Professional Documents
Culture Documents
System overview
166 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018) (PV array 1)
Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground mount, Peak power: 49.80 kWp
166 x TS4-R-M
166 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018) (PV array 2)
Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground mount, Peak power: 49.80 kWp
166 x TS4-R-M
166 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018) (PV array 3)
Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground mount, Peak power: 49.80 kWp
166 x TS4-R-M
1 x STP 50-40
PV design data
Signature
*Important: The yield values displayed are estimates. They are determined mathematically. SMA Solar Technology AG accepts no
responsibility for the real yield value which can deviate from the yield values displayed here. Reasons for deviations are various external
conditions, such as soiling of the PV modules or fluctuations in the efficiency of the PV modules.
PV design data
Input A: PV array 1
44 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input B: PV array 1
44 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input C: PV array 1
44 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input D: PV array 1
22 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input E: PV array 1
12 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
PV array and inverter type are only conditionally compatible, since the inverter is oversized in this combination (> 85 %).
PV design data
Input A: PV array 2
44 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input B: PV array 2
44 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input C: PV array 2
44 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input D: PV array 2
22 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input E: PV array 2
12 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
PV array and inverter type are only conditionally compatible, since the inverter is oversized in this combination (> 85 %).
PV design data
Input A: PV array 3
44 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input B: PV array 3
44 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input C: PV array 3
44 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input D: PV array 3
22 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
Input E: PV array 3
12 x Trina Solar Energy TSM-300DD05A.05 (II) (THE HONEY plus) (08/2018), Azimuth angle: 0 °, Tilt angle: 33 °, Mounting type: Ground
mount
PV array and inverter type are only conditionally compatible, since the inverter is oversized in this combination (> 85 %).
Overview
DC LV Total
Graphic
Cable material Single length Cross section Voltage drop Rel. power loss
Subproject 1
Lines LV1
Cable material Single length Cross section Line resistance Rel. power loss
Subproject 1
The displayed results are approximate values to give a general indication to users of possible operating results. The results are determined
mathematically. The actual operating results will be dictated significantly by the actual climatic conditions, the actual efficiency, the system
components' operating conditions and the individual consumption behavior and can deviate from the calculated results. SMA Solar
Technology AG therefore assumes no liability in the event of deviations between the calculated and actual operating results.
498 x TS4-R-M
Monitors the power, voltage and
current of the PV modules and
transmits the data to Sunny Portal
Ensure that all PV modules are within 15 m of the nearest gateway. If this is not possible, add an additional gateway. For
further information see "Gateway Placement Guide".
No separate Cloud Connect Advanced is required for some inverters since this function is already integrated in the device.
Check the specification of the selected inverters.
Subproject 1
Diagram
Table
1 8808 (4.5 %) 89 %
2 10821 (5.6 %) 90 %
3 15871 (8.2 %) 90 %
4 19381 (10.0 %) 89 %
5 21291 (10.9 %) 88 %
6 22758 (11.7 %) 87 %
7 25395 (13.1 %) 86 %
8 23644 (12.2 %) 87 %
9 17300 (8.9 %) 88 %
10 14716 (7.6 %) 88 %
11 6649 (3.4 %) 87 %
12 7821 (4.0 %) 89 %