Specialty Systems
Foam Systems . . . . . . . . . . . . . . . . . . . . . . . . . 85 – 90
Aquamist® Systems . . . . . . . . . . . . . . . . . . . . . 91 – 93
TYco Fire PROTECTION Products
Leading the Way for More than 150 years
In 1881, industry pioneer Frederick
Grinnell patented the first “sensitive”
automatic fire sprinkler incorporating a
number of features still found in modern
day units. Since that time, many of the
major advancements in fire
sprinkler technology can
be attributed to Grinnell
and other leading names
in the industry that
are now part of Tyco Fire
Protection Products.
• The First Residential Sprinklers for Life Safety • Pump/Valve Skid Packages
Purposes
• Water Mist Systems for Fire Protection
• Electronic Quick Opening Accelerator for Dry
Sprinkler Systems • Valve Packages for Seawater and Harsh
Environments
• Back-to-Back CPVC Fittings for Residential Fire
Protection Tyco Fire Protection Products has made a commitment
to the world-class performance of its products and,
• Sprinkler System Design Software (SprinkCAD) as a result, has received independent approvals and
and Fluid Delivery Time Calculation Software certifications from industry agencies globally.
T yco F i r e P r ot e c t i o n P r o d u c t s
Our state-of-the-art international manufacturing facilities
have all been granted ISO 9000 approvals, and are
routinely audited by independent testing agencies for
quality and conformance. We also participate in more
than 70 National Fire Protection Association committees
and a number of international standards and
code-making bodies.
FM
Underwriters Underwriters Scientific Verband der Factory Mutual Loss Prevention
Laboratories Inc. Laboratories Inc. Services Schadenversicherer Research Certification Board
for use in Canada Laboratory Corporation in association with
AB & Lloyds
a p p l icatio n s :
Standard Spray Sprinklers are comprised of two • Office • Theaters
responses: standard and quick. Together they offer a wide Buildings • Light &
range of sprinklers from which to choose when designing
a standard coverage fire sprinkler system. • Banks Ordinary
• Factories Hazard
Standard Response Sprinklers are intended for use Occupancies
in fire sprinkler systems designed in accordance with the • Libraries
• Schools
Series TY-B bulb type sprinklers are available in a variety of Quick Response Sprinklers are designed with a
attractive finishes that blend well with their surroundings. 3mm bulb or small nickel link to react more quickly at
When in service, a small bubble in the fluid contained in the specified temperature. They are available in pendent,
the bulb compensates for normal temperature changes. upright, recessed, concealed, vertical sidewall, and
When heated, the fluid in the bulb expands and shatters horizontal sidewall styles.
the bulb, allowing water to be discharged.
The narrow profile bulbs and attractive finishes of the
Series TY-L solder type sprinklers employ a link whose Series TY-FRB provide specifiers with a wide variety of
two sections are joined by solder with a predetermined sprinklers for use in quick response applications. The
temperature rating. Heat absorbed by the link is conducted versatile Quick Response TY-FRL Series provides the
directly to the soldered joint. When the solder melts, the specifier with a solder type sprinkler for most commercial
link springs apart, releasing water that strikes the sprinkler and industrial applications.
deflector.
286°F/141°C, 360°F/182°C
(Recessed)
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
286°F/141°C
Escutcheon Style 10 • Style 20
Style 30 • Style 40
Escutcheon finish White Coated, Chrome
Plated, Brass Plated
Sprinkler Finish Natural Brass, Chrome
Plated, White Polyester,
Lead Coated
SIN TY1131, TY1231, TY2131,
TY2231, TY3131, TY3231,
TY4131, TY4231
Tech Data TFP171
T Y-FRB
Horizontal, Recessed Horizontal Sidewall & Vertical Sidewall
• Light hazard/Ordinary hazard K Factor
K =5.6 (80,6)
• 3 mm bulb Thread Size ⁄2" NPT
1
• Designed for use in applications where 5.6= UL, C-UL, FM, NYC,
S ta n da r d S p r ay S p r i n k l e r s
Approvals
aesthetics must be considered or where LPCB
building construction makes the installation Temperature 135°F/57°C, 155°F/68°C,
of standard pendent or upright sprinklers
175°F/79°C, 200°F/93°C,
impractical
286°F/141°C
• Vertical sidewall sprinkler can be installed in
Escutcheon Style 10 • Style 20
either the pendent or upright position along
a wall or the side of a beam and just below a Escutcheon finish White Coated, Chrome
Sprinkler Wrenches
smooth ceiling Plated, Brass Plated
Sprinkler Finish Natural Brass, Chrome (Recessed)
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
T Y-L
Upright, Pendent & Recessed Pendent
• All hazards K Factor
K =5.6 (80,6)
• Solder type K=8.0 (115,2)
1
3
• Discharges a hemispherical water spray Thread Size ⁄2" NPT • ⁄4" NPT
pattern in the area beneath the sprinkler Approvals UL, C-UL, FM, LPCB
• Designed for use in light, ordinary, and Temperature 165°F/74°C, 212°F/100°C,
extra hazard, commercial occupancies such 280°F/138°C
as banks, hotels, shopping malls, factories, Escutcheon Style 20 • Style 30
refineries, chemical plants, etc. Sprinkler Wrenches
Escutcheon finish White Coated, Chrome
Plated, Brass Plated
S ta n da r d S p r ay S p r i n k l e r s
(Recessed)
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
T Y-FRL
Upright, Pendent & Recessed Pendent
• Light hazard/Ordinary hazard K =2.8 (40,3) • K=5.6 (80,6)
K Factor
light hazard K=2.8 (40,3) K=8.0 (115,2)
• Solder type 1 3
Thread Size ⁄2" NPT • ⁄4" NPT
• Typically used in hotels, motels, office Approvals .8=L, C-UL, NYC •
2
buildings and other commercial and 5.6=UL, C-UL, FM, NYC,
industrial applications LPCB •
8.0= UL, C-UL, FM, NYC
Temperature 165°F/74°C, 212°F/100°C
Sprinkler Wrenches
Escutcheon Style 20
Escutcheon finish White Coated, Chrome (Recessed)
S ta n da r d S p r ay S p r i n k l e r s
Sprinkler Finish Natural Brass, Chrome
Plated
SIN TY1121, TY1221, TY3121
TY3221, TY4121, TY4221
Tech Data TFP130
Horizontal Sidewall
• Solder type K Factor
K =5.6 (80,6)
• Light hazard/Ordinary hazard Thread Size ⁄2" NPT
1
• Designed for compact installation along a Approvals UL, C-UL, FM, NYC
wall or on the side of a beam just beneath a Temperature 165°F/74°C, 212°F/100°C
smooth ceiling
Sprinkler Finish Natural Brass, Chrome
• Generally used in lieu of pendent or upright Plated
sprinklers because of aesthetics, building SIN TY3321
construction, where piping across the ceiling Sprinkler Wrench
Tech Data TFP140
is not desirable
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
I LLUS I O N ™
Concealed Standard Coverage Pendent Sprinklers
• Extra large orifice/Special hazard K Factor
K =11.2 (161,3)
• Coverage per NFPA 13 Thread Size ⁄4" NPT 3
• Available with optional dust and air seal Approvals UL, C-UL
• The ILLUSION is concealed in an enclosed Temperature 160°F/71°C, - Sprinkler
escutcheon plate with flat cover for use in 139°F/59°C - Cover Plate,
those applications where architecturally 212°F/100°C - Sprinkler
165°F/74°C - Cover Plate
sensitive areas such as casinos, hotel lobbies,
office buildings, churches and restaurants Cover Plate Finish Chrome, Brass, Signal
White, Grey White, Pure
White, Custom
SIN TY5521
Tech Data TFP184
S ta n da r d S p r ay S p r i n k l e r s
Sprinkler Wrench
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Ex tENded Coverage Sp r i n k l e r s
a p p l icatio n s :
• Office • High-Piled
Extended Coverage Sprinklers are intended for the
protection of areas larger than those specified in standard
Buildings Storage
installation rules and for specific light, ordinary, or extra • Hotels • “Big-Box”
hazard occupancies. Extended coverage sprinklers are
available in both standard response (EC) and quick • Hospitals Retailing
response (QR-EC). They are available in upright, pendent,
horizontal sidewall and recessed horizontal sidewall. These • Libraries
sprinklers are typically used in hotels, restaurants, office
buildings, warehouses, and other areas where it is desirable
to reduce the overall number of required sprinklers.
