You are on page 1of 8

Relion ® 615 series

Voltage protection and control


REU615
Compact and versatile solution for utility
and industrial power distribution systems
Compact voltage protection and
automatic voltage regulation

REU615 is a voltage protection and control relay for Standardized communication and redundancy
voltage and frequency-based protection in utility and REU615 fully supports the IEC 61850 standard for
industrial power distribution systems, including networks communication and interoperability of substation automation
with distributed power generation. REU615 is also ideal devices, including fast GOOSE messaging and IEC 61850-
for voltage regulation. 9-2 LE, and can now also benefit from the extended
interoperability provided by Edition 2. The voltage relay
Application further supports both the parallel redundancy protocol
REU615 is available in two standard configurations, both (PRP) and the high-availability seamless redundancy (HSR)
of which can be tailored to meet application-specific protocol, together with the DNP3, IEC 60870-5-103 and
requirements using the IEC 61850-compliant Protection and Modbus® protocols. With the protocol adapter SPA-ZC 302,
Control IED Manager PCM600. One has been exclusively Profibus DVP1 can also be used. REU615 is able to use two
designed for busbar under- and overvoltage supervision, communication protocols simultaneously.
load-shedding (disconnection) and restoration (reconnection)
applications. It can also be used for over- and underfrequency For redundant Ethernet communication, REU615 offers either
protection of power generators and other AC equipment such two optical or two galvanic Ethernet network interfaces. A
as capacitor banks. In generator and motor applications, third port with a galvanic Ethernet network interface provides
REU615 provides supplementary protection by detecting any connectivity of any other Ethernet device to an IEC 61850
deviation from the permitted frequency and voltage values. An station bus inside a switchgear bay. The redundant Ethernet
integrated synchro-check function ensures a safe connection solution can be built on the Ethernet-based IEC 61850,
of the equipment to the network. Modbus ® and DNP3 protocols.

The other of the two standard configurations has been The implementation of the IEC 61850 standard in REU615
exclusively designed for automatic and manual voltage covers both vertical and horizontal communication, including
regulation of power transformers with a motor-driven on- GOOSE messaging with both binary and analog signals as
load tap-changer. In small substations with a single power well as parameter setting according to IEC 61850-8-1. Also
transformer and in substations with two or more power IEC 61850-9-2 LE process bus with sending sampled values
transformers operating in parallel, REU615 can be used for of not only analog voltages but now also currents, in addition
load-side voltage regulation. The standard configuration also to receiving sampled values of voltages, is supported. The
includes protection functionality. sampled values can now be used for synchro-check as
well to ensure safe interconnection of two networks. For
To minimize the effects of an arc fault, REU615 can be process bus applications, which require high-accuracy time
equipped with high-speed outputs decreasing the operate synchronization, IEEE 1588 V2 is used, with a time stamp
time by four to six milliseconds compared to conventional resolution of not more than four microseconds. IEEE 1588
binary outputs. V2 is supported in all variants with a redundant Ethernet
communication module. In addition, REU615 supports
Human-machine interface synchronization over Ethernet using SNTP or over a separate
As a member of the Relion® product family, REU615 shares bus using IRIG-B.
the same human-machine interface (HMI) look and feel as the
other Relion protection and control relays and IEDs. The same
look and feel includes the location of a push button with a
certain function and the menu structure.

REU615 is equipped with a large graphical display which


can show customizable single-line diagrams (SLD) with
position indication for the circuit breaker, disconnectors and
the earthing switch. Also measured values provided by the
chosen standard configuration can be displayed. The SLDs
are customized using PCM600 and can have multiple pages
for easy access to selected information. The SLDs can be
accessed not only locally but also via the web browser-based
HMI that has now been enriched with a number of usability
enhancing features.

2 Voltage protection and control | REU615


Uo

UL1UL2UL3

REU615 VOLTAGE PROTECTION AND CONTROL RELAY STANDARD


CONFIGURATION
A

PROTECTION LOCAL HMI ALSO AVAILABLE

- Disturbance and fault recorders


2× - Event log and recorded data
Master Trip
- High-Speed Output module (optional)
Configuration A
System

Lockout relay
HMI
Time
Authorization

- Local/Remote push button on LHMI


94/86 I ESC Clear
- Self-supervision
- Time synchronization: IEEE 1588 v2,
A
O R
L
U12 0. 0 kV
P 0.00 kW
Q 0.00 kVAr SNTP, IRIG-B
- User management
IL2 0 A

