Alimentatore PS440/xxx per terminali di pesatura

Istruzioni di sicurezza
Power supplier PS440/xxx for weighing terminals)
Safety instructions
Alimentation PS440/xxx pour indicateurs de pesage
Consignes de sécurité
Versorgungsgerät PS440/xxx für Wägeterminals
Sicherheitsanweisungen

‫ زاطحمل نزولا‬SP440/XXX ‫يذغم نزيتما نزابرهملا‬

‫تامتامل نزالسيا‬

Italiano English Français Deutsch ‫العربية‬

81320144en 05/11/2018
_____________________________PS440/xxx__
Table of Contents
1. Description ........................................................................................................................... 2
2. Mechanical specifications ................................................................................................... 2
3. Electrical specifications ...................................................................................................... 3
4. Marking ................................................................................................................................. 4
4.1 AREAS AND CATEGORIES 4
5. Safety instructions for installation in hazardous areas.................................................... 5
5.1 WIRING DIAGRAM 6
5.1.1 Exe connections ........................................................................................... 8
5.1.2 Exi connections ............................................................................................ 8
5.1.3 Conductor connections ................................................................................ 8
5.2 CASING 9
5.3 CABLE GLANDS 9
5.4 APPLICATION EXAMPLE 9
6. Instructions for disposing of waste electrical or electronic equipment...................... 10
7. Declaration of conformity ................................................................................................ 11

1
Foreword
_____________________ Note _____________________
Document relating to CESI 05 ATEX 023 certificate.
No changes are permitted without the approval of the "Authorised Person"
_______________________________________________

1. Description

Power supplier PS440/xxx accepts various voltages on the input, as indicated in


the following table:
 PS440/230Vac: 230 Vac input voltage
 PS440/115Vac: 115 Vac input voltage
 PS440/24Vac: 24 Vac input voltage

Power supplier PS440/xxx provides the necessary voltages and interfacing


signals for operating weighing terminal D440IS, by means of intrinsic safety
circuits.
The power supplier is suitable for operation in areas where there is a risk of
explosion. It is made in compliance with directive ATEX 2014/34/UE and
according to standards EN60079-0, EN60079-7, EN60079-11, EN60079-18,
EN60079-26, EN60079-31, with protection degree :

 GAS : Ex e mb [ia Ga] IIC T5, T4 Gb


 DUST : Ex tb mb [ia Da] IIIC T100°C, T135°C Db
 Ambient operating temperature
 Tamb (- 20°C ÷ + 40°C) T5/T100°C
 Tamb (- 20°C ÷ + 55°C)  T4/T135°C

Power supplier PS440/xxx is housed in a polyester casing with IP66 protection


degree and gas cable glands Ex-e/Ex-t through which the entering cables are
routed.

2. Mechanical specifications
Cable gland M16x1.5
Cable diameter: 6.5 –12 mm

2
3. Electrical specifications
Mains power supply Pn=20VA Um=250V
L (line), N(neutral), T(ground) Fn=50/60Hz
PS440/230Vac Un =230Vac
PS440/115Vac Un =115Vac
PS440/24Vac Un =24Vac

Outputs (clean contacts) UMAX=125Vac/dc


Out1 terminals 1-2 I MAX=200mA
Out2 terminals 3-4
Out3 terminals 5-6
Out4 terminals 1-2

Display power supply Uo =12.24V Co  1.28uF


Terminals 19(+) 16(-) Io = 860mA Lo  25nH
CPU Power supply Po = 2.6W
Terminals 18(+) 16(-)

Input power supply Uo =17.6V Co  333nF


Terminals 17(+) 16(-) Io = 393mA Lo  60H
Po = 1.7W

Load cell power supply Uo =6.6V Co  22F


Terminals 15(+) 14(-) Io = 231mA Lo  500H
Po = 381mW

Output commands Uo =6.6V Co  40F


Out 1 Terminals 13(+) 9(-) Io = 42mA Lo  10mH
Out 2 Terminals 12(+) 9(-) Po = 63mW
Out 3 Terminals 11(+) 9(-)
Out 4 Terminals 10(+) 9(-)