Lead Coated
SIN TY5137, TY5237,
TY6137, TY6237
Tech Data TFP220
EC-8
Pendent & Recessed Pendent
• Light hazard K Factor
K =8.0 (115,2)
• 3 mm bulb Thread Size ⁄4" NPT
3
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
SIN TY3232
Tech Data TFP228
e x t e n d e d co v e r ag e S p r i n k l e r s
SIN TY3302
Tech Data TFP298
T Y-FRB
Horizontal & Recessed Horizontal Sidewall
• Light hazard K Factor
K =5.6 (80,6)
• 3 mm bulb K=8.0 (115,2)
1 3
• Two-piece escutcheon converts sidewall Thread Size ⁄2" NPT • ⁄4" NPT
sprinklers into low profile sprinkler Approvals .6= UL, C-UL, FM, NYC,
5
assemblies with coverage areas up to VdS • 8.0= UL, C-UL, FM,
16' x 22' (4,9 m x 6,7 m) for K=5.6 and NYC
16' x 24' (4,9 m x 7,3 m) for K=8.0 Temperature 135°F/57°C, 155°F/68°C,
Sprinkler Wrenches
• Provides 3⁄4" NPT (19,1 mm) of horizontal 175°F/79°C
adjustment from the recessed sidewall Escutcheon Style 10 • Style 20 (Recessed)
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
T Y-FRL
Horizontal Sidewall
• Light hazard K =5.6 (80,6) •K=8.0
K Factor
• Solder type (115,2)
3 1
• Designed for use in commercial occupancies Thread Size ⁄2" NPT • ⁄4" NPT
such as churches, restaurant seating areas, Approvals UL, C-UL, FM, NYC
hotels, educational facilities, offices, etc. Temperature 165°F/74°C
• Coverage up to 16 feet (4,9 m) wide by Sprinkler Finish Natural Brass, Chrome
24 feet (7,3 m) long, they are designed Plated
for installation along a wall or the side of SIN TY3322, TY4322 Sprinkler Wrench
a beam and just beneath a smooth, flat,
e x t e n d e d co v e r ag e S p r i n k l e r s
CHEC
Concealed Horizontal Extended Coverage Sidewall
• Light hazard K Factor
K =8.0 (115,2)
• 3 mm bulb Thread Size ⁄4" NPT
3
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Sprinkler Wrench
• Maximum 20' x 20' (6,1 m x 6,1 m) QR Listing Approvals UL, C-UL, NYC
• Concealed in an enclosed escutcheon plate Temperature 155°F/68°C - Sprinkler
with flat cover for use in those applications 139°F/59°C - Cover Plate,
e x t e n d e d co v e r ag e S p r i n k l e r s
where aesthetics is a primary consideration 200°F/93°C - Sprinkler
165°F/74°C - Cover Plate
• Separable, two-piece design of the mounting
Cover Plate Finish Chrome Plated, Brass
cup and cover allows installation of the
Plated, Signal White,
sprinklers and pressure testing of the fire Grey White, Custom
protection system prior to installation of a
SIN TY3532
suspended ceiling or application of the finish
coating to a fixed ceiling Tech Data TFP260
Sprinkler Wrench
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
www.tyco-fire.com
800-558-5236
Copyright © 2012 Tyco Fire Products LP. All Rights Reserved.
TFP2012002
Storage Sprinklers
a p p l icatio n s :
Storage Sprinklers are intended for use in specific • High-Piled • Warehouse
STORAGE Sprinklers
applications, including the protection of high-piled and
rack storage of a variety of finished goods. These sprinklers
Storage • High Challenge
can provide more water at lower pressures or more water
• In-Rack Storage Occupancies
over a greater area of coverage. In many instances, use of
the storage sprinklers can eliminate the need for additional
in-rack sprinklers.
Intermediate level (in-rack) sprinklers are designed for use such as beneath open gridded catwalks. These sprinklers
in rack storage sprinkler systems, where their thermally are intended for use in fire sprinkler systems designed in
sensitive elements must be shielded from the water spray of accordance with the standard installation rules recognized
higher elevation sprinklers that could operate during a fire. by the applicable Listing or Approval agency (e.g., FM
Intermediate Level Sprinklers are also used in applications approval and UL Listing is based on NFPA requirements).
ESFR-17
Pendent
• Early Suppression, Fast Response (ESFR) K Factor
K =16.8 (241,9)
• Solder type Thread Size ⁄4" NPT
3
• Primarily designed for use in ceiling only Approvals L, C-UL, FM, NYC, LPCB,
U
sprinkler systems VdS
• Use of this sprinkler is especially Temperature 165°F/74°C, 214°F/101°C
advantageous as a means of eliminating the Sprinkler Finish Natural Brass
use of in-rack sprinklers when protecting
SIN TY7226
rack storage arrangements Sprinkler Wrench
Tech Data TFP315
• Operates at lower pressure than ESFR-1
S to r ag e S p r i n k l e r s
Upright
• Early Suppression, Fast Response (ESFR) K Factor
K =16.8 (241,9)
• Solder type Thread Size ⁄4" NPT
3
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
ESFR-1
Pendent
• Early Suppression, Fast Response (ESFR) K Factor
K =14.0 (201,6)
• Solder type Thread Size ⁄4" NPT
3
• Designed for the protection of rack storage Approvals UL, C-UL, FM, NYC, LPCB,
• Eliminates many of the requirements for VdS
in-rack sprinklers Temperature 165°F/74°C, 214°F/101°C
• Direct attack on burning fuel by improved Sprinkler Finish Natural Brass
S to r ag e S p r i n k l e r s
heavy sprinkler discharge SIN TY6226
• Patented frame design substantially reduces Tech Data TFP318
the frame shadow effects that often produce Sprinkler Wrench
non-uniformity in spray pattern
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
• Full-scale fire testing has shown that the Approvals UL, C-UL, FM, NYC
Ultra K17 can control fires with commodities Temperature 155°F/68°C, 200°F/93°C
up to Group A plastics, and eliminate the
Sprinkler Finish Natural Brass
need for in-rack sprinklers
SIN TY7153
• Approved for storage heights of 25' (7,6 m) Sprinkler Wrench
and building heights to 30' (9,1 m) Tech Data TFP330
Temperature 286°F/141°C
Sprinkler Finish Natural Brass
Tech Data Contact Tyco for details
Sprinkler Wrench
K17-231
Pendent & Upright
• 5 mm bulb K Factor
K =16.8 (241,9)
• Very large orifice sprinkler for use in Thread Size ⁄4" NPT
3
Sprinkler Wrench
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
E LO - 2 3 1 F R B
Pendent & Upright
• 3 mm bulb K Factor
K =11.2 (161,3)
• Extra large orifice sprinklers proven for Thread Size ⁄4" NPT
3
E LO - 2 3 1
Pendent & Upright
• Solder type K Factor
K =11.2 (161,3)
S to r ag e S p r i n k l e r s
• Extra large orifice sprinklers proven for Thread Size ⁄2" NPT • ⁄4" NPT
1 3
storage occupancies through full-scale fire Approvals UL, C-UL, FM, NYC
testing
Temperature 165°F/74°C, 212°F/100°C,
• Designed to control high challenge fires 286°F/141°C
with relatively low required pressures
Sprinkler Finish Natural Brass, Chrome
• Can be used as intermediate level version Plated, Lead Coated, Wax
by adding a guard and shield Coated, Wax over Lead
Coated
SIN TY5111, TY5211, TY5811 Sprinkler Wrench
Tech Data TFP340
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
T Y-b
Pendent & Upright, Intermediate Level
• 5 mm bulb K Factor
K =5.6 (80,6)
• Intermediate level (in-rack) with shield K=8.0 (115,2)
3 1
• Factory assembled unit having an integral Thread Size ⁄2" NPT • ⁄4" NPT
water shield Approvals UL, C-UL, FM, NYC
• Used where sprinkler guards are not required Temperature 135°F/57°C, 155°F/68°C,
175°F/79°C, 200°F/93°C,
286°F/141°C, 360°F/182°C
Sprinkler Finish Natural Brass, Lead
Coated, Wax Coated, Wax Sprinkler Wrench
over Lead Coated
SIN TY3153, TY3251, TY4153,
TY4251
Tech Data TFP351
ty - frb
Pendent & Upright, Intermediate Level
• 3 mm bulb K Factor
K =5.6 (80,6)
S to r ag e S p r i n k l e r s
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
ty - fr l
Pendent & Upright, Intermediate Level
• Solder type K Factor
K =5.6 (80,6)
• Intermediate level with shield K=8.0 (115,2)
1 3
• Factory assembled unit having an integral Thread Size ⁄2" NPT • ⁄4" NPT
water shield Approvals UL, C-UL, FM, NYC
• Used where sprinkler guards are not required Temperature 165°F/74°C
Sprinkler Finish Natural Brass, Chrome
Plated
Sprinkler Wrench
SIN TY3123, TY3221, TY4123,
TY4221
Tech Data TFP355
S to r ag e S p r i n k l e r s
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
G1
S1
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
a p p l icatio n s :
• Single Family • Hotels
Homes • Beamed
• Apartments Ceilings
• Student • Sloped Ceilings
• Features BlazeMaster® CPVC pipe and fittings, in the industry. Other advantages are listings for beam
making installation quick, easy, flexible, and ceilings and for sloped ceilings. These unique features avoid
affordable obstruction to the sprinkler's discharge pattern without
adding additional sprinklers.
