain, Triveni
sealant / silicon sealant etc complete as per architectural drawing and instructions of Engg.-In-Charge.
Al anodised shop front fixed glazing with frames at top and bottom of HINDALCO make section no. SP-2670 of size 88x42x2.3 with weight of 2.927
kg/m or approved equivalent and at two side ends of HINDALCO make section no. SP-730 of size 63.5x38x3 with weight of 1.55 kg/m or approved
equivalent and fixing cleats/clips of HINDALCO make section no. SP-1778 of size 17.15x17.27x1.4 with weight 0.175 kg/m without any intermediate
vertical aluminium sections at joints. The intermediate vertical joints spacing in glass shall not be less than 3 m c/c and no horizontal joints shall be
permitted in glass. The vertical joints shall be finished smooth having machine cut glass edges in true plumb, line and level. The joint shall be treated
with silicon sealant to stop water ingress and glass surfaces shall be cleaned neat of left over sealant. Prior approval of HPCL Engg.-In-Charge shall
be obtained if spacing of vertical joints is needed to be less than 3 m c/c. Approved Make of Glass: AIS, Modi, Saint Gobain, Triveni. In case of non-
availability, approved equivalent make for Al sections is JINDAL.
Approval of Engg.-In-Charge shall be taken before using equivalent sections matching next higher dimensions and weight per running metre without
extra cost.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 12 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
HYDRAULIC FLOOR SPRINGS Providing and fixing double action hydraulic floor springs of approved brand ( HARDWYN / EVERITE/ SANDHU)
conforming to IS 6315 : 1992 for aluminium doors. Rate to include cutting of floors as required, embedding in floors and cover plates etc complete as
per specifications. Load Capacity = 61-80 kg
rawl plugs and screw or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions, at top , bottom and sides
with requisite PVC/neoprene felt/polysulphide sealant/silicon sealant including hard ware such as tower bolt of 150 mm length from inside and
Aluminum handle and Aluminum aldrop of 200 mm length
on both sides, 3 nos. Aluminium hinges of 100 mm length etc all complete as per architectural drawing. Aluminium door section of JINDAL make or
equivalent make with the following section : Main frame on all sides - 4700 -101.6 x 44.45 x 2.5 of weight 1.977 kg/m Shutter vertical frame- 4537 -
53.7x44.45x2.3 of weight 1.238 kg/m. Shutter top frame - 4540 - 53.7x44.45x2.3 of weight 1.173 kg/m.
Shutter middle frame - 4621 - 49.91x44.45x3 of weight 1.495 kg/m Shutter bottom frame - 4524 -83.5x44.45x3 of weight 2.107 kg/m, aluminium Cast
Door handle and Clip - 4420 - 19x17.3x0.9 of weight 0.124 kg/m. In case of non-availability, approved equivalent make for Al sections is HINDALCO.
Approval of Engg.-In-Charge shall be taken before using equivalent sections matching next higher dimensions and weight per running metre without
extra cost.
Aluminium door section of JINDAL make or equivalent make with the following sections : Outer frame - 8804 of weight 0.622 Kg/m Shutter frame-
8802 of weight 0.575 kg/m; Mullion - 8803 of weight 0.729 kg/m; Cleat angle (HIDALCO make) A-3350 - 38x25x3 of weight 0.490 kg/m; Glazing clip -
4433 of weight 0.137 kg/m. Approved Make of Glass : AIS, Modi, Saint Gobain, Triveni. In case of non-availability, approved equivalent make for Al
sections is HINDALCO. Approval of Engg.-In-Charge shall be taken before using equivalent sections matching next higher dimensions and weight per
running metre without extra cost.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 13 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
152 ALUM. DOOR/FIXD. GLZ. 6 MM GLASS Square
Metres
ALUMINIUM DOOR/FIXED GLAZING WITH 6 MM GLASS : Providing and fixing 15 micron coloured anodised aluminium fixed glazing/aluminium door
with 6 mm glass extruded built up section of wall thickness not less than 1.5 mm and approve make with glass panel fixed with Aluminium snap
beading/ Neoprene / PVC gasket/CP Brass /stainless steel screws and fixed to the wall with requisite rawl plugs and screw or with fixing clips or with
expansion hold fasteners including necessary filling up of gaps at junctions, at top , bottom and sides with requisite PVC / neoprene felt/ polysulphide
sealant/silicon sealant all complete as per architectural drawing and the direction of Engg. In-charge.
Aluminium section of JINDAL make or equivalent make with the following sections :
Fixed Glazing:
Outer frame sections - 4688- 63.5x38.1x1.65 of weight 0.942 kg/m.
Intermediate frame - 4687- 63.5x38.1x1.53 of weight 0.942 kg/m.
Glass panels used shall not be less than 2.4 m (height) x 1.2 m (width). All the joints shall be provided with Aluminium sections as specified.
Door:
Outer side frame - 4550 - 47.62x44.45x1.52 of weight 0.881 kg/m.
Bottom frame - 4553 - 95.25x44.45x1.70 of weight 1.301 kg/m
Intermediate frame - 4621- 49.91x44.45x1.60 of weight 0.882 kg/m.
Clip- 4420- 19x17.3x0.9 of wt. 0.124 Kg/m.
The floor spring strut shall be fixed and accommodated in Aluminium section groove. The door shall be provided with die cast aluminium handle,
towerbolt, locking arrangement etc. complete. The joints and gaps shall be treated with silicon sealant to stop water ingress and glass surfaces shall be
cleaned neat of left over sealant. Approved Make of Glass: AIS, Modi, Saint Gobain, Triveni. In case of non-availability, approved equivalent make for
Al sections is JINDAL. Approval of Engg.-In-Charge shall be taken before using equivalents matching next higher dimensions and weight per running
metre without extra cost.
