You are on page 1of 13

KA-TET

COMPANY PRESENTATION
WHO WE ARE?

KA-TET GROUP - is an international company that specializes in two industrial directions as manufacturing of filters and chokes
technology, and outsource engineering. KA-TET high-tech products are successfully implemented in various industry sectors
namely heavy industry, energy, and oil production. Our Engineering services are widely used within the thermal systems’
design, aerodynamic and strength tests.
KA-TET team of experts is always ready to provide you with the solution to increase your efficiency level and solve the most
challenging tasks.
Our manufactured products find their place all around the world. KA-TET solutions are effectively operating in Turkey, Saudi
Arabia, Oman, Iraq, Ukraine.

COMPANY IN NUMBERS
YEAR OF ESTABLICHING: 2018 EXPERIENCE IN OIL & GAS: +8 YEARS PROJECTS: +20
ANNUAL REVENUE: +750,000.00 USD EXPERIENCE IN SOLAR: +5 YEARS CUSTOMERS: +10
NUMBER OF EMPLOYEES: +40 EXPERIENCE IN ENERGY: +15 YEARS COUNTRIES: +5

KA-TET GROUP LLC


UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua
HOW WE LOOK

KA-TET GROUP LLC


UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua
HOW WE LOOK

KA-TET GROUP LLC


UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua
OUR PRODUCTS

CORE PRODUCTS
HARMONIC FILTERS LC FILTERS LINE CHOKES MOTOR CHOKES
Harmonic filters provide a higher LC filters are used to protect the Line chokes are a universal solution Motor chokes are widely used in
suppression of current harmonic. motor insulation, increase their for general industrial applications. AC circuits of variable frequency
It’s a perfect alternative to service life and reduce the motor This chokes type is designed to drive systems. Being installed at
multipulse rectifier circuits that noise level which is powered by a improve the electromagnetic the frequency drive output, motor
results in higher efficiency. In frequency drive. LC filters are compatibility of variable frequency choke protects the drive from
addition, it limits the negative installed at the output of the drives with the supply network. overvoltages impulses and short
effect of the frequency drive on the converter and change the shape of The main responsibilities of the circuits in the load. Depending on
power supply network. the output voltage generated by Line choke are harmonic the drive system, the choke has to
PWM, eliminating the higher protection; protection against perform many tasks as ensuring
harmonics that can cause voltage sags, interference in the continuity and smoothing of motor
additional losses both in the cable network; equipment runlife current pulses, as well as
line and in the motor. increase; power factor increase. suppressing switching overvoltages
and compensating the supply line
KA-TET designs chokes with specific power.
requirements if needed as well.

KA-TET GROUP LLC


UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua
OUR PRODUCTS

HARMONIC FILTERS LP2 SERIES

OFFSHORE APPLICATION WALL MOUNTED FLOOR MOUNTED

KA-TET GROUP LLC


UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua
OUR PRODUCTS

HARMONIC FILTERS LP2 SERIES


≥ 400А
Technical data
KA-TET GROUP company produces
a range of design solutions, which Rated frequency 50Hz 60Hz
Rated voltage 380V 400V 415V 480V
allows you to choose the optimal
solution depending on the Rated current 2..1250A
installation: Overload 110% - continuously 125% - 1 minute
Efficiency > 96,5% for rated power
• floor mounted type THDi < 5% for rated power
• attachable mounted type Capacitance
< 30% Inom
current
Insulation class F(155o C) – standard H(180o C)
By cooling type: ≤ 400А
Operation mode S1 – continuous
• natural air
IP54 IP65
• forced air Enclosure type IP00 IP23 IP43
(NEMA3R) (NEMA4)

Operation
-20..+40 -20..+45 -20..+55 -20..+60
temperature

Cooling method Natural air Forced air

KA-TET GROUP LLC


UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua
OUR PRODUCTS

LC FILTERS MP3 SERIES


MP3 КА-ТЕТ GROUP company filters are used to protect the Technical data
Rated frequency 50Hz 60Hz
insulation of the motor and to increase its reliability. They also
reduce noise level. These filters convert the output voltage signal of
Rated voltage 380V 400V 415V 380V
PWM inverter for sine wave at the same time eliminating the higher
harmonics, which cause additional losses in both the mains cables Rated current 20..1250A
of the motor and in the same motor. Sinusoidal output current and Overload 110% - continuously 125% - 1 minute
voltage of the filter allows for using of considerable lengths of cable PWM 2..16kHz
without the need for shielding and full use of the active power of THDi < 5% for rated power
the drive system. Insulation class F(155o C) – standard H(180o C)
There is a possibility to produce the filter with various coil terminals Operation mode S1 – continuous
like screw terminal blocks, cable lugs or copper bus bars depending IP54 IP65
Enclosure type IP00 IP23 IP43
on the rated current. (NEMA3R) (NEMA4)
It is important to connect the filter properly, since the direct
connection of capacitors to the inverter output may damage the -
Operation temperature -20..+40 -20..+45 -20..+55 20..+
system. 40
If agreed beforehand, it is possible to manufacture filters with
parameters other than those given in the table. Cooling method Natural air Forced air