• Tyco’s exclusive ten-year limited warranty lets you
install with confidence
NFPA 13
(Recessed)
r a p i d r e s p o n s e™ S p r i n k l e r s
NFPA 13 (Recessed)
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
- wet and dry pipe residential sprinkler Approvals UL, C-UL, NYC
systems for one/two-family dwellings
Temperature 155°F/68°C, 175°F/79°C
and mobile homes per NFPA 13D
Escutcheon Style 20
- wet and dry pipe residential occupancies
Sprinkler Finish White Polyester, Chrome
up to and including four stories in height
Plated, Natural Brass
per NFPA 13R
SIN TY1334
- wet and dry pipe sprinkler systems for Sprinkler Wrenches
the residential portions of any occupancy Tech Data TFP410
r a p i d r e s p o n s e™ S p r i n k l e r s
per NFPA 13
Flush Pendent
• Solder type K Factor K=4.2 (60,5)
• Intended for use in the following scenarios: Thread Size ⁄2" NPT
1
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
- one/two-family dwellings
and mobile homes per NFPA 13D,
- residential occupancies up to and includ-
ing four stories in height per NFPA 13R
- the residential portions of any occupancy
per NFPA 13
r a p i d r e s p o n s e™ S p r i n k l e r s
• Intended for use in the following residential Tech Data TFP461 (Recessed)
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
- wet pipe residential sprinkler systems Approvals UL, C-UL, FM, NYC
for one/two-family dwellings and mobile
Temperature 155°F/68°C, 175°F/79°C,
homes per NFPA 13D
139°F/59°C - Cover Plate
- wet pipe residential occupancies up to
Escutcheon Style 30
and including four stories in height per
NFPA 13R Escutcheon finish White, Chrome, Brass
Sprinkler Finish Natural Brass, Chrome
- wet pipe sprinkler systems for the
Plated, Signal White
residential portions of any occupancy
per NFPA 13 cover plate Finish Signal White, Chrome,
Custom Sprinkler Wrenches
SIN TY4234
(Recessed)
a p p l icatio n s :
Dry Sprinklers have been specifically designed for areas in • Unheated Warehouses
Dry Sprinklers
which the sprinkler may be subjected to freezing conditions.
These sprinklers have been developed for use in all standard • Freezing Conditions
applications, as well as multiple unique scenarios. Tyco Dry
Sprinklers are available in both quick and standard response,
• Loading Docks
and come in a variety of finishes. These features, and the
• Covered Exterior Platforms
advanced engineering in the development of these sprinklers,
offer the industry the most complete line of dry sprinklers
available. Most models are listed in lengths up to 4'-0". The
extended escutcheon option has up to 3" of adjustment.
• Designed for use in applications requiring dry Plated, White Polyester Sprinkler Wrench
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
d s - 1 Sta in l e s s Stee l
Pendent
• 5mm and 5mm Glass Bulb
K Factor
K =5.6 (80,6)
• Quick and Standard Response inlet THREAD 1" NPT (Standard Order)
• The stainless-steel construction of these connection ISO 7-R1
sprinklers extends the life of a sprinkler beyond Approvals L, C-UL, LPCB, CE
U
that of traditional copper alloy sprinklers Temperature 135°F/57°C, 155°F/68°C,
exposed to corrosive atmospheres 175°F/79°C, 200°F/93°C,
• Wet-pipe, dry-pipe, or preaction installations 286°F/141°C, 360°F/182°C
escutcheon finish Stainless Steel
• Designed for use in applications where
sprinklers and/or connecting piping may Sprinkler Finish Stainless Steel
be exposed to freezing conditions, or the SIN TY3230, TY3250
Sprinkler Wrench
sprinkler system is seasonally drained Tech Data TFP560
• Special assembly provides a seal at the main
pipe to prevent water from entering the
assembly until the sprinkler operates
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
ds-ECC
Extended Coverage Concealed Pendent
• EC light hazard/EC ordinary hazard K Factor
K =5.6 (80,6)
• 3 mm bulb inlet THREAD 1" NPT (Standard Order)
• Lengths to 48" (1220 mm) connection ISO 7-R1
d ry S p r i n k l e r s
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
DS B - 2
Dry Sprinkler Boot (For Use With TFP Dry Type Sprinklers)
• Helps to close the air gap created by the Includes 1 Boot, 2 Strap Ties, and
clearance hole through a wall or ceiling 1
/3 oz. of Adhesive
through which the dry type sprinkler has (quantity of adhesive is
penetrated sufficient for installing 1 Boot)
• Helps to stop the air exchange between the Tech Data TFP591
inside and outside of the freezer (or any other
type of similar construction) to help prevent
transfer of moist air into the freezer space
G5
DS-1 Dry Sprinkler Guards
• The TYCO Model G5 Sprinkler Guards are Approvals UL
designed to be used in areas that make Finish Zinc Chromate
d ry S p r i n k l e r s
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
a p p l icatio n s :
Special Purpose Sprinklers are intended for use
in specific applications, including the protection of
• Attic Spaces • High
combustible concealed spaces and areas subject to corrosion. • Retail Windows Temperature
Also, these installations may need consideration for more Conditions
water at lower pressures, or more water over a greater area. • High Security
Institutions • Corrosive
Conditions
• Minimal Water
Damage
Conditions
K Factor
K =4.2 (60,5), K=5.6 (80,60),
K=8.0 (115,2)
1
Thread Size ⁄2" NPT
3
⁄4" NPT
Approvals UL, ULC
Temperature 200°F/93°C, 212°F/100°C
Sprinkler Finish Natural Brass Hip
SIN TY4180, TY4181, TY4182 TY3180,
TY3181, TY3182 TY2180, TY2181,
TY2182 TY3183, TY3184, TY3185
TY3187, TY3190, TY2190 Single Directional
Tech Data TFP610
Application
Spray Patterns
special purpose Sprinklers
BB
Single
HIP Directional
STAGGERED
SPACING WHEN
MORE THAN
ONE ROW
SD AP MINIMUM
SEPARATION Attic
Attic Plus
15'-0" (4,6 m)
Plus
(AP)
Sprinkler Wrenches
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
CC2
Combustible Concealed Space Sprinklers™,, Upright
• 3 mm bulb K Factor
K =4.2 (60,5)
• Specific application sprinklers K=5.6 (80,6)
1
• Provides protection of specific light Thread Size ⁄2" NPT
hazard combustible, as well as Approvals UL
non-combustible, concealed spaces Temperature 175°F/79°C
requiring sprinkler protection
Sprinkler Finish Natural Brass
• Meets NFPA® Requirements for Specialty SIN TY2189, TY3189
Listed Sprinklers in Combustible Concealed
Tech Data TFP632 Sprinkler Wrench
Spaces
• Allows the use of BlazeMaster® CPVC pipe
• Increased spacing from 10 ft. (3,1 m) to
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
• Only UL tested sprinklers that can protect Approvals UL, C-UL, ULC, NYC
glazing in a wall or window and allow it to Temperature 155°F/68°C, 200°F/93°C
maintain its mechanical equivalent rating
Sprinkler Finish White Polyester Coated,
up to two hours
Chrome Plated, Natural
• First sprinklers to be UL/C-UL Listed, ICC-ES, Brass
and ULC Listed & Approved for maintaining a SIN TY3388, TY3488
rated assembly
Tech Data TFP620
• Pendent allows installation farther away from
the glass than the sidewall
• Sidewall permits the window mullion to
act as a baffle, allowing the sprinklers to be