Hood Covers : MS sheet of 0.9 mm thick Locking handle : To be provided suitably. Rate shall include providing and fixing holdfasts and painting two
coats of enamel paint of approved make and shade over two coats of zinc phosphate primer. Shutter up to 10 SQM -push pull type hand operated with
ball bearings , For 10 SQM upto 30 SQM- Mechanical operated gear type with ball bearing, a pulling hook shall be provided for each of the rolling
shutter.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 14 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
159 FAN HOOKS Each
FAN HOOKS : Providing & fixing MS fan hooks with 16 mm dia MS bar bent to shape with hooked ends in RCC Slab during laying including painting
the exposed portion.
The rate quoted shall include cost of bolts, nuts, washers, welding and electrodes and any other consumables required for completing the work. The
bolts , nuts , washers, welds etc shall not be separately measured and paid for.
The ceiling sections should be fixed to intermediate channels with connecting clips (India Gypsum code no. ME9). GI grid shall be fixed to RCC slab
above with the help of 25x0.5 mm strap hanger (India Gypsum code no. MF 8) and soffit cleat (India Gypsum code no. P534). The joints between soffit
cleat and strap hanger and GI grid & strap hanger shall be with 6.4x12.7 mm nut and bolt (India Gypsum code no. P526). Soffit cleat shall be fixed to
RCC ceiling with W.E. type 12 mm dia, 17/16" long steel rawl plug. Maximum c/c distance (both ways) of strap hangers shall be 1200 m. The
Gypboard shall be fixed fixed to GI grid with 25 mm long Drawall screws. The Gypboard to be used shall be 12.5 mm thick tapered edge boards. The
boards shall be taped & filled from underside to ceiling.
The rate shall be inclusive of additional ceiling sections and intermediate channels shall be provided at openings for light fixtures, AC ducts, vertical
drops, offsets etc Additional intermediate channels shall be fixed to strap hangers at every 1200 mm for additional support to prevent strap hangers
from buckling/swaying. Item to be completed in all respect including necessary sleeves for ducts , finishing of joint cut outs, supports for AC grills, light
fixtures, speakers etc. complete as per directions of Engg.-In-Charge.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 15 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
169 ACOUSTIC. SUSP. CEILING TEGULR Square
Metres
Providing & Fixing of Armstrong Acoustical Suspended Ceiling System with Fissured Tiles having Tegular edges . The tiles should have Humidity
Resistance of 90% RH, Average NRC .50, Light Reflectance >80%, Thermal Conductivity k = 0.052 – 0.057 w/m°c, Colour White, Fire Performance
Class 0/Class 1 (BS - 476) in module size of 600mm x 600mm x 15mm laid on 24XL - Hot Dipped Galvanised steel suspension System having rotary
stitching on the Main Runner, 1200 mm & 600 mm Cross Tees.
INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural socket by approved hanger at 1200mm
maximum centre. The last hanger at the end of each main runner should not be greater than 450mm from the adjacent wall.
Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer
than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200
mm cross tees.
Perimeter trim to be Armstrong wall angles or channel, secured to walls at 450 mm max. C/c
For fissured RH 90 Tegular Edge.
(B) 15mm NB CP brass angle valve of approved brand as per the direction of Engg.-In-Charge (C) 15 mm NB CP brss inlet connection with Brass
unions at the ends. (D) Parryware/Commander make or equivalent matching colour polypropylene seat cover with necessary brass hinges and
rubber bushes etc (E) WC connector with neoprene rubber etc. Approved Equivalent - Hindware 20028 with matching colour Vitreous China cistern
with all mechanisms, fittings etc. complete.
(B) 15mm NB CP brass angle valve of approved brand as per the direction of Engg.-In-Charge (C) 15 mm NB CP brss inlet connection with Brass
unions at the ends. (D) Parryware/Commander make or equivalent matching colour polypropylene seat cover with necessary brass hinges and
rubber bushes etc (E) WC connector with neoprene rubber etc. Approved Equivalent - Hindware 20028 with matching colour Vitreous China cistern
with all mechanisms, fittings etc. complete.
(C) 32 mm CP brass flush pipe of approved length with necessary fittings, clamps etc. (D) 15 mm NB CP inlet connections with brass union at the
ends. (E) 15mm NB CP brass angle valve of approved brand as per the direction of Engg.-In-Charge (F) WC connector with neoprene rubber.
Approved Equiv. - Hindware Cat. 20004 with equivalent low level cistern
(C) 32 mm CP brass flush pipe of approved length with necessary fittings, clamps etc. (D) 15 mm NB CP inlet connections with brass union at the
ends. (E) 15mm NB CP brass angle valve of approved brand as per the direction of Engg.-In-Charge (F) WC connector with neoprene rubber.
Approved Equiv. - Hindware Cat. 20004 with equivalent low level cistern
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 16 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
176 URINAL-NEW MAGNUM COLOURED Each
Supplying and fixing PASTEL COLOURED vitreous china urinal of Parryware make New Magnum Series No. 0575, CP flush valve, CP pipe
connection, CP waste coupling , CP Brass bottle trap, 32 mm PVC waste line of required length etc. all complete as per the direction of Engg.-In-
Charge. Approved Equivalent - Hindware 60006 Olympous half stall
(d) Providing and fixing brass CP Jaquar make 13mm half turn pillar cock. (Cat. no.011) Rate to include supply, painting and fixing of necessary CI
brackets with nuts and bolts and fixing the wash basin with all necessary connections in walls.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 17 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
Supplying and fixing of 150 x 150 mm pastel coloured toilet paper holder of Hindustan Sanitary ware or equivalent approved make at required position
and elevation as directed. Rate to include making good the chases in walls after fixing the above.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 18 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
192 TOWEL RAIL Each
Providing and fixing CP brass towel rail of 20 mm dia and 600 mm long including all accessories such as brackets (coloured), fixing and anchoring etc.
complete as directed.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 19 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
210 BIB COCK-2 WAY-JAQUAR 23041 Each
Providing and fixing in position CP brass bib cock of Jaquar make Clarion Range No.23041. Approved equivalent Parko make.
