You are on page 1of 12

Alcatel-Lucent 9400 AWY

Short-haul low/medium capacity digital microwave radio links

Test Result Sheet & Site Acceptance Test Protocol


Link Configuration
Date (dd/mm/yyyy)

Site A
Name
Location

Site B
Name
Location
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of
Alcatel-Lucent.

All other trademarks are the property of their respective owners.

The information presented is subject to change without notice. Alcatel-Lucent assumes


no responsibility for inaccuracies contained herein.

Copyright 2008 Alcatel-Lucent

All rights reserved.


Passing on and copying of this document,
use and communication of its contents is not permitted
without written authorization from Alcatel-Lucent
1. DOCUMENT SCOPE AND STRUCTURE, REFERENCE DOCUMENTATION AND
THRESHOLD TABLES

This document is used in the equipment commissioning and acceptance phases.

This document is created as described in the Chapter Line-Up and Commissioning of the: 9400AWY User
Mannual/Guide associated to the employed SWP 9400AWY version

This document consists of two parts:


• Test Report Sheets
- These sheets are used to report the results of tests described in the User Manual's chapter above
• Site Acceptance Test Protocol

Please refer to the User Manual cited above to retrieve updated information you may need, in particular:
• Chapter TECHNICAL SPECIFICATIONS, for all technical characteristics like:
• Transmitted Power at antenna port
• System Characteristics and BER intrusive thresholds
• Chapter ODU INSTALLATION COMPONENTS, for detailed information regarding ODU Part Numbers and
related frequency shifters and frequency bands
2. SYSTEM INSTALLATION AND CABLING VISUAL INSPECTION

SITE A SITE B
INDOOR INSTALLATION VISUAL INSPECTION CHECK
OK NOK OK NOK

Check Rack allocation according to the station layout

Check Sub-Rack allocation according to the station layout

Check Rack and Sub-racks ground connections

Check TRU or Other Power Supply distributor position and connection

Check Power Supply protection circuit breakers values

Check E1 - 1 to 16 cabling and labelling on station DDF

Check E3 cabling and labelling on station DDF

Check interconnections between IDUs and E1 & Service protection panels


(if foreseen by plant doc.)

Check Service Channel cabling and labelling on DDF (if foreseen by plant doc.)

Check Housekeeping alarm cabling and labelling on DDF (if foreseen by plant doc.)

Check NMS supervision Channel interconnection (if foreseen by plant doc.)

Check EOW Audio Channel interconnection (if foreseen by plant doc.)

SITE A SITE B
OUTDOOR INSTALLATION VISUAL INSPECTION CHECK
OK NOK OK NOK

Check Antenna(s) Position according to the plant documentation

Check Antenna(s) Polarization according to the Plant documentation

Check Antenna(s) EMF warning labelling presence

Check ODU(s) Cable connection waterproofing with rubber tape

Check ODU(s) Grounding

Check IDU/ODU Cable(s) Grounding

Check ODUs RF Coupler Grounding (1+1 configuration only)

Check Antenna(s) Grounding (Non integrated Antenna only)


Check ODU(s) and pole mounting position according to the plant documentation
(Non integrated Antenna only)
Check Flex twist connection (Non integrated Antenna only)
3. EQUIPMENT IDENTIFICATION

SITE A SITE B

Product code Serial number Product code Serial number

Main Indoor Unit

Spare Indoor Unit

Flash Card
Traffic Plugin:
17-32E1 I/O SCSI 68-pin
Audio + ESC channel plugin

Main Outdoor Unit

Spare Outdoor Unit

Coupler

Antenna 1

Antenna 2

SITE A SITE B

Antenna 1 Antenna 2 Antenna 1 Antenna 2

Polarization

Diameter
4. LINK CONFIGURATION SUMMARY

Frequency band (GHz)


Configuration
Tributary
Modulation
Maximum hardware capacity
Impedance

SITE A SITE B
Active Software Release
Standby Software Release
SW license string
Link identifier configuration
Link identifier enable
Value expected/Value sent
Frequency and Power parameters
Channel 1 Channel 0 Channel 1 Channel 0
Tx Frequency (MHz)
Rx Frequency (MHz)
Tx power (dBm)
ATPC Range - PTX Min Value (dBm)
ATPC Range - PTX Max Value (dBm)
ATPC Rx Threeshold - Low Power (dBm)
Rx level reading (dBm)
Rx level calculated (dBm)
Automatic Restoration Criteria (1+1 only)
MUX/DEMUX (optional)
HST TX (optional)
RADIO
Overhead configuration (optional)
User Service Channel Type
EOW Phone Number
5. NETWORK ELEMENT CONFIGURATION