spaced closely together, if necessary
• Provides the only UL tested option when Sprinkler Wrench
I LLUS I O N ™
Concealed Standard Coverage Pendent Sprinklers
• Extra large orifice/Special hazard K Factor
K =11.2 (161,3)
• Coverage per NFPA 13 Thread Size ⁄4" NPT 3
• Available with optional dust and air seal Approvals UL, C-UL
• The ILLUSION is concealed in an enclosed Temperature 160°F/71°C, 212°F/100°C
escutcheon plate with flat cover for use in Sprinkler Finish Cover Plate:
those applications where architecturally Chrome, Brass,
sensitive areas such as casinos, hotel lobbies, Signal White, Grey White,
special purpose Sprinklers
Sprinkler Wrench
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Sprinkler Wrench
I s s u e D Q u a rt z o i d ®
High Temperature, Upright & Pendent
• Standard coverage K Factor
K =5.6 (80,6)
• All hazard K=8.0 (115,2)
31
• 11 mm bulb Thread Size ⁄2" NPT • ⁄4" NPT
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Sprinkler Wrenches
(Recessed)
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Sprinkler Accessories
a p p l icatio n s :
Sprinkler Accessories are for use with the sprinklers • Improve • Onsite Emergency
and nozzles described in this catalog. Escutcheons are Appearance Storage Supply
referenced by a style number and are available in brass,
chrome or white finish. Please refer to the technical data
• Conceal • Protection from
sheet for additional information and a listing of what Clearance Holes Mechanical or
finishes are available. Physical Damage
Style 401
installation
• Deep, two-piece, adjustable
• Available for 3⁄4" NPT Style 60
S p rink l er He a d C a binet
3, 6 or 12 Capacity
• Provides storage for spare sprinklers Tech Data TFP785
and sprinkler wrench
• Spare sprinklers facilitate the prompt
replacement of operated or damaged
sprinklers and return of fire protection
system to service as soon as possible
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
a p p l icatio n s :
• Flammable • Fuel Storage
Liquid Tanks • Gas Turbines
& Operations
• Historic Sites &
• Equipment or Museums
Processes that
Require Special • Industrial
Designs Process
Equipment
• Cable Trays
EA-1
Automatic Protectospray Directional Spray Nozzle
• Bulb type frangible element for use in closed K Factor K=1.4 (20,2), K=2.8 (40,3)
head systems K=5.6 (80,6)
1
• Discharges a filled cone of water droplets at Thread Size ⁄2" NPT
relatively low velocity Approvals UL, C-UL, FM
• Spray angles available: 65°, 80°, 95°, 110°, Temperature 1 35°F/57°C, 175°F/79°C,
125°, 140°, 160°, and 180° 250°F/121°C, 325°F/163°C,
400°F/204°C, 500°F/260°C
Sprinkler Finish Bronze: Natural Finish,
Lead Coated, Chrome
Sprinkler Wrench
Plated, Corrosion proof
Wax Coated Bronze
Tech Data TFP800
HV ”High Velocit y”
N o z z l e s a n d acc e s s o r i e s
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
AM 4 A Q UAM I S T ®
Open Type
• Open, directional mist nozzles K Factor K=0.24 (3,5)
• Approved for protection of gas turbines (FM) Thread Size ⁄2" NPT
1
AM 1 0 A Q UAM I S T ®
Open Type
• Open mist nozzles K Factor K=0.24 (3,5)
• Designed for use in water mist protection Thread Size ⁄2" NPT
1
n o z z l e s a n d acc e s s o r i e s
11,6 bar) Sprinkler Wrench
• For use in “low pressure” mist applications
• Mist represents latest in fire protection
• Minimum operating pressure is 170 psi
technology
(11,6 bar)
AM 2 4 A Q UAM I S T ®
Open Type
• Listed and Approved for Marine Type K Factor 4.7 lpm/bar 1/2,
Approved by Lloyds, USCG, DNV, American 0.33 gpm/psi 0.5
Bureau of Shipping, MCA, Germanischer Thread Size ⁄2" NPT 1
Lloyd, Bureau Veritas
Approvals UL
• Maximum Distance between nozzles (to
Temperature 135°F/57°C, 155°F/68°C,
plane of protection) - Vertical Clearance
175°F/79°C, 200°F/93°C
Nozzle Spacing
–1 m to 3.5 m nozzles - 4.0 meter spacing Sprinkler Finish Natural Brass, Chrome
–3.5 m to 5.0 m nozzles - 3.5 meter spacing Plated, White Polyester
–5.0 m to 10.0 m nozzles - 3.0 meter spacing Tech Data TD1172
Sprinkler Wrench
• Intended Applications – IMO Mandated
Local Application System for Protection of • Nozzle pressure: 175-250 psi
Class A Machinery Spaces (12,1 to 17,2 bar)
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
c o o l in g T o wer n o z z l e
Type 1 and 2
• Intended for use in fire protection systems K Factor K=2.9 (42,0)
for cross flow cooling towers with Thread Size ⁄4" NPT
3
combustible fill sections
Approvals UL, FM
• Open nozzle design for use in water spray
Sprinkler Finish Bronze or Stainless Steel
deluge system
Tech Data TFP830
• Installed under the distribution basin, they
discharge water in a relatively narrow,
elongated spray pattern Sprinkler Wrench
B lo w - Off P l u g s
Plugs for Protectospray® Nozzles or Open Sprinklers
• Intended for use in applications where K Factor K=5.6 (80) • K=8.0 (115)
protection is required against infestation 1
Thread Size ⁄2" NPT or 17⁄32" NPT
or accumulation of debris within the orifice
Material EPDM
of an open Protectospray Nozzle or open
sprinkler Tech Data TFP890
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Butterfly Valve to
Control Water Supply
to System
w e t s ys t e m va lv e s & d e v i c e s
Water Supply
AV-1
Alarm Valve
• AV-1Alarm Valves may be installed vertically Tech Data TFP910
or horizontally
• Groove x Groove, Flange x Flange, • Optional Retard Chamber used in
Flange x Groove Alarm Valves are divided installations subject to variable pressure
seat ring, rubber-faced clapper, check type, (generally associated with public water
water flow alarm valves supplies) to help prevent false alarms
• For use in wet pipe (automatic sprinkler) fire • Available pre-assembled with modular trim
protection systems to provide a quick and convenient method
• Automatically actuates electrically and/or for trimming valve risers. Contact TFP for
hydraulically operated alarms when there details
is a steady flow equivalent to the discharge • Maximum rated working pressure is
rate for one or more sprinklers 300 psi (20,7 bar)
• Listings and Approvals:
UL, C-UL, & FM
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
C V-1FR
Riser Check Valve
• Sizes 2" (DN50) through 12" (DN300) Tech Data TFP950
• Intended for use in a wet type automatic
sprinkler system riser • Standard seal is grade “E" EPDM
• Furnished with grooved ends that are • Maximum rated working pressure is
compatible with grooved pipe and 300 psi (20,7 bar)
couplings • Listings and Approvals:
• Can be installed with ANSI class 150 or 300 UL, C-UL, & FM
Flanges utilizing flange adapters
• Designed with a removable cover for ease
of field maintenance
Riser Manifolds
w e t s ys t e m va lv e s & d e v i c e s
513D (13D), 513D/R (13D/R) and 513 (13)
• Available in different configurations and Tech Data TFP960 & TFP962
variety of sizes allowing a cost effective
and easy transition to check valves, control
valves, and system piping • 513 (13):
• May be installed either horizontally (flow – Available sizes: 1-1/2" thru 6"
switch on top) or vertically (flow going up) (DN40 thru DN150)