Providing and fixing in position CP brass angular stop cock (regulating valve) of Jaquar Clarion Range No. 23053. Rate to include all related civil
repairs, fitments, joineries etc. complete.
Providing and fixing in position CP brass long thread angular stop cock (regulating valve) of Jaquar Clarion Range No. 23055. Rate to include all
related civil repairs, fitments, joineries etc. complete.
Providing and fixing in position CP brass concealed stop cock (reduced body) of Jaquar Clarion Range No. 23069. Rate to include all related civil
repairs, fitments, joineries etc. complete.
Providing and fixing in position CP brass Extra Heavy Body concealed stop cock with adjustable wall flange of Jaquar Clarion Range No. 23083. Rate
to include all related civil repairs, fitments, joineries etc. complete.
Providing and fixing in position CP brass male end stopcock of Jaquar Clarion Range No. 23093. Rate to include all related civil repairs, fitments,
joineries etc. complete.
Providing and fixing in position CP brass female end stopcock of Jaquar Clarion Range No. 23097. Rate to include all related civil repairs, fitments,
joineries etc. complete.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 20 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
228 PVC PIPE - 110 MM, 4KG/SQCM Running
Metre
PVC SOIL / WASTE /RAIN WATER PIPES Supplying and laying 110 mm PVC pipe of 4KG/sqcm pressure rating including plain or door type bends,
shoes, offsets, clamps junctions, tees, etc, complete .
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 21 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
242 GULLY TRAP WITH CHAMBER Each
GULLY TRAP WITH CHAMBER Providing and fixing square mouth gully trap including constructing 300 X 300 MM internal size brick masonry
chamber with 230mm thick brick masonry in 1:5 cement mortar, excavation, 75mm thick PCC 1:4:8 bed, plastering with neat cement finish, Medium
duty CI cover with frame etc. complete.
Septic tanks of larger capacity may be made utilising different items as components, measured and paid accordingly as per relevant item specifications
and rates.
247 POINT WIRING FOR LIGHT/FAN WITH PLATE SWITCHES ANCHOR ROMA/MK/FINOLEX/HAVELLS-CRABTREE / SSK Providing and laying point
wiring in concealed conduits for the following points using specified 1100V grade PVC insulated, FRLS multistranded 3 x 1.5 sqmm copper conductor
wires. Rate to include supplying, laying and securing in position in roof slabs and brick walls or concrete columns 25 mm dia medium duty rigid PVC
conduits (Conforming to IS 9537:Part 3: 1983) of approved make with necessary accessories and junction boxes/pull boxes. Providing and fixing in
the brick walls flush type metal switch boxes of approved make shade and sufficient size to accommodate all 6A Modular switches / 3 pin socket,
screws, holders. ceiling roses and the fan regulator wherever required.
Rate to include wall chasing and rough plastering. Providing and fixing single pole 5A modular plate switches of ANCHOR
ROMA/MK/FINOLEX/HAVELL-CRABTREE/SSK make of approved colour . One switch shall be provided for each light and fan point. Rate to include
providing main circuit wiring from DB to switch boards with 2.5 sqmm copper wires. All wires shall be conforming to IS 694:1990.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 22 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
257 FRLS MULTISTR. 1.5 SQMM COPPER Running
Metre
Supply and laying through conduit FRLS multistranded PVC insulated (1100V) copper wire conforming to IS 694:1990 and of size 1.5 sqmm including
termination etc. all complete. PVC Conduits to be paid for separately as per relevant items.
Supply, installation and commissioning of 63A TPN MCB DB Incomer : 1 no 63 A , 4 Pole MCB Outgoing : 18 nos, 10A/16A/20A SP MCBs
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 23 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
278 DECORATIVE LUMINAIRE-AMA-1X18W Each
Same as item no.269 but Decorative luminaire with lamp reflector, opal/clear receded acrylic cover Arcade make. 1X18W
FLR.MNT.PANELBOARD-2X125/2X63A Each
288 Supply and erection, testing commissioning of floor mounting type cubical panel board made out of 16 SWG CRCA sheet steel with 200 A TPN copper
bus bars, interconnections, earthing, powder coating and comprising of the followings as required.
Incomer : 2 nos 125A TP switch fuse unit with HRC fuses for DG and EB 1 no 125A 4 pole change over switch 2 no volt meter with volt meter selector
switch, 2 no ammeter with C T & ammeter selector switch, 2 sets of Phase indicating lamp (RYB) Outgoing : 2 nos 63A and 3 nos 32A TP fuse switch
unit with HRC fuse.
290 Design, fabrication, supply, installation, testing and commissioning of factory made LT switch board/ panel of Make - HENSEL made out of
polycarbonate, polyestrene thermoplastic modules/enclosure with IP 65 degree of protection. Please refer to attched specifications, list of items, bill of
materials and drawing nos. HENMIPDB31705 for details. Approved Equivalent - Fibox, Rittal
Bus Bar Rating: 250 A (12x10, 12x5 mm Cu), System Voltage: 415 V, 50 Hz
Incomer: 125A FP COS - 1No.; 100A TPN SFU - 1No.; 70A Contactor - 1No.
Outgoings: 32A FP ISOLATOR - 1 No.; 32A FP MCB - 2 Nos.; 20A DP MCB - 2 Nos.; 32A DP MCB - 14 Nos.; 10A DP MCB - 17 Nos.; 40A FP ISO -
1 No.
Metering: Voltmeter with selector switch (0-500V) - 1 No.; Ammeter with selector switch (0-63A) - 1 No.; Frequency Meter - 1 No.; Current
Transformer(63/5A) - 3 Nos.; R/Y/B LED Indication - each 1 No.; On/Off PB - each - 1 no.; Control Fuse with Base - 6 Nos.
