You are on page 1of 194

INSTALLATION MANUAL

DIGITAL MINILAB
FRONTIER
FE SYSTEM
BASIC SOFTWARE

FE System Ver.2.0 or later First Edition


PP3-A1311E
INTRODUCTION

INTRODUCTION

This installation manual explains the procedures for installing and setting up the FE Software for the
Fujifilm Digital Minilab FRONTIER Series as well as precautions for its use.

This manual should be kept in a fixed place near the machine so that it can be referred to at any
time a point needs to be clarified.

The following symbols indicating the model and software names are used in this manual.

Symbol Software/Model

S1 SP-3000 Basic Software


S2 DICII Basic Software
S3 Variety Print Software
S4 Tone Selection Software
S5 Professional Color Correction Software
S7 Multi-DICII Connection Software
S8 Frontier Manager II Software
S9 Frontier Manager Printer Controller II Software
S11 Printer Driver Software
S12 Full Automatic Red-eye Correction Software
S13 DI Simple Print Software
SP Scanner/Image Processor
LP Laser Printer/Paper Processor
DICII Digital Imaging Controller II
E-DICII Extra Digital Imaging Controller II
FMPCII Frontier Manager Printer Controller II
DIC Imaging Controller

The enclosed "END-USER LICENSE AGREEMENT" should be read carefully before you use this
software.

Specifications are subject to change without notification.

ZipTM is a trademark of the Iomega Corporation.


SmartMediaTM is a trademark of the Toshiba Corporation.
CompactFlashTM is a trademark of the SanDisk Corporation.
MicrodriveTM is a trademark of the IBM Corporation.
Memory StickTM and Memory Stick DuoTM are trademarks of the Sony Corporation.
SD Memory CardTM is a trademark of the Toshiba Corporation, the Matsushita Electric Industrial Co., Ltd. and
the SanDisk Corporation.
miniSD Memory CardTM is a trademark of the SD Card Association.
Microsoft®, Windows® and Windows® 2000 are registered trademarks of the Microsoft.
All other brand names or trademarks are the property of their respective owners.
CONTENTS

1 Outlines.....................................................................................................................................
8
1.1 Installation Outlines ............................................................................................................ 8
1.2 Installation Workflow........................................................................................................... 9
1.2.1 Installation Preparation ............................................................................................. 9
1.2.2 Before-installation Work ............................................................................................ 9
1.2.3 Installation of Each Device........................................................................................ 10
1.2.4 After-installation Work ............................................................................................... 10
1.3 Installation Methods............................................................................................................ 11
1.3.1 Set-up Conditions for Installation .............................................................................. 11
1.3.1.1 Scanner (SP) Conditions ........................................................................ 11
1.3.1.2 DIC Conditions........................................................................................ 11
1.3.1.3 E-DIC (Second DIC) Conditions ............................................................. 12
1.3.1.4 FMPCII Conditions ................................................................................. 12
1.3.2 Installation Patterns................................................................................................... 13
FE Installation Procedure [New Installation] Pattern 1 .......................................... 14
FE Installation Procedure [Upgrading] Pattern 2 ................................................... 16
FE Installation Procedure [Installing FE Software
in Earlier-type System] Pattern 3 ........................................................... 18

2 Installation Preparations for S1/S2/S7/S9................................................................... 20


2.1 Print Size Setting Preparations........................................................................................... 20
2.1.1 Copying Print Size Copy Tool (PrintsizeSnc.exe) to FD ........................................... 20
2.1.2 Copying Print Sizes from FRONTIER to FD ............................................................. 21
2.2 Billing Data Preparation...................................................................................................... 23
2.2.1 Copying the Default Billing Data ............................................................................... 23
2.2.2 Registering the Price List in the Server Database .................................................... 24

3 DICII (S2) Installation .......................................................................................................... 25


3.1 DICII (S2) Installation Outlines........................................................................................... 25
3.1.1 Installation Procedure ............................................................................................... 25
3.1.2 Preliminary Work for S2-use Hardware..................................................................... 26
3.2 BIOS Setting and User Registration ................................................................................... 28
3.2.1 Hyper-threading Setup .............................................................................................. 28
3.2.2 User Registration ...................................................................................................... 28
3.3 Windows Settings ............................................................................................................... 30
3.3.1 Settings Completed with Batch File .......................................................................... 30
3.3.2 Disabling Windows XP Style (only in Windows XP).................................................. 30
3.3.3 [Date and Time Settings] Regional and Language Settings ..................................... 31
3.3.4 System Error Setting ................................................................................................. 31
3.3.5 Disabling User Assistant Function ............................................................................ 32
3.3.6 Hide Setting of Screen Keyboard Dialog Box ........................................................... 32
3.3.7 Disabling Error Reporting (only in Windows XP)....................................................... 32
3.3.8 Auto-hide Setting for Task Bar .................................................................................. 33
3.3.9 “Visual Notification” to ON in Dr. Watson Dialog Box................................................ 34
3.3.10 Disabling Windows Firewall (only in Windows XP) ................................................... 34
3.3.11 Disabling Security Center (only in Windows XP) ...................................................... 35
3.3.12 Time Zone Setting (for each country)........................................................................ 35

3
3.3.13 LIOS User Registration ............................................................................................. 36
3.3.14 Setting IE Page for Receipt Printer ........................................................................... 36
3.4 Installing Windows Basic Software..................................................................................... 37
3.4.1 Installing MSDE2000 database engine SP3a ........................................................... 38
3.4.2 Installing IIS (Internet Information Services) ............................................................. 38
3.4.3 Installing .Net Framework V1.1 ................................................................................. 40
3.5 S2 Software Installation...................................................................................................... 41
3.6 Optional Software Installation............................................................................................. 44
3.6.1 Variety Print Software (S3) Installation ..................................................................... 44
3.6.2 Tone Selection Software (S4) Installation ................................................................. 46
3.6.3 Professional Color Correction Software (S5) Installation .......................................... 47
3.6.4 Frontier Manager II Software (S8) Installation .......................................................... 48
3.6.5 Full Automatic Red-eye Correction Software (S12) Installation ................................ 50
3.7 After-installation Work ........................................................................................................ 52
3.7.1 Driver Software Installation ....................................................................................... 52
3.7.2 Receipt Printer/Barcode Reader Setup..................................................................... 52
3.7.3 Installing the Speaker used for Indicating Order Completion.................................... 52
3.7.4 Custom Data Copy Tool............................................................................................ 52
3.7.5 Media Output Setting ................................................................................................ 52
3.7.6 LIOS Order Processing Settings ............................................................................... 53
3.7.7 PLMaker Setting........................................................................................................ 54
3.7.8 Media Index Setting .................................................................................................. 54
3.7.9 Holiday/Opening Time Setup (0927)......................................................................... 56
3.7.10 Media Input Environment Setup (0136) .................................................................... 59
3.7.11 Writing Service Settings (0137)................................................................................. 59
3.7.12 Photo Copy Configuration (0138).............................................................................. 60
3.7.13 Index Conditions (0227) ............................................................................................ 61
3.7.14 Print Condition Setup ................................................................................................ 61
3.7.15 Equipment Name Set (0124)..................................................................................... 62
3.7.16 Red Eye Correction Setup (0201) (only in case of the Earlier-type System) ............ 62
3.7.17 Billing Environment Setup (0925).............................................................................. 63
3.7.18 Shop Logo Regist/Delete (1020)............................................................................... 63
3.7.19 Remote Desktop Settings (only in use of FMPC in the Earlier-type System) ........... 64
3.7.20 Setting the HELP....................................................................................................... 66

4 SP (S1) Installation ............................................................................................................... 70


4.1 SP (S1) Installation Outlines............................................................................................... 70
4.1.1 Installation Procedure ............................................................................................... 70
4.1.2 Preliminary Work for S1-use Hardware (SP-3000) ................................................... 70
4.2 Windows Settings ............................................................................................................... 71
4.2.1 [Date and Time Settings] Regional and Language Settings ..................................... 71
4.2.2 Time Zone Setting (for each country)........................................................................ 71
4.2.3 “Rollup 35” Installation Procedure............................................................................. 71
4.3 S1 Software Installation (Upgrading from A1 to S1)........................................................... 73
4.4 Optional Software Installation............................................................................................. 75
4.4.1 Variety Print Software (S3) Installation ..................................................................... 75
4.4.2 Tone Selection Software (S4) Installation ................................................................. 76

4
4.4.3 Professional Color Correction Software (S5) Installation .......................................... 77
4.4.4 Frontier Manager II Software (S8) Installation .......................................................... 78
4.4.5 Full Automatic Red-eye Correction Software (S12) Installation ................................ 79
4.5 After-installation Work ........................................................................................................ 81
4.5.1 Remote Desktop Settings (Only when using the FMPCII)........................................ 81
4.5.2 Copying Print Sizes from FRONTIER to FD ............................................................. 84
4.5.3 Media Output Setting ................................................................................................ 86
4.5.4 Scanner Parameter Check/Update (0350)................................................................ 87
4.5.5 Scanner and Carrier Adjustment/Maintenance menus ............................................. 88
4.5.6 Equipment Name Set (0124)..................................................................................... 88
4.5.7 Installation Information Setup (0140) ........................................................................ 88
4.5.8 Shop Logo Regist/Delete (1020)............................................................................... 89
4.5.9 Setting the HELP....................................................................................................... 89

5 E-DICII (S7) Installation ...................................................................................................... 90


5.1 E-DICII (S7) Installation Outlines ....................................................................................... 90
5.1.1 Installation Procedure ............................................................................................... 90
5.1.2 Preliminary Work for S7-use Hardware..................................................................... 91
5.2 BIOS Setting and User Registration ................................................................................... 92
5.2.1 Hyper-threading Setup .............................................................................................. 92
5.2.2 User Registration ...................................................................................................... 92
5.3 Windows Settings ............................................................................................................... 94
5.3.1 Settings Completed with Batch File .......................................................................... 94
5.3.2 Disabling Windows XP Style (only in Windows XP).................................................. 94
5.3.3 [Date and Time Settings] Regional and Language Settings ..................................... 95
5.3.4 System Error Setting ................................................................................................. 95
5.3.5 Disabling User Assistant Function ............................................................................ 96
5.3.6 Hide Setting of Screen Keyboard Dialog Box ........................................................... 96
5.3.7 Disabling Error Reporting (only in Windows XP)....................................................... 96
5.3.8 Auto-hide Setting for Task Bar .................................................................................. 97
5.3.9 “Visual Notification” to ON in Dr. Watson Dialog Box................................................ 98
5.3.10 Disabling Windows Firewall (only in Windows XP) ................................................... 98
5.3.11 Disabling Security Center (only in Windows XP) ...................................................... 99
5.3.12 Time Zone Setting (for each country)........................................................................ 99
5.3.13 LIOS User Registration ............................................................................................. 100
5.3.14 Setting IE Page for Receipt Printer ........................................................................... 100
5.4 S7 Software Installation...................................................................................................... 101
5.5 Optional Software Installation............................................................................................. 103
5.5.1 Variety Print Software (S3) Installation ..................................................................... 103
5.5.2 Tone Selection Software (S4) Installation ................................................................. 105
5.5.3 Professional Color Correction Software (S5) Installation .......................................... 106
5.5.4 Frontier Manager II Software (S8) Installation .......................................................... 107
5.5.5 Full Automatic Red-eye Correction Software (S12) Installation ................................ 108
5.6 After-installation Work ........................................................................................................ 110
5.6.1 Driver Software Installation ....................................................................................... 110
5.6.2 Receipt Printer/Barcode Reader Setup..................................................................... 110
5.6.3 Installing the Speaker used for Indicating Order Completion.................................... 110

5
5.6.4 Custom Data Copy Tool............................................................................................ 110
5.6.5 Media Output Setting ................................................................................................ 110
5.6.6 PLMaker Setting........................................................................................................ 111
5.6.7 Media Index Setting .................................................................................................. 111
5.6.8 Media Input Environment Setup (0136) .................................................................... 112
5.6.9 Writing Service Settings (0137)................................................................................. 113
5.6.10 Photo Copy Configuration (0138).............................................................................. 113
5.6.11 Index Conditions (0227) ............................................................................................ 114
5.6.12 Print Condition Setup ................................................................................................ 115
5.6.13 Equipment Name Set (0124)..................................................................................... 115
5.6.14 Shop Logo Regist/Delete (1020)............................................................................... 115
5.6.15 Remote Desktop Settings (only in use of FMPC in the Earlier-type System) ........... 116
5.6.16 Setting the HELP....................................................................................................... 118

6 FMPCII (S9) Installation ..................................................................................................... 119


6.1 FMPCII (S9) Installation Outlines....................................................................................... 119
6.1.1 Installation Procedure ............................................................................................... 119
6.1.2 Preliminary Work for S9-use Hardware..................................................................... 120
6.2 Setting IEEE1394 Driver..................................................................................................... 121
6.2.1 When Connecting FMP Controller, SP-3000, LP-5500/LP-5700/LP-5900................ 121
6.2.2 When Connecting FMP Controller, SP-3000 and LP1500/LP2000........................... 123
6.2.3 When Connecting FMP Controller to SP1500/2000 and LP1500/LP2000................ 125
6.2.4 When Connecting FMP Controller to SP1500/2000 and LP5000 Series .................. 126
6.2.5 DICII, FMPCII and LP5000 Series (no SP) Configuration........................................ 129
6.2.6 Error Message........................................................................................................... 129
6.3 Disconnecting PU800B....................................................................................................... 129
6.4 BIOS Setting and User Registration ................................................................................... 130
6.4.1 Hyper-threading Setup .............................................................................................. 130
6.4.2 User Registration on ................................................................................................. 130
6.5 Windows Settings ............................................................................................................... 133
6.5.1 Settings Completed with Batch File .......................................................................... 133
6.5.2 Disabling Windows XP Style ..................................................................................... 133
6.5.3 [Date and Time Settings] Regional and Language Settings ..................................... 134
6.5.4 System Error Setting ................................................................................................. 134
6.5.5 Disabling User Assistant Function ............................................................................ 135
6.5.6 Hide Setting of Screen Keyboard Dialog Box ........................................................... 135
6.5.7 Disabling Error Reporting.......................................................................................... 135
6.5.8 Auto-hide Setting for Task Bar .................................................................................. 136
6.5.9 “Visual Notification” to ON in Dr. Watson Dialog Box................................................ 137
6.5.10 Disabling Windows Firewall ...................................................................................... 137
6.5.11 Disabling Security Center.......................................................................................... 138
6.5.12 Inhibition of IE Dialog Display (for Web maintenance display).................................. 138
6.5.13 Time Zone Setting (for each country)........................................................................ 139
6.5.14 Remote Desktop Setting ........................................................................................... 139
6.5.15 Setting IE Page for Receipt Printer ........................................................................... 140
6.6 S9 Software Installation...................................................................................................... 141

6
6.7 Optional Software Installation............................................................................................. 144
6.7.1 Frontier Manager II Software (S8) Installation .......................................................... 144
6.7.2 Full Automatic Red-eye Correction Software (S12) Installation ................................ 145
6.8 After-installation Work ........................................................................................................ 147
6.8.1 Media Output Setting ................................................................................................ 147
6.8.2 Installation Information Setup (0140) ........................................................................ 148
6.8.3 Print Size Setup (0220) ............................................................................................. 148
6.8.4 1394 Connection Check (0145) (only in use of earlier system (FMPC))................... 149
6.8.5 Copying Print Sizes from FMPC (S9) to FD.............................................................. 149
6.8.6 Setting the HELP....................................................................................................... 150

7 S2 (Client) Installation for Earlier-type FRONTIER ................................................. 151


7.1 S2 (Client) Installation Procedure....................................................................................... 151
7.2 After-installation Work ........................................................................................................ 152
7.2.1 Installation Information Setup.................................................................................... 152

8 Connections and Start-up ................................................................................................. 153


8.1 FE System Connection Diagram ........................................................................................ 153
8.2 Starting Up the System....................................................................................................... 154

9 Application Environment Settings ................................................................................ 155


9.1 S2 Settings ......................................................................................................................... 155
9.1.1 Setup and Maintenance ............................................................................................ 155
9.1.2 Setting by Using Tools .............................................................................................. 160
9.1.3 Activating Existing System Installation (in case of Earlier-type System)................... 160
9.2 S1 Settings ......................................................................................................................... 165
9.2.1 Setting by Using Tools .............................................................................................. 165
9.2.2 Server Operation Environment Setup (0922)............................................................ 165
9.3 S7 Settings ......................................................................................................................... 167
9.3.1 Setting by Using Tools .............................................................................................. 167
9.3.2 Setup and Maintenance ............................................................................................ 167
9.4 S9 Settings ......................................................................................................................... 169
9.4.1 Setup and Maintenance ............................................................................................ 169
9.5 Setting on the Earlier-type FRONTIER............................................................................... 171
9.6 Environment Settings for S1/S2/S7/S9............................................................................... 172

10 Appendix .................................................................................................................................. 181


10.1 Data Set Tool...................................................................................................................... 181
10.1.1 Saving Data onto FD................................................................................................. 181
10.1.2 Copying Data to System ........................................................................................... 182
10.2 Custom Data Copy Tool ..................................................................................................... 184
10.2.1 Saving Data onto FD................................................................................................. 184
10.2.2 Copying Data to System ........................................................................................... 185
10.3 Restrictions......................................................................................................................... 185
10.4 Anti-virus Software Settings ............................................................................................... 186

11 Index........................................................................................................................................... 187

7
1 Outlines

1.1 Installation Outlines

FE Software Installation Outlines

Chapter 1 Outlines

Chapter 2 Installation Preparations

Chapter 3 DICII (S2) Installation

Chapter 4 SP (S1) Installation

Chapter 5 E-DICII (S7) Installation

Chapter 6 FMPCII (S9) Installation

Chapter 7 S2 (Client) Installation for Earlier-type FRONTIER

Chapter 8 Connections and Start-up

Chapter 9 Application Environment Settings

Chapter 10 Appendix

8
1.2 Installation Workflow

START

Installation Preparation: One or two weeks before Installation

Installation

Before-installation Work

Installation of Each Device

SP-3000 Conventional SP DICII E-DICII FMPCII

After-installation Work

END

1.2.1 Installation Preparation

Before installing the FE Software, the following preparations may be required.


To perform the installation efficiently, these preparations should be started one or two weeks before
installation and completed by the installation day. Care must be taken to create billing data because it may
require several days.
(1) Establishment of an installation plan
(2) Research of the current system environment (when upgrading from the current system to FE Software)
(3) Creating the shop logo and billing data (if required)

1.2.2 Before-installation Work

Installation begins with the following work, which includes:


(1) Hardware installation (if necessary)
(2) Before-installation work

9
1.2.3 Installation of Each Device

Outlines of installation work are as follows.

Installation of Each Device

Before-installation Work

Installation of Basic Software

Installation of Optional Applications

After-installation Work

(1) Before-installation Work


The data used in the current system is moved to the FE Software by using the tools such as print size
setting tool, etc. Deletion of the current software can also be executed.
(2) Installation of Basic Software
Install the basic software in each device.
Basic software means the S1 (FRONTIER (SP-3000) Basic Software) for SP, S2 (DICII Basic Software) for
the Imaging Controller, S7 (E-DIC Basic Software) for the second Imaging Controller (E-DIC) and S9
(FMPCII Software) for Frontier Manager Printer Controller (FMPC).
(3) Installation of Optional Application Software
Install the optional application software for the FE.
(4) After-installation Work
Perform the installation of current data and setting of each application.

1.2.4 After-installation Work

After the installation of each device is completed, connect each one and perform the settings for the entire
system. Then, perform the operational checks. If all operational checks are OK, installation work is completed.

10
1.3 Installation Methods

The installation workflow described in Section 1.2 varies depending on the installed operating
systems. In particular, the procedure for installing each device may change significantly depending
on the condition of each device. This section explains how to decide the installation methods for
your current system.

1.3.1 Set-up Conditions for Installation


The set-up conditions for installation (condition of each device) can be classified as follows.

1.3.1.1 Scanner (SP) Conditions

[1] Newly Implemented SP-3000

[2] Upgrading A1 in SP-3000 to S1

[3] Using FE Software for Conventional SP

[1] Newly Implemented SP-3000:


The S1 (SP-3000 Basic Software) of FE Software is pre-installed in the SP-3000. So, “(1) Before-
installation Work” and “(2) Installation of Basic Software” in Section “1.2.3 Installation of Each Device” are
not required.
[2] Upgrading A1 (Ver.1.7/1.8) in SP-3000 to S1:
Installation work is executed according to the flow in “1.2.3 Installation of Each Device”. When installing
S1, follow the screen instructions (click [Yes] to proceed with the installation).
[3] Using FE Software for Conventional SPs (SP1500/2000 or SLP-800SC/1000SE):
A1 and other optional software are used without change although there are version restrictions depending
on the models. Installing of software for supporting conventional SPs is required to connect FE Software to
other devices.

1.3.1.2 DIC Conditions

[1] Newly Implemented DIC

[2] Upgrading C4/C5 to S2

11
[1] Newly Implemented DIC:
If the BIOS, OS and other settings for the DIC are already completed at time of shipment, “Before-
installation Work” in “1.2.3 Installation of Each Device” may not be required. For other PCs, make sure to
perform “1.2.3”. Installation of S2 (DICII Basic Software) and subsequent procedures are required.
[2] Upgrading C4/C5 in DIC Hardware to S2:
To upgrade C4/C5 in the DIC hardware to S2, the DIC hardware settings need to be initialized by using the
Recovery CD, etc. Start the installation work beginning with the OS installation in the DIC hardware. In
addition, appropriate settings such as OS settings are required before installing S2.