• 513D (13D) and 513D/R (13D/R): – Provides the necessary water
flow alarm, pressure gauge, alarm
– Available sizes: 1", 1-1/
2", and 2"
test orifice, drain, and sight glass
(DN25, DN40, and DN50)
equipment in a single assembly for use
– Provides the necessary water flow in NFPA 13 sprinkler systems
alarm, pressure gauge, and drain
• Maximum rated working pressure is
equipment in a single assembly for use
175 psi (12,1 bar)
in NFPA 13D or 13R residential sprinkler
systems
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Resi-Riser
Residential
• Sizes 1"- 2" (25-50 mm) Tech Data Contact Tyco for details
• Compact, pre-assembled, ready to install
sprinkler riser • Molded mounting points allow for fast
• Brass construction for use in potable water and easy left or right hand installation
supply • Available with or without pressure relief
• Integral test and drain assembly, flow valve or flow switch retard mechanism
switch with retard mechanism, 300 psi features
gauge, and check valve • Maximum rated working pressure is
• Compact size allows for easy installation 175 psi (12,1 bar)
between 2" x 4" (50-100 mm) studs
w e t s ys t e m va lv e s & d e v i c e s
WMA-1
Water Motor Alarm
• Hydraulically operated outdoor alarm for Tech Data TFP921
use with appropriate fire protection system
valves (alarm, dry, deluge) • Can accommodate range of wall
• Supplied by dedicated outlet in valve trim thicknesses from 2" to 18" (50 to 450 mm)
line or retard chamber • Furnished with approved 3⁄4" (20 mm)
• Uses energy-efficient lightweight impeller Y-strainer for use in alarm line
design capable of producing very high • Maximum rated working pressure is
sound level 300 psi (20,7 bar)
• Corrosion-resistant aluminum alloy gong, • Listings and Approvals:
gong-mount, and water motor housing UL, ULC, FM, VdS, & LPCB
• Polymer bearings do not require lubrication
• Must be mounted to a rigid wall surface
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Butterfly Valve to
Control Water Supply
to System
Water Supply
d ry s ys t e m va lv e s & d e v i c e s
DPV-1
Dry Pipe Valve – 21⁄2" thru 6"
• Available sizes: 21⁄2" (DN65), 3" (DN80), Tech Data TFP1020
4" (DN100) and 6" (DN150)
• External reset differential dry pipe valves • Rated for use at a maximum service
• Available as Flange x Flange, Flange x pressure of 250 psi (17,2 bar)
Groove, or Groove x Groove • Listings and Approvals: UL, C-UL, and FM
• Unique, offset clapper design minimizes NYC under MEA 172-02-E (4 and 6 inch)
valve size and weight
• Used to supply sprinkler installations in
which sprinklers are subjected to freezing
conditions (40˚F / 4˚C or less)
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
QRS
Electronic Accelerator
• Maximum working air pressure Tech Data TFP1100
70 psi (4,8 bar)
• Quick opening device intended to reduce • Operation of the dry pipe valve within
the time for dry pipe valve operation four seconds -independent of various
following the operation of one or more combinations of system initial air pressures,
automatic sprinklers system volumes, or sprinkler K Factors
• Automatically adjusts to both small and • Proven electronic release technology as
slow changes in system pressure, but trips used for electrically operated deluge and
with a steady drop in pressure (as in the preaction systems
case of sprinkler operation) • Battery back-up in the event of primary
• Can be used to retro-fit existing
d ry s ys t e m va lv e s & d e v i c e s
power failure
mechanical accelerators • Eliminates re-setting problems often
• Fully assembled package includes switch, incurred with traditional mechanical
solenoid, control panel, and accelerator accelerators
trim pipe and fittings • Listings and Approvals: UL, and FM
• Built-in low and high pressure alarm
supervision
VIZOR
Electronic Dry Pipe Accelerator
• Direct mounting to the riser Tech Data TFP1105
• Installation consistent with the installation
of mechanical devices • Electronically self-supervising technology,
similar to that used in typical alarm panels
• Easy test-and-reset function, as compared
for alarm and detection systems
to mechanical accelerators
• Maximum water pressure
• Operation of a dry pipe valve within four
300 psi (20,7 bar)
seconds — over a wide range of system
volumes, system initial air pressures, and • Battery back-up in the event of primary
sprinkler K-factors power failure
• Built-in low-pressure and high pressure • Air pressure
alarm supervision 10 psi (0,7 bar) to 65 psi (4,5 bar)
• Listings and Approvals: UL, ULC, & FM
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
AMD-1
Air Maintenance Device, Pressure Reducing Type
• Field adjustable Tech Data TFP1221
• Used in systems where compressed air
source is available • Listings and Approvals:
• Used in systems in which the air supply is UL, C-UL, & FM Approved & NYC Approved
at a higher pressure than is desired for a under MEA 206-02-E
sprinkler system or dry pilot line system
AMD-2
d ry s ys t e m va lv e s & d e v i c e s
AMD-3
Nitrogen Maintenance Device, High Pressure (Cylinder) Reducing Type
• Field adjustable Tech Data TFP1241
• Used in conjunction with a cylinder of
high pressure nitrogen to control the • Listings and Approvals:
nitrogen pressure in a sprinkler system UL, C-UL, & FM Approved & NYC Approved
or a dry pilot line detection for deluge under MEA 206-02-E
systems
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
a pp l i c a t i o n s :
Legend:
1 Deluge Valve (DV-5) 7 Pressure Switch
2 Isolation Valve 8 Water Motor Gong
3 Diaphragm Supply Valve 9 Releasing Panel
4 Manual Control Station 10 Spray Nozzle
5 Automatic Shut-off Valve 11 Smoke/Heat Detector
6 Automatic Drain Valve 12 Solenoid Valve
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
d e lu g e & p r e ac t i o n s ys t e m s
system from a fire opens the deluge valve,
allowing water to flow into the sprinkler
piping system and to be discharged only
from those sprinklers that have been Legend:
1 Deluge Valve (DV-5) 9 Releasing Panel
operated by heat over the fire. Loss of 2 Isolation Valve 10 Sprinkler
supervisory pressure from the system 3 Diaphragm Supply Valve 11 Smoke/Heat Detector
4 Manual Control Station 12 Solenoid Valve
piping as a result of damaged sprinklers or
5 Automatic Shut-off Valve 13 Air Supply Inlet
broken piping will activate a trouble alarm 6 Automatic Drain Valve 14 Pressure Switch (Air)
to indicate impairment of the system. The 7 Pressure Switch Water 15 Check Valve
8 Water Motor Gong
deluge valve will not open due to loss of
supervisory pressure.
Tech Data TFP1410 – Wet Pilot Actuation
Tech Data TFP1415 – Dry Pilot Actuation
Tech Data TFP1420 – Electric Actuation
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
The unique diaphragm style design of the DV-5 Valve allows external
resetting. Deluge or preaction systems can be reset without having
to open a valve handhole cover and manually reposition a clapper
or latch mechanism. Simply repressurizing the diaphragm chamber
resets the valve.
