Ensure that all spaces which to be fumigated are cleaned and disinfected as per SOP
Clean up of Aseptic Area
Take the required quantity of 40% commercial formalin (as mentioned in the table) in
S. S vessel for each room
Add distilled water (25% of the volume of formalin) to make stock solution for
fumigation
Let the fumigation be started by switching ON the electric heater and switching OFF
when the stock solution is completely evaporated
Lock the aseptic area. & Hang the notice that areas are fumigated
TIME OF FUMIGATION:
After cleaning of aseptic area
Take the required quantity of 40 % formalin according to the prescription and add 25 % distilled water to make the stock
solution.
2.5
1 cft require = mg of Formaldehyde
0.03531466
2.5 x V
V cft require = mg of Formaldehyde (Where V = Volume of space to be fumigated).
0.03531466
= 70.792V mg = 0.070792V gm
100
1 gm ,, ,,
40 ml Commercial formalin
100 x 0.070792V
0.070792V gm ,, ,,
ml Commercial formalin
40
= 0.17698V ml commercial formalin