In both cases, the DIC hardware settings need to be in the initial state (clean installation is required) for
installing S2. Also, perform the procedures after “Before-installation Work” in both cases.

1.3.1.3 E-DIC (Second DIC) Conditions

E-DIC is used with New Hardware.

E-DIC is used with Current DIC Hardware.

No E-DIC in System

The installation procedures for E-DIC (Second DIC) are almost the same as those for DIC described in
“1.3.1.2 DIC Conditions”. Perform a clean installation of S7 (E-DIC Connection Software).

1.3.1.4 FMPCII Conditions

FMPCII is using New Hardware.

FMPCII is using Current FMPC Hardware.

FMPCII is not used

Perform a clean installation of S9 (FMPCII Software). The installation procedures are almost the same as
those for DICII/E-DICII. When using the current FMPC (FMPCI) hardware, the hardware setting must be set
to the initial state by using the Recovery CD, etc.

12
1.3.2 Installation Patterns

As described in Section “1.3.1 Set-up Conditions for Installation”, the procedures for installing DIC/E-DIC/
FMPC are almost the same. But the work before installation varies depending on the conditions. The following
three types of installation patterns are used.

(1) Pattern 1: [New Installation]


FRONTIER is installed for the first time.

(2) Pattern 2: [Upgrading Current SP-3000]


The current software for FRONTIER 355/375/550/570/590 is upgraded to FE Software.

(3) Pattern 3: [Installing FE Software in Conventional Models]


The C4/C5 software used in the FRONTIER 330/340/350/370 system is upgraded to FE Software.

13
FE Installation Procedure [New Installation] Pattern 1

Installation Conditions
- Device Configuration before Installing FE Software:
None (New installation)
- Device Configuration after Installing FE Software:
DIC II (S2) - DIC II (S7) - SP-3000 (S1) - FMPC II (S9) -
LP5700
- Optional Software to be Installed:
S3 (S/T), S4, S5 (Pro), S8 and S12
- Device Assignment:
OET orders: CD-R writing is executed by S2.
LIOS orders: Viewing and ordering is executed by S7.
CD-R writing is executed by S2.
- Client of Remote Desktop Connection: S1
- Receipt Printer is connected to DIC II (S2).
(Billing terminal is S2.)

SP-3000 (S1) Earlier-type SPs


Option: S3, S4 (or S5), S8, S12

Preliminary Work for each Device

Conditions of DICII (S2)


Recovery CD

S1 Installation
(S1 is pre-installed on SP-3000)

Optional Software Installation (See 4.4 on page 75)


Install S3 (Standard), S4 (or S5), S8 and S12.
* For S8, select “S8 Software”.
* Each software can be installed consecutively without
restarting the system.

After-installation Work (See 4.5 on page 81)


Remote Desktop Settings

Settings by Using Tools


- Only when using S7, perform settings for PC to which
the CD-R writer is connected by using Device
Assignment Tool (OET).
* In the Installation Information Setup menu, set “No
Output Device”.

Maintenance Menu Settings


- Perform Scanner Parameter Check/Update (Menu
0350).
- Perform maintenance work for the scanner/carrier.
(Equivalent to the current system)
- Equipment Name Set (Menu 0124)
- Installation Information Setup (Menu 0140)
- Shop Logo Regist/Delete (Menu 1020)

Application Environment Settings (See 9.2 on page 165)


Maintenance Menu Settings
- Perform Server Operation Environment Setup (Menu
0922).
Settings by Using Tools
- Copy the print size settings (from FD to S1) by using
Print Size Copy Tool.
- Edit user button settings by using Custom Button
Setting Tools.

14
START : Maintenance Work Executed during Installation
: Maintenance Work to be Executed by Service Start Date

Before-installation Work (One week before installation - the day before installation)
- Set PL-Maker price information using a tool delivered in advance
- Edit the StyleSheet file for the receipt printer

Preliminary Work for Entire System (The day of Installation)


1. Disconnect each device from the LAN connection. Turn OFF the HUB or disconnect
the LAN cables from the HUB.
[CD to be Prepared] S1,S2, S3(S/T), S4, S5, S8, S7, S9, S12,
WinXP CD-ROM (attached to FMPCII)

Subsequent procedures can be executed in parallel.

DICII (S2) E-DICII (S7) FMPCII (S9)


Option: S2, S3, S4 (or S5), S8, S12 Option: S3, S4 (or S5), S7, S8, S12 Option: S8, S12

[Tasks done by Recovery CD] [Tasks done by Recovery CD] [Tasks done by Recovery CD]
Preliminary Work for each Device Preliminary Work for each Device Preliminary Work for each Device
* Procurement of PC is required for each country. * Procurement of PC is required for each country. * Because the monitor is not attached to FMPC, use the
Local procurement of a PC is required (in) each country. Local procurement of a PC is required (in) each country. monitor of another PC.
PC Preparations PC Preparations PC Preparations
- Set BIOS. - Set BIOS. - Install one IEEE1394 board.
(Set Hyper-threading for each OS type.) (Set Hyper-threading for each OS type.) - Set BIOS.
- Install OS (WinXP/2000) and set partitions. - Install OS (WinXP/2000) and set partitions. (Set Hyper-threading for each OS type.)
- Perform hard disk settings (format and drive names). - Perform hard disk settings (format and drive names). - Install OS (WinXP) and set partitions.
- Create FRONTIER user name. - Create FRONTIER user name. - Perform hard disk settings (format and drive names).
- Perform OS (XP or 2000) settings. - Perform Windows settings. - Create FRONTIER user name.
(See “Windows Setting” on “3.1.2 Preliminary Work for (See “Windows Setting” on “5.1.2 Preliminary Work - Perform Windows settings.
S2-use Hardware”.) for S7-use Hardware”.) (See “Windows Setting” on “6.1.2 Preliminary Work
- Set the computer name. - Set the computer name. for S9-use Hardware”.)
Network Environment Settings Network Environment Settings - Set the computer name.
- Set the IP address and workgroup. - Set the IP address and workgroup and disable Network Environment Settings
Install Windows basic software. Firewall. - Set the IP address and workgroup and disable
- Install MSDE2000. * Installation of Windows basic software is not Firewall.
- Install IIS. necessary. 1394 Driver Settings
- Install .Net Framework. - Preinstall 1394 Driver using 1394 Driver Disk.
- Install 1394 driver for connecting the printer/
processor.
* Enable 1394 LAN connection.
* Connect SP-3000 via Net connection.

S2 Installation (See 3.5 on page 41) S7 Installation (See 5.4 on page 101) S9 Installation (See 6.6 on page 141)
Installation of new S2. S2 is started up automatically. Install new S7. Reinstall S9 using the backup FD.

Optional Software Installation (See 3.6 on page 44) Optional Software Installation (See 5.5 on page 103) Optional Software Installation (See 6.7 on page 144)
Installation of S3 (S/T), S4 (or S5), S8 and S12. Install S3 (S/T), S4 (or S5), S8 and S12. Install S8 and S12.
* For S8, select “S8&Billing&PL-Maker”. * For S8, select “S8&Billing&PL-Maker”. * For S8, select “S8&Billing&PL-Maker”.
* Each software package can be installed consecutively * Each software package can be installed consecutively * Each software package can be installed consecutively
without restarting the system. without restarting the system. without restarting the system.

After-installation Work (See 3.7 on page 52) After-installation Work (See 5.6 on page 110) After-installation Work (See 6.8 on page 147)
Receipt Printer Installation Settings by Using Tools Maintenance Menu Settings
- Install EPSON driver attached to S8 CD-ROM. - Only when using S7, perform settings for PC to which - Set installation information (Menu 0140) (Delivery/
- Perform settings for the driver, bar-code, IE and StyleSheet. the CD-R writer is connected by using Device Startup Date).
* Batch file for setting IE is supplied. Assignment Tool (OET). - Register print sizes (Menu 0220).
Install a speaker for notification of sorting of S8. (Fixed to S2) Maintenance Menu Settings Settings by Using Tools
Settings by Using Tools - Equipment Name Set (0124) - Copy print size settings from S9 to FD by using Print
- Only when using S7, perform settings for PC to which the - Set media input environment (Menu 0136). Size Copy Tool.
CD-R writer is connected by using Device Assignment - Set index conditions (Menu 0227)(Shop Logo). - Only when using S7, perform settings for PC to which
Tool (OET and LIOS). - Shop Logo Regist/Delete (Menu 1020) the CD-R writer is connected by using Device
- Set PLMaker product information (by using tools). - Perform print condition setup. (Equivalent to the Assignment Tool (OET).
- Set Media Index (by using tools) current system) * When all settings are completed, remove the monitor.
Maintenance Menu Settings
- Equipment Name Set (Menu 0124)
- Set billing environment (Menu 0925).
- Set holiday/opening time (Menu 0927).
- Set media input environment (Menu 0136).
- Set CD-R writing output information (Menu 0137).
- Set photo copy environment (Menu 0138).
- Set index conditions (Menu 0227).
- Shop Logo Regist/Delete (Menu 1020)
- Perform print condition setup. (Equivalent to the current
system)

Up to here, operations can be performed in parallel.


Perform subsequent operations by connecting all devices (Net).
Start-up Order: [1][2] DICII (S2), LP, [3][4] FMPCII, DICII (S7), [5] SP-3000

Application Environment Settings (See 9.1 on page 155) Application Environment Settings (See 9.3 on page 167) Application Environment Settings (See 9.4 on page 169)
Settings by Using Tools Maintenance Menu Settings Maintenance Menu Settings
- Copy the print size settings (from FD to S2) by using Print - Set server operation environment (Menu 0922). - Set server operation environment (Menu 0922).
Size Copy Tool. Settings by Using Tools - Create backup FD for FMPC/printer processor.
- Edit user button settings by using Custom Button Setting - Copy the print size settings (from FD to S7) by using - Set timer for printer/processor (Menu 0121).
Tools. Print Size Copy Tool. - Perform maintenance work for the printer/processor.
Maintenance Menu Settings - Edit user button settings by using Custom Button (Equivalent to the current system)
- Perform settings for system operation (Menu 0921). Setting Tools.
* Click the [Initialization] button.

END

15
FE Installation Procedure [Upgrading] Pattern 2

Installation Conditions
- Device Configuration before Installing FE Software:
DIC (C4/C5 V5.0/5.5) - SP-3000 (A1V1.7) - LP1500 (V7.0)
- Device Configuration after Installing FE Software:
DICII (S2) - DICII (S7) - SP-3000 (S1) - FMPCII (S9) - LP1500 (V7.7)
- Optional Software to be Installed:
S3 (S/T), S4, S5 (Pro), S8 and S12
- Device Assignment:
OET orders: CD-R writing is executed by S2.
LIOS orders: Viewing and ordering is executed by S7. CD-R writing is
executed by S2.
- Remote Desktop Connection Client: S1
- Receipt Printer is connected to DICII (S2).
(Billing terminal is S2.)

SP-3000 (S1) Earlier-type SPs


Option: S1, S3, S4 (or S5), S8, S12

Preliminary Work for each Device


- When a print size in Group 2 has been used, the print
size needs to be registered in Group 1.
* When PU800B is used, remove it.
* Uninstallation of Bx software is not necessary.

Conditions of DICII (S2)


Recovery CD

S1 Installation (See 4.3 on page 73)


Select “SE maintenance” to update stand-alone scanner.
* When Frontier Manager is installed, an uninstaller is
automatically activated.

Optional Software Installation (See 4.4 on page 75)


Install S3 (Standard), S4 (or S5), S8 and S12.
(Installation can be executed in any order.)
* B1 template data are carried over.
* One hundred thousand items of order data of Hyper
Reorder Software are carried over.
* For S8, select “S8 Software”.
* Each software package can be installed consecutively
without restarting the system.

After-installation Work (See 4.5 on page 81)


Remote Desktop Settings

Settings by Using Tools


- Copy the print size settings (from S1 to FD) by using
Print Size Copy Tool.
- Only when using S7, perform settings for PC to which
the CD-R writer is connected by using Device
Assignment Tool (OET).

Maintenance Menu Settings


- Equipment Name Set (0124)
- Perform Scanner Parameter Check/Update (Menu 0350).
- Installation Information Setup (Menu 0140)
- Shop Logo Regist/Delete (Menu 1020)
- Perform maintenance work for the scanner/carrier.
(Equivalent to the current system)

Application Environment Settings (See 9.2 on page 165)


Maintenance Menu Settings
- Perform Server Operation Environment Setup (Menu
0922).

16
START : Maintenance Work Executed during Installation
: Maintenance Work to be Executed by Service Start Date

Before-installation Work (One week before installation - the day before installation)
- Set PL-Maker price information using a tool delivered in advance
- Edit the StyleSheet file for the receipt printer

Preliminary Work for Entire System (The day of Installation)


1. Create scanner and printer/processor backup FDs.
2. Turn OFF the rack auto cleaning function to save time.
3. On SP-3000 (A1) open the Installation Information Setup menu to select “No Output
Device”. After shutting down the system, only when installing FMPC, disconnect the
1394 cable connected to the printer/processor. Replace the ROM (V7.7) in the printer/
processor (LP1500).
4. Disconnect each device from the LAN connection. Turn OFF the HUB or disconnect
the LAN cables from the HUB.
[CD to be Prepared] S1,S2, S3 (S/T), S4, S5, S8, S7, S9, S12,
WinXP CD-ROM (attached to FMPCII)
Subsequent procedures can be executed in parallel.

DICII (S2) E-DICII (S7) FMPCII (S9)


Option: S2, S3, S4 (or S5), S8, S12 Option: S3, S4 (or S5), S7, S8, S12 Option: S8, S12

[Tasks done by Recovery CD] [Tasks done by Recovery CD] [Tasks done by Recovery CD]
Preliminary Work for each Device Preliminary Work for each Device Preliminary Work for each Device
- Copy custom data from C5 to FD by using a tool. * Procurement of PC is required for each country. * Because the monitor is not attached to FMPC, use the
- 512MB or larger amount of memory need to be installed in PC Preparations monitor of another PC.
PC. If necessary, install additional memory. - Set BIOS. PC Preparations
PC Preparations (Set Hyper-threading for each OS type.) - Install one IEEE1394 board.
- Set BIOS. - Install OS (WinXP/2000) and set partitions. - Set BIOS.
(Set Hyper-threading for each OS type.) - Perform hard disk settings (format and drive names). (Set Hyper-threading for each OS type.)
- Install OS (WinXP/2000) and set partitions. - Create FRONTIER user name. - Install OS (WinXP) and set partitions.
- Perform hard disk settings (format and drive names). - Perform Windows settings. - Perform hard disk settings (format and drive names).
- Create FRONTIER user name. (See “Windows Setting” on “5.1.2 Preliminary Work - Create FRONTIER user name.
- Perform Windows settings. for S7-use Hardware”.) - Perform Windows settings.
(See “Windows Setting” on “3.1.2 Preliminary Work for - Set the computer name. (See “Windows Setting” on “6.1.2 Preliminary Work
S2-use Hardware”.) Network Environment Settings for S9-use Hardware”.)
- Set the computer name. - Set the IP address and workgroup and disable - Set the computer name.
Network Environment Settings Firewall. Network Environment Settings
- Set the IP address and workgroup and disable Firewall. * Installation of Windows basic software is not - Set the IP address and workgroup and disable Firewall.
Install Windows basic software. necessary. 1394 Driver Settings
- Install MSDE2000. - Preinstall 1394 Driver using 1394 Driver Disk.
- Install IIS. - Install 1394 driver for connecting the printer/processor.
- Install .Net Framework. * Enable 1394 LAN connection.
* Connect SP-3000 via Net connection.

S2 Installation (See 3.5 on page 41) S7 Installation (See 5.4 on page 101) S9 Installation (See 6.6 on page 141)
Installation of new S2. S2 is started up automatically. Install new S7. Reinstall S9 using the backup FD.

Optional Software Installation (See 3.6 on page 44) Optional Software Installation (See 5.5 on page 103) Optional Software Installation (See 6.7 on page 144)
Install S3 (S/T), S4 (or S5), S8 and S12. Install S3 (S/T), S4 (or S5), S8 and S12. Install S8 and S12.
* For S8, select “S8&Billing&PL-Maker”. * For S8, select “S8&Billing&PL-Maker”. * For S8, select “S8&Billing&PL-Maker”.
* Each software package can be installed consecutively * Each software package can be installed consecutively * Each software package can be installed consecutively
without restarting the system. without restarting the system. without restarting the system.

After-installation Work (See 3.7 on page 52) After-installation Work (See 5.6 on page 110) After-installation Work (See 6.8 on page 147)
Receipt Printer Installation Settings by Using Tools Settings by Using Tools
- Install EPSON driver attached to S8 CD-ROM. - Copy custom data from FD to S7 by using a tool. - Only when using S7, perform settings for PC to which
- Perform settings for the driver, barcode, IE and StyleSheet. - Only when using S7, perform settings for PC to which the CD-R writer is connected by using Device
* Batch file for setting IE is supplied. the CD-R writer is connected by using Device Assignment Tool (OET).
Install a speaker for notification of sorting of S8. (Fixed to S2) Assignment Tool (OET). Maintenance Menu Settings
Settings by Using Tools Maintenance Menu Settings - Set installation information (Menu 0140) (Delivery/
- Custom Data Copy Tool - Equipment Name Set (0124) Startup Date).
- Only when using S7, perform settings for PC to which the CD-R writer - Set media input environment (Menu 0136). * When all settings are completed, remove the monitor.
is connected by using Device Assignment Tool (OET and LIOS). - Set index conditions (Menu 0227)(Shop Logo).
- Set PL-Maker product information (by using tools). - Shop Logo Regist/Delete (Menu 1020)
- Set Media Index (by using tools) - Perform print condition setup. (Equivalent to the
Maintenance Menu Settings current system)
- Equipment Name Set (Menu 0124)
- Set billing environment (Menu 0925).
- Set holiday/opening time (Menu 0927).
- Set media input environment (Menu 0136).
- Set CD-R writing output information (Menu 0137).
- Set photo copy environment (Menu 0138).
- Set index conditions (Menu 0227).
- Shop Logo Regist/Delete (Menu 1020)
- Perform print condition setup. (Equivalent to the current system)

Up to here, operations can be performed in parallel.


Perform subsequent operations by connecting all devices (Net).
Start-up Order: [1][2] DICII (S2), LP, [3][4] FMPCII, DICII (S7), [5] SP-3000

Application Environment Settings (See 9.1 on page 155) Application Environment Settings (See 9.3 on page 167) Application Environment Settings (See 9.4 on page 169)
Settings by Using Tools Maintenance Menu Settings Maintenance Menu Settings
- Copy the print size settings (from FD to S2) by using Print - Set server operation environment (Menu 0922). - Set server operation environment (Menu 0922).
Size Copy Tool. Settings by Using Tools - Turn ON the rack auto cleaning function.
- Edit user button settings by using Custom Button Setting - Copy the print size settings (from FD to S7) by using - Create backup FD for FMPC/printer processor.
Tools. Print Size Copy Tool. - Set timer for printer/processor (Menu 0121).
Maintenance Menu Settings - Edit user button settings by using Custom Button - Perform maintenance work for the printer/processor.
- Perform settings for system operation (Menu 0921). Setting Tools. (Equivalent to the current system)
* Click the [Initialization] button. Settings by Using Tools
- Copy the print size settings (from FD to S9) by using
Print Size Copy Tool.

END

17
FE Installation Procedure [Installing FE Software in Earlier-type System] Pattern 3

Installation Conditions
- Device Configuration before Installing FE Software:
DIC (C4/C5V5.0) - SP1500/2000 (A1 V7.7) - FMPC (D20) - LP1500/2000 (V7.7)
- Device Configuration after Installing FE Software:
DICII (S2) - SP1500/2000 (A1+S2C) - FMPCII (S9) - LP1500/2000 (V7.7)
- Optional Software to be Installed:
S3 (S/T), S4, S5 (Pro), S8 and S12
- Client of Remote Desktop Connection: S2
- Receipt Printer is connected to DICII (S2).
(Billing terminal is S2.)

SP-3000 (S1)
Option: A2, S1, S3, S5, S8, S12 SP1500/2000 (A1+S2Client)

Preliminary Work for each Device


* Uninstallation of Bx software is not required.
* When Frontier Manager is installed, an uninstaller is
automatically activated.
* When PU800B is used, disconnect it.

S2 (Client) Installation (See 7.1 on page 151)


* Enter the computer name of DICII and FMPCII.

Optional Software Installation

After-installation Work
- Installation information Setup (Menu 0140)

Application Environment Settings


Maintenance Menu Settings
- Set DI Manager administrative settings (Menu 41I)
(Set logical device name of printer for remote error
notification) (page XX)

18
START : Maintenance Work Required during Installation
: Maintenance Work to be Executed by Service Start Date

Before-installation Work (One week before installation - the day before installation)
- Set PL-Maker price information using a tool delivered in advance
- Edit the StyleSheet file for the receipt printer

Preliminary Work for Entire System (The day of Installation)


1. Create scanner and printer/processor backup FDs.
2. Turn OFF the rack auto cleaning function to save time.
3. Disconnect each device from the LAN connection. Turn OFF the HUB or disconnect
the LAN cables from the HUB.
[CD to be Prepared] S2, S3 (S/T), S4, S5, S8, S9, S12,
WinXP CD-ROM (attached to FMPC)
Subsequent procedures can be executed in parallel.