Terminals: 50 Sqmm Feed in Terminals - 10 Nos.; 6 Sqmm - 85 Nos.; 4 Sqmm Earth Terminals - 35 Nos. Rate to include approved front cable cover,
pedestal frame with FRP lining and canopy as per manufacturer's specifications.
Note: For any outlet having requirement of more than 25 KVA load, the panel has to be separately designed using the above basic material of
approved manufacturers. The payment shall be made separately basis the original quotation received from manufacturer and approved by HPCL
Engg.-in-Charge.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 24 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
292 S/L 3.5CX120SQMM ARMD.AL CABLE Running
Metre
Same as Item No.290 but 3.5CX120 sqmm AL cable.
293 S/L 3.5CX95 SQMM ARMD.AL CABLE Running
Metre
Same as Item No.290 but 3.5CX95 sqmm AL cable.
294 S/L 3.5CX70SQMM ARMD.AL CABLE Running
Metre
Same as Item No.290 but 3.5CX70 sqmm AL cable.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 25 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
309 S/L 3CX6 SQMM UNARMD. CU CABLE Running
Metre
Same as Item No.290 but 3Cx6 sqmm unarmoured copper cable
310 S/L 4CX6 SQMM UNARMD. CU CABLE Running
Metre
Same as Item No.290 but 4Cx6 sqmm unarmoured copper cable
311 S/L 2CX4 SQMM UNARMD. CU CABLE Running
Metre
Same as Item No.290 but 2Cx4 sqmm unarmoured copper cable
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 26 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
331 WELDING CABLE 16 SQMM COPPER Running
Metre
Supply/laying/fixing welding cable 16 sqmm of rating 174 A and conforming to IS 9857:1990 having gasoline resistant insulation and multistranded
copper conductors. Rate includes end terminations, sockets and thimbles complete.
Supply and laying 100 mm dia GI pipe of approved make conforming to IS 1239 medium duty including threading, suitable GI collars, bends, elbow,
nipples etc. all complete.
Foundation RCC 1:1.5:3 shall be of size 550x550mm and depth 1200 mm with 8 nos. 12mm dia. tor bars as main bars and 8mm dia. tor bars stirrups
@ 190 mm c/c as per approved drawing. This reinforcement shall conform to IS:1786 latest edition. The foundation shall extend above sorrounding
ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing. Excavation, PCC,
RCC and reinforcement shall be done and paid extra as per relevant items.
Foundation RCC 1:1.5:3 shall be of size 550x550mm and depth 1200 mm with 8 nos. 12mm dia. tor bars as main bars and 8mm dia. tor bars stirrups
@ 190 mm c/c as per approved drawing. This reinforcement shall conform to IS:1786 latest edition. The foundation shall extend above sorrounding
ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing. Excavation, RCC
and reinforcement shall be done and paid extra as per relevant items.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 27 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
Supply and installation of BAJAJ make Hot dip galavanised iron pole wall thickness 3 mm. C/s A/F - top = 70mm, bottom =130 mm, base plate
220x220x12 mm, 500 mm long weatherproof reinforced door opening with junction box mounting arrangement but exclusive of junction box, singler
arm bracket 1 m, 20 dia threaded made to J shape and having 600 mm total length steel grade EN8 foundation bolts - 4 nos with nuts, templates and
all complete as per approved drawing. Approved Equivalent Make - PHILIPS.
Foundation RCC 1:1.5:3 shall be of size 550x550mm and depth 1400 mm with 8 nos. 12mm dia. tor bars as main bars and 8mm dia. tor bars stirrups
@ 190 mm c/c as per approved drawing. This reinforcement shall conform to IS:1786 latest edition. The foundation shall extend above sorrounding
ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing. Excavation, RCC
and reinforcement shall be done and paid extra as per relevant items.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 28 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
343 GI Oct.Light Pole-DoubleArm 7m Each 19600
Supply and installation of BAJAJ make Hot dip galavanised iron pole wall thickness 3 mm. C/s A/F - top = 70mm, bottom =130 mm, base plate
220x220x12 mm, 500 mm long weatherproof reinforced door opening with junction box mounting arrangement but exclusive of junction box, double
arm brackets 1 m each, 20mm dia. threaded made to J shape 700 mm long steel grade EN8 foundation bolts - 4 nos with nuts, templates and all
complete as per approved drawing. Approved Equivalent Make - PHILIPS.
Foundation RCC 1:1.5:3 shall be of size 550x550mm and depth 1400 mm with 8 nos. 12mm dia. tor bars as main bars and 8mm dia. tor bars stirrups
@ 190 mm c/c as per approved drawing. This reinforcement shall conform to IS:1786 latest edition. The foundation shall extend above sorrounding
ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing. Excavation, RCC
and reinforcement shall be done and paid extra as per relevant items.
Foundation RCC 1:1.5:3 shall be of size 550x550mm and depth 1500 mm with 8 nos. 12mm dia. tor bars as main bars and 8mm dia. tor bars stirrups
@ 190 mm c/c as per approved drawing. This reinforcement shall conform to IS:1786 latest edition. The foundation shall extend above sorrounding
ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing. Excavation, PCC,
RCC and reinforcement shall be done and paid extra as per relevant items.
Foundation RCC 1:1.5:3 shall be of size 550x550mm and depth 1500 mm with 8 nos. 12mm dia. tor bars as main bars and 8mm dia. tor bars stirrups
@ 190 mm c/c as per approved drawing. This reinforcement shall conform to IS:1786 latest edition. The foundation shall extend above sorrounding
ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing. Excavation, RCC
and reinforcement shall be done and paid extra as per relevant items.
