Professional Documents
Culture Documents
• Customize legend, grid lines, plot options, etc. Cable Fire Wrap Protection Electro-Magnetic
Transmission Line Motor Circuit Protector
Data Exchange (DataX) Base
Line Ground Conductor Overload Heater
Network Simulation • Legacy program conversion to ETAP
• Unlimited buses (license dependent) & elements • Automatic one-line creation Motor Nameplate Harmonic
• Looped & radial systems • Protective device library mapping Motor CKT Model Interruption Cost
• Automatic error checking • Convert using native file formats
Motor Characteristic Model Reliability
• User interface for all network analysis modules • Database conversion from legacy software
• WMF / EMF / DXF / PDF exporting Motor Load Model Battery
• Customizable ETAP preference properties
• Multi-level user access management • Import RAW / IEEE / CSV files Wind Turbine Generator Control Contact
• Export to AutoCAD® using DXF format Photovoltaic / Solar Panel Control Relay
Built-In Calculators • Import ground grid plans from AutoCAD
Fuse Control Solenoid
• MVA, MW, Mvar, kV, Amp, & PF conversion • Load Ticket for induction machines
• Motor nameplate & dynamic parameter data • Import SKM® project files Recloser Hydraulic GFI / RCD
• Generation nameplate • Import EasyPower® project files Recloser Electronic Controller Distribution Transformer *
• Power grid short circuit impedances
HV Circuit Breaker Train Rolling Stock *
• Motor & generation inertia Report Manager
• Customizable output reports & plots
System Manager • Input, results, alerts, & summary reports
• Project equipment & study summary in one • Reports via Crystal Reports viewer
convenient location • PDF, Microsoft® Word, & Excel reports
• Distribution Load Flow alert summary • Element ID & text search capability Download a Free Demo at
• Switching Optimization summary
• Fault Management summary
• Multi-Language Report etap.com
• Contingency Analysis summary
3
Network Analysis
Network Analysis includes a powerful set of analytical tools that allow for simulation, prediction,
design and planning of system behavior utilizing an intelligent one-line diagram and the flexibility
of a multi-dimensional database. Network Analysis includes Arc Flash, Short Circuit, Load Flow,
Motor Acceleration, and Load Analyzer modules.
Network Analysis
Load Flow Short-Circuit - ANSI / IEEE Motor Acceleration
• Power flow & demand load • ANSI / IEEE C37 Standards • Dynamic motor acceleration
• Voltage drop & power factor correction • IEEE 141 & 399 Standards • Voltage flicker
• Automatic device evaluation • UL® 489 Standard • Motor & load dynamic models
• Automatic temperature correction • Integrates with protective device coordination • Static motor starting
• 2W & 3W transformer LTC / regulator actions • Automatic device evaluation for 3-phase, • Multi-sequence starting
• Real & reactive power losses 1-phase, & panel systems • Conventional starting devices
• Extensive violation alerts • Generator circuit breaker evaluation • Soft starter devices
• Multi-report Result Analyzer • Phase-shifting transformer • VFD frequency control motor starting
• Auto-Run load flow based on system changes • Load terminal short circuit calculation • Load & generation transitioning
• Adaptive Newton-Raphson method • Multi-report Result Analyzer • Motor Operated Valve (MOV) simulation
• Fast convergence for systems with • Comprehensive alarm & warning
negligible impedance Short-Circuit - IEC • Start motor individually or based on groups
• IEC 60909, 60282, 60781, & 60947 Standards
• Consider individual or global bus voltage
Short-Circuit - GOST • Transient fault analysis - IEC 61363 Standard alert limits
• GOST R 52735 Standard • Integrates with protective device coordination
• Calculate periodic & aperiodic components • Automatic device evaluation for 3-phase,
• Consider pre-fault loading condition 1-phase, & panel systems
• Radial & multi-loop circuit calculations • User-definable voltage c factor
• Short circuit output report in Russian language • Load terminal short circuit calculation
• Multi-report Result Analyzer
5
Reliable
6
Integrated
7
Data Exchange
8
ETAP GRID - Distribution
ETAP GRID™ Distribution is an integrated power system simulation, planning, protection, and
real-time distribution management system software for visualizing, managing, optimizing and
automating distribution networks from state-wide to city-wide power distribution networks.