DICII (S2) DICII (S7) FMPCII (S9)


Option: S2, S3, S4 (or S5), S8, S12 Option: S3, S4 (or S5), S7, S8, S12 Option: S8, S12

[Tasks done by Recovery CD] [Tasks done by Recovery CD]


Preliminary Work for each Device Preliminary Work for each Device
- Copy custom data from C5 to FD by using a tool. • When a print size in Group 2 has been used, the print
- 512MB or larger amount of memory need to be installed in size needs to be registered in Group 1.
PC. If necessary, install additional memory. - Copy print size data from D20 to FD by using Print
PC Preparations Size Copy Tool.
- Set BIOS. PC Preparations
(Set Hyper-threading for each OS type.) - Install OS (WinXP) and set partitions.
- Install OS (WinXP/2000) and set partitions. - Perform hard disk settings (format and drive names).
- Perform hard disk settings (format and drive names). - Create FRONTIER user name.
- Create FRONTIER user name. - Perform Windows settings.
- Perform Windows settings. (See “Windows Setting” on “6.1.2 Preliminary Work
(See “Windows Setting” on “3.1.2 Preliminary Work for Conditions of DICII (S2) for S9-use Hardware”.)
S2-use Hardware”.) Recovery CD - Set the computer name.
- Set the computer name. Network Environment Settings
Network Environment Settings - Set the IP address and workgroup and disable Firewall.
- Set the IP address and workgroup and disable Firewall. 1394 Driver Settings
Install Windows basic software. - Disable 1394 LAN connection.
- Install MSDE2000. - Preinstall 1394 Driver using 1394 Driver Disk.
- Install IIS. - Install 1394 driver for connecting the scanner.
- Install .Net Framework. - Install 1394 driver for connecting the printer/processor.
* SP2000 is connected via 1394 connection as before.

S2 Installation (See 3.5 on page 41) S9 Installation (See 6.6 on page 141)
Install new S2. S2 is started up automatically. Reinstall S9 using the backup FD.

Optional Software Installation (See 3.6 on page 44) Optional Software Installation (See 6.7 on page 144)
Install S3 (S/T), S4 (or S5), S8 and S12. Install S8 and S12.
* For S8, select “S8&Billing&PL-Maker”. * For S8, select “S8&Billing&PL-Maker”.
* Each software package can be installed consecutively * Each software package can be installed consecutively
without restarting the system. without restarting the system.

After-installation Work (See 3.7 on page 52) After-installation Work (See 6.8 on page 147)
Receipt Printer Installation Maintenance Menu Settings
- Install EPSON driver attached to S8 CD-ROM. - Set installation information (Menu 0140) (Delivery/
- Perform settings for the driver, barcode, IE and StyleSheet. Startup Date).
* Batch file for setting IE is supplied. - Make sure that 1394 connection is enabled at the SP
Install a speaker for notification of sorting of S8. (Fixed to S2) side. (Menu 0145).
Settings by Using Tools * Billing and CD-R writing are to be performed on S2.
- Copy custom data from FD to S2 by using Tools. * When all settings are completed, remove the monitor
- Set PL-Maker product information (by using tools). switcher device from the system.
- Set Media Index (by using tools)
Maintenance Menu Settings
- Equipment Name Set (Menu 0124)
- Set billing environment (Menu 0925).
- Set holiday/opening time (Menu 0927).
- Set media input environment (Menu 0136).
- Set CD-R writing output information (Menu 0137).
- Set photo copy environment (Menu 0138).
- Set index conditions (Menu 0227).
- Perform print condition setup. (Equivalent to the current system)
- Perform settings for conventional red-eye correction
function (Menu 0201).
- Shop Logo Regist/Delete (Menu 1020)
Remote Desktop Settings

Up to here, operations can be performed in parallel.


Perform subsequent operations by connecting all devices (Net).
Start-up Order: [1][2] DICII (S2), LP [3] FMPCII, [4] SP2000

Application Environment Settings (See 9.1 on page 155) Application Environment Settings (See 9.4 on page 169)
Settings by Using Tools Maintenance Menu Settings
- Activate the existing system installation tool after pre- - Set server operation environment (Menu 0922).
operational checks (A1). - Turn ON the rack auto cleaning function.
- Copy the print size settings (from FD to S2) by using Print - Create backup FD for FMPC/printer processor.
Size Copy Tool. - Set timer for printer/processor (Menu 0121).
- Edit user button settings by using Custom Button Setting - Perform maintenance work for the printer/processor.
Tools. (Equivalent to the current system)
Maintenance Menu Settings Settings by Using Tools
- Perform settings for system operation (Menu 0921). - Copy print size settings from FD to S9 by using Print
* Click the [Initialization] button. Size Copy Tool.

END

19
2 Installation Preparations for S1/S2/S7/S9

This chapter explains the required tasks before starting the installation. It is recommended that
these tasks are performed 1 week before the installation, because creating the price list may
take time.

2.1 Print Size Setting Preparations

By using the print Size Copy Tool, you can make the backup of the parameters for print sizes set on
the device, and can copy the parameters it to each device via the FD.
Copy the print size data used in the FRONTIER (SP) to the FD.

2.1.1 Copying Print Size Copy Tool 3 Execute “Tool” -> “PrintSize Tool” -> “Print
(PrintsizeSnc.exe) to FD SizeTool.bat” in the CD drive by selecting [Start]
-> “Run”.
Perform this operation on the general PC.

1 Insert the S1 (S2/S7/S9) CD into the CD drive of


the general PC.

4 The print size copy Tool (PrintsizeSnc.exe) is


copied to the FD.

NMP012
The above PC is used as an example.

2 Insert the blank FD into the FD drive.

5 Remove the FD from the FD drive.

NMP014
The above PC is used as an example.

NMP015
The above PC is used as an example.

20
6 Remove the CD from the CD drive. 2.1.2 Copying Print Sizes from FRONTIER
to FD

By running this tool, the print sizes from the 1st to


50th channel registered in the SP-3000, SP2000/
SP1500, SLP1000/SLP800 and FMPCI can be
backed up.

1 Start up the FRONTIER, then press the [Shift]


key and continue to press it just when the mouse
cursor is changed from “arrow” to “sandglass”
NMP013
after the Windows logo disappears. Release the
The above PC is used as an example.
[Shift] key when the mouse cursor is changed
from “sandglass” to “arrow” again.

2 Insert the FD into the FD drive of the


FRONTIER.

FD042i

3 Start up the “Explorer”, then execute


“PrintsizeSnc.exe” in the FD (normally A drive).

Execute “PrintsizeSnc.exe”.

21
4 In the “Select Mode” dialog box, click the [Read
Reg] button.

Click.

IMPORTANT
Do not remove the FD until the copying of print
sizes is completed.

5 In the confirmation dialog box, click the [Yes]


button.

Click.

6 Loading the print sizes into the FD.

7 In the completion message, click the [OK] button,


then remove the FD from the FD drive.

FD042

8 Later register the print sizes in the FE system in


the “3.7/4.5/5.6/6.8 After-installation Work”.

22
2.2 Billing Data Preparation

2.2.1 Copying the Default Billing Data 4 The following three files are created in the
[PLInit] folder on the Desktop.
Copy the default billing data to the Desktop on the
- PLInit.exe
PC.
- DNA.mdb
- PrintsizeSnc.bin
1 Insert the Pre-setting Tool CD into the CD drive
of the PC.

5 Double-click “PLInit.exe” in the “PLInit” folder on


the Desktop.

NMP012 6 The “Writing of mdb file was completed.”


The above PC is used as an example. message appears on the DOS screen.

2 Insert the FD in which you copied the print sizes


(2.1.2) into the FD drive.

7 The database files (17-digit+mdb) are created in


the [PLInit] folder.

8 Click the [X] button to close the DOS screen.

NMP014 9 Remove the FD from the FD drive.


The above PC is used as an example.

3 Execute “PLMInit” -> “PLInitCopy.bat” in the CD


drive by selecting [Start] -> “Run”.

NMP015
The above PC is used as an example.

23
10 Remove the CD from the CD drive. 2.2.2 Registering the Price List in the
Server Database

Register the Price List in the Database in the


Server. (See the “Frontier Manager (S8) Instruction
Manual [Condition Setup and Maintenance]”.)

NMP013
The above PC is used as an example.

24
3 DICII (S2) Installation

3.1 DICII (S2) Installation Outlines

3.1.1 Installation Procedure

DICII (S2) Installation Procedure

3.2 BIOS Setting and User Registration

3.3 Windows Settings

3.4 Installing Windows Basic Software

3.5 S2 Software Installation

3.6 Optional Software Installation

3.7 After-installation Work

25
3.1.2 Preliminary Work for S2-use Hardware

Before installing DICII Basic Software, the following preliminary work for DICII hardware is required.

BIOS Hyper-threading OFF (See 3.2.1) Hyper-threading ON (See 3.2.1)


OS Windows 2000 SP4 Windows XP Pro. SP2
HDD FD: “A:” drive
CD-ROM: “N:” drive
Total Disk Space: (“C:” and “D:” drives)
40GB: (10GB, 30GB)
80GB: (20GB, 60GB)
160GB: (20GB, 140GB)
“C:” and “D:” drives: NTFS format
User Registration Register the following data. (See 3.2.2)
User name: FRONTIER
Password: FRONTIER
Group: Administrators
Windows Basic Software No. -
[1] Installing MSDE2000 database engine SP3a (See 3.4.1)
[2] Installing IIS (Windows 2000/XP Pro. CD-ROM) (See 3.4.2)
[3] Installing .Net Framework Ver.1.1 (See 3.4.3)
Windows Settings No. [Shaded items can be installed in the one action of executing the batch file.]
[1] - Disabling Windows XP Style (See 3.3.2)
[2] [Date and Time Settings] In “Regional and Language Options”, set the date setting
to “dddd, MMMM, dd, yyyy” and time setting to “24-hour format”.
IMPORTANT Make sure that the time is correctly adjusted on S2. (See 3.3.3)
[3] System Error Setting (See 3.3.4)
[4] - -
[5] Disabling User Assistant Function (See 3.3.5)
[6] Hide Setting of Screen Keyboard Dialog Box (See 3.3.6)
[7] - Disabling Error Reporting (See 3.3.7)
[8] Auto-hide Setting for Task Bar (See 3.3.8) Auto-hide Setting for Task Bar (See 3.3.8)
[9] “Visual Notification” to ON in Dr. Watson Dialog Box (See 3.3.9)
[10] - Disabling Windows Firewall (See 3.3.10)
[11] - Disabling Security Center (See 3.3.11)
[12] - -
[13] Time Zone Setting for each country (See 3.3.12)
[14] - -
[15] LIOS User Registration (See 3.3.13)
[16] Setting IE Page for Receipt Printer (See 3.3.14)
Application Installing Remote Desktop Application -
Computer Name FE-FRONTEND
If the computer name is changed after S2 software installation, the latter must
be reinstalled.
IP Address 192.168.1.12

26
Default gateway 192.168.1.14
DNS primary address 192.168.1.14
Subnet mask 255.255.255.224
Workgroup WORKGROUP

Computer Name, IP Address, etc.:


Set the computer name, IP address, etc. according to the system environment. If acceptable, set the above
values.

IMPORTANT
Do not install the “NetBEUI” protocol.

IMPORTANT
To use the services registered in C5 (Data Writing) on S2, the backup FD must be created on C4/C5 by using
the Custom Data Copy Tool. (See “10.2 Custom Data Copy Tool”.)

27
3.2 BIOS Setting and User Registration

3.2.1 Hyper-threading Setup 2 Enter ‘FRONTIER’ and then click the [Next]
button.
The following procedures are examples. They may
vary depending on the PC.

1 Start up the DICII, then press [FX] key (“X” is


depending on the PC) to display the BIOS
screen.

2 Set “Hyper-threading” to OFF when using


Windows 2000 SP4, to ON when using Windows
XP SP2.

3.2.2 User Registration 3 Select “Computer administrator”, then click the


“Create Account” button.

Register the following user name and password.

USER NAME: FRONTIER


PASSWORD: FRONTIER
GROUP: Administrators

The following procedures are one example when


using the Wizard in the Windows XP.

1 On the Desktop, select [Start] -> “Control Panel”


-> “User Accounts”, then on the “User Accounts”
screen, click “Create a new account”. 4 On the “User Accounts” screen, click the
“FRONTIER” icon.

28
5 Click the “Create a password”. 8 Click the [User Account] button.

6 Enter ‘FRONTIER’ both in the “Type a new


password” and “Type the new password again...”, 9 Click “Change the way users log on or off”.
then click the [Create Password] button.

10 On the “Select logon and logoff options” screen,


7 Close the opened screen with [X] button, then on remove the check mark [✓] from “Use the
the “Control Panel” screen, click “Switch to Welcome screen”, then click the [Apply options]
Classic View”. button.

11 Click the [X] buttons to close all opened screens.

12 Restart the PC.

29
3.3 Windows Settings

3.3.1 Settings Completed with Batch 3.3.2 Disabling Windows XP Style (only
File in Windows XP)

For the items marked with the description (This Set the following item manually by performing Step
setting is done by executing the batch file.), all 1 to 5.
required settings are performed in the one action of
executing the batch file. Insert Basic Software CD-
ROM into the CD-ROM drive and execute the 1 Right-click on any part of Desktop and the select
[Properties].
“BeforeConfig.bat” file in the “N:\Tools\OSAutoConfig”
folder by selecting [Start] -> “Run” on the Desktop.
(Ex: “N:” drive.) After executing a batch file, restart the 2 In the “Theme” tab in the “Display Properties”
screen, select “Windows Classic” for “Theme”
system and perform the settings for other items.
and then click the [OK] button.

After the batch file is executed, set up the items


without shade in 3.2, 3.3, 3.4 manually. These
items cannot be set through the batch file.

Select. Click.

3 Select [Start] -> “Run”. In the “Run” dialog box,


enter ‘Services.msc’ and then click the [OK]
button.
Enter ‘Services.msc’.

Click.

30
4 On the “Services” screen, double-click 3.3.3 [Date and Time Settings] Regional
“Themes”. and Language Settings

(This setting is done by executing the batch file.)

In “Regional and Language Options”, set the date


setting to “dddd, MMMM, dd, yyyy” and time setting
to “24-hour format”.

IMPORTANT
Make sure that the time is correctly adjusted.

Double-Click.

5 On the “Themes Properties” screen, select


“Disabled” for “Startup type”, click the [Stop] 3.3.4 System Error Setting
button and then click the [Apply] -> [OK] button.

(This setting is done by executing the batch file.)

1 Select [Start] -> “Control Panel” -> “System”. In


the “System Properties” screen, click the
“Advanced” tab. Click the [Settings] button in the
“Startup and Recovery” column and then
perform the settings as shown below.

Select.

The above is the example of Windows XP.

- [ ✓]: Write an event to the system log


- [ ✓]: Send an administrative alert
- [ ]: Automatically restart
- [ ✓]: Overwrite any existing file

31
3.3.5 Disabling User Assistant Function 3.3.7 Disabling Error Reporting (only in
Windows XP)
(This setting is done by executing the batch file.)
(This setting is done by executing the batch file.)
1 Select [Start] -> “Control Panel” -> “Accessibility
Options” and then remove all check marks [✓] (to
disable all user assistant functions).
1 Open “Control Panel”.

2 Double-click “System”.

Double-click.

3 In the “System Properties” screen, click the


“Advanced” tab and then click the [Error
Reporting] button.

3.3.6 Hide Setting of Screen Keyboard Click.

Dialog Box

Set the following item manually by performing the


following step.

1 Select [Start] -> “All Programs” -> “Accessories”


-> “Accessibility” -> “On-screen Keyboard”.
Check “Do not show this message again”.

Click.

Check.

32
4 Select “Disable error reporting”, remove the 3.3.8 Auto-hide Setting for Task Bar
check mark [✓] from “But notify me...” and then
click the [OK] button. (Windows XP: The setting is done by executing
Select. the batch file.)
(Windows 2000: Set manually by executing the
following Steps.)

1 On the Desktop, select [Start] -> “Settings” ->


“Taskbar & Start Menu”.

Remove the check mark [✓]. Click.

Select [Start] -> “Settings” -> “Taskbar & Start Menu”.

2 Remove the check mark [✓] from “Keep the


taskbar on top of other windows” and add the
check mark [✓] to “Auto-hide the taskbar”, then
click [Apply] -> [OK].
Remove the check mark [✓].
Add the check mark also [✓].

33
3.3.9 “Visual Notification” to ON in Dr. 3.3.10 Disabling Windows Firewall (only
Watson Dialog Box in Windows XP)

(This setting is done by executing the batch file.) (This setting is done by executing the batch file.)

1 Select [Start] -> “Run”. 1 Open “Control Panel”.

2 Enter “drwtsn32” and click the [OK] button. 2 Double-click “Windows Firewall”.

3 In the “Dr. Watson for Windows” dialog box, add


the check mark [✓] to “Visual Notification”.

4 Click the [OK] button.


Add the check mark [✓].

Double-click.

3 In the “Windows Firewall” -> “General” tab, select


“Off” and then click the [OK] button.

Select. Click.

34
3.3.11 Disabling Security Center (only in 3.3.12 Time Zone Setting (for each
Windows XP) country)

(This setting is done by executing the batch file.) Set the Time Zone and Date & Time appropriate for
the installation location manually.
1 Select [Start] -> “Run”. Enter ‘Services.msc’ and
[Time Zone]
then click the [OK] button.
Enter “Services.msc”.

Click.

2 Double-click “Security Center”.

[Date & Time]

Double-Click.

3 In the “General” tab, select “Manual” for “Startup


type”, click the [Stop] button and then click the
[Apply], then [OK] button.

Select. Click.

35
3.3.13 LIOS User Registration 4 Set all margins (Left, Right, Top and Bottom) to
“0”.
(This setting is done by executing the batch file.)

1 Register the following user using the same


procedures as “3.2.2 User Registration”.

User Name: LIOS


Password: LIOS
Group: Administrators

3.3.14 Setting IE Page for Receipt Printer

Set to “0”.
(This setting is done by executing the batch file.)

IMPORTANT 5 Close the “Page Setup” dialog box, then close


Before this Setting, connect the receipt printer to the Internet Explorer.

S2, S7 or S9.
(See “2.9 Receipt Printer Setting” in “Frontier
Manager II (S8)” Installation Manual.)

1 Start up Internet Explorer.

2 Select “File” -> “Page Setup” to display the “Page


Setup” dialog box.

Select “File” -> “Page Setup”.

3 Leave the “Header” and “Footer” box blank.

36
3.4 Installing Windows Basic Software

Install Windows basic software through the installation menu.


The following procedures use the Windows 2000 as an example.

IMPORTANT Do not install the S2 software here.

1 Insert the S2 install CD into the CD drive.

R3-318

2 The “Program Installation Menu” screen appears.

Three basic types of software are installed in this section.

For the installation of S2 Software, see “3.5 S2 Software Installation”.

IMPORTANT
Make sure to perform the installation in the following order. Check if the
following installation is properly done after “3.5 S2 Software Installation”.

1. Installing MSDE2000 Database Engine SP3a


2. Installing IIS (Internet Information Services)
3. Installing .Net Framework V1.1

37
3.4.1 Installing MSDE2000 database 3.4.2 Installing IIS (Internet Information
engine SP3a Services)

1 In the S2 installation menu, select “MSDE2000 IMPORTANT


SP3a” and click the [Install] button. If the “.Net Framework” exists in the system when
the “IIS (Internet Information Service)” is installed.
Or sometimes, the “.Net Framework” may be
installed in shipping. You can check if the “.NET” is
already installed or not. (See Step 8 in “3.5 S2
Software Installation”.)

Select. Click.
1 In the S2 installation menu, select “IIS Install”.

2 Installation starts. Wait until it is completed.

3 When installation is completed, the following


dialog box appears. Click the [No] button to close
it.

Select. Click.

Click.
2 The “Add/Remove Programs” dialog box
appears. Select “Add/Remove Windows
Components”.

IMPORTANT
Make sure to select the [No] button. Do not
restart the system here.

Select.

38
3 On the “Windows Components Wizard” screen, 4 Perform installation by following the instructions
add the check mark [✓] to “Internet Information displayed on screen.
Services (IIS)” and click the [Next] button.

Add the check mark [✓]. Click.


5 Click the [Finish] button to close Wizard.

IMPORTANT
If the message prompting you to insert the
Windows 2000/XP CD, set it to the CD drive,
then select “\I386” folder of the CD drive. When
the completion message (Step 5) appears,
replace the Windows 2000/XP CD with the S2
CD.

[Windows 2000]

Click.

[Windows XP]

39
3.4.3 Installing .Net Framework V1.1 5 Select [Start] -> “Settings” -> “Control Panel” ->
“Administrative Tools” (on the Windows XP,

1 In the S2 installation menu, select “Microsoft .Net select [Start] -> “Control Panel”. Make sure that
the “Microsoft .NET Framework 1.1
Framework V1.1”.
Configuration” and “Microsoft .NET Framework
1.1 Wizards” shortcut icons are displayed.

Select. Click.

2 When the “Would you like to install Microsoft


.NET Framework 1.1 Package?” message
appears, click the [Yes] button. Make sure that shortcut icons are displayed.

6 Click the [Close] button in the installation menu.


Then, remove the CD from the drive.

Click.

3 In the “License Agreement” dialog box, select


“I agree” and then click the [Install] button. It may
take a little time to install this software.

R3-358

NOTE:
Installing of the S2 software is not performed
here. (See “3.5 S2 Software Installation”.)

Select. Click.
7 Shut down the PC by selecting [Start] -> “Shut
Down” on the Desktop, then restart it.

4 In the completion message, click the [OK] button. IMPORTANT


After the installation of “.Net Framework”, make
sure to restart the system manually.

