You are on page 1of 2

DATE 04-12-2019

U RUNNER STRUCTURAL CAPACITY CHECK PREP GOKUL

STRUCTURAL CHECK FOR U RUNNER


DATE 04-12-2019
U RUNNER STRUCTURAL CAPACITY CHECK PREP GOKUL
CHECK FOR WEBCRUSHING RESISTANCE

Total Dead load of the roofing = 0.24 kn/m2


Live load = 1.5 kn/m2
Wind load = 3 kn/m2

Total Load = 4.74 kn/m2

On considering 1.2 Factor of safety = 5.688 kn/m2

Length of the sheet = 1m

Width of the sheet = 0.408 m

Point load acting on the crest of sheet = 2.3 kn

CHECK FOR BENDING MOMENT :

Crest spacing of FORMDEK 75 and span = 0.18 m


of U clamp

Bending Moment acting on the "U" clamp = WL /4

= 0.10 Knm-m

Section Modulus of the "U" Clamp = 150 mm3


75 x 15 x 1.2mm thick
Grade of U clamp = 550 N/mm2

= 0.083 Knm-m
Need to check
CHECK FOR DEFLECTION:

Moment of Inertia of profile = 1869 mm4

= Wl 3
48 EI

= 11278621440
18839520000

= 0.598668195 mm

Allowable deflection ( Span /180) = 1 mm

Hence Safe