3
4. Marking
0722 CESI YY ATEX nnn
II 2(1) G Ex e mb [ia Ga] IIC T5, T4 Gb
II 2(1) D Ex tb mb [ia Da] IIIC T100°C, T135°C Db
Tamb (- 20°C ÷ + 40°C)→ T5/T100°C
Tamb (- 20°C ÷ + 55°C)→ T4/T135°C

0722 number of the Notified Body for ATEX surveillance (CESI)


CESI YY ATEX nnn Number of certificate and body that issued it
II group II (surface)
2 (1) category of equipment
G explosive atmosphere where gas, mist or vapour are present
Ex e mb [ia Ga] protection method
IIC group of gas
T5, T4 gas temperature category
Gb EPL GAS
D explosive atmosphere with dust
Ex tb mb [ia Da] protection method
IIIC conductive dust
T=100°C, 135°C maximum surface temperature of casing
Db EPL DUST
Operating ambient - 20 °C ÷ + 40 °C (T5/T100°C)
temperature - 20 °C ÷ +55 °C (T4/T135°C)
IP66 protection degree of casing

4.1 Areas and categories


Hazardous area Categories according to Equipment protection level
Directive 2014/34/UE
Gas, vapours or mist Area 0 1G Ga
Gas, vapours or mist Area 1 1G or 2G Ga or Gb
Gas, vapours or mist Area 2 1G, 2G or 3G Ga, Gb or Gc
Dust Area 20 1D Da
Dust Area 21 1D or 2D Da or Db
Dust Area 22 1D, 2D or 3D Da, Db or Dc

4
5. Safety instructions for installation in hazardous areas
Power supplier PS440/xxx (note 1) must be installed and serviced in compliance
with the installation and maintenance instructions for sites classified against the
risk of explosion, owing to the presence of gas and dust (example: EN 60079-
14, EN 60079-17 or other national norms/standards).
Warning: carefully read the technical specifications enclosed with both power
supplier PS440/xxx (note 1) and terminal D440IS.

Plate warning:
“DO NOT OPEN WHEN UNDER POWER”

Note 1:
 Power supplier PS440/xxx is supplied for different powering voltage ratings.
The xxx suffix indicates the value and type of power input.

5
5.1 Wiring diagram

Figure 1 Block diagram of the connections


Key
rete mains
barriera cella cell barrier
barriera display display barrier
barriera cpu CPU barrier
barriera input input barrier
barriera output output barrier
x 4 sezioni di output su relay for 4 output sections on relay
Modulo alimentatore incapsulato Encapsulated power supplier module
barriera segnale signal barrier
barriera sense sense barrier
terra ground
fibra ottica optic fiber
1 canale 1 channel
uscita analog. analog output
input Exi Exi inputs
celle Exi Exi cells
6power+4out+comune 6power+4out+common contact
ESPANSIONE USCITA ANALOGICA ANALOG OUTPUT EXPANSION
ESPANSIONE FIBRA OTTICA OPTIC FIBER EXPANSION
fino a 4x350ohm o 8x700 up to 4x350 Ohms or 8x700
Vexi-cella Vexi-cell

6
The D440IS terminal part is not described in these Safety Notes. Consult the
relative documentation for more details.

7
5.1.1 Exe connections

Terminal N° Signal Description


L Line Power supply: line
T Ground Safety ground connection
N Neutral Power supply: neutral
1
Out1 Clean contact
2
3
Out2 Output 2 clean contact
4
5
Out3 Output 3 clean contact
6
7
Out4 Output 4 clean contact
8

5.1.2 Exi connections


Terminal N° Signal Description
9 GND_RELAY Common relay command
10 Out4 Output 4 command
11 Out3 Output 3 command
12 Out2 Output 2 command
13 Out1 Output 1 command
14 EXC-_EX exi - load cell power supply
15 EXC+_EX exi + load cell power supply
16 DGND Digital ground
17 +14INPUT_EX exi power supply of the inputs and of the
board 4-20 mA analog current output
18 +6V_EX exi power supply for CPU
19 +6VDISP_EX exi power supply for display

5.1.3 Conductor connections

 Prepare conductors with insulated pins for connection to the terminals.