Click.

40
3.5 S2 Software Installation

IMPORTANT Before the installation, disconnect the DICII (S2) from the LAN. If the installation is done
while the DICII is connected to the LAN, an error may occur.

IMPORTANT Make sure to log on with “FRONTIER”.

1 Insert the S2 installer CD into the CD-ROM 3 When the program installation menu appears,
drive. select “S2 Software”.

Select. Click.

4 In the “Starting Installation” dialog box, click the


[Yes] button.

R3-318

2 If the auto-run function of CD is available, the


installer is automatically started up.
If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

Click the [Yes] button.

5 Installation is started up.

41
6 When installation is completed, the completion (The following is the example of Windows 2000.)
message appears. Remove the CD.
(2) On the Desktop, select [Start] -> “Settings” ->
“Control Panel”.

R3-358

7 Click the [OK] button. The PC is restarted.


Select.

(3) Double-click the “Administrative Tools” icon.

Click.

8 Perform the following procedures.

(1) Restart the S2 PC. When the main menu


screen appears, click the [Shut Down] button
to shut down the S2.
click. Double-click.

(4) Double-click the “Internet Services Manager”


icon (in case of Windows XP, “Internet
Information Services” icon).

Double-click.

42
(5) Select “Internet Information Services” -> “fe- (8) Check if the “.asmx” appears in the
frontend (Computer Name)” -> “Default Web “Application Mapping” list, then click the
Site” -> “WFLIOSOrderSOAP”. [Cancel] button.
(In case of Windows XP, select “Internet Administrative Tools must be closed.
Service Manager” -> “fe-forntend (Computer
Name)” -> “Default Web Site” -> If the “.asmx” appears, proceed to “3.6
“WFLIOSOrderSOAP”). Optional Software Installation”.
If the “.asmx” does not appear, proceed to
Step (9). Administrative Tools must be closed
before performing Step (9).

Select.

(6) Right-click on [WFLIOSOrderSOAP], then


select [Properties].

(9) Insert the S2 installer CD, then select


(double-click) “\Tools\ErrorRecovery\
405Error_MappingRepaire.bat” in the CD
drive.

Right-click. Select.

(7) On the “WFLIOSOrderSOAP” screen, click


the [Configuration] button.

(10) After the process is performed on the DOS


screen, remove the S2 installer CD from the
CD drive, then restart the PC. Proceed to
“3.6 Optional Software Installation”.

Click.

43
3.6 Optional Software Installation

Install the optional software in addition to those already installed.

IMPORTANT
To install the optional software, the Basic Software must be installed beforehand. (See “3.4 Installing
Windows Basic Software” and “3.5 S2 Software Installation”.)

This section assumes that the several optional software programs will be installed at one time. When installing
software individually, use the following procedures.

1. Insert the installer CD into the CD drive if the system is started up.
If the system is shut down, insert the installer CD into the CD drive just after starting up the system.
2. Shut down the system through “Post-operational”.
3. Start up the system.
4. In the “Starting Installation” dialog box, click the [Yes] button to start the installation.
5. Remove the installer CD from the CD drive.
6. Click the [Yes] button to restart the system.

3.6.1 Variety Print Software (S3) (CD-ROM Drive)\EZ171\Setup.exe


Installation

Install the Variety Print Software (S3). For the


installation of templates, see the “Variety Print
Software (S3) Instruction Manual”.

[Applicable Basic Software]


Optional S3 software is available for Basic Software 2 In the “Starting Installation (A-010)” dialog box,
S1, S2 and S7. click the [Yes] button.

1 Insert the S3 installer CD into the CD drive of


DICII.

When the auto-run function of CD is available,


the installer is started up. Click the [Yes] button.
If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
“Run”.

44
3 Installation is started up. 7 Click the [Yes] button to restart the system.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the


[No] button.

4 Registering information is written into the


registry.

5 Environment settings are done.

6 When the “Setup Complete (A-100)” dialog box,


remove the S3 installer CD from the CD drive of
DICII.

45
3.6.2 Tone Selection Software (S4) 4 Registering information is written into the
Installation registry.

Install the Tone Selection Software (S4).

[Applicable Basic Software]


Optional S4 software is available for Basic Software
S1, S2 and S7.

1 Insert the S4 installer CD into the CD drive of


DICII.

When the auto-run function of CD is available,


the installer is started up.
If the auto-run function of CD is not available, 5 Environment settings are done.
execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

2 In the “Starting Installation (A-010)” dialog box,

6
click the [Yes] button.
When the “Setup Complete (A-100)” dialog box,
remove the S4 installer CD from the CD drive of
DICII.

7 Click the [Yes] button to restart the system.

Click the [Yes] button.

3 Installation is started up.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the


[No] button.

46
3.6.3 Professional Color Correction 3 Installation is started up.
Software (S5) Installation

Install the Professional Color Correction Software


(S5).

[Applicable Basic Software]


Optional S5 software is available for Basic Software
S1, S2 and S7.

1 Insert the S5 installer CD into the CD drive of


DICII.

When the auto-run function of CD is available,


the installer is started up.
4 Registering information is written into the
registry.
If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

2 In the “Starting Installation (A-010)” dialog box,


5 Environment settings are done.
click the [Yes] button.

Click the [Yes] button.

6 When the “Setup Complete (A-100)” dialog box,


remove the S5 installer CD from the CD drive of
DICII.

47
7 Click the [Yes] button to restart the system. 3.6.4 Frontier Manager II Software (S8)
Installation

Install the Frontier Manager II (S8)/Billing Software


and PL-Maker.

After removing the CD, click the [Yes] button


to restart the system.
1 On the “Program Installation Menu” screen,
select “S8 software & Billing software & PL-
To install other software consecutively, click the Maker”, then click the [Install] button.
[No] button. Select “S8 software & Billing software & PL-Maker”.

Click the [Install] button.

2 In the “Starting Installation” dialog box, click the


[Yes] button.

Click the [Yes] button.

3 Installation is started up.

48
4 Registering information is written into registry. ■ When the billing is not performed on the
S2, select “S8 Software” on the “Program
Installation Menu” screen.

1 On the “Program Installation Menu” screen,


select “S8 Software”, then click the [Install]
button.

5 Environment settings are done.


Select “S8 Software”. Click the [Install] button.

2 In the “Starting Installation” dialog box, click the


[Yes] button.

Click the [Yes] button.

3 Installation is started up.

6 When the “Setup Complete (A-100)” dialog box,


remove the S8 installer CD from the CD drive of
DICII.

7 Click the [Yes] button to restart the system.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the


[No] button.

49
4 Registering information is written into the 3.6.5 Full Automatic Red-eye Correction
registry. Software (S12) Installation

Install the Full Automatic Red-eye Correction


Software (S12).

[Applicable Software]
Optional S12 Software is available for S1, S2, S7
and S9.
For S1, S2 and S7, optional S3 Software must be
installed in advance.

1 Insert the S12 installer CD into the CD drive of

5
DICII.
Environment settings are done.

When the auto-run function of CD is available,


the installer is started up.
If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

6 When the “Setup Complete (A-100)” dialog box,


remove the S8 installer CD from the CD drive of

2
DICII.
In the “Starting Installation (A-010)” dialog box,

7 Click the [Yes] button to restart the system.


click the [Yes] button.

Click the [Yes] button.


After removing the CD, click the [Yes] button
to restart the system.

To install other software consecutively, click the


[No] button.

50
3 Installation is started up. 6 When the “Setup Complete (A-100)” dialog box,
remove the S12 installer CD from the CD drive of
DICII.

7 Click the [Yes] button to restart the system.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the

4 Registering information is written into the


[No] button.
registry.

5 Environment settings are done.

51
3.7 After-installation Work

3.7.1 Driver Software Installation 3.7.4 Custom Data Copy Tool

Install the driver software for receipt printer. (See (See 10.2.)
“Frontier Manager (S8) Instruction Manual
[Condition Setup and Maintenance]”).
3.7.5 Media Output Setting

Perform this procedure only when the system


3.7.2 Receipt Printer/Barcode Reader includes E-DICII (S7).
Setup
When using the E-DICII (S7), the setting for media
Set up the following items. (See the “Frontier output is required.
Manager II (S8) Installation Manual”.) Set up the PC for media output by using the
procedure below.
(1) Driver software
(2) Barcode reader 1 Insert the S2 installer CD into the CD drive.
(3) Page format on Internet Explorer
(4) Style sheet

3.7.3 Installing the Speaker used for


Indicating Order Completion

When performing KIOSK or NET printing, it is


recommended to use the speaker for noticing the
completion of print. Install it and connect it to PC's
sound output connector.
If the sound board is not installed, install it, then R3-318

connect the speaker to it.


2 Select [(99) Special Operations] -> [(9941)
Explorer].

Select [(99) Special Operations] -> [(9941) Explorer].

52
3 Execute the following file to set up the PC for 3.7.6 LIOS Order Processing Settings
media output.
Perform this procedure only when the system
N:\Tools\OetJobAssignTool\OETASGN.EXE
includes E-DICII (S7).

4 The following dialog box appears.


Specify the PC for the auto image processing
(DICII), manual image processing (E-DICII) and
media writing for Net/Kiosk orders.

1 Make sure that the S2 installer CD is set to the


CD drive, then Select [(99) Special Operations]
-> [(9941) Explorer].

5 In the “CD-R Write PC” edit box, enter the name


of the PC for media output.

6 Add the check mark [✓] to the “Screen Control


Setting” checkbox, so that WFA is used as Home
Screen.

NOTE:
This checkbox is effective only when S8 is
installed, but displayed even when S8 is not
installed.
Select [(99) Special Operations] -> [(9941) Explorer].

7 Click the [OK] button.

2 Execute the following file to set up the PC for


media output.

N:\Tools\LiosJobAssignTool\LiosAsgn.exe

3 The following dialog box appears.

Click.

8 Proceed to “3.7.6 LIOS Order Processing


Settings”.

Make sure that the installer CD is set to the CD


drive.

4 In the “Auto Image-Processing PC” edit box,


enter the name of the PC for auto image
processing (normally “FE-FRONTEND”, the
computer name for DICII).

53
5 In the “Manual Image-Processing PC” edit box, 3.7.7 PLMaker Setting
enter the name of the PC for manual image
processing (normally “FE-C-FRONTEND”, the Set up the PLMaker product information. (See
computer name for E-DICII).
“Frontier Manager (S8) Instruction Manual

6 In the “CD-R Write PC” edit box, enter the name [Condition Setup and Maintenance]”.)
of the PC for media output (normally “FE-C-
FRONTEND”, the computer name for E-DICII).
3.7.8 Media Index Setting
7 Click the [OK] button.
Set up the small and large index for digital service
(for orders from KIOSK, NET and Order Entry
[OES]). Select the service, then add check mark to
“Small Index” or “Large Index” one by one.

1 Insert the S2 installer CD into the CD drive.

Click.

8 Remove the installer CD from the CD drive.

R3-318

2 Select [(99) Special Operations] -> [(9941)


Explorer], then execute the following file.
R3-358
N:\Tools\MediaIndexSettingTool
\DigitalMediaIndexSetting.exe

3 The following dialog box appears.

54
4 Select the service name in the left-hand list box,
then add the check mark [✓] to “Small Index” and
“Large Index”. (Selecting of any or both of
indexes is available.)

Select the service name. Add the check mark [✓].

5 Select the service name and add the check mark


one by one for other as in the Step 4.

6 Click the [Close] button.

55
3.7.9 Holiday/Opening Time Setup (0927)

[Selection]
“Setup and Maintenance” -> [(09) Order Control and Maintenance] -> [(0927) Holiday/Opening Time Setup]

[Procedure]
Set up the holidays and working days and times.

2 3 4

5
6
9

7 8

1 Perform the holiday and opening time settings referring the following table.

No. Item Description


1 Day Select the working days (multiple available).
Day not checked [✓] as a holiday.

56
No. Item Description
2 Opening Set up the opening time of the day.
Range: 1:00 A.M to 12:59 P.M

3 Closing Set up the closing time of the day.


Range: 1:00 A.M to 12:59 P.M

4 List Lists up the selected holidays with the holiday name and its date.

5 Name Enter the holiday name.


Range: up to 20 characters
The holiday selected in the above list appears.
6 Date Selects the date for holiday from the pull-down list, if the holidays
are registered.
The Y/M/D of the holiday selected in the list appears.
Range: 1980/01/01 to 2099/12/31

57
No. Item Description
7 [Add] Button Adds the holiday and its date.

If the date is duplicated, the error message appears. In this case,


the setting is returned to its former state.
(See “3.2.7 Holiday/Opening Time Setup (0927)” in the “Frontier
Manager II (S8) Installation Manual”.)
8 [Modify] Button Changes the registered holiday information.
Select the existing holiday in the list, then click this button.
If the date is duplicated, the error message appears. In this case,
the setting is returned to its former state.
(See “3.2.7 Holiday/Opening Time Setup (0927)” in the “Frontier
Manager II (S8) Installation Manual”.)
9 [Delete] Button Deletes the selected holiday information.

The button is active only when the holiday is selected in the list.
(See “3.2.7 Holiday/Opening Time Setup (0927)” in the “Frontier
Manager II (S8) Installation Manual”.)

2 Click the [OK] button.

• Operation returns to the menu screen.

58
3.7.10 Media Input Environment Setup 3.7.11 Writing Service Settings (0137)
(0136)
Set up the items required for the CD-R writing
Perform media drive settings for importing image service.
data.
1 Select [(01) System Operation Setup and Check]
IMPORTANT -> [(0137) Writing Service Output Settings].
Before this setting, confirm the drive letter of each
media drive by using the Explorer.

1 Select [(01) System Operation Setup and Check]


-> [(0136) Media Input Environment Setup].

Select [(01) System Operation Setup and Check] ->


[(0137) Writing Service Output Settings].

2 Set up the items required for CD-R drive, CD-


ROM drive and media drives and then click the
Select [(01) System Operation Setup and Check] -> [OK] button.
[(0136) Media Input Environment Setup].

2 Set up the required media drive for input, then


click the [OK] button.

Click.

Click.

59
3.7.12 Photo Copy Configuration (0138) 2 Select the scanner source name (logical device
name) in the [TWAIN Source] list.
IMPORTANT
Before this setting, install the TWAIN driver in the
PC and connect the scanner to the PC.

TWAIN: API (Application Program Interface) and


protocol for image input device.

[Selection]
“Setup and Maintenance” -> [(01) System
Operation Setup and Check] -> [(0138) Photo Copy
Configuration] 3 Click the [OK] button.

[Procedure] • Operation returns to the menu screen.


Set up the flatbed scanner information for photo
copy service (Printing from Print).

1 Select the model name of the connected


scanner in the [Device Name] list.

60
3.7.13 Index Conditions (0227) <Index for Media>

[Selection] 1 Click the “Index for Media” tab.


“Setup and Maintenance” -> [(02) Print Condition
Setup and Check] -> [(0227) Index Conditions]

[Procedure]
Select the condition of the index printing and large
index printing.

2 Click the [▼] button in the box to be changed and


select the logo.

Logo: FUJICOLOR*INDEX PRINT


FUJICOLOR INDEX PRINT
INDEX PRINT
Index Custom Logo:
<Media> Can be registered on Menu 1020.

1 Click the [▼] button in the box to be changed and


3 Click the [OK] button.
select the logo.
• Operation returns to the menu screen.

3.7.14 Print Condition Setup

Perform the “Print Condition Setup and Check”


menus other than menus 0227 and 0201.

Logo: FUJICOLOR*INDEX PRINT


FUJICOLOR INDEX PRINT
INDEX PRINT
Index Custom Logo:
Can be registered on Menu 1020.

2 Click the [OK] button.

• Operation returns to the menu screen.

61
3.7.15 Equipment Name Set (0124) 3.7.16 Red Eye Correction Setup (0201)
(only in case of the Earlier-type
[Selection] System)
“Setup and Maintenance” -> [(01) System
Operation Setup and Check] -> [(0124) Equipment [Selection]
Name Set] “Setup and Maintenance” -> [(02) Print Condition
Setup and Check] -> [(0201) Red Eye Correction
[Procedure] Setup]
Set up the device name to be used in the system
and its identifier when creating an order. [Procedure]
When using the FRONTIER 330/340E/350/370 as
1 Set up the following items. printer, set up the red-eye correction items. (See
“Full Automatic Red-Eye Correction Software
- Device Name: Unique Device Name for Instruction Manual”.)
Imaging Controller
- Order Identifier: Unique lower-case alphabet
(This is added to the order No.)

2 Click the [OK] button.

• Operation returns to the menu screen.

62
3.7.17 Billing Environment Setup (0925)

[Selection]
“Setup and Maintenance” -> [(09) Order Control and Maintenance] -> [(0925) Billing Environment Setup]

[Procedure]
Set up the items for performing the billing. (See “Frontier Manger Instruction Manual [Condition Setup]”)

3.7.18 Shop Logo Regist/Delete (1020)

1 Select the [(10) Register/Delete] -> [(1020) Shop Logo Regist/Delete] button.

2 Setup the shop logo. For settings, see the “S2 Instruction Manual (Condition Setup and Maintenance)”.

Note that the same shop logo must be set up for S2 and S7.

63
3.7.19 Remote Desktop Settings (only in 3 In the “License Agreement” screen, select
use of FMPC in the Earlier-type “I accept...” and then click the [Next] button.
System)

To switch the screen display between FMPCII and


DICII, the Remote Desktop Client must be
installed.

IMPORTANT
When using S2 on the Windows XP, it is not
necessary to install the following Remote Desktop
Client. In this case, start the operation from
“Remote Desktop Setting” shown on page 65.
Select. Click the [Next] button.

[Installing Remote Desktop Client]


4 Enter the following information and then click the
[Next] button.

1
(1) User Name: Enter ‘FRONTIER’.
Open the “Driver” -> “RemoteDesktop” folder in
(2) Organization: Leave this box blank.
the S2 installer disk and then double-click the
(3) Install this application for: Select “Only for me”.
“msrdpcli” icon.
Enter ‘FRONTIER’. Leave this box blank.

2 “InstallShield Wizard” appears. Click the [Next]


button.

Select “Only for me”. Click the [Next] button.

Click the [Next] button.


5 Click the [Install] button to start installation.

Click the [Install] button.

64
6 Installation is started. 3 The following dialog box appears. Copy
‘FRONTIER’ in the “User name” box and paste it
in the “Password” box.
Copy ‘FRONTIER’.

7 When installation is completed, the following


dialog box appears. Click the [Finish] button.

Paste it.

4 Check [✓] the “Save my password” check box


and then click the [Save As] button.

Click the [Finish] button.

[Remote Desktop Setting]

Perform the settings for switching the screen


between S2 and FMPCII.

1 Insert S2 installer CD Software into the CD-ROM


drive to execute “AfterConfig.bat” in
“N:\Tools\OSAutoConfig”.

2 “FMPCNameSetTool” dialog box appears in a


command prompt screen. Enter the name of the
FMPC to be connected and then click the [OK]
button. Check [✓]. Click the [Save AS] button.

65
5 The following dialog box appears. Click the 3.7.20 Setting the HELP
[Save] button to overwrite the file.
Install the HELP manuals which are displayed by
clicking the [Help] button at the upper right-hand
side of the screen.

Click the [Save] button.

6 Operation returns to the following dialog box.


Click the [Cancel] button and then restart the
system.

[Manual Installation Procedures]


Click the [Cancel] button.
1 Insert the manual CD into the CD drive.

C5R015

66
2 The “Installation menu” screen appears. 5 Upon completion of installation, remove the
manual CD from the CD drive.

If the “Installation menu” screen doesn't appear,


run “\EZ171\Setup.exe” on the CD drive.
C5R017
Enter ‘\EZ171\Setup.exe’.

6 In the “Installed successfully” dialog box, click


the [OK] button.

Click.

Click.
3 Select “Manuals”, then click the [Start
installation] button. When the manual is reinstalled, the following
dialog appears in this step. In this case, click the
Select [Manuals].
[Yes to All] button.

Click.

4 Installation is started. Click.

7 To complete the installation, click the [Exit]


button.

Click.

67
8 In the “Restarting Windows” dialog box, click the 3 On the “Setup Start” screen, click the [Next]
[Yes] button. button.

Click.

[Adobe Reader Installation Procedures]

1 Select “Adobe Reader”, then click the [Start


Click the [Next] button.
installation] button.
Select “Adobe Reader”.
4 On the “Welcome to the Setup Wizard...” screen,
click the [Next] button.

Click.

2 Installing process is started.

Click the [Next] button.

5 On the “Destination Folder” screen, click the


[Next] button.

Click the [Next] button.

68
6 On the “Ready to Install the Program” screen, 9 Control returns to the “Installation menu” screen.
click the [Install] button.

10 Remove the manual CD from the CD drive.

Click the [Install] button.

7 The program is installed.

C5R017

11 On the “Installation menu” screen, click the [Exit]


button.

8 On the “Setup Wizard Completed” screen, click


the [Finish] button.

Click.

12 In the “Restarting Windows” dialog box, click the


[Yes] button.

Click.

Click the [Finish] button.

69
4 SP (S1) Installation

4.1 SP (S1) Installation Outlines

4.1.1 Installation Procedure

SP (S1) Installation Procedure

4.2 Windows Settings

4.3 S1 Software Installation

4.4 Optional Software Installation

4.5 After-installation Work

4.1.2 Preliminary Work for S1-use Hardware (SP-3000)

■ Conditions

Setting the computer name, IP address, etc.

Set the computer name, IP address, etc. according to the system environment. If acceptable, set the following
values.