• Available sizes:
11⁄2" (DN40), 2" (DN50), 3" (DN80), 4" (DN100), 6" (DN150), and 8" (DN200)
• Vertical or horizontal installation
• One internal working part
d e lu g e & p r e ac t i o n s ys t e m s
• No linkage or clapper assembly
• Light weight ductile iron body
• Available with deluge and single & double interlock preaction trim
• Internally & externally coated
• Features external resetting
• Diaphragm operation
• For most seawater & brackish water supplies
• For deluge, preaction & foam systems
• Available as Flange x Flange, Flange x Groove, or
Groove x Groove body styles
• Rated for 250 psi service
• Listings and Approvals: UL, C-UL, & FM
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
systems:
- Electric Actuation
- Dry Pilot Actuation
- Wet Pilot Actuation
• Aesthetically pleasing appearance
• Professionally assembled
• Minimal installation time
• Internally pre-wired
• UL/ULC/FM components
• Custom manufactured
• Model DV-5 deluge valve (standard)
• All gauges and panel display are visible
externally
• UL, C-UL Listed, FM Approved
• The Red-E-Cabinet is constructed of 14 gauge
steel, and is free-standing. The standard paint
finish is bright red
Tech Data TFP1300 – Deluge Systems All Four Side Panels
Tech Data TFP1400 – Preaction Systems Easily Removed For
Ease of Maintenance
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
service Supply
Pressure
Supply
Pressure
Reset
Knob
Gauge Gauge
Inlet Diaphragm
pressure”, i.e., 80 to 225 psi (5,5 to 15,5 bar) Pressure Chamber Pressure
Gauge
Gauge
Exit Flow
Sensing
• Rated for use at a maximum pressure of Line
RV-1
g e n e r a l p u r p o s e va lv e s
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
BFV-N
Grooved Butterfly Valve – 21⁄2" thru 10" (DN65 thru DN250)
• Indicating type valves provide visual Tech Data TFP1510
indication of whether the valve is open or
closed • Rated for use at a maximum pressure of
• Cut groove inlet and outlet connections 300 psi (20,7 bar), or 175 psi (12,0 bar) for
the 10" model
• Suitable for use with grooved pipe
couplings that are listed or approved for • Listings and Approvals:
fire protection service UL, C-UL, FM, Calif. State Fire Marshall
g e n e r a l p u r p o s e va lv e s
• Indicating type valves provide visual Tech Data TFP1520
indication of whether the valve is open or
closed • Rated for use at a maximum pressure of 250
• Lug connections psi (17,2 bar), or for dead end service the
maximum pressure is 200 psi (13,8 bar)
• Suitable for use installation between
ANSI Class 125 or 150 flanges without the • Listings and Approvals:
need for flange gaskets UL, ULC, FM, Calif. State Fire Marshall
Tr i m V a lv e s
• Designed for general service such as Tech Data Contact Tyco for details
shut-off, throttling, or drain valves
• Provide positive shut-off under normal
operating conditions
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
DP-1
Dry Pilot Actuator
• Dry Pilot Actuator is an auxiliary releasing Tech Data TFP1380
device
• Rated for use at a maximum water supply
• When the Model DP-1 actuates, it permits
pressure of 250 psi (17,2 bar) and a
water pressure to be released from the
maximum system air (or nitrogen) pressure
deluge or preaction valve differential
of 50 psi (3,4 bar)
chamber, thereby allowing the deluge or
preaction valve to open • Listings and Approvals: UL, ULC, FM, and
LPCB
• Designed for Preaction Valves having
double interlock electric/pneumatic
release
ASV-1
Automatic Shut-Off Valve, Trim Component
• Intended for use with the Model DV-5 Tech Data TFP1384
Deluge Valve in deluge and preaction
systems
• Prevents inadvertent resetting of the DV-5
Valve
• Maximum Working Water Pressure:
g e n e r a l p u r p o s e va lv e s
FSV-1
Fail-Safe Valve, Trim Component
• Intended for use with the Model DV-5 Tech Data TFP1386
Deluge Valve in certain types of trim
arrangements for deluge and preaction
systems
• Prevents inadvertent resetting of the DV-5
Valve
• Maximum Working Water Pressure:
250 psi (17,2 bar)
• Listings and Approvals: UL, C-UL, & FM
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
F e at u r e s :
• Automatic • Reduce
Quarterly Flow Accidental
Switch Tests Per Manual
Specialt y Items
Specialty Items complement the components used in NFPA 25 Shut-Off &
fire protection systems. These special items help create the
• Automatic Unnecessary
ideal configuration for any protection usage.
Actuation of Fire Dept.
Electric &/or Dispatch
Hydraulic • Eliminate
Alarms Expelled Water
model fl-1
Fusible Links – 50 lb.
• Heat-activated releasing device designed Tech Data TFP1610
for installation in mechanically operated
systems requiring a positive acting release
mechanism • When the alloy melts, the fusible assembly
• Used extensively as releasing devices in compresses, allowing it to eject from
restaurants and industrial fire protection between the two-piece strut, strut assembly
systems, as well as in heat-activated separates, activating the intended fire
counterbalanced systems such as fire protection system or device
doors, dampers and kitchen chemical • Releasing mechanism rated for 5-lbs. to
systems 50-lbs. loads
• Consists of fusible alloy sealed in the • Listings and Approvals: UL and FM
center of a bronze tube by a stainless
steel ball
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Model MC-1
Manual Control Station
• Provides a tamper resistant means for Tech Data TFP1382
emergency release
• Interconnection with the valves may be • Listings and Approvals:
direct via hydraulic (wet) pilot line or UL, C-UL and FM
indirect via pneumatic (dry) pilot line to a
Model DP-1 Dry Pilot Actuator
• Rated for use in services up to
250 psi (17.2 bar)
Signs
Identification Signs
• Designed to provide information to the Tech Data TFP1615
end user about the sprinkler system and
its components
• Available with a variety of wording
combinations to meet the signage
requirements of NFPA 13
SF-1 s p e c i a lt y i t e m s
Sight Flow Connection
• Designed for use in fi re protection Tech Data TFP1635
systems as a means for visibly checking
that water is flowing and filling the pipe at
that point
• May be installed vertically or horizontally
• Maximum Working Pressure:
175 psi (12,1 bar)
• Listings and Approvals:
UL & FM
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
AD-1
Automatic Drain Valve
• Designed for use with Tyco Dry Pipe, Tech Data TFP1630
Deluge, and Preaction Valves
• Provided as a trim component for these • Listings and Approvals:
valves, the Model AD-1 Automatic Drain UL, C-UL, FM, NYC under MEA 172-02-E
Valve is used to automatically drain the
normally dry alarm lines
• Maximum Pressure 250 psi (17,2 bar)
AD-2
Automatic Drain Valve
• Designed to automatically drain water Tech Data TFP1632
from fire protection equipment supply
connections that are to be maintained • Listings and Approvals:
normally dry UL & FM
• Installed vertically and utilized with an
open drain
• Maximum Working Pressure:
175 psi (12,1 bar)
Hangers
s p e c i a lt y i t e m s
Pipe Hangers
• A full-line of pipe hangers for every fire Tech Data Contact Tyco for details
protection need
• Manufactured to meet the quality
standards that the industry demands
• Meet the requirements of NFPA 13
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
F e at u r e s :
F i g u r e 70 5
Flexible Coupling
• Available sizes: 11⁄4" (DN32) through Tech Data TFP1820
12" (DN300)
• Provides the needed flexibility to
accommodate differential movement • Also available with tri-seal Grade E gasket
• Capable of pressures up to 300 psig for dry pipe fire protection systems, vacuum
(2068 kPa) depending on pipe size and systems, and freezer applications
wall thickness • Listings and Approvals:
• Standard Grade A pre-lubed gasket UL, ULC, FM, VdS, & LPCB
F i g u r e 71 6
Flexible Reducing Coupling
• Available sizes: 2" x 11⁄2" (DN50 x DN40) Tech Data TFP1830
through 8" x 6" (DN200 x DN150)
• Allows easy transition between two • Faster and easier than threading,
different pipe sizes and replaces two welding or using flanges
grooved piping products
F i g u r e 70 7
Flexible Coupling
• Available sizes: 11⁄2" x 12" (DN40 x DN300) Tech Data TFP1840
• Provides a dependable method of joining
pipe and is suitable for use in a variety of • Listings and Approvals:
applications UL, ULC, FM, VdS, & LPCB
• Capable of pressures up to 500 psig
(3447 kPa) depending on pipe size and
wall thickness
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
F i g u r e 70 2
Mechanical Outlet Coupling
• The GRINNELL Figure 702 is a pipe joining Tech Data Contact Tyco for details
coupling with an integral reducing outlet,
eliminating the need for a mechanical tee
• The Figure 702 can be used for vacuum
or a reducing tee and associated couplings
service up to 10 inHg (254 mmHg) that can
• Run sizes from 1-1⁄2" to 6" (DN40 to DN150) occur when the system is drained.