349 Providing plate electrode earthing as per IS 3043 and attached drawing including excavation of depth 3.2 m, supplying and fixing plate electrode of
size 600x600 mm and thickness 6.3 mm (GI) or 3.15 mm (Copper), 50mm dia GI pipe of heavy duty (wall thickness 4.5 mm) with funnel for watering,
wire mesh, GI flat (2 nos. 50x6 mm ) collars, two connecting GI strips (50x6 mm) from plate electrode to collar, fixing & using using GI nut bolts with
bitumen coating and welding as per drawing, filling the pit with alternate layers of charcoal and salt, back filling, constructing 230 mm thick Brick
Masonry chamber 1000(length)x500(width)x600 (depth) mm internal size with plastering 10 mm thick and embedded 50 mm dia PVC conduit
openings at two places packed with jute soaked in bitumen at the entrances, 100mm thick PCC 1:3:6 at the bottom of chamber, providing 3 mm thick
MS sheet cover with diagonal bracings of 25x3 mm flats, frame and hinge arrangement covering full opening, grouting the cover frame in PCC 1:2:4
bed 230x75 mm, painting two coats of approved colour synthetic enamel paint over a coat of red oxide primer etc. complete.
Rate includes carrying out earth resistance testing of the earth pit provided, submitting report and painting resistance, test date and pit identification no.
on cover top.
350 EARTH PIT-PLT ELEC.W/O CHAMBER Each
Earthing Pit-Plate Electrode without chamber:Same as item no. 348 but without chamber and covers. The item is for providing earthing pit under
driveway. The chamber and cover shall be provided with same specifications as of driveway chambers and as per instructions of Engg.-In-Charge. The
driveway chambers shall be paid as per respective item rate.
351 Providing pipe electrode earthing as per IS 3043 and attached drawing including excavation of depth 3.75 m, supplying and fixing pipe electrode of
size 50 mm dia heavy duty (wall thickness 4.5 mm) GI pipe with funnel for wateing, wire mesh, GI flat (50x6 mm) collar joined to pipe using 50x6 mm
strip and GI nut bolts with bitumen coating as per drawing, filling the pit with alternate layers of charcoal and salt, back filling, constructing 230 mm thick
Brick Masonry chamber 400(length)x400(width)x400 (depth) mm internal size with plastering 10 mm thick and embedded 50 mm dia PVC conduit
openings at two places packed with jute soaked in bitumen at the entrances, 100mm thick PCC 1:3:6 at the bottom of chamber, providing CI cover with
CI frame in hinge arrangement covering full opening, grouting the cover frame in PCC 1:2:4 bed 230x75 mm, painting two coats of approved colour
synthetic enamel paint over a coat of red oxide primer etc. complete.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 29 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
Rate includes carrying out earth resistance testing of the earth pit provided, submitting report and painting resistance, test date and pit identification no.
on cover top.
352 EARTH PIT-PIPE ELEC.W/O CHMBER Each
Earthing Pit-Pipe Electrode without chamber:Same as item no. 348 but without chamber and covers. The item is for providing earthing pit under
driveway. The chamber and cover shall be provided with same specifications as of driveway chambers and as per instructions of Engg.-In-Charge. The
driveway chambers shall be paid as per respective item rate.
Supply , installation and commissioning of 3 phase oil cooled balanced / unbalanced load servo controlled voltage stabilisers (Make - Logicstat / Blue
bird / Bhurji / HPCL approved make) including auto / manual control, overload trip relay, low / high voltage cut-off, single phase protector, cost of oil.
Rate includes making input and output connection but excludes supply of necessary cables, lugs and clamping. Party to furnish manufacturer's test
certificate alongwith supply and provide warranty/gaurantte for a period of one from the date of installation..
360 3 PHASE SERVO STABILISER-25KVA Each
361 3 PHASE SERVO STABILISER-40KVA Each
Supply , installation and commissioning of 3 phase air cooled balanced / unbalanced load servo controlled voltage stabilisers (Make - Logicstat / Blue
bird / Bhurji / HPCL approved make) including auto / manual control, overload trip relay, low / high voltage cut-off, single phase protector. Rate includes
making input and output connection but excludes supply of necessary cables, lugs and clamping. Party to furnish manufacturer's test certificate
alongwith supply and provide warranty/gaurantte for a period of one from the date of installation.
362 5/6 KVA Each
363 9/10 KVA Each
364 15KVA Each
365 20 KVA Each
Supply , installation and commissioning of single phase voltage stabilisers (range 160V - 260V) of approved Make - Logicstat / Blue bird / Bhurji /
HPCL approved make. Rate includes overload trip relay, low / high voltage cut-off, Rate also includes making input and output connection but excludes
supply of necessary cables, lugs and clamping. Party to furnish manufacturer's test certificate alongwith supply and provide warranty/gaurantte for a
period of one from the date of installation.
366 2 KVA Each
367 5 KVA Each
368 7.5 KVA Each
369 10 KVA Each
Supply and fixing of constant voltage transformer of aproved make - Logicstat, Blue bird, Sukam, Bhurji or equivalent. Party to furnish manufacturer's
test certificate alongwith supply and provide warranty/gaurantte for a period of one from the date of installation.
370 100 VA CVT Each
371 250 VA CVT Each
372 500 VA CVT Each
373 TANK INSTALLATION-70KL Each
Installation of HPCL supplied Tanks of 70 KL capacity in earth pit /brick masonry pit. Job includes Hydrostatic testing to pressure of 3.5m water
column, supplying & filling with water with necessary 50 mm dia pipe & on successful completion emptying out the water from tank , cleaning & drying
the inner surfaces with cloth/ cotton waste etc., doping with two coats tank mastic paint of STP make and hot 30/40 bitumen ( total doping thickness
3mm) ,fixing all fittings etc.