Computer Name FE-EZPC00


If the computer name is changed after S1 Software
installation, the latter must be reinstalled.
IP address 192.168.1.2
Default gateway address 192.168.1.14
DNS primary address 192.168.1.14
Subnet mask 255.255.255.224
Workgroup WORKGROUP

IMPORTANT Do not install the “NetBEUI” protocol.

70
4.2 Windows Settings

4.2.1 [Date and Time Settings] Regional 4.2.3 “Rollup 35” Installation Procedure
and Language Settings
Run the patch program using the “OS SP4 +
In “Regional and Language Options”, set the date Rollup35” CD.
setting to “dddd, MMMM, dd, yyyy” and time setting
to “24-hour format”. The “OS SP4 + Rollup35” CD includes the Windows
2000 Service Pack 4 (hereafter “SP4”), several Hotfix
IMPORTANT files, and Rollup35 correction program.
Make sure that the time is correctly adjusted.
When the SP3000 Main Control Unit (hereafter “S1
PC”) uses the Windows 2000 SP4, only the Rollup35
is installed in the Main Control Unit.
4.2.2 Time Zone Setting (for each When the S1 PC uses the Windows 2000 SP2, all
country) Hotfix files (with SP4) are installed in the Main Control
Unit.
Set the Time Zone and Date & Time appropriate for This procedure should be done before the S1
the installation location manually. software installation or upgrading (See 4.3).
[Time Zone]
1 Start up the Main Control Unit(S1 PC) while
pressing [CTRL] key.

2 After the PC is started up, insert the “OS SP4 +


Rollup35” CD into the CD drive of the S1 PC.

[Date & Time]

ZII043

3 When the message “Do you want to update the


system?” appears, press the [y] key.

71
4 The Hotfix files are copied into the S1 PC. 7 When the Installation is completed, the
completion message appears. Press any key to
stop the program.

5 Then, Installation of the SP4 is started


automatically.
When the Installation is completed, the S1 PC is 8 When the message “It is now safe to turn off your
automatically restarted. Computer” appears, shut down the S1 PC
manually.
When the Windows 2000 SP4 is used, this
process is skipped. (Refer to Step 6)

NMP010r

6 After the S1 PC is started up, the installation of


Hotfix files will continue.

72
4.3 S1 Software Installation (Upgrading from A1 to S1)

Before installing S1 software, perform "4.1.2" and "4.2".

IMPORTANT Make sure that the FRONTIER system software [A1] version is 1.7 or 1.8.

IMPORTANT Before starting the S1 installation, disconnect the S1 (SP) from the LAN.

1 Display FRONTIER system [A1] main menu and 2 Turn off SP-3000 after inserting the S1
click [Setup and Maintenance], then open the installation CD in CD drive. Next, turn on SP-
“Installation Information Setup [0140]” after 3000.
entering the password ‘7777’.

ZII043

[1] When the output device (FRONTIER) is 3 The installer is started automatically and the
directly connected through SP-3000, make following dialog box is displayed. Select [Yes] to
sure that the devices are connected, then start upgrade processing.
check that the output device model
connected is chosen.

[2] When the FMPC is included in the system,


select [OFF] and then remove 1394 cables
from the SP-3000.
Select.

Create the backup FD of an output device The Windows installer (DOS screen) may be
(FRONTIER) (“Data Backup [0122]”) before installed before the installation is started.
performing the above procedure [2]. When
moving from the system without FMPC to the
one with FMPCII (S9), create the backup FD at
the time of S9 installation.

73
4 Installation is started. 7 Remove the CD and then click the [OK] button.
Operation returns to the Desktop screen.

ZII044

5 Control software is transferred to the circuit


board. (It takes about 7 minutes for transferring 8 Select [Start] -> “Shutdown” to restart the
the two kinds of software to the circuit boards. system.
Wait until the screen is changed.)

6 When installation is completed, the completion


message appears.

74
4.4 Optional Software Installation

Install the optional software in addition to those already installed.

IMPORTANT
To install the optional software, the Basic Software must be installed beforehand (See “4.3 S1 Software
Installation (Upgrading from A1 to S1)”).

This section assumes that the several optional software programs will be installed at one time. When installing
software individually, use the following procedures.

1. Insert the installer CD into the CD drive if the system is started up.
If the system is shut down, insert the installer CD into the CD drive just after starting up the system.
2. Shut down the system through “Post-operational”.
3. Start up the system.
4. In the “Starting Installation” dialog box, click the [Yes] button to start the installation.
5. Remove the installer CD from the CD drive.
6. Click the [Yes] button to restart the system.

4.4.1 Variety Print Software (S3) 2 In the “Starting Installation (A-010)” dialog box,
Installation click the [Yes] button.

Install the Variety Print Software (S3). For the


installation of templates, see the “Variety Print
Software (S3) Instruction Manual”.

Click the [Yes] button.


[Applicable Basic Software]
Optional S3 software is available for Basic Software
S1, S2 and S7. 3 Installation is started up.

1 Insert the S3 installer CD into the CD drive of SP.

When the auto-run function of CD is available,


the installer is started up.
If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

75
4 Registering information is written into the 4.4.2 Tone Selection Software (S4)
registry. Installation

Install the Tone Selection Software (S4).

[Applicable Basic Software]


Optional S4 software is available for Basic Software
S1, S2 and S7.

1 Insert the S4 installer CD into the CD drive of SP.

When the auto-run function of CD is available,


the installer is started up.
If the auto-run function of CD is not available,
5 Environment settings are done. execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

2 In the “Starting Installation (A-010)” dialog box,


click the [Yes] button.

6 When the “Setup Complete (A-100)” dialog box,


remove the S3 installer CD from the CD drive of
SP.

7 Click the [Yes] button to restart the system.


Click the [Yes] button.

3 Installation is started up.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the


[No] button.

76
4 Registering information is written into the 4.4.3 Professional Color Correction
registry. Software (S5) Installation

Install the Professional Color Correction Software


(S5).

[Applicable Basic Software]


Optional S5 software is available for Basic Software
S1, S2 and S7.

1 Insert the S5 installer CD into the CD drive of SP.

When the auto-run function of CD is available,


the installer is started up.

5 Environment settings are done. If the auto-run function of CD is not available,


execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

2 In the “Starting Installation (A-010)” dialog box,


click the [Yes] button.
6 When the “Setup Complete (A-100)” dialog box,
remove the S4 installer CD from the CD drive of
SP.

7 Click the [Yes] button to restart the system.

Click the [Yes] button.

3 Installation is started up.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the


[No] button.

77
4 Registering information is written into the 4.4.4 Frontier Manager II Software (S8)
registry. Installation

Install the Frontier Manager II (S8)/Billing Software


only.

1 On the “Program Installation Menu” screen,


select “S8 Software”, then click the [Install]
button.

5 Environment settings are done.

Select [S8 Software]. Click the [Install] button.

2 In the “Starting Installation” dialog box, click the


[Yes] button.

Click the [Yes] button.

6 When the “Setup Complete (A-100)” dialog box, 3 Installation is started up.
remove the S5 installer CD from the CD drive of
SP.

7 Click the [Yes] button to restart the system.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the


[No] button.

78
4 Registering information is written into the 4.4.5 Full Automatic Red-eye Correction
registry. Software (S12) Installation

Install the Full Automatic Red-eye Correction


Software (S12).

[Applicable Software]
Optional S12 Software is available for S1, S2, S7
and S9.

1 Insert the S12 installer CD into the CD drive of


SP.

When the auto-run function of CD is available,


5 Environment settings are done. the installer is started up.
If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

6 When the “Setup Complete (A-100)” dialog box,


2 In the “Starting Installation (A-010)” dialog box,
remove the S8 installer CD from the CD drive of click the [Yes] button.
SP.

7 Click the [Yes] button to restart the system.

Click the [Yes] button.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the


[No] button.

79
3 Installation is started up. 6 When the “Setup Complete (A-100)” dialog box,
remove the S12 installer CD from the CD drive of
the DICII.

7 Click the [Yes] button to restart the system.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the

4 Registering information is written into the


[No] button.
registry.

5 Environment settings are done.

80
4.5 After-installation Work

4.5.1 Remote Desktop Settings (Only 4 Enter the following information and then click the
when using the FMPCII) [Next] button.

(1) User Name: Enter ‘FRONTIER’.


To switch the screen display between FMPCII and (2) Organization: Leave this box blank.
DICII, the Remote Desktop Client must be installed. (3) Install this application for: Select “Only for me”.
Enter ‘FRONTIER’. Leave this box blank.

[Installing Remote Desktop Client]

1 Open the “Driver” -> “RemoteDesktop” folder in


the S1 installer CD and then double-click the
“msrdpcli” icon.

2 “InstallShield Wizard” appears. Click the [Next]


button.

Select “Only for me”. Click the [Next] button.

5 Click the [Install] button to start installation.

Click the [Next] button.

3 In the “License Agreement” screen, select


“I accept...” and then click the [Next] button.

Click the [Install] button.

6 Installation is started.

Select. Click the [Next] button.

81
7 When installation is completed, the following [Remote Desktop Setting]
dialog box appears. Click the [Finish] button.
Perform the settings for switching the screen
between S1 and FMPCII.

1 On SP-3000, make a shift-start. Insert S1


Software into the CD-ROM drive to execute
“AfterConfig.bat” in “N:\Tools\OSAutoConfig”.

2 “FMPCNameSetTool” dialog box appears in a


command prompt screen. Enter the name of
FMPC to be connected and then click the [OK]
button.

Click the [Finish] button.

3 The following dialog box appears. Copy


‘FRONTIER’ in the “User name” box and paste it
in the “Password” box.
Copy ‘FRONTIER’.

Paste it.

82
4 Check [✓] the “Save my password” checkbox 6 Operation returns to the following dialog box.
and then click the [Save As] button. Click the [Cancel] button and then restart the
system.

Check [✓]. Click.


Click.

5 The following dialog box appears. Click the


[Save] button to overwrite the file.

Click.

83
4.5.2 Copying Print Sizes from 4 The print size copy Tool (PrintsizeSnc.exe) is
FRONTIER to FD copied to the FD.

Copying Print Size Copy Tool (PrintsizeSnc.exe)


to FD

Perform this operation on S1 PC.

1 Insert the S1 (S2/S7/S9) CD into the CD drive of


the PC.

5 Remove the FD from the FD drive.

ZII043

2
FD042
Insert the blank FD into the FD drive.

6 Remove the CD from the CD drive.

FD042i

ZII044

3 Execute “Tool” -> “PrintSize Tool” -> “Print


SizeTool.bat” in the CD drive by selecting [Start]
-> “Run”.

84
Copying Print Sizes from FRONTIER to FD 4 In the “Select Mode” dialog box, click the [Read
Reg] button.

1 Start up the FRONTIER, then press the [Ctrl] key


and continue to press it just when the mouse
cursor is changed from “arrow” to “sandglass”
after the Windows logo disappears. Release the
[Shift] key when the mouse cursor is changed
from “sandglass” to “arrow” again.
Click.
2 Insert the FD into the FD drive of the
FRONTIER. IMPORTANT
Do not remove the FD until the copying of print
sizes is completed.

5 In the confirmation dialog box, click the [Yes]


button.

Click.
FD042i

6 Loading the print sizes into the FD.

3 Start up the “Explorer”, then execute


“PrintsizeSnc.exe” in the FD (normally A drive).

7 In the completion message, click the [OK] button,


then remove the FD from the FD drive.

Execute “PrintsizeSnc.exe”.

FD042

85
4.5.3 Media Output Setting 5 In the “CD-R Write PC” edit box, enter the name
of the PC for media output.
Perform this procedure only when the system
includes E-DICII (S7). 6 Add the check mark [✓] to the [Screen Control
Setting] checkbox, so that WFA is used as Home
Screen.
When using the E-DICII (S7), the setting for media
output is required. NOTE:
Set up the PC for media output by following the This checkbox is effective only when S8 is
procedure below. installed, but displayed even when S8 is not
installed.

1 Insert the S1 installer CD into the CD drive.


7 Click the [OK] button.

Click.

C5R015 8 Remove the installer CD from the CD drive.

2 Select [(99) Special Operations] -> [(9941)


Explorer].

3 Execute the following file to set up the PC for


media output.

N:\Tools\OetJobAssignTool\OETASGN.EXE

4 The following dialog box appears.


C5R017

86
4.5.4 Scanner Parameter Check/Update [Selection]
(0350) “Setup and Maintenance” -> [(03) Scanner
Adjustment/Maintenance] -> [(0350) Scanner
This menu check parameter saved in the EEPROM Parameter Check/Update]
of the CTB23, CLE23, CCD23 circuit boards and
the HD of the main control unit, then displays the
result by “OK” or “NG”.

If “NG” is displayed, the [Storage] and [Reading]


buttons become effective.

[Storage] button:
Saves the parameters from the circuit board
into the HD when the system software (A1) is
newly installed.

[Reading] button:
Reads the parameters saved in the HD and ● Storage
writes them into the new circuit board when Each button becomes effective when the system
the circuit board has been replaced. software (A1) is newly installed.

[FD reading] button:


1 Click the [Storage] button.
Reads the displacement parameters from the
FD and writes them into the CPZ23 circuit 2 Click the [OK] button.
board and the HD when the CCD unit has
• The parameters in the EERROM are saved into
been replaced.
the HD.

3 Click the [Close] button.

• Operation returns to the menu screen.

87
4.5.5 Scanner and Carrier Adjustment/ 4.5.7 Installation Information Setup
Maintenance menus (0140)

Perform the “Scanner Adjustment/Maintenance” 1 Select the [(01) System Operation Setup and
and “Carrier Adjustment/Maintenance” menus. Check] -> [(0140) Installation Information Setup]
buttons.

4.5.6 Equipment Name Set (0124)

1 Select the [(0124) Equipment Name Set] button.

2 Set the “External File I/O” to “Yes”.

3 Enter the delivery date and the startup date for


the machine.

4 Enter the Lab ID using the full keyboard.


2 Set up the following items.
5 Click the [OK] button.
- Device Name: Unique Device Name for
Scanner or Imaging Controller NOTE:
- Order Identifier: Unique lower-case alphabet The settings are available when the machine
(This is added to the order No.) is restarted.

3 Click the [OK] button.

88
4.5.8 Shop Logo Regist/Delete (1020) 4.5.9 Setting the HELP

1 Select the [(10) Register/Delete] -> [(1020) Shop See “3.7.20 Setting the HELP” on page 66.
Logo Regist/Delete] button.

2 Setup the shop logo. For settings, see the “S1


Instruction Manual (Condition Setup and
Maintenance)”.

Note that the same shop logo must be set up for


S2 and S7.

89
5 E-DICII (S7) Installation

5.1 E-DICII (S7) Installation Outlines

5.1.1 Installation Procedure

E-DICII (S7) Installation Procedure

5.2 BIOS Setting and User Registration

5.3 Windows Settings

5.4 S7 Software Installation

5.5 Optional Software Installation

5.6 After-installation Work

90
5.1.2 Preliminary Work for S7-use Hardware

Before installing S7 (E-DICII Basic Software), the following preliminary work for E-DICII hardware is
required.
BIOS Hyper-threading OFF (See 5.2.1) Hyper-threading ON (See 5.2.1)
OS Windows2000 SP4 Windows XP Pro. SP2
HDD FD: “A:” drive
CD-ROM: “N:” drive
Total Disk Space: (“C:” and “D:” drives)
40GB: (10GB, 30GB)
80GB: (20GB, 60GB)
160GB: (20GB, 140GB)
“C:” and “D:” drives: NTFS Format
User Registration Register the following data. (See 5.2.2)
User Name: FRONTIER
Password: FRONTIER
Group: Administrators
Windows Settings No. [Shaded items can be installed in the one action of executing the batch file.]
[1] - Disabling Windows XP Style (See 5.3.2)
[2] [Date and Time Settings] In “Regional and Language Options”, set the date setting
to “dddd, MMMM, dd, yyyy” and time setting to “24-hour format”. (See 5.3.3)
[3] System Error Setting (See 5.3.4)
[4] -
[5] Disabling User Assistant Function (See 5.3.5)
[6] Hide Setting of Screen Keyboard Dialog Box (See 5.3.6)
[7] - Disabling Error Reporting (See 5.3.7)
[8] Auto-hide Setting for Task Bar (See 3.3.8) Auto-hide Setting for Task Bar (See 5.3.8)
[9] “Visual Notification” to ON in Dr. Watson Dialog Box (See 5.3.9)
[10] - Disabling Windows Firewall (See 5.3.10)
[11] - Disabling Security Center (See 5.3.11)
[12] -
[13] Time Zone Setting for each country (See 5.3.12)
[14] -
[15] LIOS User Registration (See 5.3.13)
[16] Setting IE page for Receipt Printer (See 5.3.14)
Application Installing Remote Desktop Application -
Computer Name FE-C-FRONTEND
IP Address 192.168.1.15
Default gateway 192.168.1.14
DNS primary address 192.168.1.14
Subnet mask 255.255.255.224
Workgroup WORKGROUP

Computer Name, IP Address, etc.:


Set the computer name, IP address, etc. according to the system environment. If acceptable, set the above
values.

IMPORTANT Do not install the “NetBEUI” protocol.

91
5.2 BIOS Setting and User Registration

5.2.1 Hyper-threading Setup 2 Enter ‘FRONTIER’ and then click the [Next]
button.
The following procedures are examples. They may
vary depending on the PC.

1 Start up the DICII, then press [FX] key (“X” is


depending on the PC) to display the BIOS
screen.

2 Set “Hyper-threading” to OFF when using


Windows 2000 SP4, to ON when using Windows
XP SP2.

5.2.2 User Registration 3 Select “Computer administrator”, then click the


“Create Account” button.

Register the following user name and password.

USER NAME: FRONTIER


PASSWORD: FRONTIER
GROUP: Administrators

The following procedures are one example when


using the Wizard in the Windows XP.

1 On the Desktop, select [Start] -> “Control Panel”


-> “User Accounts”, then on the “User Accounts”
screen, click “Create a new account”. 4 On the “User Accounts” screen, click the
“FRONTIER” icon.

92
5 Click the “Create a password”. 8 Click the [User Account] button.

6 Enter ‘FRONTIER’ both in the “Type a new


password” and “Type the new password again...”, 9 Click “Change the way users log on or off”.
then click the [Create Password] button.

10 On the “Select logon and logoff options” screen,


7 Close the opened screen with [X] button, then on remove the check mark [✓] from “Use the
the “Control Panel” screen, click “Switch to Welcome screen”, then click the [Apply options]
Classic View”. button.

11 Click the [X] buttons to close all opened screens.

12 Restart the PC.

93
5.3 Windows Settings

5.3.1 Settings Completed with Batch 5.3.2 Disabling Windows XP Style (only
File in Windows XP)

For the items marked with the description (This Set the following item manually by performing Step
setting is done by executing the batch file.), all 1 to 5.
required settings are performed in the one action of
executing the batch file. Insert Basic Software CD-
ROM into the CD-ROM drive and execute the 1 Right-click on any part of Desktop and the select
[Properties].
“BeforeConfig.bat” file in the “N:\Tools\OSAutoConfig”
folder by selecting [Start] -> “Run” on the Desktop.
(Ex: “N:” drive.) After executing a batch file, restart the 2 In the “Theme” tab in the “Display Properties”
screen, select “Windows Classic” for “Theme”
system and perform the settings for other items.
and then click the [OK] button.

After the batch file is executed, set up the items


without shade in 3.2, 3.3, 3.4 manually. These
items cannot be set through the batch file.

Select. Click.

3 Select [Start] -> “Run”. In the “Run” dialog box,


enter ‘Services.msc’ and then click the [OK]
button.
Enter ‘Services.msc’.

Click.

94
4 On the “Services” screen, double-click 5.3.3 [Date and Time Settings] Regional
“Themes”. and Language Settings

(This setting is done by executing the batch file.)

In “Regional and Language Options”, set the date


setting to “dddd, MMMM, dd, yyyy” and time setting
to “24-hour format”.

IMPORTANT
Make sure that the time is correctly adjusted.

Double-Click.

5 On the “Themes Properties” screen, select


“Disabled” for “Startup type”, click the [Stop] 5.3.4 System Error Setting
button and then click the [Apply] -> [OK] button.

(This setting is done by executing the batch file.)

1 Select [Start] -> “Control Panel” -> “System”. In


the “System Properties” screen, click the
“Advanced” tab. Click the [Settings] button in the
“Startup and Recovery” column and then
perform the settings as shown below.

Select.

The above is the example of Windows XP.

- [ ✓]: Write an event to the system log


- [ ✓]: Send an administrative alert
- [ ]: Automatically restart
- [ ✓]: Overwrite any existing file

95
5.3.5 Disabling User Assistant Function 5.3.7 Disabling Error Reporting (only in
Windows XP)
(This setting is done by executing the batch file.)
(This setting is done by executing the batch file.)
1 Select [Start] -> “Control Panel” -> “Accessibility
Options” and then remove all check marks [✓] (to
disable all user assistant functions).
1 Open “Control Panel”.

2 Double-click “System”.

Double-click.

3 In the “System Properties” screen, click the


“Advanced” tab and then click the [Error
Reporting] button.

5.3.6 Hide Setting of Screen Keyboard Click.

Dialog Box

Set the following item manually by performing the


following step.

1 Select [Start] -> “All Programs” -> “Accessories”


-> “Accessibility” -> “On-screen Keyboard”.
Check “Do not show this message again”.

Click.

Check.

96
4 Select “Disable error reporting”, remove the 5.3.8 Auto-hide Setting for Task Bar
check mark [✓] from “But notify me...” and then
click the [OK] button. (Windows XP: The setting is done by executing
Select. the batch file.)
(Windows 2000: Set manually by executing the
following Steps.)