KA-TET GROUP LLC


UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua
OUR PRODUCTS

LINE CHOKE LP1 SERIES


Type A Type C

Type B Type D

KA-TET GROUP LLC


UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua
OUR PRODUCTS

LINE CHOKE LP1 SERIES


Current Inductance, mH L, мм B, мм L, мм Weight,
3 phase line choke КА-ТЕТ LP1, mostly applied in three-phase power s, А kg
transmission inverter systems. These reactors limit the inrush 2,5 10,100 100 52 122 0,92
3 9,800 100 52 122 0,92
current and restrict a mutually interference of inverters, which are 4 7,300 100 60 122 1,3
supplied from the same transformer. The commutation in systems 6 4,900 125 60 122 1,4
8 3,600 125 61 141 1,8
with motor chokes proceeds softly and overvoltages are 12 2,400 155 71 141 2,4
suppressed. LP1 chokes are simultaneous protective elements 16 1,800 155 77 160 3,4
25 1,200 155 121 130 5,4
limiting the harmonics propagation. 30 0,980 195 110 160 5,9
36 0,820 195 120 160 7,5
Technical data 50 0,600 195 134 160 9,3
Rated frequency 50Hz 60Hz 60 0,500 195 141 180 10,4
Rated voltage 380V 400V 415V 480V 70 0,420 240 157 210 11,8
90 0,330 240 160 210 12,8
Rated current 2..1250A 110 0,270 240 146 210 16,2
Overload 110% - continuously 125% - 1 minute 120 0,250 240 152 210 19,5
Voltage loss 4% 150 0,200 300 161 265 25,0
Insulation class F(155o C) – standard H(180o C) 180 0,160 300 180 225 29,0
220 0,130 300 196 265 36,5
Operation mode S1 – continuous 260 0,110 300 211 265 43,5
IP54 IP65 320 0,092 357 203 310 53,0
Enclosure type IP00 IP23 IP43 (NEMA3 (NEMA4) 400 0,074 420 205 415 57,0
R) 500 0,059 420 215 415 66,0
630 0,047 420 272 415 94,0
Sizes in the table are for typical solution:
700 0,042 480 280 475 104,0
Operation temperature -20..+40 -20..+45 -20..+55 -20..+60 Type - С 800 0,037 480 263 475 122,0
Enclosure type - IP00 900 0,033 480 288 490 128,0
Cooling method Natural air Forced air Temperature range -20..+40С 1000 0,029 480 318 490 155,0
1100 0,027 540 338 535 176,0
1250 0,024 540 350 535 196,0
KA-TET GROUP LLC
UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua
OUR PRODUCTS

MOTOR CHOKE MP1 SERIES2


Type A Type C

Type B Type D

KA-TET GROUP LLC


UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua
OUR PRODUCTS

LINE CHOKE MP2 SERIES


Currents Inductance, mH L, мм B, мм L, мм Weight,
MP2 KA-TET GROUP motor chokes are used in frequency converter ,А kg
circuits. Depending on the type of inverter, MP2 motor chokes 2,5 6,700 100 52 122 1,0
3 5,40 100 60 122 1,2
provide: 4 4,00 100 60 122 1,2
6 2,70 100 60 122 1,3
8 2,00 125 61 140 1,6
• current continuity and smoothing 10 1,70 125 71 140 2,4
• short circuit current limitation 15 1,10 125 71 140 2,6
20 0,80 155 87 165 3,3
• suppression of switching overvoltages 28 0,60 155 87 165 3,6
• compensation line capacity 34 0,48 155 105 165 5,1
40 0,40 195 115 160 5,8
54 0,30 195 130 160 7,5
Technical data 66 0,25 208 112 185 9,3
Rated frequency 50Hz 60Hz 80 0,20 208 130 185 12,5
Rated voltage 380V 400V 415V 480V 100 0,16 240 140 210 14,7
Rated current 2..1250A 110 0,14 240 150 210 17,6
140 0,11 240 165 210 22,5
Overload 110% - continuously 125% - 1 minute
160 0,10 240 170 210 23
PWM 2..16kHz 200 0,08 240 190 210 24
Insulation class F(155o C) – standard H(180o C) 240 0,067 300 180 270 30
Operation mode S1 – continuous 290 0,056 300 210 270 40
IP54 IP65 360 0,045 360 205 315 48
Enclosure type IP00 IP23 IP43 450 0,036 360 220 360 60
(NEMA3R) (NEMA4) 570 0,028 420 265 420 68
Operation Sizes in the table are for typical solution:
650 0,025 420 290 420 80
-20..+40 -20..+45 -20..+55 -20..+60 Type - С
temperature 720 0,022 420 290 420 95
Enclosure type - IP00 810 0,020 540 320 540 140
Cooling method Natural air Forced air
Temperature range -20..+40С 900 0,018 540 350 540 164
1000 0,016 540 360 540 176
1150 0,014 540 360 540 206
KA-TET GROUP LLC
UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua
THANK YOU
FOR ATTENTION

KA-TET GROUP LLC.


UKRAINE, KHARKIV, SUMSKA str. 23, 61057
KA-TET.COM.UA
sales@ka-tet.com.ua

You might also like