- Web HMI
3× 3× I ESC Clear

ARC AND
50L/50NL O R
L
OR

CONDITION MONITORING COMMUNICATION


AND SUPERVISION
Protocols:
3× 2× 2× 3× 2× IEC 61850-8-1/9-2LE
3U< U2> U1< 3U> OPTS TCS Modbus®
UL1UL2UL3 27 47O- 47U+ 59 OPTM TCM IEC 60870-5-103
DNP3
Interfaces:
3× 6×
Uo Uo> f>/f<, Ethernet: TX (RJ45), FX (LC)
df/dt Serial: Serial glass fiber (ST),
59G
81 RS-485, RS-232
U12 Redundant protocols:
HSR
PRP
RSTP


UFLS/R
CONTROL AND INDICATION 1) MEASUREMENT
81LSH
- U, Uo, f
Object Ctrl 2)
Ind 3)
- Symmetrical components
18×
MAP CB 1 - - Limit value supervision
MAP DC 2 3
Analog interface types 1)

ES 1 2
Current transformer -
1)
Check availability of binary inputs/outputs
from technical documentation Voltage transformer 5
2)
Control and indication function for 1)
Conventional transformer inputs
primary object
3)
Status indication function for
primary object

UL1UL2UL3 SYNC
25
U12

REMARKS
Optional 3× No. of Calculated OR Alternative
function instances value function to be
Io/Uo defined when
ordering

Function overview of REU615 standard configuration A

Main benefits 615 series


− − Withdrawable plug-in unit design for swift installation and REU615 is a member of ABB’s Relion product family and
testing part of its 615 protection and control series of relays,
− − Extensive range of protection and control functionality for characterized by compactness and withdrawable plug-in unit
busbar voltage supervision, load-shedding and restoration, design. In addition to REU615, the 615 series includes the
including over- and underfrequency protection for power following relays:
generators and other AC equipment
− − Ready-made standard configurations for fast and easy −− REF615 Feeder protection and control
setup with tailoring capabilities −− RED615 Line differential protection and control
− − Automatic voltage regulation of power transformers with a −− RET615 Transformer protection and control
motor-driven on-load tap-changer −− REM615 Motor protection and control
− − IEC 61850 Edition 2 and Edition 1 support, including HSR −− REV615 Capacitor bank protection and control
and PRP, GOOSE messaging and IEC 61850-9-2 LE for −− REG615 Generator and interconnection protection
less wiring and supervised communication
−− IEEE 1588 V2 for high-accuracy time synchronization Life cycle services
and maximum benefit of substation-level Ethernet ABB offers full support for all protection and control relays
communication throughout their entire lifecycle. Our extensive life cycle
− − Large graphical display for showing customizable SLDs, services include training, customer support, maintenance and
accessible either locally or through a web browser-based modernization.
HMI

REU615 | Voltage protection and control 3


REU615 VOLTAGE PROTECTION AND CONTROL RELAY
Automatic voltage regulator
STANDARD
CONFIGURATION
B

PROTECTION LOCAL HMI ALSO AVAILABLE

- Disturbance and fault recorders


2× - Event log and recorded data
Master Trip
- Local/Remote push button on LHMI
Configuration A
System

Lockout relay
HMI
Time
Authorization

- Self-supervision
94/86 I ESC Clear
- Time synchronization: IEEE 1588 v2,
SNTP, IRIG-B
A
O R
L
U12 0. 0 kV
P 0.00 kW
Q 0.00 kVAr - User management
- Web HMI
IL2 0 A

18× I ESC Clear

MAP AND
MAP O R
L
OR
6xRTD
2xmA

CONDITION MONITORING COMMUNICATION


3I AND SUPERVISION
Protocols:
IEC 61850-8-1/9-2LE
3Ith>T/G/C 3I>>> 3I> FUSEF MCS 3I OPTS Modbus®
49T/G/C 50P/51P 51P-1 60 MCS 3I OPTM IEC 60870-5-103
DNP3
Interfaces:

Ethernet: TX (RJ45), FX (LC)
3I>> TCS
Serial: Serial glass fiber (ST),
51P-2 TCM
RS-485, RS-232
Redundant protocols:
HSR
PRP
RSTP

CONTROL AND INDICATION 1)


MEASUREMENT
3× 3× U L1 U L2 U L3
3U< 3U>
27 59 Object Ctrl 2)
Ind 3)
- I, U, P, Q, E, pf
- Symmetrical components
CB 1 -
- Limit value supervision
DC 2 3 - RTD/mA measurement (optional)
ES 1 2
1)
Check availability of binary inputs/outputs Analog interface types 1)

from technical documentation Current transformer 4


2)
Control and indication function for
primary object Voltage transformer 3
3)
Status indication function for
primary object
1)
Conventional transformer inputs

I∑
TPOSM COLTC
84M 90V

3I

REMARKS
Optional 3× No. of Calculated OR Alternative
function instances Io/Uo value function to be
defined when
Sum of phase ordering
I∑
currents