• Maximum Pressure 500 psi (34,5 bar)
• The Figure 702 is available with grooved,
male threaded, or female threaded outlets.
F i g u r e 73 0
Mechanical Tees & Crosses
• Threaded or grooved outlet Tech Data TFP1860
• May be used for any tee connection where
a threaded or grooved outlet is needed
• Can be configured as a cross when
ADAC AP®
• Used to install the last sprinkler on Tech Data TFP1810
grooved branch line piping or as a
drain fitting
• End-of-the-line sprinkler fittings eliminate
the need for an end cap and female outlet
• Can be turned down for end of line drain
• Available in 1⁄2", 3⁄4" and 1" outlets
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
40 - 5 S t rap
• Sprinkler Outlet Tech Data Contact Tyco for details
• Run sizes in 1-1⁄4" to 2-1⁄2" outlets (DN32 to
DN65)
R o l l Gr o o v e r s
• Large assortment of roll groovers available Tech Data Contact Tyco for details
• Automatic and portable roll groovers for
1" through 24" pipe
grooved piping products
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
a pp l i c a t i o n s :
• Light Hazard • Connections to
& Residential Copper & Steel
Occupancies Piping
• Unfinished • Resistance
Tyco CPVC Pipe & Fittings manufactured with Basements of Sweating,
Lubrizol's BlazeMaster® compound are listed by
• Underground Condensation
Underwriters Laboratories, Inc. for use in:
Water Pressure & MIC
• Light hazard occupancies as defined in the
Standard for Installation of Fire Sprinkler Systems,
Service CPVC Pipe & Fit tings
NFPA 13
• Blazemaster Pipe and Fittings are listed and • Elbows, tees, crosses, couplings, sprinkler head
approved for use in the widest range of adapters (SHA’s), reducing tees, reducing bushings,
applications for any CPVC fire sprinkler systems CPVC to grooved couplings
Bac k - t o - Bac k F i t t i n g s
• Included in the Tyco line of Tech Data IH-1900
BLAZEMASTER® CPVC products
• Allows two sidewall sprinklers to be
piped from one fitting • Specially designed and dimensioned to
enable the sidewall sprinklers to be
• Ideal when the CPVC piping is located
recessed with 1⁄2" or 5⁄8" sheet-rock
in a 31⁄2" (2" x 4") vertical wall, eliminating
wall covering
the need for extra nipples, fittings and
sprinkler head adapters typically
associated with supplying two rooms
with the same pipe
C P V C t o C o pp e r F i t t i n g
• Available sizes: 3⁄4" through 2" Tech Data IH-1900
• Transition to BLAZEMASTER pipe from
traditional copper tube for plumbing
services
cpvc pipe & threaded fit tings
C P V C H a n g e r s & S u pp l i e s
• “No Block Hanger" is a two hole strap that Tech Data IH-1900
eliminates blocking to the beam when
hanging CPVC pipe
• One-Step CPVC Cement specifically
• Positions the face of the pipe 11⁄2" off the formulated for use with BlazeMaster pipe
face of the joist and fittings
• Headset hanger is designed to hang CPVC
pipe and for the proper placement of the
sprinkler before the ceiling is installed
• Provides vertical restraint, eliminating
need for additional hangers
• BLAZEMASTER Caulk and Walk® Firestop
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
F e at u r e s :
• Easier to • Built-in
Produc ts
Install, Set & High & Low
Maintain than Pressure Alarm
Mechanical Supervision
Accelerators • Battery Back- Devices
Electrical Devices (alarm and supervisory) allow • Operation of up in the Event Piping
sprinkler and other fire protection systems to be interfaced the Dry Pipe of Primary
with hydraulic or electronic alarm systems so that upon Valve within Power Failure
activation of the system, an electrical or mechanical signal
Four Seconds
trical
V S R W at e rf l o w A l arm Sw i t ch f o r s ma l l p i p e
Flow & Pressure Switch
• Available pipe sizes: Tech Data Contact Tyco for details
1" (DN25), 11⁄4" (DN32), 11⁄2" (DN40) or
2" (DN50)
• Vane type waterflow switch for use on
wet sprinkler systems
• May also be used as a sectional water flow
detector on large systems
• Installs directly into a threaded tee
M o d e l P S 1 0/ P S 4 0 P r e s s u r e a l arm Sw i t ch
Flow & Pressure Switch
• Designed to detect a pressure increase or Tech Data Contact Tyco for details
decrease in fire sprinkler systems
• PS40 switches are primarily used to
monitor low air pressure conditions in
dry systems
• PS10 switch is appropriate for water flow
detection
electrical devices
Ba l l V a lv e w i t h S u p e rv i s o r y Sw i t ch
Ball Valve with Tamper & Alarm Switch
• Utilizes a 1⁄2" ball valve in combination Tech Data Contact Tyco for details
with a switch assembly
• Switch assembly enclosed in a tamper
resistant NEMA 4 (water resistant)
enclosure
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
S o l e n o i d V a lv e
For Releasing Service – 1⁄2" (DN15)
• Used in conjunction with an electric Tech Data TFP2180
releasing panel that is listed or approved
(as appropriate) for fire protection
releasing service, and where the releasing
panel is operated by listed or approved
(as appropriate) electric fire detectors
• Available in a variety of voltages for both
normal and hazardous locations
OSY - SU
Tamper & Alarm Switch
• Used to monitor the open position of an Tech Data Contact Tyco for details
OS&Y (outside screw and yoke) type
gate valve
• Mounts conveniently to most OS&Y
valves ranging in size from 2" (DN50)
to 12" (DN300)
• Can be used on some valves as small as 1⁄2"
• Circulates single sprinkler flow and allows
testing of flow switch without external
discharge of water - replaces traditional
Inspector's test procedure
4410-RC
electrical devices
Releasing Panel
• Provides the interface between detection Tech Data Contact Tyco for details
system, deluge or single or double
interlocked preaction valve, and signaling • Can be used in single zone, cross zone,
circuit and devices in electrically actuated sequential or cross/sequential electric
fire protection systems deduction systems
• Separate supervisory zone provided for • Has programming capability
electronic supervision of valve position,
• Listings and Approvals: UL and FM
low pressure, and other critical fire
protection functions
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Ba s e M o u n t e d A i r C o mpr e s s o r
For Dry Pipe Sprinkler Systems
• Designed for high volume (cubic feet of Tech Data Contact Tyco for details
air per minute) at the moderate pressures
required for the system
• Sized properly, these will fill the system to
40 PSIG of air pressure in approximately
30 minutes as required in NFPA 13
R i s e r M o u n t e d A i r C o mpr e s s o r
Fully Automatic
• Fully automatic and are designed for easy Tech Data Contact Tyco for details
installation
• Special mounting kits with U-bolts are
available to facilitate riser mounting
• Sized properly, these compressors will fill
a system to 40 PSIG within 30 minutes as
required in NFPA 13
electrical devices
Model G16AC812
Automatic Supervisory Air Supply
• Supplies and maintains air in single Tech Data TFP1620
interlock preaction fire protection systems
having a nominal supervisory air pressure
of 10 psi (0.7 bar)
• Can be mounted on the floor, on a wall, or
to the system riser using optional brackets
• Listings and Approvals: UL
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
General’s DAP Series Dry Air Pac™ is an FM Approved, twin tower regenerative
dryer / compressor package. This turnkey system is designed to provide the
sprinkler system with moisture free air to a -40°F Dew Point. The air compressor is
designed to fill the sprinkler system in accordance with NFPA 13 standards, as well
as provide the higher pressure needed to allow the twin tower regenerative dryer
to function properly.
Prior to entering the regenerative air dryer, an air cooled aftercooler cools the
compressor’s hot discharge air to a maximum 100°F. A coalescing prefilter with
differential pressure gauge removes oil vapor and other contaminants that can
destroy the desiccant in the dryer towers. A combination particulate filter and
regulator prevents downstream migration of desiccant dust while regulating air
pressure to the sprinkler system.