Job excludes excavation, PCC, RCC, BM, plastering, which shall be paid seperately as per drawing and actual measurement at site as approved by
Engg.-In-Charge. cost of fittings, cost of pipelines, check valves shall be paid separately on actual basis. Rate to include providing and fixing locking /
caping arrangement in all fill pipes / suction pipes / dip pipe etc. as directed by Engg.-In-Charge.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 30 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
Same as item no. 370 but for 45 KL tank
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 31 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
394 GRANITE TILE-10MM THICK Square
Metres
Providing and fixing 10 mm thick pre polished water cut black granite tiles for pump island dado including providing 12mm thick bed cement mortar 1:4
(1 cement : 4 coarse sand) , fixing the tiles with neat cement paste and finishing the joints with white cement mixed with matching colour pigment.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 32 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
397 PRECAST RCC COVER: CLASS AAA Square
Metres
Providing and laying factory made pre-cast RCC (Concrete Grade – MINIMUM M35) covers with MS lifting lugs of Surabh / KK manhole make or
equivalent meeting the specifications, having thickness 90 mm and size to cover the pipeline trench. The cover shall be suitable for AAA class load
(Minimum 35 MT rolling axle load) and shall have MS enclosure of minimum 2 mm thick allaround including reinforcement suitable for load class. The
clear opening span of trench shall not be more than 650 mm
Dismantling of Cement concrete : above plinth level only. For works below plinth excavation shall be paid separately.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 33 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
Dismantling of RCC with pneumatic drill / Jack hammer : Above plinth level only. For masonary below plinth excavation shall be paid separately.
Dismantling of ceramic tiles of any thickness. Scope of job includes cleaning the bed post dismantling to make it fully prepared for fresh tiling/ flooring.
TRANSPORTATION WORKS
Loading / Unloading with countable stacking and transporting from one location to another, corporation supplied Engineering material ike CC paver
blocks/ yard light poles/ signage/ steel plates etc of all sizes excluding tanks, DUs light fixtures. Rate includes all enroute taxes but excludes octroi, if
any, on corporation material..
Mini truck load upto 4MT
422 0-50kms Lump Sum
423 Beyond 50kms Kilometers
424 Detention charges Days
Full Truck load -upto 10MT
425 0-50kms Lump Sum
426 Beyond 50kms Kilometers
427 Detention charges Days
Trailor load upto-20MT
428 0-50kms Lump Sum
429 Beyond 50kms Kilometers
430 Detention charges Days
Transportation from one location to another, corporation supplied Mono pump / Dual pup / MPD / Air compressor / Light fixtures all other pumps etc in
mini truck load upto 4MT (per trip load) . Rate includes all enroute taxes but excludes octroi if any on corporation material.
431 0-50kms Lump Sum
432 Beyond 50kms Kilometers
Transportation from one location to another, corporation supplied Mono pump / Dual pup / MPD / Air compressor / Light fixtures all other pumps etc in
truck load upto 10 MT (per trip load) . Rate includes all enroute taxes but excludes octroi if any on corporation material..
433 0-50kms Lump Sum
434 Beyond 50kms Kilometers
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 34 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
435 LOADING/UNLOADING OF MONO Dus Each
Loading / Unloading in / from Mini truck / truck & stacking of mono / Dual pump / Air compressor with fittings upto 3HP / all other pumps upto 3HP.
LOADING/UNLOADING OF MPD
Loading / Unloading in / from Mini truck / truck & stacking of MPD DU / All other compressor & pump with fittings above 3HP.
436 Upto 1 No pump Each
437 Over & above 1 No. Each
438 PVC PIPE 6",IS:4985, 6KG/SQCM Running
Metre
Providing and fixing 6" dia PVC pipes of 6 Kg/sqcm of Prince Make or equivalent make as per IS 4985 for rain water pipes including all fittings like
bands , shoes etc., MS fabricated bracket as per requirement etc. All complete as directed by the Engg.-In-Charge.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 35 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
455 CANOPY - ROOFING & GUTTER Square
Metres
CANOPY ROOFING & GUTTER Supply, providing & installation of all Roofing, flashing, capping, trims, gutters etc. all complete.- Refer Sections 3.B.1
TO 3.B.3 of attached specifications. Section 3.B.4 to be referred for downtake assembly specifications to be fixed with roofing/gutter system - to be
paid extra as per relevant item.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 36 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
459 CANOPY-LUMINAIRE 150W SYMTRC. Each
LUMINAIRES WITH LAMP Supply and installation of Philips make metal halide fixture Cat. MPF 922 150 suitable for symmetric use with 150 W MHN
TD metal halide lamps, chokes, control gears etc. all complete. Approved Equivalent - Bajaj, Crompton. Job includes supplying & fixing of MCBs for
proper electrification of all lights on canopy, etc. all complete - Refer Section (3.C.1).
Supply & fixing of approved colour/make/model CFL light fixtures in canopy false ceiling in existing cut or after cutting neatly the false ceiling. The fitting
will be hanged from the canopy framing using sturdy GI wires. Rate to be inclusive of terminations and making operational etc. complete. Canopy
luminaire suitable for 3X36W CFL consisting of Electronic ballast having total Harmonic distortion less than 10%,having IP 65 protection from bottom,
re-lamping through hingeable front cover and with 3 nos 36 W CFL lamps. Specification
• Epoxy white powder coated CRCA sheet steel housing
• Electrochemically brightened, polished and anodised aluminium reflector
• Control gear and new generation accessories with < 10 % THD electronic ballasts mounted on removable gear tray and pre-wired up to terminal
block
• Clear Toughened glass is sealed with bottom frame & specially developed non-hygroscopic gasket to ensure foolproof dust/ particle protection.