1 On the Desktop, select [Start] -> “Settings” ->


“Taskbar & Start Menu”.

Remove the check mark [✓]. Click.

Select [Start] -> “Settings” -> “Taskbar & Start Menu”.

2 Remove the check mark [✓] from “Keep the


taskbar on top of other windows” and add the
check mark [✓] to “Auto-hide the taskbar”, then
click [Apply] -> [OK].
Remove the check mark [✓].
Add the check mark also [✓].

97
5.3.9 “Visual Notification” to ON in Dr. 5.3.10 Disabling Windows Firewall (only
Watson Dialog Box in Windows XP)

(This setting is done by executing the batch file.) (This setting is done by executing the batch file.)

1 Select [Start] -> “Run”. 1 Open “Control Panel”.

2 Enter “drwtsn32” and click the [OK] button. 2 Double-click “Windows Firewall”.

3 In the “Dr. Watson for Windows” dialog box, add


the check mark [✓] to “Visual Notification”.

4 Click the [OK] button.


Add the check mark [✓].

Double-click.

3 In the “Windows Firewall” -> “General” tab, select


“Off” and then click the [OK] button.

Select. Click.

98
5.3.11 Disabling Security Center (only in 5.3.12 Time Zone Setting (for each
Windows XP) country)

(This setting is done by executing the batch file.) Set the Time Zone and Date & Time appropriate for
the installation location manually.
1 Select [Start] -> “Run”. Enter ‘Services.msc’ and
[Time Zone]
then click the [OK] button.
Enter “Services.msc”.

Click.

2 Double-click “Security Center”.

[Date & Time]

Double-Click.

3 In the “General” tab, select “Manual” for “Startup


type”, click the [Stop] button and then click the
[Apply], then [OK] button.

Select. Click.

99
5.3.13 LIOS User Registration 4 Set all margins (Left, Right, Top and Bottom) to
“0”.
(This setting is done by executing the batch file.)

1 Register the following user using the same


procedures as “5.2.2 User Registration”.

User Name: LIOS


Password: LIOS
Group: Administrators

5.3.14 Setting IE Page for Receipt Printer

Set to “0”.
(This setting is done by executing the batch file.)

IMPORTANT 5 Close the “Page Setup” dialog box, then close


Before this Setting, connect the receipt printer to the Internet Explorer.

S2, S7 or S9.
(See "2.9 Receipt Printer Setting" in “Frontier
Manager II (S8)” Installation Manual.)

1 Start up Internet Explorer.

2 Select “File” -> “Page Setup” to display the “Page


Setup” dialog box.

Select “File” -> “Page Setup”.

3 Leave the “Header” and “Footer” box blank.

100
5.4 S7 Software Installation

IMPORTANT Before the installation, disconnect the E-DICII (S7) from the LAN. If the installation is done
while the E-DICII (S7) is connected the LAN, an error may occur.

IMPORTANT Make sure to log on with “FRONTIER”.

1 Insert the S7 installer CD into the CD-ROM 3 In the “Starting Installation” dialog box, click the
drive. [Yes] button.

Click the [Yes] button.

R3-318

4 Installation is started up.

2 If the auto-run function of CD is available, the


installer is automatically started up.
If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

101
5 When installation is completed, the completion
message appears. Remove the CD.

R3-358

6 Click the [OK] button. The PC is restarted.

Click.

102
5.5 Optional Software Installation

Install the optional software in addition to those already installed.

IMPORTANT
To install the optional software, the Basic Software must be installed beforehand (See “5.4 S7 Software
Installation”).

This section assumes that the several optional software programs will be installed at one time. When installing
software individually, use the following procedures.

1. Insert the installer CD into the CD drive if the system is started up.
If the system is shut down, insert the installer CD into the CD drive just after starting up the system.
2. Shut down the system through “Post-operational”.
3. Start up the system.
4. In the “Starting Installation” dialog box, click the [Yes] button to start the installation.
5. Remove the installer CD from the CD drive.
6. Click the [Yes] button to restart the system.

5.5.1 Variety Print Software (S3) (CD-ROM Drive)\EZ171\Setup.exe


Installation

Install the Variety Print Software (S3). For the


installation of templates, see the “Variety Print
Software (S3) Instruction Manual”.

[Applicable Basic Software]


Optional S3 software is available for Basic Software 2 In the “Starting Installation (A-010)” dialog box,
S1, S2 and S7. click the [Yes] button.

1 Insert the S3 installer CD into the CD drive of


E-DICII (S7).

When the auto-run function of CD is available,


the installer is started up. Click the [Yes] button.
If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
“Run”.

103
3 Installation is started up. 7 Click the [Yes] button to restart the system.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the


[No] button.

4 Registering information is written into the


registry.

5 Environment settings are done.

6 When the “Setup Complete (A-100)” dialog box,


remove the S3 installer CD from the CD drive of
E-DICII (S7).

104
5.5.2 Tone Selection Software (S4) 4 Registering information is written into the
Installation registry.

Install the Tone Selection Software (S4).

[Applicable Basic Software]


Optional S4 software is available for Basic Software
S1, S2 and S7.

1 Insert the S4 installer CD into the CD drive of


E-DICII (S7).

When the auto-run function of CD is available,


the installer is started up.
If the auto-run function of CD is not available, 5 Environment settings are done.
execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

2 In the “Starting Installation (A-010)” dialog box,

6
click the [Yes] button.
When the “Setup Complete (A-100)” dialog box,
remove the S4 installer CD from the CD drive of
E-DICII (S7).

7 Click the [Yes] button to restart the system.

Click the [Yes] button.

3 Installation is started up.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the


[No] button.

105
5.5.3 Professional Color Correction 3 Installation is started up.
Software (S5) Installation

Install the Professional Color Correction Software


(S5).

[Applicable Basic Software]


Optional S5 software is available for Basic Software
S1, S2 and S7.

1 Insert the S5 installer CD into the CD drive of


E-DICII (S7).

When the auto-run function of CD is available,


the installer is started up.
4 Registering information is written into the
registry.
If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

2 In the “Starting Installation (A-010)” dialog box,


5 Environment settings are done.
click the [Yes] button.

Click the [Yes] button.

6 When the “Setup Complete (A-100)” dialog box,


remove the S5 installer CD from the CD drive of
E-DICII (S7).

106
7 Click the [Yes] button to restart the system. 5.5.4 Frontier Manager II Software (S8)
Installation

Install the Frontier Manager II (S8)/Billing Software


and PLMaker.

After removing the CD, click the [Yes] button


to restart the system.
1 On the “Program Installation Menu” screen,
select “S8 software & Billing software &
To install other software consecutively, click the PLMaker”, then click the [Install] button.
[No] button. Select “S8 software & Billing software & PL-Maker”.

Click the [Install] button.

2 In the “Starting Installation” dialog box, click the


[Yes] button.

Click the [Yes] button.

3 Installation is started up.

107
4 Registering information is written into registry. 5.5.5 Full Automatic Red-eye Correction
Software (S12) Installation

Install the Full Automatic Red-eye Correction


Software (S12).

[Applicable Software]
Optional S12 Software is available for S1, S2, S7
and S9.
For S1, S2 and S7, optional S3 Software must be
installed in advance.

5 Environment settings are done.


1 Insert the S12 installer CD into the CD drive of
E-DICII (S7).

When the auto-run function of CD is available,


the installer is started up.
If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

6 When the “Setup Complete (A-100)” dialog box,


remove the S8 installer CD from the CD drive of
E-DICII (S7).

7 Click the [Yes] button to restart the system. 2 In the “Starting Installation (A-010)” dialog box,
click the [Yes] button.

After removing the CD, click the [Yes] button Click the [Yes] button.
to restart the system.

To install other software consecutively, click the


[No] button.

108
3 Installation is started up. 6 When the “Setup Complete (A-100)” dialog box,
remove the S12 installer CD from the CD drive of
E-DICII (S7).

7 Click the [Yes] button to restart the system.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the

4 Registering information is written into the


[No] button.
registry.

5 Environment settings are done.

109
5.6 After-installation Work

5.6.1 Driver Software Installation 5.6.4 Custom Data Copy Tool

Install the driver software for receipt printer. (See (See 10.2.)
“Frontier Manager (S8) Instruction Manual
[Condition Setup and Maintenance]”).
5.6.5 Media Output Setting

5.6.2 Receipt Printer/Barcode Reader Set up the PC for media output by using the
Setup procedure below.

Set up the following items. (See “2.9 Receipt Printer 1 Insert the S2 installer CD into the CD drive.
Setting” in the “Frontier Manager II (S8) Installation
Manual”.)

(1) Driver software


(2) Barcode reader
(3) Page format on Internet Explorer
(4) Style sheet

5.6.3 Installing the Speaker used for


Indicating Order Completion
R3-318

When performing KIOSK or NET printing, it is


recommended to use the speaker for noticing the
completion of print. Install it and connect it to PC's 2 Select [(99) Special Operations] -> [(9941)
Explorer].
sound output connector.
If the sound board is not installed, install it, then
connect the speaker to it.

Select [(99) Special Operations] -> [(9941) Explorer].

110
3 Execute the following file to set up the PC for 5.6.6 PLMaker Setting
media output.
Set up the PLMaker product information. (See
N:\Tools\OetJobAssignTool\OETASGN.EXE
“Frontier Manager (S8) Instruction Manual

4 The following dialog box appears. [Condition Setup and Maintenance]”).

5.6.7 Media Index Setting

Set up the small and large index for digital service


(for orders from KIOSK, NET and Order Entry
[OES]). Select the service, then add check mark to
5 In the “CD-R Write PC” edit box, enter the name “Small Index” or “Large Index” one by one.
of the PC for media output.

1 Insert the S2 installer CD into the CD drive.


6 Add the check mark [✓] to the “Screen Control
Setting” checkbox, so that WFA is used as Home
Screen.

NOTE:
This checkbox is effective only when S8 is
installed, but displayed even when S8 is not
installed.

7 Click the [OK] button.

R3-318

2 Select [(99) Special Operations] -> [(9941)


Explorer], then execute the following file.
Click.

N:\Tools\MediaIndexSettingTool
\DigitalMediaIndexSetting.exe

3 The following dialog box appears.

111
4 Select the service name in the left-hand list box, 5.6.8 Media Input Environment Setup
then add the check mark [✓] to “Small Index” and (0136)
“Large Index”. (Selecting of any or both of
indexes is available.)
When performing the input from media on the
E-DICII, perform media drive settings for importing
image data.

IMPORTANT
Before this setting, confirm the drive letter of each
media drive by using the Explorer.

1 Select [(01) System Operation Setup and Check]


-> [(0136) Media Input Environment Setup].
Select the service name. Add the check mark [✓].

5 Select the service name and add the check mark


one by one for other as in the Step 4.

6 Click the [Close] button.

Select [(01) System Operation Setup and Check] ->


[(0136) Media Input Environment Setup].

2 Set up the required media drive for input, then


click the [OK] button.

Click.

112
5.6.9 Writing Service Settings (0137) 5.6.10 Photo Copy Configuration (0138)

When performing the CD-R writing on the E-DICII, When performing the photo copy on the E-DICII,
set up the items required for the CD-R writing set up the items required for photo copy printing/
service. writing.

1 Select [(01) System Operation Setup and Check] IMPORTANT


-> [(0137) Writing Service Output Settings]. Before this setting, install the TWAIN driver in the
PC and connect the scanner to the PC.

TWAIN: API (Application Program Interface) and


protocol for image input device.

[Selection]
“Setup and Maintenance” -> [(01) System
Operation Setup and Check] -> [(0138) Photo Copy
Configuration]

[Procedure]
Select [(01) System Operation Setup and Check] ->
[(0137) Writing Service Output Settings]. Set up the flatbed scanner information for photo
copy service (Printing from Print).

2 Set up the items required for CD-R drive, CD-


ROM drive and media drives and then click the
[OK] button.

Click.

113
1 Select the model name of the connected 5.6.11 Index Conditions (0227)
scanner in the [Device Name] list.
[Selection]
“Setup and Maintenance” -> [(02) Print Condition
Setup and Check] -> [(0227) Index Conditions]

[Procedure]
Select the condition of the index printing and large
index printing.

2 Select the scanner source name (logical device


name) in the [TWAIN Source] list.

<Media>

1 Click the [▼] button in the box to be changed and


select the logo.

3 Click the [OK] button.

• Operation returns to the menu screen.

Logo: FUJICOLOR*INDEX PRINT


FUJICOLOR INDEX PRINT
INDEX PRINT
Index Custom Logo:
Can be registered on Menu 1020.

2 Click the [OK] button.

• Operation returns to the menu screen.

114
<Index for Media> 5.6.13 Equipment Name Set (0124)

1 Click the “Index for Media” tab. [Selection]


“Setup and Maintenance” -> [(01) System
Operation Setup and Check] -> [(0124) Equipment
Name Set]

[Procedure]
Set up the device name to be used in the system
and its identifier when creating an order.

1 Set up the following items.

- Device Name: Unique Device Name for


Imaging Controller

2
- Order Identifier: Unique lower-case alphabet
Click the [▼] button in the box to be changed and
(This is added to the order No.)
select the logo.

Logo: FUJICOLOR*INDEX PRINT


FUJICOLOR INDEX PRINT
INDEX PRINT
Index Custom Logo:
Can be registered on Menu 1020.

3 Click the [OK] button.

• Operation returns to the menu screen.

5.6.12 Print Condition Setup 2 Click the [OK] button.

• Operation returns to the menu screen.


Perform the “Print Condition Setup and Check”
menus other than menus 0227 and 0201.

5.6.14 Shop Logo Regist/Delete (1020)

1 Select the [(10) Register/Delete] -> [(1020) Shop


Logo Regist/Delete] button.

2 Setup the shop logo. For settings, see the S7


Instruction Manual (Condition Setup and
Maintenance).

Note that the same shop logo must be set up for


S2 and S1.

115
5.6.15 Remote Desktop Settings (only in 3 In the “License Agreement” screen, select
use of FMPC in the Earlier-type “I accept...” and then click the [Next] button.
System)

To switch the screen display between FMPCII and


E-DICII, the Remote Desktop Client must be
installed.

IMPORTANT
When using S2 on the Windows XP, it is not
necessary to install the following Remote Desktop
Client. In this case, start the operation from
“Remote Desktop Setting” shown on page 117.
Select. Click the [Next] button.

[Installing Remote Desktop Client]


4 Enter the following information and then click the
[Next] button.

1
(1) User Name: Enter ‘FRONTIER’.
Open the “Driver” -> “RemoteDesktop” folder in
(2) Organization: Leave this box blank.
the S7 installer disk and then double-click the
(3) Install this application for: Select “Only for me”.
“msrdpcli” icon.
Enter ‘FRONTIER’. Leave this box blank.

2 “InstallShield Wizard” appears. Click the [Next]


button.

Select “Only for me”. Click the [Next] button.

Click the [Next] button.


5 Click the [Install] button to start installation.

Click the [Install] button.

116
6 Installation is started. 3 The following dialog box appears. Copy
‘FRONTIER’ in the “User name” box and paste it
in the “Password” box.
Copy ‘FRONTIER’.

7 When installation is completed, the following


dialog box appears. Click the [Finish] button.

Paste it.

4 Check [✓] the “Save my password” check box


and then click the [Save As] button.

Click the [Finish] button.

[Remote Desktop Setting]

Perform the settings for switching the screen


between S2 and FMPCII.

1 Insert S2 installer CD Software into the CD-ROM


drive to execute “AfterConfig.bat” in
“N:\Tools\OSAutoConfig”.

2 “FMPCNameSetTool” dialog box appears in a


command prompt screen. Enter the name of the
FMPC to be connected and then click the [OK]
button. Check [✓]. Click the [Save AS] button.

117
5 The following dialog box appears. Click the 5.6.16 Setting the HELP
[Save] button to overwrite the file.
See “3.7.20 Setting the HELP” on page 66.

Click the [Save] button.

6 Operation returns to the following dialog box.


Click the [Cancel] button and then restart the
system.

Click the [Cancel] button.

118
6 FMPCII (S9) Installation

6.1 FMPCII (S9) Installation Outlines

6.1.1 Installation Procedure

FMPCII (S9) Installation Procedure

6.2 Setting IEEE1394 Driver

6.3 Disconnecting PU800B

6.4 BIOS Setting and User Registration

6.5 Windows Settings

6.6 S9 Software Installation

6.7 Optional Software Installation

6.8 After-installation Work

119
6.1.2 Preliminary Work for S9-use Hardware

Before installing S9 (FMPCII Basic Software), the following preliminary work for FMPCII hardware is required.

BIOS Hyper-threading OFF (See 6.4.1)


OS Windows XP Pro. SP2
HDD FD: “A:” drive
CD-ROM: “N:” drive
Total Disk Space: (“C:” and “D:” drives)
80GB: (20GB, 60GB)
160GB: (20GB, 140GB)
“C:” and “D:” drives: NTFS format
User Registration Register the following data. (See 6.4.2)
User Name: FRONTIER
Password: FRONTIER
Group: Administrators
Windows Settings No. [Shaded items can be installed in the one action of executing the batch file.]
[1] Disabling Windows XP Style (See 6.5.2)
[2] [Date and Time Settings] In “Regional and Language Options”, set the date setting
to “dddd, MMMM, dd, yyyy” and time setting to “24-hour format”. (See 6.5.3)
[3] System Error Setting (See 6.5.4)
[4] -
[5] Disabling User Assistant Function (See 6.5.5)
[6] Hide Setting of Screen Keyboard Dialog Box (See 6.5.6)
[7] Disabling Error Reporting (See 6.5.7)
[8] Auto-hide Setting for Task Bar (See 6.5.8)
[9] “Visual Notification” to ON in Dr. Watson Dialog Box (See 6.5.9)
[10] Disabling Windows Firewall (See 6.5.10)
[11] Disabling Security Center (See 6.5.11)
[12] Inhibition of IE Dialog Display for Web maintenance display (See 6.5.12)
[13] Time Zone Setting for each country (See 6.5.13)
[14] Remote Desktop Setting (See 6.5.14)
[15] -
[16] Setting IE page for Receipt Printer (See 6.5.15)
Computer Name FE-FMPC
IP Address 192.168.1.20
Default gateway 192.168.1.14
DNS primary address 192.168.1.14
Subnet mask 255.255.255.224
Workgroup WORKGROUP
IEEE1394 Driver Setting -

Computer Name, IP Address, etc.:


Set the computer name, IP address, etc. according to the system environment. If acceptable, set the above
values.

IMPORTANT Do not install the “NetBEUI” protocol.

120
6.2 Setting IEEE1394 Driver

■ Precautions for Setting IEEE1394 Driver 2) Lift up the board stopper while pressing the
hook.
[1] Log in to the system using an Administrator Board Stopper
account.
[2] Be sure to connect the IEEE1394 interface
cable and turn ON the power. Otherwise
installation cannot be executed.
[3] This driver disk is only for FMPCII (hereafter
described as “FMP Controller”) and not
applicable to other devices.
[4] When the FMP Controller, conventional SP and
LP1500/LP2000 are connected, connect the
IEEE1394 interface cable between LP1500/
NMP006i
LP2000 and FMP Controller to the upper side of
the IEEE1394 board and connect the IEEE1394
interface cable between the conventional SP 3) Remove one of the boards from the slot.
and FMP Controller to the lower side of the
IEEE1394 board.

6.2.1 When Connecting FMP Controller,


SP-3000, LP-5500/LP-5700/LP-5900

If the two 1394 boards are installed in the PC,


use the following procedures to remove one of
NMP006r
them.

4) Close the board stopper.


1 Remove one of the two 1394 boards from the SP
(Example). 5) Close the upper cover.

Upper Cover
1) While pressing the two buttons on each side,
open the upper cover slowly.

Upper Cover

NMP007

Buttons (2) NMP001

121
2 When both the FMP Controller and driver disk 5 While restarting Windows, when other devices
are not installed, the “Found New Hardware are connected, “Found New Hardware Wizard”
Wizard” dialog box appears after Windows starts appears. Click the [Next] button.
up. Here, click the [Cancel] button (Note1) to
cancel device driver installation. Two kinds of the
“Found New Hardware Wizard” dialog boxes may
appear depending on the device connection
status. If this occurs, click the [Cancel] button for
both dialog boxes.

Note 1: Ignore this dialog box. (Ignoring this dialog


box does cause any problem.)

Click.

6 The “Completing the Found New Hardware


Wizard” dialog box appears. Click the [Finish]
button. Installation of the printer/processor driver
is now completed.

Click.

3 Insert the drive disk into the CD-ROM drive. And


in the displayed dialog box, click the [OK] button
to perform device driver settings.

Click.

7 In the completion message, click the [Cancel]


Click. button, then perform the following operation.

4 When device driver settings are completed, the 1) Select [START] -> “Control Panel” and click
following dialog box appears. Remove the driver “Network Connection”.
disk from the CD-ROM and then click the [OK]
button. Windows is restarted.

Click.

122
2) Right-click on “1394 Connection” to display 6.2.2 When Connecting FMP Controller,
the “Internet Protocol (TCP/IP) Properties” SP-3000 and LP1500/LP2000
screen.

1 Shut down the system, then connect the SP and


LP to the FMP Controller.

If the two 1394 boards are installed in the PC,


remove one of them while referring to "6.2.1".