Distribution Systems
System Elements* Time Domain Unbalanced Load Flow* Fault Location, Identification, Isolation &
• Distribution segment & junctions • Loading & generation profile library Service Restoration*
• Distribution feeders, lines & cables • User-defined profile intervals (hr or min) • Identify & locate faults based on waverforms
• Substations & Switching Stations • Create standard profiles such as “8760 profile” • Identify fault types - 3P, LL, LG, LLG, etc.
• Jumper, cut, open point & splice • Seasonal variations including holidays • Predict location based on customer outages
• Distribution transformers – pole, pad & vault • Multi-year load growth • Single or consecutive faults
• Open delta transformer • Mixed customer classes or composite sectors • Identify isolation points based on protective
• Fuse links & fuse cutouts • Simulate daily, monthly or yearly output from device location
• Load break switches PV farm • Restoration based on multiple objectives:
• Switched shunt capacitor banks • Place devices in or out of service during the minimize power losses, minimize overloading,
• Distribution line pole configurations planning period optimize voltage
• Distribution line constants calculation • Plot power generation, consumption, losses, & • Automatically create & test network topology
• Distributed load energy demand for a specified period configuration
• Spot load • Looped & radial systems
• Numerical relays including overcurrent relays
Unbalanced Short Circuit*
& distance relays
• Include prefault loading Voltage Stability*
• Shunt faults – 3PG, 3P, LL, LG, LLG • Sensitivity Analysis
• Multiple generator dynamic models
• Series faults – A,B,C, AB, BC, CA, ABC • Modal Analysis (Eigenvalue Analysis)
• Complete synchronous & induction machine
• Simultaneous fault • PV QV Analysis or Continuation Load Flow
models
• Display phase or sequence results on one-line Analysis
• Comprehensive dynamic load modeling
• Comprehensive excitation system & turbine/ • P-V curves, V-Q curves, dV/dQ self-sensitivities
Switching Optimization* • Eigenvalues, eigenvectors
engine-governor models • Improve system losses
• AC & DC Photovoltaic & inverter modeling • Bus, branch & generator participation factors
• Minimize voltage violations • Minimum distance to instability
• Voltage regulators • Minimize overload
• Phase shifting transformers • Graphical results & plots
• Balance feeder loads
• Multiple types of harmonic filters • Graphically display recommended switching Optimal Capacitor Placement
operations • Optimal location & bank size
Unbalanced Load Flow
• Network summary before & after optimization • Minimize installation & operation costs
• Single-phase & unbalanced 3-phase modeling
• Automatic creation & saving of optimal • Individual source or average energy cost
• Unbalanced & nonlinear load modeling
switching configuration • Voltage & power factor objectives
• Open-delta transformer modeling
• Optimal switch placement • Minimum, maximum, & average loading
• Center-tap transformer modeling
• Branch capacity release & cost savings
• Three 1-phase transformer modeling Single-Phase Distribution • Review capacitor impact on the system
• Isolated sub-systems with voltage-control • ANSI & IEC Standards
• Capacitor control method
source modeling • Load flow with graphical per phase display
• Flexible constraints
• Isolated 1-phase source & system modeling • Voltage drop & power losses
• Series fault or open phase condition modeling • Voltage & current unbalance factors Volt / Var Optimization & Control*
• Phase & sequence voltage, current, & power • Automatic device duty evaluation & alerts • Solve multiple objtectives simultaneously
• Voltage & current unbalance factors • Conservative voltage reduction
• Transmission line coupling Reliability Assessment • Optimize voltage profile
• Automatic device evaluation • System reliability • Minimize losses
• Report voltage & power in multi-units • Customer oriented indices • Determine voltage regulator & switched
• Optimized for multi-core CPU • Energy (cost) indices capacitor setpoints
• Sensitivity analysis • Optimal voltage regulation placement
• Single & double contingency • Looped & radial systems
• Looped & radial systems
9
ETAP GRID - Transmission
ETAP GRID™ Transmission provides an intelligent Network Topology Builder integrated with
ETAP’s Base and Network Analysis modules such as Transmission Line Model, SVC Model, HVDC
Link, Load Flow,Fault Analysis, Capacitor Placement, Dynamic Stability, Reliability Assessment,
Distance Protection, Substation Automation, Energy Management, and eSCADA system.