Maintenance from front side
• Re-lamping through hingeable front cover
• Hardware S.S
• Degree of Protection: IP65 (from Bottom). Approved make: Bajaj, Cat Ref: BPRF 336 C LHD TG. Approved equivalent: Philips/Crompton
Structurals shall be painted after brush cleaning all rusts, scales, splatters etc. Approved Paint System - First Coat in Shop: Epoxy Zinc Phosphate
primer - 30 micron (Epilux 13HB make Berger or equivalent); Second Coat at site before erection: Epoxy Zinc Phosphate primer - 30 micron (Epilux
13HB make Berger or equivalent); Third Coat after erection and touchup: Synthetic enamel paint - 30 micron (Torpedo Synthetic enamel –make Berger
or Equivalent make ) Final Coat of Approved Colour: synthetic enamel paint - 30 micron (Torpedo Synthetic enamel –make Berger or Equivalent
make ). Total thickness (DFT) of painting - 120 micron. The contractor shall provide Elcometer and all assistance for checking DFT at different stages
by HPCL and records will be maintained. Necessary rectifications as advised shall be done by the contractor without extra cost. Only theoretical
weights of MS plates/ rolled sections/ foundation bolts shall be taken for payment purpose with exclusion of nuts, bolts, welding etc.
Structurals shall be painted after brush cleaning all rusts, scales, splatters etc. Approved Paint System - First Coat in Shop: Epoxy Zinc Phosphate
primer - 30 micron (Epilux 13HB make Berger or equivalent); Second Coat at site before erection: Epoxy Zinc Phosphate primer - 30 micron (Epilux
13HB make Berger or equivalent); Third Coat after erection and touchup: Synthetic enamel paint - 30 micron (Torpedo Synthetic enamel –make Berger
or Equivalent make ) Final Coat of Approved Colour: synthetic enamel paint - 30 micron (Torpedo Synthetic enamel –make Berger or Equivalent
make ). Total thickness (DFT) of painting - 120 micron. The contractor shall provide Elcometer and all assistance for checking DFT at different stages
by HPCL and records will be maintained. Necessary rectifications as advised shall be done by the contractor without extra cost. Only theoretical
weights of MS plates/ rolled sections/ foundation bolts shall be taken for payment purpose with exclusion of nuts, bolts, welding etc. Luminares and
electricals will be done and paid separately as per relevant items.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 37 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
Same as item no.459 but for supply, fabrication and fixing including tack welding fresh and warp/defect free MS sheets of approved gauge and Make -
Tata, SAIL, Vizag, Jindal or Essar. Fabrication and arrangement drawing of sheet pieces showing dimensions of individual pieces shall be developed
by the contarctor without extra cost and submitted to HPCL for approval. The work shall be carried out strictly as per such approved drawing.
Discretion of HPCL Engg.-in-Charge shall be final and binding on the contractor regarding dimensions of the MS sheet pieces to be used. The rate
also includes painting the MS sheets on front with two coats of red oxide primer after cleaning with wire brush, sand paper and cloth. Backside of the
sheets will be painted same as per specifications for Hoarding MS structurals (Item No. 400). Only theoretical weights of MS sheets shall be taken for
payment purpose with exclusion of nuts, bolts, welding etc.
3. For all steel structuals job including canopy/ Pergola/ Hoardings, manhole covers, trenches etc. all the rolled sections as well as the MS
plates used shall be of first quality and should be factory fresh. Under no circumstances the steel used shall be of scrap, second quality,
rusted, pitted, of second use etc. The corners, edges, cutting, welding etc. shall be properly cleaned and grinded so that there are no sharp
edges, corners, cut marks, weld splatter etc. in finish material.
Disposal of surplus earth within / outside HPCL premises to any unobjectionable place all complete as per direction of Engg.-In-Charge.
Note: For all cutting/excavation and filling jobs, it will be the responsibility and duty of the contractor to take joint initial levels with Engg.-In-Charge in
all cases before commencing the work. The joint levels should be certified by the contractor as well as HPCL Engg.-In-Charge. The payments will be
made basis the initial levels and final levels taken jointly and certified. The payment for all cutting / excavation will be made at the lower rate applicable
for 0 to 3 m and the higher rate will be paid only for the portion beyond 3 m depth. If the contractor fails to take jointly certified levels, the levels as
taken by HPCL Engg.-In-Charge shall be treated as final and all payments will be released basis the levels so taken by the HPCL Engg.-In-Charge.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 38 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
PCC WORK : Providing and laying PCC using graded stone aggregate of using 20 mm and down size graded stone aggregates. The job includes
machine mixing, providing formwork, MS/ plywood (minimum 19 mm thick) shuttering if directed by Engg.-In-Charge, placing, compacting by hand
ramming , curing for a period of 14 days etc, all complete as per direction of Engg.-In-Charge. Removing of shuttering to be done carefully without such
shock and vibration as to damage the PCC work.
Rate also to include carrying out the following tests on aggregates and test result to be submitted to Engg.-In-Charge before use and shall meet the
following strength requirements. LA Abrasion value = 40%, Flakiness index = 15%.
The macadam course shall be laid in two layers of around equal thickness, each layer shall be rolled and compacted. Tack coat shall be
applied between the two layers@ 9.8 kg per 10 sqm.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 39 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
485 SEMI DENSE BITUMIN. CONCR.25mm Square
Metres
SEMI DENSE BITUMINOUS CONCRETE (25 mm Thick) : Providing and laying 25 mm thick semi dense bituminous concrete on prepared surface with
good quality graded stone aggregate as per following requirement -Material 5euired per 100 Square meter Crushed stone aggregate of 13.2 mm size =
1.0 CUM , 11.2 mm size -1.6 CUM , Fine aggregate 6 mm size - 1.1 CUM Bitumen 60/70 grade including tack coat = 330 Kg .The job includes hot
mixing of aggregate and bitumen by using hot mix plant transportation mixed material and laying the same , rolling with 8 to 10 Ton power roller to
uniform consolidated compacted thickness of 25 mm over a tack coat of 2.0 Kg per 10 Square meter to achieve the required level and grade all
material, labour etc complete.
Rate shall also include providing approved quality minimum 20micron thick polythene paper below the driveway, hardener as per manufacturer's
recommendation for heavy traffic driveway adding plasticiser as per manufacturer recommendation, of Roffe / CICO equivalent approved make. Job
also includes constructing horizontal and longitudinal vatas with 1:10 CM for curing, leveling depressions if any in the base with 20mm stone
aggregates and coarse sand.