In case of DELL® GX280, make sure that the


LAN cable from scanner (SP) is connected to the
LAN port and the cable from printer (LP) to the
upper board.
Select “1394 Connection” and
display the property screen. Scanner (SP) Printer (LP)

3) Change the setting from “Obtain an IP


LAN
address automatically” to “Use the following Cable
IP address”, and then enter the following IP
address and a subnet mask values.

IP address 192.168.0.10 FMPC


Subnet mask 255.255.255.0

IEEE1394
Cable

2 When both the FMP Controller and driver disk


are not installed, the “Found New Hardware
Wizard” dialog box appears after Windows starts
up. At this time, click the [Cancel] button (Note1)
to cancel device driver installation. Two kinds of
the “Found New Hardware Wizard” dialog boxes
may appear depending on the device connection
status. If this occurs, click the [Cancel] button for
all dialog boxes.

Note 1: Ignore this dialog box. (Ignoring this dialog


box does not cause any problem.)

4) Click the [OK] button.

Click.

123
3 Insert the drive disk into the CD-ROM drive. In 6 The “Completing the Found New Hardware
the displayed dialog box, click the [OK] button to Wizard” dialog box appears. Click the [Finish]
perform device driver settings. button. Installation of the printer/processor driver
is now completed.

Click.

4 When device driver settings are completed, the


following dialog box appears. Remove the driver
disk from the CD-ROM and then click the [OK]
Click.
button. Windows is restarted

7 Installation of 1394 client driver for the scanner


and printer/processor is now completed.

8 Also for the conventional SP, perform Steps 5 to


6.

Click.
9 Select [Start] -> “Control Panel”. Click “Network
and Internet Connections”. In the displayed
5 While restarting Windows, when other devices dialog box, right-click the “1394 Connection” icon
are connected, “Found New Hardware Wizard” and then select “Disable”.
appears. Click the [Next] button.

Right-click. Select.

Click.

124
6.2.3 When Connecting FMP Controller to 3 Insert the drive disk into the CD-ROM drive. In
SP1500/2000 and LP1500/LP2000 the displayed dialog box, click the [OK] button to
perform device driver settings.

1 Shut down the system, then connect the SP and


LP to the FMP Controller.

In case of DELL® GX280, make sure that the


IEEE 1394 cable from scanner (SP) is
connected to the lower board, and the cable from
printer (LP) to the upper board.

Scanner (SP) Printer (LP)


Click.

4 When device driver settings are completed, the


following dialog box appears. Remove the driver
disk from the CD-ROM and then click the [OK]
button. Windows is restarted.
FMPC

IEEE1394
Cable

IEEE1394
Cable
Click.

2 When both the FMP Controller and driver disk


5 While restarting Windows, when other devices
are not installed, the “Found New Hardware
are connected, “Found New Hardware Wizard”
Wizard” dialog box appears after Windows starts
appears. Click the [Next] button.
up. At this time, click the [Cancel] button (Note1)
to cancel device driver installation. Two kinds of
the “Found New Hardware Wizard” dialog boxes
may appear depending on the device connection
status. If this occurs, click the [Cancel] button for
all dialog boxes.

Note 1: Ignore this dialog box. (Ignoring this dialog


box does not cause any problem.)

Click.

Click.

125
6 The “Completing the Found New Hardware 6.2.4 When Connecting FMP Controller to
Wizard” dialog box appears. Click the [Finish] SP1500/2000 and LP5000 Series
button. Installation of the printer/processor driver
is now completed.
1 Shut down the system, then connect the SP and
LP to the FMP Controller.

In case of DELL® GX280, make sure that the


IEEE 1394 cable from scanner (SP) is
connected to the lower board, and the cable from
printer (LP) to the upper board.

Scanner (SP) Printer (LP)

Click.
FMPC

7 Installation of 1394 client driver for the scanner


and printer/processor is now completed.
IEEE1394
Cable
8 Also for the conventional SP, perform Steps 5 to
6.
IEEE1394

9
Cable
Select [Start] -> “Control Panel”. Click “Network
and Internet Connections”. In the displayed
dialog box, right-click the “1394 Connection” icon 2 When both the FMP Controller and driver disk
are not installed, the “Found New Hardware
and then select “Disable”.
Wizard” dialog box appears after Windows starts
up. At this time, click the [Cancel] button (Note1)
to cancel device driver installation. Two kinds of
the “Found New Hardware Wizard” dialog boxes
may appear depending on the device connection
status. If this occurs, click the [Cancel] button for
all dialog boxes.

Note 1: Ignore this dialog box. (Ignoring this dialog


box does not cause any problem.)

Right-click. Select.

Also disable another “1394 Connection”.

Click.

126
3 Insert the drive disk into the CD-ROM drive. In 6 The “Completing the Found New Hardware
the displayed dialog box, click the [OK] button to Wizard” dialog box appears. Click the [Finish]
perform device driver settings. button. Installation of the printer/processor driver
is now completed.

Click.

4 When device driver settings are completed, the


following dialog box appears. Remove the driver
disk from the CD-ROM and then click the [OK]
Click.
button. Windows is restarted.

7 In the completion message, click the [Cancel]


button, then perform the following operation.

1) Select [START] -> “Control Panel” and click


“Network Connection”.

Click.
2) Right-click on “1394 Connection 2” to display
the “Internet Protocol (TCP/IP) Properties”
5 While restarting Windows, when other devices screen.
are connected, “Found New Hardware Wizard”
appears. Click the [Next] button.

Select “1394 Connection 2” and


display the property screen.

Click.

127
3) Change the setting from “Obtain an IP 9 Select [Start] -> “Control Panel”, then click the
address automatically” to “Use the following “Network Connections”.
IP address”, and then enter the following IP
address and a subnet mask values. IMPORTANT
Check the settings are done as follows:
IP address 192.168.0.10 1394 Connection on SP: Disabled
Subnet mask 255.255.255.0 1394 Connection on LP: Enabled

10 Right-click on the “1394 Connection” whose


status is “Enabled”, then set it to “Disabled”.

Right-click. Select.

11 Connect the IEEE1394 cable (for connecting to


the LP) to the FMPC again.

12 Shut down the FMPC from [Start] -> “Shut


4) Click the [OK] button. Down...”.

8 Disconnect the IEEE1394 cable (for connecting


to LP) from the FMPC.

128
6.2.5 DICII, FMPCII and LP5000 Series (no SP) Configuration

Perform the same procedures as “6.2.1 When Connecting FMP Controller, SP-3000, LP-5500/LP-5700/LP-
5900”.

6.2.6 Error Message

If an error occurs after clicking the [OK] button in the procedure (6.2.1)-[Step2], (6.2.2)-[Step2], (6.2.3)-[Step2]
or (6.2.4)-[Step2], an error message appears. If this occurs, click the [OK] button in the error dialog box. After
Windows is restarted, continue the installation procedures after [Step2].

6.3 Disconnecting PU800B

When the PU800B is used with the FRONTIER, disconnect it.

129
6.4 BIOS Setting and User Registration

6.4.1 Hyper-threading Setup 6.4.2 User Registration on

The following procedures are examples. They way Register the following user name and password.
vary depending on the PC.

USER NAME: FRONTIER


1 Start up the FMPC, then press the [F2] key just
PASSWORD: FRONTIER
when “Strike F1 to retry boot, F2 for setup utility”
GROUP: Administrators
appears.

2 Open “Performance” -> “Hyper-threading”, then


The following procedures are one example when
set “Hyper-threading” to “Off”.
using the Wizard in the Windows XP.

1 On the Desktop, select [Start] -> “Control Panel”


-> “User Accounts”, then on the “User Accounts”
screen, click “Create a new account”.

3 Exit the BIOS screen while saving the settings.

IMPORTANT
If [Hyper-threading] is changed to “On”, the
Windows must be installed again.

2 Enter ‘FRONTIER’ and then click the [Next]


button.

130
3 Select “Computer administrator”, then click the 6 Enter ‘FRONTIER’ both in the “Type a new
[Create Account] button. password” and “Type the new password again...”,
then click the [Create Password] button.

4 On the “User Accounts” screen, click the


“FRONTIER” icon. 7 Close the opened screen with [X] button, then on
the “Control Panel” screen, click “Switch to
Classic View”.

5 Click the “Create a password”.

8 Click the [User Account] button.

131
9 Click “Change the way users log on or off”.

10 On the “Select logon and logoff options” screen,


remove the check mark [✓] from “Use the
Welcome screen”, then click the [Apply options]
button.

11 Click the [X] buttons to close all opened screens.

12 Restart the PC.

132
6.5 Windows Settings

6.5.1 Settings Completed with Batch 6.5.2 Disabling Windows XP Style


File
Set the following item manually by performing Step
For the items marked with the description (This 1 to 5.
setting is done by executing the batch file.), all
required settings are performed in the one action of
executing the batch file. Insert Basic Software CD-
1 Right-click on any part of Desktop and the select
[Properties].
ROM into the CD-ROM drive and execute the
“BeforeConfig.bat” file in the “N:\Tools\OSAutoConfig”
folder by selecting [Start] -> “Run” on the Desktop.
2 In the “Theme” tab in the “Display Properties”
screen, select “Windows Classic” for “Theme”
(Ex: “N:” drive.) After executing a batch file, restart the and then click the [OK] button.
system and perform the settings for other items.

After the batch file is executed, set up the items


without shade in 3.2, 3.3, 3.4 manually. These
items cannot be set through the batch file.

Select. Click.

3 Select [Start] -> “Run”. In the “Run” dialog box,


enter ‘Services.msc’ and then click the [OK]
button.
Enter ‘Services.msc’.

Click.

133
4 On the “Services” screen, double-click 6.5.3 [Date and Time Settings] Regional
“Themes”. and Language Settings

(This setting is done by executing the batch file.)

In “Regional and Language Options”, set the date


setting to “dddd, MMMM, dd, yyyy” and time setting
to “24-hour format”.

IMPORTANT
Make sure that the time is correctly adjusted.

Double-Click.

5 On the “Themes Properties” screen, select


“Disabled” for “Startup type”, click the [Stop] 6.5.4 System Error Setting
button and then click the [Apply] -> [OK] button.

(This setting is done by executing the batch file.)

1 Select [Start] -> “Control Panel” -> “System”. In


the “System Properties” screen, click the
“Advanced” tab. Click the [Settings] button in the
“Startup and Recovery” column and then
perform the settings as shown below.

Select.

The above is the example of Windows XP.

- [ ✓]: Write an event to the system log


- [ ✓]: Send an administrative alert
- [ ]: Automatically restart
- [ ✓]: Overwrite any existing file

134
6.5.5 Disabling User Assistant Function 6.5.7 Disabling Error Reporting

(This setting is done by executing the batch file.) (This setting is done by executing the batch file.)

1 Select [Start] -> “Control Panel” -> “Accessibility 1 Open “Control Panel”.
Options” and then remove all check marks [✓] (to
disable all user assistant functions). 2 Double-click “System”.

Double-click.

3 In the “System Properties” screen, click the


“Advanced” tab and then click the [Error
Reporting] button.
Click.

6.5.6 Hide Setting of Screen Keyboard


Dialog Box

Set the following item manually by performing the


following step.

1 Select [Start] -> “All Programs” -> “Accessories”


-> “Accessibility” -> “On-screen Keyboard”.
Check “Do not show this message again”.

Click.

Check.

135
4 Select “Disable error reporting”, remove the 6.5.8 Auto-hide Setting for Task Bar
check mark [✓] from “But notify me...” and then
click the [OK] button. (The setting is done by executing the batch file.)
Select.

1 On the Desktop, select [Start] -> “Settings” ->


“Taskbar & Start Menu”.

Remove the check mark [✓]. Click.

Select [Start] -> “Settings” -> “Taskbar & Start Menu”.

2 Remove the check mark [✓] from “Keep the


taskbar on top of other windows” and add the
check mark [✓] to “Auto-hide the taskbar”, then
click [Apply] -> [OK].
Remove the check mark [✓].
Add the check mark also [✓].

136
6.5.9 “Visual Notification” to ON in Dr. 6.5.10 Disabling Windows Firewall
Watson Dialog Box
(This setting is done by executing the batch file.)
(This setting is done by executing the batch file.)
1 Open “Control Panel”.
1 Select [Start] -> “Run”.
2 Double-click “Windows Firewall”.
2 Enter “drwtsn32” and click the [OK] button.

3 In the “Dr. Watson for Windows” dialog box, add


the check mark [✓] to “Visual Notification”.

4 Click the [OK] button.


Add the check mark [✓].

Double-click.

3 In the “Windows Firewall” -> “General” tab, select


“Off” and then click the [OK] button.

Select. Click.

137
6.5.11 Disabling Security Center 6.5.12 Inhibition of IE Dialog Display (for
Web maintenance display)
(This setting is done by executing the batch file.)
(This setting is done by executing the batch file.)
1 Select [Start] -> “Run”. Enter ‘Services.msc’ and
then click the [OK] button. 1 Open “Control Panel”.
Enter “Services.msc”.
2 Double-click “Internet Options”.

Click.

2 Double-click “Security Center”.

Double-click.

3 In the “Security” tab, click the [Custom Level...]


button.

Double-Click.

3 In the “General” tab, select “Manual” for “Startup


type”, click the [Stop] button and then click the
[Apply], then [OK] button.

Click.

Select. Click.

138
4 Select “Enable” for “Miscellaneous” -> “Submit 6.5.14 Remote Desktop Setting
nonencrypted form data”.
(This setting is done by executing the batch file.)

1 Right-click “My Computer” and then select


“Properties”.

Select.

5 Click the [OK] button.

6.5.13 Time Zone Setting (for each Right-click. Select.


country)

Set the Time Zone and Date & Time appropriate for 2 In the “System Properties” dialog box, click the
the installation location manually. “Remote” tab.

[Time Zone]

[Date & Time]

Check.

3 Add the check mark (✓) to “Allow users to


connect remotely to this computer”.

4 Click the [Apply], then [OK] button to close the


“System Properties” dialog box.

139
6.5.15 Setting IE Page for Receipt Printer 4 Set all margins (Left, Right, Top and Bottom) to
“0”.
(This setting is done by executing the batch file.)

IMPORTANT
Before this Setting, connect the receipt printer to
S2, S7 or S9.
(See “2.9 Receipt Printer Setting” in “Frontier
Manager II (S8)” Installation Manual.)

1 Start up Internet Explorer.

2 Select “File” -> “Page Setup” to display the “Page


Setup” dialog box.

Set to “0”.

5 Close the “Page Setup” dialog box, then close


the Internet Explorer.

Select “File” -> “Page Setup”.

3 Leave the “Header” and “Footer” box blank.

140
6.6 S9 Software Installation

This section explains how to install S9 Basic Software (FMPCII Software).


Types of installation are as follows.

Perform the installation by using any of the following “Installation” patterns.

- Upgrading from the current FMPCI to FMPCII


(Printer/processor data are inherited through the backup FD for FMPCI.)
- New installation (for a new system)
(*1)
(Use the printer/processor backup FD attached to the printer/processor.)
- New installation (for the current system)
(*2)
(Printer/processor data are inherited through the backup FD for FMPCI.Printer/processor data must be
saved in a former state.)

(*1) In case of a system using the SP-3000, DICII and FMPCII, all programs are newly installed.
(*2) In case of a system using the SP-3000 and DICII, only FMPCII program is added to the existing
programs.

When the current FMPCI is upgraded to FMPCII, the printer/processor backup FD must be created before
installation.

When the S9 installer is started up, the dialog box for selecting [New Installation] or [Re-installation] appears.
Select [Reinstallation].

During reinstallation, the following operations are executed.


- Software installation into the PC for FMPC and printer/processor
- Parameter restoration using the backup FD

(1) Preparation for Reinstallation


Before executing reinstallation, check the following points.
1) Check of ROM version for LP1500SC/LP2000SC
When the LP1500SC/2000SC is connected, check that the version of LP1500SC/LP2000SC in the
operation panel is “7.7 X-nnn or later”.
When the version of LP1500SC/2000SC is “7.6-0 X-nnn” or earlier, upgrade the LP1500SC/LP2000SC by
exchanging the ROM.

141
2) Backup FD
The printer/processor backup FD are used.
Make sure this backup FDs is available. (If the printer/processor backup FD is not used, each parameter
needs to be set again.)
- Printer/Processor Backup FD
Note that the backup FD for “LP1500SC/LP2000SC” and that for “LP-5500/LP-5700/LP-5900” are
different. Make sure to use the appropriate backup FD.

(2) Reinstallation Procedure


IMPORTANT Before the installation, disconnect the FMPCII (S9) from the LAN. If the installation is done
while it is connected the LAN, an error may occur.

IMPORTANT Make sure to log on with “FRONTIER”.

1 When the PC for S9 is started up, insert the S9 3 The printer/processor selection dialog box
installer CD into the CD-ROM drive. When the appears. Select the appropriate printer/
auto-run function of CD is effective, the installer processor.
is started up. Select the appropriate printer.
If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
“Run”.

(CD-ROM Drive)\EZ171\Setup.exe

Click.

2 When the S9 installer starts up, select “Re- 4 In the “C-045” dialog box, click the [OK] button.
installation”. And in the dialog box for starting
installation, select “Yes”.

Click.

5 In the “C-058” dialog box, click the [Yes] button.

Select. Click.

142
6 In the “C-060” dialog box, click the [No] button. 10 Click the [OK] button.

Click. Click.

7 In the “C-070” dialog box, click the [Yes] button.


11 Remove the backup FD from the FD drive.

Click.

8 Insert the backup FD into the FD drive.

NMP015

12 Select [Start] -> “Shutdown” to restart the


system.

NMP014

9 When installation is completed, the completion


message appears. Remove the CD from the CD
drive.

NMP013

143
6.7 Optional Software Installation

Install the optional software in addition to those already installed.

This section assumes that the several optional software programs will be installed at one time. When installing
software individually, use the following procedures.

1. Insert the installer CD into the CD drive if the system is started up.
If the system is shut down, insert the installer CD into the CD drive just after starting up the system.
2. Shut down the system through “Post-operational”.
3. Start up the system.
4. In the “Starting Installation” dialog box, click the [Yes] button to start the installation.
5. Remove the installer CD from the CD drive.
6. Click the [Yes] button to restart the system.

6.7.1 Frontier Manager II Software (S8) 3 Installation is started up.


Installation

Install the Frontier Manager II (S8)/Billing Software


and PLMaker.

1 On the “Program Installation Menu” screen,


select “S8 software & Billing software &
PLMaker”, then click the [Install] button.
Select “S8 software & Billing software & PL-Maker”.

4 Registering information is written into registry.

Click the [Install] button.

2 In the “Starting Installation” dialog box, click the


[Yes] button.

Click the [Yes] button.

144
5 Environment settings are done. 6.7.2 Full Automatic Red-eye Correction
Software (S12) Installation

Install the Full Automatic Red-eye Correction


Software (S12).

[Applicable Software]
Optional S12 Software is available for S1, S2, S7
and S9.

1 Insert the S12 installer CD into the CD drive of


FMPCII (S9).

6 When the “Setup Complete (A-100)” dialog box, When the auto-run function of CD is available,
remove the S8 installer CD from the CD drive of the installer is started up.
DICII. If the auto-run function of CD is not available,
execute the following file by selecting [Start] ->
7 Click the [Yes] button to restart the system. “Run”.

(CD-ROM Drive)\EZ171\Setup.exe

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the


[No] button.

2 In the “Starting Installation (A-010)” dialog box,


click the [Yes] button.

Click the [Yes] button.

145
3 Installation is started up. 6 When the “Setup Complete (A-100)” dialog box,
remove the S12 installer CD from the CD drive of
FMPCII (S9).

7 Click the [Yes] button to restart the system.

After removing the CD, click the [Yes] button


to restart the system.

To install other software consecutively, click the

4 Registering information is written into the


[No] button.
registry.

5 Environment settings are done.

146
6.8 After-installation Work

6.8.1 Media Output Setting 4 The following dialog box appears.

When using E-DICII (S7), the setting for media


output is required.

Set up the PC for media output by following the


procedure below.

1 Insert the S7 installer CD into the CD drive.

5 In the [CD-R Write PC] edit box, enter the name


of the PC for media output.

6 Add the check mark [✓] to the [Screen Control


Setting] checkbox, so that WFA is used as Home
Screen.

NOTE:
This checkbox is effective only when S8 is
installed, but displayed even when S8 is not
installed.

7 Click the [OK] button.

R3-318

2 Select [(99) Special Operations] -> [(9941)


Explorer].

Click.

8 Remove the installer CD from the CD drive.

Select [(99) Special Operations] -> [(9941) Explorer].

3 Execute the following file to set up the PC for


media output.

N:\Tools\OetJobAssignTool\OETASGN.EXE
R3-358

147
6.8.2 Installation Information Setup 6.8.3 Print Size Setup (0220)
(0140)
Set up the print size.
In the case of a new installation, perform the setting
for connecting to the printer/processor. Select [(02) Print Condition Setup and Check] ->
In the case of reinstallation or version upgrading, [(0220) Print Size Setup], then setup the desired
this setting is not required. print size.

1 Select [(01) System Operation Setup and Check]


-> [(0140) Installation Information Setup].

Select [(01) System Operation Setup and Check] ->


[(0140) Installation Information Setup].

2 In the “Printer” column, select the printer/


processor to be connected.

148
6.8.4 1394 Connection Check (0145) 6.8.5 Copying Print Sizes from FMPC
(only in use of earlier system (S9) to FD
(FMPC))
Copying Print Size Copy Tool (PrintsizeSnc.exe)
Perform this setting before connecting to the to FD
existing system.
Perform this operation on S9 PC.
When FMPCII is connected to a conventional SP
(FRONTIER 350/370), perform the setting for 1394 1 Insert the S9 CD into the CD drive of the FMPCII
(S9).
connection by following the procedure below.