Transmission Systems
Line Constants Line Ampacity Sag & Tension
• Conductor & ground wire libraries • Conductor ampacity vs. temperature • Sag / tension vs. temperature
• Built-in configurations: horizontal, vertical, etc. • IEEE 738 Standard • Multiple spans between dead-end structures
• General configuration: X, Y, & Z coordinates • Determine maximum operating temperature • Level spans of unequal length
• Multi-line mutual coupling for various loading conditions • Solve spans of unequal length on different
• Phase & sequence impedance matrix • Derated ampacity based on temperature limit horizontal planes
• Transposed & un-transposed lines • Consider weather, solar heat, & • Include effects of wind, temperature, & k factor
• Short & long line models geographical location
• Multiple layer soil model HVDC Transmission Link
• Calculated or user-defined impedances
Optimal Power Flow • Detailed rectifier & converter modeling
• Solve multiple objectives simultaneously • Composite AC / DC & DC / AC systems
Contingency Analysis • Interior point method with barrier functions • Built-in control schemes
• N-1 & N-2 contingency assessment & ranking • Minimize power losses • Inclusive transformer model
• Fast screening method to scan outage list • Active power optimization • Automatic harmonic spectrum calculation
• Multiple graphical outage lists • Reactive power optimization • Easy-to-use integrated model
• Automatic performance indices calculation • Optimal dispatch • VSC-HVDC model*
• Summary report analyzer
ETAP Traction Power software includes the most accurate, highly developed, and flexible software tools
for analyzing and managing LV and MV rail power systems. eTraX provides a state-of-the-art design and
management solution for the electrical network life-cycle of the rail traction power system.
10
ETAP Real-Time
ETAP Real-Time™ technology allows you to predict, control, visualize, optimize, summarize and
automate your power system. Distributed and web-based technologies provide the tools to make
informative decisions based on planned or unplanned events from any location.
11
ETAP Real-Time
4000 240
Ge 2250
Cost ($)
2000 120
750
1000 60
MW
0 5.625 11.250 16.875 22.500
0 12.50 25.00 37.50 50.00
Output MW MW
Ge Ge
n2
le
as
n3
t
M
W
Ge
lo
n4
ss
M
W
MW
M
W
W
M
Ge
G
ne
en
1
rat
G
2000 200
en
Incr. HR (KBtu/MWh)
in
Input (1000 Btu/hr)
gC
G
$
en
1500 150
3
os
G
t
en
1000 100
4
500 50
ne
en
Output MW
1
rat
G
en
io
2
nD
G
en
isp
3
G
en
atc
4
12
ETAP Real-Time
13
Distribution Management System
ETAP ADMS™ is an integrated electrical system design and real-time power distribution
management system. ETAP ADMS incorporates SCADA, Distribution Management Applications &
Outage Management System (OMS) functionality in a single solution.
14
Microgrid Controller
ETAP is used by microgrid developers and engineers for detailed analyses and sizing of
distributed energy resources and associated equipment. Microgrid Master Controller brings the
design to life by connecting the system model with real-time data.
15
etap.com
Quality Assurance Commitment
ETAP is Verified and Validated (V&V) against field results, real system measurements, established programs, and hand calculations to ensure its
technical accuracy. Each release of ETAP undergoes a complete V&V process using thousands of test cases for each and every calculation module.
ETAP Quality Assurance program is specifically dedicated to meeting the requirements of:
Registered to ISO 9001:2008
ISO 9001:2008 10 CFR 50 Appendix B 10 CFR Part 21 10 CFR Part 50.55 ANSI/ASME N45.2
ASME NQA-1 CAN / CSA-Q396.1.2 ANSI / IEEE 730.1 ANSI N45.2.2
Certification No. 10002889 QM08
© 2015 ETAP / Operation Technology, Inc. All rights reserved. Certain names and/or logos used in this document may constitute trademarks, service marks, or trade names of Operation Technology, Inc.
Other brand and product names are trademarks of their respective holders. B16-PO-APR2015