Professional Documents
Culture Documents
ME-3rd Year - RAC CT-3
ME-3rd Year - RAC CT-3
Section-C
1. A refrigeration system using R-12 as refrigerant consist three evaporators of capacity 20TR at -10 °C, 30TR at 5°C and 10 TR at
10°C.the vapours leaving three evaporators are dry and saturated. The system is provided with individual compressor and multiple
expansion valve. The condenser temperature is 40°C and the liquid refrigerant leaving the condenser is subcooled to 30°C. Assuming
isentropic compression in each compressor find mass of refrigerant through each evaporator, power required, cop of the system. TQ.2
2. Draw and explain the cycle and ph chart for multiple evaporators at different temp with compound compression, individual expansion
valve and flash intercooler. TQ.3
Set 2
Section-C
1. In an aqua ammonia absorption system of 10TR capacity, the vapours leaving the generator are 100% pure NH 3 saturated at 40°C the
evaporator absorber condenser and generator tem are -20°C,30°C, 40°C, and 70°C.at absorber exit x=0.38 and enthalpy h=22kj/kg at
generator exit x=0.1and h=695kj/kg. determine
Mass flow rate in the evaporator, determine the, heat rejection in absorber and condenser. Heat added to generator, cop, over all mass
conservation. TQ 4
2. Work done by a single stage, single acting reciprocating compressor without clearance volume. TQ 5
Set -3
RAJARSHI RANANJAY SINH INSTITUE OF MANAGEMENT & TECHNOLOGY
Mechanical Engineering: 3rd Year (6th Sem.)
REFRIGERATION & AIR CONDITIONING
Class Test-03
Max. Time: (01:00 Hr.) M.M:30
Section-A
Section-C