Function overview of REU615 standard configuration B

4 Voltage protection and control | REU615


REU615 | Voltage protection and control 5
Standard configurations

Standard configurations
Standard
Description
configuration
Voltage and frequency based protection, synchro-check and load-shedding A
Automatic voltage regulator B

1, 2,... = number of included instances / I/Os


( ) = optional

Supported functions, codes and symbols


Functionality IEC 61850 IEC 60617 IEC-ANSI A B
Protection
Three-phase non-directional overcurrent protection, low stage PHLPTOC 3I> 51P-1 -  1
Three-phase non-directional overcurrent protection, high stage PHHPTOC 3I>> 51P-2 - 1
Three-phase non-directional overcurrent protection, instantaneous stage PHIPTOC 3I>>> 50P/51P -  1
Residual overvoltage protection ROVPTOV Uo> 59G 3 - 
Three-phase overvoltage protection PHPTOV 3U> 59 3 3
Three-phase undervoltage protection PHPTUV 3U< 27 3 3
Positive-sequence undervoltage protection PSPTUV U1< 47U+ 2 - 
Negative-sequence overvoltage protection NSPTOV U2> 47O- 2 - 
Frequency protection FRPFRQ f>/f<, df/dt 81 6 - 
Three-phase thermal overload protection, two time constants T2PTTR 3Ith>T/G/C 49T/G/C - 1
Master trip TRPPTRC Master Trip 94/86 2 2
Arc protection ARCSARC ARC 50L/50NL (3) 1)
-
Multi-purpose protection 1)
MAPGAPC MAP MAP 18 18
Load shedding and restoration LSHDPFRQ UFLS/R 81LSH 5 - 
Control
Circuit-breaker control CBXCBR I ↔ O CB I ↔ O CB 1 1
Disconnector control DCXSWI I ↔ O DCC I ↔ O DCC 2 2
Earthing switch control ESXSWI I ↔ O ESC I ↔ O ESC 1 1
Disconnector position indication DCSXSWI I ↔ O DC I ↔ O DC 3 3
Earthing switch indication ESSXSWI I ↔ O ES I ↔ O ES 2 2
Tap changer position indication TPOSSLTC TPOSM 84M - 1
Tap changer control with voltage regulator OLATCC COLTC 90V - 1
Synchronism and energizing check SECRSYN SYNC 25 1 -
Condition Monitoring
Trip circuit supervision TCSSCBR TCS TCM 2 2
Current circuit supervision CCRDIF MCS 3I MCS 3I - 1
Fuse failure supervision SEQRFUF FUSEF 60 - 1
Runtime counter for machines and devices MDSOPT OPTS OPTM 1 1

6 Voltage protection and control | REU615


1, 2,... = number of included instances / I/Os
( ) = optional

Supported functions, codes and symbols


Functionality IEC 61850 IEC 60617 IEC-ANSI A B
Measurement
Disturbance recorder RDRE DR DFR 1 1
Load profile record LDPMSTA LOADPROF LOADPROF 1 1
Fault record FLTRFRC FAULTREC FAULTREC 1 1
Three-phase current measurement CMMXU 3I 3I  - 1
Sequence current measurement CSMSQI I1, I2, I0 I1, I2, I0  - 1
Three-phase voltage measurement VMMXU 3U 3V 2 1
Residual voltage measurement RESVMMXU Uo Vn 1  -
Sequence voltage measurement VSMSQI U1, U2, U0 V1, V2, V0 1 1
Three-phase power and energy measurement PEMMXU P, E P, E  - 1
RTD/mA measurement XRGGIO130 X130 (RTD) X130 (RTD)  - (1)
Frequency measurement FMMXU f f 1  -
IEC 61850-9-2 LE sampled value sending 2) 3)
SMVSENDER SMVSENDER SMVSENDER (1) (1)
IEC 61850-9-2 LE sampled value receiving (voltage sharing) 2) 3)
SMVRCV SMVRCV SMVRCV (1) (1)

1)
Light only
2)
Available only with IEC 61850-9-2
3)
Available only with COM0031-0034

REU615 | Voltage protection and control 7


Contact us

For more information, please refer to

© Copyright 2016 ABB. All rights reserved.


REU615 Product Guide, or contact us:

ABB Oy, Medium Voltage Products


Distribution Automation
P.O. Box 699
FI-65101 VAASA, Finland
Phone: +358 10 22 11
Fax: +358 10 22 41094

ABB India Limited, Distribution Automation

1MRS757062 H, 5.0 FP1


Maneja Works
Vadodara – 390013, India
Phone: +91 265 272 4402
Fax: +91 265 263 8922

www.abb.com/mediumvoltage
www.abb.com/substationautomation

You might also like