You are on page 1of 8

Interpolation

A 1.4 D 0.426
B 1.45 E 0.443
C 1.421 X 0.43314
DESIGN OF SLAB

Fy= 415 Fck= 20

1. Unit Wt. of materials

Marble 27 Kn/m3
Screed/plaster 20.4 Kn/m3
RCC 25 Kn/m3
Brick masonry 19.2 Kn/m3

2. Assume the thickness of slab 150 mm

3. Floor load calculation Live load 3

Materials Thickness(mm) Load/area Unit


MARBLE 20 0.54 kN/m2
SCREED 25 0.51 kN/m2
CEILING PLASTER 12.5 0.255 kN/m2
Total 1.305 kN/m2
STR Slab 150 3.75 kN/m2
Total dea load from floor slab 5.055 kN/m2
dead load from partition wall 1.65
Provision for partition wall 1 kN/m2
Live loads on floors 5 kN/m2
Total Dead+Live load 12.705
Factored Load 19.0575 kN/m2

4. Design Parameters

Long Span,Ly 5.2 m


Short Span,Lx 4.9 m

Aspect Ration(ly/Lx) 1.061

Boundary Condition Two adjacent edge discontinous


eff. Depth along short span,dx 131
Eff. Depth along long span,dy 123

From table 22 of appendix C of IS 456:2000, the BM coefficients are

-αx 0.053
+αx 0.04
-αy 0.047
+αy 0.035

Using the formula,Mux=αx*Wu*Lx^2 and Muy=αy*Wu*Lx^2

-Mux 24.25124 kN-m


+Mux 18.30282 kN-m
-Muy 21.50582 kN-m
+Muy 16.01497 kN-m

Similarly,the values of Mu/bd^2 and percentage of tension reinforcement required are

-Mux/(bd^2) 1.41316 Pt(-x) 0.43 %


+Mux/(bd^2) 1.066536 Pt(+x) 0.316 %
-Muy/(bd^2) 1.421496 Pt(-y) 0.433 %
+Muy/(bd^2) 1.058561 Pt(+y) 0.313 %

3. Check for Deflection

From above,percentage of reinforcement required at mid span of short span is:


Pt(+x) 0.316

Assuming pt provided=pt required= 0.316

service stress,Fs=0.58*Fy*(pt required/provided)= 240.7


From graph of fig 4 for IS 456:2000
Modification factor for tension reinforcement= 1.4
Hence, permissible(L/d)=MF*(L/d)basic= 32.2 37.95

Actual(L/d)= 37.40458

hence(L/d) actual is more than permissible Not SAFE

Provide( Pt)= 0.4

Now, Fs= 190.153


Modification Factor= 1.65
Hence permissible L/d= 37.95

Hence Actual L/d is less than permissible SAFE

Final Values for this slab are therefore:

pt(-x) 0.43
pt(+x) 0.4
Pt(-y) 0.433
Pt(+y) 0.313

Use 10mm dia bar 78.5 mm2

reinforcement at (-x) 563.3 mm2


use 8mm bar @ 139.3574 mm
Reinforcement at(+x) 524 mm2
use 8mm bar @ 149.8092 mm
Reinforcement at(-y) 532.59
use 8mm bar @ 147.3929 mm
reinforcement at(+y) 384.99
use 8mm bar @ 203.9014

Hence provide 10mm dia bar @ 125mm C/C


1.047198
DESIGN OF SLAB

Fy= 415 Fck= 20

1. Unit Wt. of materials

Marble 27 Kn/m3
Screed/plaster 20.4 Kn/m3
RCC 25 Kn/m3

2. Assume the thickness of slab 125 mm

3. Floor load calculation Live load 3

Materials Thickness(mm) Load/area Unit


MARBLE 20 0.54 kN/m2
SCREED 25 0.51 kN/m2
CEILING PLASTER 12.5 0.255 kN/m2
Total 1.305 kN/m2
STR Slab 125 3.125 kN/m2
Total dea load from floor slab 4.43 kN/m2
Provision for partition wall 1 kN/m2
Live loads on floors 3 kN/m2
Total Dead+Live load 8.43
Factored Load 12.645 kN/m2

4. Design Parameters

Long Span,Ly 4.813 m


Short Span,Lx 4.5 m

Aspect Ration(ly/Lx) 1.070

Boundary Condition Two adjacent edge discontinous


eff. Depth along short span,dx 106
Eff. Depth along long span,dy 98

From table 22 of appendix C of IS 456:2000, the BM coefficients are

-αx 0.053
+αx 0.04
-αy 0.047
+αy 0.035

Using the formula,Mux=αx*Wu*Lx^2 and Muy=αy*Wu*Lx^2

-Mux 13.57125 kN-m


+Mux 10.24245 kN-m
-Muy 12.03488 kN-m
+Muy 8.962144 kN-m

Similarly,the values of Mu/bd^2 and percentage of tension reinforcement required are

-Mux/(bd^2) 1.207836 Pt(-x) 0.361 %


+Mux/(bd^2) 0.911574 Pt(+x) 0.267 %
-Muy/(bd^2) 1.253111 Pt(-y) 0.376 %
+Muy/(bd^2) 0.933168 Pt(+y) 0.274 %

3. Check for Deflection

From above,percentage of reinforcement required at mid span of short span is:


Pt(+x) 0.267

Assuming pt provided=pt required= 0.267

service stress,Fs=0.58*Fy*(pt required/provided)= 240.7


From graph of fig 4 for IS 456:2000
Modification factor for tension reinforcement= 1.55
Hence, permissible(L/d)=MF*(L/d)basic= 35.65

Actual(L/d)= 42.45283

hence(L/d) actual is more than permissible NOT SAFE

So,modification factor required = 1.845775


now increase percentage of steel = 0.33
then, service stress, FS=0.58*415*(required pt/provided pt)= 194.74818

modification factor= 1.8


41.4

Final Values for this slab are therefore:

pt(-x) 0.361
pt(+x) 0.267
Pt(-y) 0.376
Pt(+y) 0.274
Use 8mm dia bar 50.26 mm2

reinforcement at (-x) 382.66 mm2


use 8mm bar @ 131.3438 mm
Reinforcement at(+x) 283.02 mm2
use 8mm bar @ 177.5846 mm
Reinforcement at(-y) 368.48
use 8mm bar @ 136.3982 mm
reinforcement at(+y) 268.52

Hence provide 8mm dia bar @ 150mm C/C in bottom and 8mm dia bar @125mm C/C in top