Proper slope to be provided in driveway for easy draining of rain water. Reduced level of the driveway area to be taken jointly with architect before
commencement of concreting and after concreting and the thickness of RCC to be checked. Testing of cube, reinforcement steel, stone aggregates,
sand, cement etc. to be carried out by contractor at no extra cost. Tubing, ducting, trenching and other necessary embedded items in concrete shall be
checked with architect / HPCL representative before concreting.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 40 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
492 THERMOPLASTIC ROAD MARKING Square
Metres
Supplying and applying Berger make Sigmark thermoplastic road marking paint as per MORTH specifications 803.4. The work shall be carried out
strictly in line with maufacturer's procedures and using specified materials, tools, heating device/apparatus and machinery etc. all complete. The briefs
of materials are as following:
(i) Hot Melt Thermoplatic Road Marking Compound: 5 kg/sqm
(ii) Glass Beads: 250 gm /sqm
The drying time should be within 5 minutes and dry coat thickness to be 2.5 mm.
Rate shall be inclusive of all material, labour, tools & tackles, power, heating apparatus etc. all complete. Work shall be carried out ensuring safety at
outlet and as per approved drawing and plan.
The fitting will be done on brick masonry/concrete walls as per manufacturer specified procedures and approved nails/fixtures in line and level as per
advice of Engg.-in-Charge (EIC). Powder coated MS angle edge protection shall be provided to make it theft resistant. Measurement and payment
shall for per no. of 33inch long and 4" wide LDS provided as per EIC advice.
The vendor shall furnish 5 years repalcement guarantee on Rs.100/- stamp paper against defects, damage under vehicular traffic, wear and tear etc.
from the completion date. HPCL descrition shall be final and binding on the vendor.
496 PREMIX CARPET-50 MM Square
Metres
Providing and laying premix carpet 50 mm thick ( Consolidated) with coarse aggregate of nominal size 12.5 mm ( two part ) and 10 mm ( one part) .
Quantity of bitumen (80/100 grade) used should be 36.5 Kg per 10 sqm for premix and 7.5 kg per 10 sqm for tack coat. Surface preparation by
cleaning with wire brush, removing the dust etc before applying tack coat. The job includes compaction by 8 to 10 Ton roller to proper camber and
slope all complete as per direction of Engg.-In-Charge.
NOTE : All the asphalting jobs shall be started only after stacking bitumen at the site as per theoretical calculation considering the area.
The total job including seal coat to be carried out in one go. In case of any delay in laying the seal coat after laying the premix carpet,
additional tack coat @ 5.0 Kg per 10 sqm to be laid without any extra payment.
Square
499 RELAYING OF PAVERS Metres
Laying of HPCL supplied pavers in line and level , as per attached specifications. The job includes supplying and laying sand bedding, compacting
using plate vibrator, all material and labour complete. Pavers will be laid at 45 degree to road line in 1 red and 2 grey arrangement. Plan of laying will
be developed by the contractor and prior approval of EIC will be taken before commencement of laying..
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 41 of 43
SPECIFICATION FOR CIVIL WORK
S.NO DESCRIPTION UNIT RATE
500 S/L DRIVEWAY PAVERS-80MM (M50 AS PER IS15858,2006) Square
Metres
Supply and laying of 80mm thick grey / coloured pavers in line and level and approved pattern and shape, as per attached specifications. The job
includes supplying and laying sand bedding, compacting using plate vibrator, all material and labour complete. Pavers will be laid at 45 degree to road
line in 1 red and 2 grey arrangement. Plan of laying will be developed by the contractor and prior approval of EIC will be taken before commencement
of laying. The pavers supplied should of M50 type and should conform to IS:15658:2006. The party shall have to produce manufacturer's certification
on the paver qualifying criteria stated in IS-15658, before the pavers are sited. HPCL reserves the right to do random sampling and testing as per IS-
15658:2006 to assess manufacturer's certification on qualifying norms specified in the attached specification. The testing charges, if samples qualify,
shall be borne by HPCL, else shall be borne by the party.
Vendor's Seal & Signature Eff. Date:15-09-06::Rates valid for 2006-07 Page 42 of 43
SCHEDULE OF RATES FOR MODERNISATION / CONSTRUCTION OF RETAIL OUTLETS UNDER NORTH ZONE
NOTES:
1 Quoted rate shall be applicable for any height, depth, level and thickness of wall etc unless otherwise
specified.
2 Samples of all materials will have to be approved by Engg.-In-Charge before using the same.
3 All IS Codes referred to shall be of Latest Edition only.
4 List of approved make/brand is attached to technical/commercial bid and decision of HPCL with
regard to selection of make/brand of material to be used shall be final.
5 All jobs to be carried out as per technical specification attached to technical/commercial bid.
6 For all cutting/excavation and filling jobs, it will be the responsibility and duty of the contractor to take
joint initial levels with Engg.-In-Charge in all cases before commencing the work.The joint levels
should be certified by the contractor as well as HPCL Engg.-In-Charge.The payments will be made
basis the initial levels and final levels taken jointly and certified. The pay-ment for all cutting /
excavation will be made at the lower rate applicable for 0 to 3 m and the higher rate will be paid only
for the portion beyond 3 m depth.If the contractor fails to take jointly certified levels, the levels as taken
by HPCL Engg.-In-Charge shall be treated as final and all payments will be released basis the levels
so taken by the HPCL Engg.-In-Charge.
3.102316
7 Purchase proof of any material may be asked by HPCL from the contractors. HPCL reserves right to
approach to original manufacturers, authorised dealers/resellers or any other agency/laboratory for
verification of quality/purchase of materials and documents submitted by contractor. Appropriate penal
action will be taken against the contractor found defaulting including deductions of amount whole or in
part as per discretion of HPCL and also may result in removal of name of the contractor from approved
vendors list of HPCL.