• Combination after filter and regulator • A coalescing filter, with integral differential pressure gauge,
electrical devices
removes oil and water droplets prior to entry to into the
• A separate port is provided for attachment of a
desiccant dryer
dewpoint-monitoring device
• The single stage compressor allows for maximum efficiency.
• Oversized mufflers
Standard equipment includes intercooler, oil fill/breather, oil
• Fully integrated control panel sight glass and easily removable drain plug
• Compact air cooled after cooler • UL, C-UL Listed, FM Approved
• Prefilter with differential pressure
• Vibration pads
• The Dry Air Pac™ comes fully charged with desiccant so that Tech Data Contact Tyco for details
no on-site desiccant installation is required at startup
• Separate desiccant fill and drain ports are provided to allow
re-charging of the dryer tanks without disassembly of the
dryer component piping
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
J-Box or
ELR-Box
Chemical and UV Resistant
Potter® Electronic Polymer Outer Covering
Series PFC-4410-RC DV-5 Cable Strain Relief Connectors
Releasing Panel Deluge/Preaction Valve
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
a pp l i c a t i o n s :
• Class B • Refineries
Hydrocarbon • Marine Vessels
Fuel Fires Such
as Crude Oils, • Warehouses
Gasoline, Diesel • Special Class A
Fuels & Aviation Foam
Foam-Water Systems most commonly use Fuels Concentrates
the balanced pressure proportioning method for
• Class B Polar for Use with
flammable liquid fire protection applications. They
are designed to accurately control the flow of a Solvent Fuel fires Municipal
such as Methyl and Forest
Foam Systems
Legend:
1 Deluge Valve (DV-5) 9 Releasing Panel
2 Isolation Valve 10 Spray Nozzle
3 Diaphragm Supply Valve 11 Smoke/Heat Detector
4 Manual Control Station 12 Solenoid Valve
5 Automatic Shut-off Valve 13 Foam Proportioner
6 Automatic Drain Valve 14 Foam Bladder Tank
7 Pressure Switch 15 Foam Concentrate
8 Water Motor Gong 16 Hydraulic Ball Valve
b l a d d e r ta n K s
Foam Bladder Tanks
• Elastomeric bladder stores foam liquid • Foam concentrate capacities from
concentrate discharged by incoming 50 to 1500 gal (190 to 5678 L)
water applying pressure to the bladder • Red standard system paint or coated with
• Both vertical and horizontal models are an epoxy “CR” red finish for use in marine
available or corrosive environments
• Internal tank perforated center tube • Standard or pre-piped tanks with
provides improved agent discharge proportioner for ease of installation
300 gal (1136 L) Horizontal
Tank Shown
pr o p o r t i o n e r
2" and 21⁄2" In-Line Proportioner
• Each proportioner consists of a body, inlet • The metering orifice is sized according to
nozzle, and metering orifice, all of which the type and percentage of concentrate
are corrosion-resistant brass used and is also secured with a stainless
steel retaining ring)
• The proportioner body is designed with a
f oa m s ys t e m s
WATER
INLET METERING ORIFICE
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
F o am A g e n t s
ANSULITE® 1% AFFF Concentrate
• For use on Class B hydrocarbon fuel fires such as crude oils, gasoline, diesel fuels and aviation fuels. Aspirated
or nonaspirated discharge devices. 1% solution in fresh, salt or hard water. 1% premix in fresh or potable
water. UL Listed.
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
H i g h - E x pa n s i o n f o am P r o d u c t s
JET-X® High-Expansion Foam Generators
• Water-powered. Designed to deliver • No electrical power is required
JET-X® high expansion foam with a • The generators come in various sizes and
maximum output capacity of 24,000 cfm are used for both portable and fixed-system
(680 cu. m/min.) The generators are of applications
steel construction with a water powered
motor and stainless steel foam screen f oa m s ys t e m s
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
D3 B-1
Protectospray™ Nozzle 1⁄
2" Foam-Water Sprinkler
Tech Data TFP802 Tech Data TFP840
additional info Page 48 additional info Page 49
EA-1 TY - B
Automatic Protectospray™ Upright & Pendent
Nozzle Tech Data TFP151
TY - F R B ELO - 231 B
Upright & Pendent Pendent & Upright
Tech Data TFP171 Tech Data TFP342
additional info Page 9 additional info Page 23
TY - F R L
f oa m s ys t e m s
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
a pp l i c a t i o n s :
• Cable Trays • Historic Sites &
• Clean Rooms Museums
DV-5 Deluge
Valve
Variable Pressure
AquaMist Fire Pump
HEAT
• Increase in surface area allows for
VAPOR source
larger cooling effect for a given flow • Higher heat level causes a faster
vaporization
3 4
• Fire extinguishment is improved with • Small water droplets tend to remain
LARGER DROPS BLOCKS RADIANT
PENETRATE TO
direct contact of water droplets HEAT AND suspended
COOLS GASSES
BURNING SURFACE • This type of extinguishment is • The expanding mist will expand and
normally associated with standard cool the gases and other fuels in the
sprinklers area
• Important part of operation if • Blocks the transfer of radiant heat
ventilation is a factor and Class A to the adjacent combustibles and
combustibles are present pre-wets them
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
A M 4 A Q U A M IST ®
Open Type Mist Nozzle
• Open spray nozzles K Factor K=0.24 (3,5)
• Listed and Approved for the protection of Thread Size 2" NPT
1⁄
A M 2 4 A Q U A M IST ®
Automatic Type Mist Nozzle
• Listed and Approved for marine type K Factor 0.33 Gpm/psi 0.5,
aq ua m i s t® s ys t e m s
approved by Lloyds, USCG, DNV, American (4,71 Lpm/bar 1/2)
Bureau of Shipping, MCA, Germanischer Thread Size 2" NPT
1⁄
Lloyd, Bureau Veritas
Approvals UL
• Intended applications – IMO mandated
Finish Stainless Steel
local application system for protection of
class a machinery spaces tech data TD1172
Always refer to the product’s Technical Data Sheet for a complete description of all Listing and Approval criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty.
SprinkCALC ™
Advanced Hydraulic Calculations
Welcome to the newest and most advanced hydraulic
calculation program available today... SprinkCALC
SprinkFDT ™
The first program to be listed by Underwriters Laboratories
and Factory Mutual specification tested for the calculation
of dry type systems per NFPA® requirements
SprinkSLIC ™
Complete Fire Sprinkler Stock Listing
The name of the game is "PIPE ON THE JOB" and
Stocklisting is the bridge between design and installation
SprinkCODE ™
Interactive NFPA 13® Code Selector
Whether it's an estimate or the final design, this Code
Expert is an essential member of your staff
www.sprinkcad.com
NORTH AMERICAN & EUROPE & MIDDLE EAST AUSTRALIA
WORLDWIDE HEADQUARTERS Regional Headquarters Regional Headquarters
Tyco Fire Protection Products Kopersteden 1, NL-7547 TJ Level 3, 95 Coventry Street,
1400 Pennbrook Parkway P.O. Box 198, Southbank, Vic 3006
Lansdale, PA 19446 7500 AD Enschede, Tel: +61 3 9313 9700 (International)
Tel: 215-362-0700, 800-523-6512 The Netherlands Tel: 1300 725 688 (In Australia)
Fax: 215-362-5385 Tel: +31 (0)53-428-4444 Fax: 1300 720 733 (In Australia)
Fax: +31 (0)53-428-3377
LATIN AMERICA
Regional Headquarters ASIA
South America, Central America & Regional Headquarters
Caribbean 2 Serangoon North Avenue 5
1802 S.W. 2nd Street #07-01
Pompano Beach, FL 33069 Singapore 554911
Tel: 954-781-0866 Tel: +65 6577-4360
Fax: 954-781-9330 Fax: +65 6481-8791
www.tyco-fire.com
www.tyco-rapidresponse.com
www.grinnell.com
Europe & Middle East: www.tfppemea.com
Asia: www.tyco-fire.com.cn