You are on page 1of 13

85,000 lb/h of Oil will be cooled from 175◦F to 125◦Fby

Liquido Hot. Oil Inlet pressures are 45 psia for the acetate and 50 psia f
Liquido Cold. Isobutano specified for each stream.

Isobutano Oil
cp 0.44 0.53
u 0.6 3.12
k 0.079 0.068
p 42.75 50.5

Media Delta T Factor de correccion


ΔT1 55 R
ΔT2 50 P
ΔTln 52.5
R diferente A 1
alfa 0.90909091
s
F

Heuristicas
Tubos Isobutano
Fluidos
Coraza oil
Do In 1 0.083333333333333 ft
BWG (Espeso)r 0.065 0.005416666666667 ft
Di in 0.87 0.0725 ft
L ft 19
pt 1.25 Triangular
Material de construccion.
Heuristica Shell
K btu/ft*F*h 40 Acero cromado
N 1
Pasos por los tubos Diametro de la coraza
np= 6 PoS
Tabla C
Re 73174.686479 Re>10 Ala 4 ds in
V ft/s 3.9349162589 3,8 ft/s #tubos 212

Con D tube= 1
Ureq 36.028393846 C= 0.25
Para tubos De 0.72
Pr 3.3417721519 coraza h
Nu 259.72330621 B/ds 0.3
Re 70413.377555 B 7.5
H 283.00884401 as 0.26041667
G 243876.226
De 0.0825
Re 6448.65022
jh 22.780309
Pr 24.3176471
Ulimpio 44.268731973 ho 54.3986879
ill be cooled from 175◦F to 125◦Fby heating a stream of Isobutanol from 75◦F to 120◦F.
45 psia for the acetate and 50 psia for the alcohol. A maximum pressure drop of 7 psi is
ream.

Isobutano Tubos Oil Coraza


T1 75 T1 175
T2 120 T2 125
Alimenta 85000 Alimentacion 63509.434

Factor de correccion
1.11111111 1 N
0.45

R diferente A 1 R=1
0.90909091 S 0.45
0.45 F 0.8762
0.84440425

U 37.5
A 1013.14527
Tubos 203.68052

25 in

Tp= 1.25 fix triangular


Figura
Figura

oraza h Calculo de U con factor de ensuciamiento.


Factor de ensuciamiento Ud 38.6276998
Rdi 0.002
ft2 Rdo 0.001
lb/h*ft2
ft Ud/Ureq 7.214604114706
Referencia; Serth, R. W. (2007).
Process Heat Transfer Principles and
aplications.

Balance de energia
Qh 1683000

Calculos externos
2-s(2-raiz(2)) 1.7363961
2-s(2+raiz(2)) 0.4636039

2-s(R+1-Raiz(Potencia(R;2)+1)) 1.7226812
2-s(R+1+Raiz(Potencia(R;2)+1)) 0.3773188
Raiz(Potencia(R;2)+1*ln(1-s/1-R*S) 0.14247415

204
Formulas y tablas.
Tablas y graficas

You might also like