SITE A
IP Address:
OSPF AREA Configuration
AREA ID (0 - 3) IP Address
Stub Flag IP Mask
AREA ID (0 - 3) IP Address
Stub Flag IP Mask
AREA ID (0 - 3) IP Address
Stub Flag IP Mask
NMS IP Point-to-Point Interface Configuration
Interface Status Remote IP Address OSPF
NMS V11 Enabled Disabled
NMS G703 Enabled Disabled
NMS Radio Site Enabled Disabled
Ethernet (OS) configuration
Enabled Disabled IP Address
IP Routing IP Mask
IP static routing configuration
Host Network IP Address
IP Address
Default Gateway IP Address
Point to Point Interface Index RF V11 G703
Host Network IP Address
IP Address
Default Gateway IP Address
Point to Point Interface Index RF V11 G703
Host Network IP Address
IP Address
Default Gateway IP Address
Point to Point Interface Index RF V11 G703
Network Time Protocol
Enabled Disabled Main Server
Spare Server
SITE B
IP Address:
OSPF AREA Configuration
AREA ID (0 - 3) IP Address
Stub Flag IP Mask
AREA ID (0 - 3) IP Address
Stub Flag IP Mask
AREA ID (0 - 3) IP Address
Stub Flag IP Mask
NMS IP Point-to-Point Interface Configuration
Interface Status Remote IP Address OSPF
NMS V11 Enabled Disabled
NMS G703 Enabled Disabled
NMS Radio Site Enabled Disabled
Ethernet (OS) configuration
Enabled Disabled IP Address
IP Routing IP Mask
IP static routing configuration
Host Network IP Address
IP Address
Default Gateway IP Address
Point to Point Interface Index RF V11 G703
Host Network IP Address
IP Address
Default Gateway IP Address
Point to Point Interface Index RF V11 G703
Host Network IP Address
IP Address
Default Gateway IP Address
Point to Point Interface Index RF V11 G703
Network Time Protocol
Enabled Disabled Main Server
Spare Server
6. NETWORK ELEMENT INTEGRATION TEST

SITE A

NMS radio side NE Acquisition


Expected Functionality Channel 1 Channel 0 (1+1 only)
Supervising with CT the Radio Side remote Station OK NOK OK NOK

Housekeeping Input alarms acquisition (Only if foreseen by Plant Doc.)


Alarm/User label Acquisition on CT Alarm/User label Acquisition on CT
CPI 1/ OK NOK CPI 4/ OK NOK
CPI 2/ OK NOK CPI 5/ OK NOK
CPI 3/ OK NOK CPI 6/ OK NOK

Housekeeping Output alarms Detection (Only if foreseen by Plant Doc.)


Alarm/User label Detection Alarm/User label Detection
CPO 1/ OK NOK Fail IDU OK NOK
CPO 2/ OK NOK Fail ODU CH#1 OK NOK
CPO 3/ OK NOK Fail ODU CH#0 OK NOK
CPO 4/ OK NOK

SITE B

NMS radio side NE Acquisition


Expected Functionality Channel 1 Channel 0 (1+1 only)
Supervising with CT the Radio Side remote Station OK NOK OK NOK

Housekeeping Input alarms acquisition (Only if foreseen by Plant Doc.)


Alarm/User label Acquisition on CT Alarm/User label Acquisition on CT
CPI 1/ OK NOK CPI 4/ OK NOK
CPI 2/ OK NOK CPI 5/ OK NOK
CPI 3/ OK NOK CPI 6/ OK NOK

Housekeeping Output alarms Detection (Only if foreseen by Plant Doc.)


Alarm/User label Detection Alarm/User label Detection
CPO 1/ OK NOK Fail IDU OK NOK
CPO 2/ OK NOK Fail ODU CH#1 OK NOK
CPO 3/ OK NOK Fail ODU CH#0 OK NOK
CPO 4/ OK NOK
7. RADIO FUNCTIONALITY TEST

Channel Protection Switching


Protection level Channel 1 (Forced) Channel 0 (Lockout)
Radio Protection OK NOK OK NOK
HSB Tx Protection (optional) OK NOK OK NOK
Mux/Demux Protection (optional) OK NOK OK NOK

Loopback Tests
Location Point Channel 1 Channel 0 (1+1 only)
Near End Tributary OK NOK OK NOK
Near End IDU Cable OK NOK OK NOK
Near End ODU Cable OK NOK OK NOK
Far End Tributary OK NOK OK NOK

Point to point BER loop Test


Access Duration Channel 1 Channel 0 (1+1 only)
E1 (1 min. each) OK NOK OK NOK
Ethernet Ch. (optional) OK NOK OK NOK
E1 "alarm Loss Signal" indication OK NOK OK NOK

8. HOP STABILITY TEST

2 hours BER Loop test on one tributary without error OK NOK


9. LIST OF ACTIVE ALARM
SITE ACCEPTANCE TEST PROTOCOL

SITE A
NAME:
LOCATION:

SITE B
NAME:
LOCATION:

Accepted Without pending

With pending Major Minor

Not Accepted

PENDING POINT(s)

Comments

CUSTOMER representative: ALCATEL representative:


Company: Company:
Name: Name:
Signature: Signature:

Date: Date:

You might also like