 Keep the exi conductors separate from the non-exi ones.

8
5.2 Casing
The user must clean the casing regularly, to prevent a layer of dust from
forming.

5.3 Cable glands


Insert the conductors into the cable glands and then tighten these latter.
Unused cable glands must be closed with the supplied plugs.

5.4 Application example

D440
IS
PC
Input CELL 1…..4
Optic fiber (*)
4-20mA (*)

230 Vac

PS440/230V
ac
L+N+T

Output

SAFE AREA HAZARDOUS AREA

Figure 2 Application example


Note (*): optic fiber and analog output can be installed as alternatives

9
6. Instructions for disposing of waste electrical or
electronic equipment

This symbol on the weighing instrument you have purchased


means that:
 this electric or electronic appliance cannot be disposed of as
solid municipal waste;
 it must be collected separately;
 it can be returned to the dealer when a new one is purchased;
 improper use or disposal of this appliance may pollute the environment or
damage the health of human beings;
 failure to comply with the aforementioned instructions is punished by law.

In particular:
 the external casing and the mechanical components are made of plastic
and/or metal materials;
 the casing contains printed circuits with electronic components;
 the electrical connections are made with insulated copper conductors.

_________________WARNING________________

Dispose of this appliance by means of separate collection or take it back to the


dealer or to a differentiated collection centre.
___________________________________________

10
7. Declaration of conformity EU
We SOCIETÀ COOPERATIVA BILANCIAI A.R.L.
Via S. Ferrari, 16
41011 Campogalliano - MODENA
Hereby declare under our responsibility, that products:

 PS440/230Vac: power supplier with 230 Vac input voltage, lot/SN: .....
 PS440/115Vac: power supplier with 115 Vac input voltage, lot/SN: ......
 PS440/24Vac: power supplier with 24 Vac input voltage, lot/SN: ..........
lot/SN: See SN on the front page

described in this declaration conform to the following directives:

- Directive 2014/34/UE (ATEX)


- Directive 2014/30/UE ( EMC)
- Directive 2014/35/UE (LVD)
- Directive 2014/31/UE (NAWI)

Conformity is demonstrated by compliance with the following standards:


EN 61000-6-3 :2007 EN 60079-0 : 2012 EN 60079-7 : 2015 EN 45501 :2015
EN 61000-6-4 :2007 EN 60079-11 : 2012 EN 60079-18 : 2015
EN 60079-26 : 2007 EN 60079-31 : 2014

Mark / Protection modes:


II 2(1) G Ex e mb [ia Ga] IIC T5, T4 Gb
II 2(1) D Ex tb mb [ia Da] IIIC T100°C, T135°C Db
Tamb (- 20°C ÷ + 40°C) T5/100°C
Tamb (- 20°C ÷ + 55°C) T4/135°C

CE type certificate N°: CESI 05 ATEX 023

ATEX/Q notified body for surveillance: CESI 0722


Place and Date of issue: Signed for and on behalf of:
Campogalliano, 05/11/2018

11
SOC. COOP. BILANCIAI CAMPOGALLIANO A.R.L.
41011 Campogalliano (MO) Via Ferrari, 16
tel. +39 (0) 59 893611 – fax +39 (0) 59 527079
home page: http://www.coopbilanciai.it
E-mail: cb@coopbilanciai.it

servizio post-vendita after sales service service apres-vente


Kundendienstservice servicio post-venta serviço pós-venda
tel. +39 (0) 59 893612 – fax +39 (0) 59 527294
______________________________________________________________________

12

You might also like