2 Insert the blank FD into the FD drive.


1 Select [(01) System Operation Setup and Check]
-> [(0145) 1394 Connection Check].

NMP014

3 Execute “Tool” -> “PrintSize Tool” -> “Print


Select [(01) System Operation Setup and Check] -> SizeTool.bat” in the CD drive by selecting [Start]
[(0145) 1394 Connection Check]. -> “Run”.

2 Select “Connect” for “SP (scanner) Type” and


then click the [OK] button.
Select [Connect].

4 The print size copy Tool (PrintsizeSnc.exe) is


copied to the FD.

Click.

149
5 Remove the FD from the FD drive. 6.8.6 Setting the HELP

See “3.7.20 Setting the HELP” on page 66.

NMP015

6 Remove the CD from the CD drive.

NMP013

150
7 S2 (Client) Installation for Earlier-type FRONTIER

7.1 S2 (Client) Installation Procedure

This section explains how to install S2-A1 Connection Software for SP1500/2000, SLP-800SC and
SLP-1000SE.

S2-A1 Connection Software needs to be installed 3 The following dialog box appears. Enter the
only when any of the following system software name of the DICII and FMPCII and then click the
versions are used. [Next] button.

Available Versions
Model System Software Version
SP1500/2000 Ver.7.6/Ver.7.7
SLP-800SC Ver.4.0
SLP-1000SE Ver.4.0

IMPORTANT
Before installing the software, disconnect the
SP1500/SP2000/SLP-800SC/SLP-1000SE from
the LAN. If the installation is done while the
Make sure to enter the name of the DICII.
SP1500/SP2000/SLP-800SC/SLP-1000SE is
It is necessary to enter the name of the FMPCII
connected to the LAN, an error may occur.
only when it is connected. If it is not used, leave

1
the [FMPCII] box blank.
Insert the S2 installer CD into the CD-ROM drive
of the conventional FRONTIER and then restart
the system.
4 When installation is completed, the completion
message appears. Remove the CD and then
click the [OK] button. In the case of SP1500/
2000, the system is restarted. In the case of
SLP-800SC/SLP-1000SE, the system is shut
down.

MP026

2 When the installer dialog box appears, select MP027


[Yes].

151
7.2 After-installation Work

7.2.1 Installation Information Setup In case of FRONTIER 330/340, the same


function is provided on the “[0140] Installation
Set the external file I/O to ON to communicate with Information Setup” screen.
the Imaging Controller.

■ ON the FRONTIER 330/340/350/370/390

1 On the “Main Menu” screen, select [Setup and


Maintenance] and click [OK].

Click.

4 Click [Option].

2 In the “Log-in” dialog box, select “SE2”, then


enter the password ‘7777’ and click the [OK]
button.
Select “SE2”.

Click.

5 On the “Optional Device Setting” screen, set


“External File I/O” to “YES”, then click [OK].
Click “YES”.

Click.

3 Select [41 System Operation Setup and Check] -


[41F Installation Information Setup] and click
[START] in case of FRONTIER 350/370.

Click.

152
8 Connections and Start-up

8.1 FE System Connection Diagram

Connect the SP (S1), DICII (S2), E-DICII (S7) and FMPCII (S9) by using the LAN cables with HUB
as shown in the following figure.

Scanner (SP-3000)

FMPCII
■ System Software ■ System Software
FRONTIER System Basic Frontier Manager Printer Controller II
Software (S1) Software (S9)

LAN Cable
LAN Cable
HUB
IEEE 1394
Cable

LAN Cable LAN Cable

LP1500SC/2000SC
E-DICII DICII
■ System Software ■ System Software
Imaging Controller System Imaging Controller System
Basic Software (S7) Basic Software (S2)

or

LP-5500/5700/5900

FEC02

153
8.2 Starting Up the System

Start up the system in the following order.

1 Make sure that the printer (LP) is started up. • The DICII (S2) main menu screen appears.

2 Start up the DICII (S2)

4 Make sure that the DICII (S2) main menu is


displayed, then start up the FMPCII (S9).
DICII-001

3 Make sure that the DICII (S2) main menu is


displayed, then start up the E-DICII (S7).

NMP010

5 Make sure that the DICII (S2) main menu is


displayed, then start up the SP (S1).

DICII-001

ZII040

154
9 Application Environment Settings

Before starting the works, make sure all devices (PCs) are connected via LAN.

9.1 S2 Settings

9.1.1 Setup and Maintenance 3 In the confirmation message, click the [Initial]
button.
Perform the following settings on the “Setup and
Maintenance” menu.

- System Operation Setup and Check (0921)

(1) System Operation Setting Setup (0921)

Perform the settings for system operation menu


(0129). Click.

1 Select “Setup and Maintenance” -> [(09) System


Operation Setup and Check] -> [(0921) System
Operation Setting Setup].

2 On the “System Operation Setting Setup [0921]”


screen, click the [Initialization] button.
Click.

155
4 Perform the other settings on this screen.

1
2
3
7

8
5 9

6
12

13

10 11 14

No. Item Description


1 Complete Order Retention Period Set up the period for storing the order information.
Range: 0 to 99

2 Order Image File Retention Period Set up the period for storing the order image file.
Range: 0 to 99
This value must be within the [Complete Order Retention
Setup] (1).
3 Product Info Retention Period Set up the period for storing the product information.
Range: 0 to 99

4 Print Size Setup Displays the “Print Size Setup” screen, where you can select the
print sizes and those used in the FRONTER, and then relate
them.

(See “4.1.1 Setting the Print Size” in the S2 Instruction Manual


[Condition Setup and Maintenance].)

156
No. Item Description
5 Inspection Setting Switches the inspection work in the system between [Auto] and
[Manual]. If Auto is selected, the operations from inspection to
defining of the quantity of products are performed automatically.

6 Billing Setting Selects if the billing is performed or not. If [Yes] is selected, the
system enters into the waiting for billing status after the process is
completed.

7 Maintenance-Initialization Initializes all system configuration information after the


confirmation dialog box appears.

This action is available only when no job is currently processed in


the system. (Message may appear).
8 Period to Delete Order Set up the period for deleting the orders forcibly. They are deleted
starting from the oldest after the specified period has passed.
Range: 1 to 99
This value must be within the [Complete Order Retention
Setup] (1).
9 Delete Executes the deletion of the order including the image files along
with the value set in the [Period for Force Deletion] (10).

157
No. Item Description
10 Price Setup-Read Obtain the product/price information from the data base files. The
file selection dialog box appears.
Default Directory: Desktop

11 Price Setup-Write Write the product/price information to the data base files. The
folder selection dialog box appears.
Default Directory: Desktop

12 Service Time Setting Displays the “Service Time Setting” screen.

(See “4.1.2 Setting the Service Time” in the Instruction Manual


[Condition Setup and Maintenance].)
13 Notice Application Setting-Yes/No Select if or not the print end is indicated to the external
application.
(See “4.1.3 Setting the Notice Application” in the Instruction
Manual [Condition Setup and Maintenance].)

158
No. Item Description
14 [Notice Application Setting] Button Displays the “Notice Application Setting” screen.

5 Click the [OK] button.

159
SP1500/2000 or SLP800/1000) connected to
9.1.2 Setting by Using Tools
the DICII.
-Changing between the Earlier-type SP-FMPCII
(1) Copying Print Size from FD to S2
and the Earlier-type SP-No FMPCII.
3) After adding the media output service to the
Copy the print size settings from FD to S2 and then
system including the Earlier-type SP.
perform the required settings by using the
4) After changing the print sizes on the “Print Size
installation tool by following the procedure below.
Setup” screen.

1 On the S2, make a shift-start (Continue to press


■ Procedures for SP1500/2000
just after Desktop screen appears until the
hourglass cursor changes to the arrow cursor).
1 (On the S1) Before running the tool, check if the
2 Insert the FD created in “2.1.1 Copying Print “Pre-operational Check” is completed, and if the
Size Copy Tool (PrintsizeSnc.exe) to FD” and order information screen is displayed.
then execute “PrintsizeSnc.exe” in FD, then click
the [Write Reg] button. 2 (On the S2) Check if the main menu screen is
displayed after moving to the order information
screen once.

IMPORTANT
Every time this tool is run, check if the main
menu screen is displayed on the S2.
Click.
3 Insert the S2 installer CD into the CD drive of S2.

9.1.3 Activating Existing System


Installation (in case of Earlier-type
System)

IMPORTANT
The procedures in this section must be performed
after the “Pre-operational Check” is completed in
FRONTIER [A1].

Execute the Legacy Configuration Tool. To connect


the DICII to the conventional SP (SP1500/2000, R3-318
SLP800/1000) or to upgrade the conventional SP to
SP-3000, this tool must be executed. 4 Run “N:\Tools\LegacyConf\
LegacyConfigurationTool.exe” by selecting
This tool must be run after any of the following [Start] -> “Run”.
cases :

1) After upgrading the SP-DIC (C4/C5) to SP-DICII


(S2)
2) After changing the device configuration
-Changing the SP model (SP-3000/No SP,

160
5 The scanner selection dialog box appears. 9 The media output setting screen appears.

[In case of SP1500/2000]


NOTE1:
6 Select “SP1500/2000” then click the [OK] button. If the following error message appears, cancel
Select. the settings. Open the order information screen,
then main menu screen on the S2, and then
repeat Steps 4 - 9. If problems persist, the S2
(Client) may not be installed correctly. Reinstall
it. (See “7 S2 (Client) Installation for Earlier-type
FRONTIER”.)

Click.

7 In the FMPC connection confirmation dialog box,


select “Yes”, then click the [OK] button. NOTE2:
Select. If the following error message appears, cancel
the settings. Perform the “Pre-operational
Check” on the S2 and then repeat Steps 4 - 9. If
problems persist, check if the print sizes are
registered correctly, then try it again.

Click.

8 In the scanner computer name dialog box, enter


the computer name, then click the [OK] button.
Enter the computer name.

Click.

161
10 On the media output setting screen, perform the following settings.

(1) Select the service in the service list. (2) The setting items for the selected service appear.

(3) Select the number of


sets for CD-R.

(4) Select the number of


small index prints and its
size.

(5) Select the number of


large index prints and its
size.

11 Click the [OK] button.

■ Procedures for SLP800/1000 3 In the scanner computer name dialog box, enter
the computer name, then click the [OK] button.

1 Perform the Steps 1- 5 in the Procedures for Enter the computer name.
SP1500/2000.

2 Select “SLP800/1000” then click the [OK] button.


Select.

Click.

Click.

162
4 The media output setting screen appears. NOTE1:
If the following error message appears, cancel
the settings. Open the order information screen,
then main menu screen, and then repeat Steps 4
- 9. If problems persist, the S2 (Client) may not
be installed correctly. Reinstall it. (See “7 S2
(Client) Installation for Earlier-type FRONTIER”.)

NOTE2:
If the following error message appears, cancel
the settings. Perform the “Pre-operational
Check” and then repeat Steps 4 - 9. If problems
persist, check if the print sizes are registered
correctly, then try it again.

5 On the media output setting screen, perform the following settings.

(1) Select the service in the service name list. (2) The setting items for the selected service appear.

(3) Select the number of


sets for CD-R.

(4) Select the number of


small index prints and its
size.

(5) Select the number of


large index prints and its
size.

6 Click the [OK] button.

163
■ Procedures for SP-3000 5 The scanner selection dialog box appears.

1 (On the S1) Before running the tool, check if the


“Pre-operational Check” is completed, and if the
order information screen is displayed.

2 (On the S2) Check if the main menu screen is


displayed after moving to the order information
screen once.

IMPORTANT
Every time this tool is run, check if the main
menu screen is displayed on the S2. 6 Select “SP3000/Without SP”, then click the [OK]
button.

3 Insert the S2 installer CD into the CD drive. Select.

Click.

7 In the confirmation dialog box, click the [OK]


button.

R3-318

4 Run
[N:\Tools\LegacyConf\LegacyConfigurationTool.
exe] by selecting [Start] -> “Run”. Click.

8 The changes are saved in the system.

(3) Customizing Service Button and


Function Key Button

To customize the service button in the “Service


Menu” or assign the function to the function button,
see “Custom Button Setting Tool Instruction
Manual”.

164
9.2 S1 Settings

9.2.1 Setting by Using Tools 9.2.2 Server Operation Environment


Setup (0922)
(1) Copying Print Size from FD to S1
By perform the server operation environment setup
Copy the print size settings from A1 to S1 and then menu (0922), set up the server (DICII) name.
perform the required settings by using the Perform this setting after DICII is started up and the
installation tool by following the procedure below. main menu screen appears.

1 On the S1, make a shift-start (Continue to press 1 Restart the system. When the main menu is
just after Desktop screen appears until the displayed, click the [Setup and Maintenance]
hourglass cursor changes to the arrow cursor). button.

2
Click.
Insert the FD created in “2.1.1 Copying Print
Size Copy Tool (PrintsizeSnc.exe) to FD” and
then execute [PrintsizeSnc.exe] in FD, then click
the [Write Reg] button.

Click.

(2) Customizing Service Button and 2 Enter ‘7777’ as a password.

Function Key Button Enter ‘7777’.

To customize the service button in the “Service


Menu” or assign the function to the function button,
see “Custom Button Setting Tool Instruction
Manual”.

165
3 Select [(09) Order Control and Maintenance] ->
[(0922) Server Operation Environment Setup].

Select [(09) Order Control and Maintenance] ->


[(0922) Server Operation Environment Setup].

4 In the “Start-up Mode” column, select “Start


connection to the Imaging Controller” and then
enter the computer name of the DICII (FE-
FRONTEND) in the “Computer Name” box.

Select. Enter ‘FE-FRONTEND’.

5 Make sure DICII is started up and then click the


[OK] button. (When the dialog box for connecting
to the server appears, click the [OK] button.)

Click.

166
9.3 S7 Settings

9.3.1 Setting by Using Tools 9.3.2 Setup and Maintenance

(1) Copying Print Size from FD to S7 Perform the following settings on the “Setup and
Maintenance” menu.
Copy the print size settings from A1 to S7 and then,
using the installation tools, perform the required - Server Operation Environment Setup (0922)
settings by following the procedure below.
(1) Server Operation Environment Setup
1 On the S7, make a shift-start (Continue to press (0922)
just after Desktop screen appears until the
hourglass cursor changes to the arrow cursor). Perform the Server/DICII operation environment

2
setup menu (0922). Set up the server (DICII)
Insert the FD created in “2.1.1 Copying Print
Size Copy Tool (PrintsizeSnc.exe) to FD” and environment. Perform this setting after DICII is
then execute “PrintsizeSnc.exe” in FD, then click started up and the main menu screen appears.
the [Write Reg] button.
1 Restart the system. When the main menu is
displayed, click the [Setup and Maintenance]
button.
Click.

Click.

(2) Customizing Service Button and


Function Key Button

To customize the service button in the “Service


Menu” or assign the function to the function button,
see “Custom Button Setting Tool Instruction
Manual”. 2 Enter ‘7777’ as a password.
Enter ‘7777’.

167
3 Select [(09) Order Control and Maintenance] ->
[(0922) Server Operation Environment Setup].

Select [(09) Order Control and Maintenance] ->


[(0922) Server Operation Environment Setup].

4 In the “Start-up Mode” column, select “Start


connection to the Imaging Controller” and then
enter the computer name of the DICII (FE-
FRONTEND) in the “Computer Name” box.

Select. Enter “FE-FRONTEND”.

5 Make sure DICII is started up and then click the


[OK] button. (When the dialog box for connecting
to the server appears, click the [OK] button.)

Click.

168
9.4 S9 Settings

9.4.1 Setup and Maintenance 4 In the “Start-up Mode” column, select “Start
connection to the Imaging Controller” and then
Perform the following settings on the “Setup and enter the computer name of the DICII (FE-
FRONTEND) in the “Computer Name” box.
Maintenance” menu.

(1) Server Operation Environment Setup


(0922)

Perform the setting for connecting to DICII.

1 Restart the system. When the main menu is


displayed, click the [Setup and Maintenance]
button.

2 Enter ‘0000’ as a password.


Select. Enter ‘FE-FRONTEND’.

3 Select [(09) Order Control and Maintenance] ->


5 Make sure DICII is started up and then click the
[(0922) Server/DICII Operation Environment [OK] button. (When the dialog box for connecting
Setup]. to the server appears, click the [OK] button.)

Click.

Select [(09) Order Control and Maintenance] ->


[(0922) Sever/DICII Operation Environment Setup]. (2) Rack Auto Cleaning to ON (0625)

Enable “Rack Auto Cleaning” to “Yes” on the


“Processor Operating Condition Setup (0625)”.

(3) Creating Backup FD for FMPC/Printer/


Processor

Create the backup FD for FMPC/Printer/Processor.


(See “FMPC Installation/Service/Parts List
Manual”.)

169
(4) Set Timer for Printer/Processor (0121) (6) Other Maintenance Work

Set up the timer for printer/processor. (See “FMPC Perform other maintenance work. (See “FMPC
Installation/Service/Parts List Manual”.) Installation/Service/Parts List Manual”.)

(5) Copying Print Size from FD to S9

Copy the print size settings from FD to S9 and then


perform the required settings by using the
installation tool by following the procedure below.

1 On the S2, make a shift-start (Continue to press


just after Desktop screen appears until the
hourglass cursor changes to the arrow cursor).

2 Insert the FD created in “2.1.1 Copying Print


Size Copy Tool (PrintsizeSnc.exe) to FD”.

NMP014

3 Execute [PrintsizeSnc.exe] in FD, then click the


[Write Reg] button.

Click.

170
9.5 Setting on the Earlier-type FRONTIER

Perform the following setting on the earlier-type FRONTIER on the “[41I] DI Manager Administrative
Settings” screen.

Change this item only.

1 On this menu on the A1, enter ‘FMPCPD’ for “Logical Device Name”.

Device Name

IMPORTANT
Do not change the items other than “Logical Device Name”.

171
9.6 Environment Settings for S1/S2/S7/S9

Perform the following environment settings for each device (A1, S2, S7 and S9).

List 1 : Items essential to installation

Subject Contents Device Menu


System Setting the SP (S1), [0130] Server Operation Environment Setup
Connection computer E-DICII (S7),
and name of DICII FMPCII (S9)
Hardware
Setting

Setting the SP (S1) or [0140] Installation Information Setup


printer to be FMPCII (S9) [SP] [FMPCII]
connected

Enabling the SP (S1) [0140] Installation Information Setup


media input
function

172
Subject Contents Device Menu
System Setting media DICII (S2), [0136] Media Input Environment Setup
Connection drive E-DICII (S7)
and
Hardware
Setting

Setting CD-R DICII (S2) or [0137] Writing Service Output Settings


drive E-DICII (S7)

Setting the DICII (S2), [0138] Photo Copy Configuration


scanner to be E-DICII (S7)
connected

Setting 1394 FMPCII (S9) [0145] 1394 Connection Check


Connection
ON/OFF

173
Subject Contents Device Menu
System Adjusting the SP (S1) [0321] Focus Position Adjustment
Connection focus position
and
Hardware
Setting

Saving the SP (S1) [0350] Scanner Parameter Check/Update


parameter in
the circuit
board

Setting WFA DICII (S2), Device assignment tool


as home E-DICII (S7)
screen
Media output SP (S1), Device assignment tool
setting DICII (S2),
E-DICII (S7)
Setting auto or DICII (S2) Device assignment tool for KIOSK orders
manual order
processing

List 2 : Items for Lab policy (Default settings may be changed if necessary)

Subject Contents Device Menu


Lab policy Setting the SP (S1) or [0121] Timer Setup
setting printer/ FMPCII (S9)
processor
timer

174
Subject Contents Device Menu
Lab policy Setting the SP (S1), [0124] Equipment Name Set
setting equipment DICII (S2),
name E-DICII (S7),
(Displayed FMPCII (S9)
device name
in message)

Duration of SP (S1), [0125] Timer Waiting Time Setup


order DICII (S2),
information E-DICII (S7),
display FMPCII (S9)

Setting WFA SP (S1), [0920] Workflow Adviser Environment Setup


Environment DICII (S2),
(Display job E-DICII (S7),
and items) FMPCII (S9)

Setting for DICII (S2) [0921] System Operation Setting Setup


inspection

175
Subject Contents Device Menu
Lab policy Setting for DICII (S2) [0921] System Operation Setting Setup
setting billing
([Yes] : refer
List 3)

Setting LIOS's DICII (S2) [0921] System Operation Setting


print sizes

Setting service DICII (S2) [0921] System Operation Setting


time

Setting DICII (S2) [0921] System Operation Setting


application for
notification

Setting for DICII (S2) [0921] System Operation Setting


storing order
information

176
Subject Contents Device Menu
Lab policy Print out DICII (S2) [0924] Scheduling Mode Setting
setting Scheduling
Mode Setting
(for FMPCII)

Setting DICII (S2) [0926] Delivery Reply Setup


delivery time
for standard/
express orders

Setting DICII (S2) [0927] Holiday/Opening Time Setup


custom
holiday/
opening time

Setting print SP (S1), “Print Size Copy Tool” or/and [0220] Print Size Setup
size DICII (S2),
E-DICII (S7),
FMPCII (S9)

177
Subject Contents Device Menu
Lab policy Monitor SP (S1), [0222] Monitor Adjustment
setting Adjustment DICII (S2),
E-DICII (S7)

Setting Index SP (S1), [0227] Index Conditions


Conditions DICII (S2),
E-DICII (S7)

Setting Image SP (S1), [0240] Image Correction Setup


Correction DICII (S2),
E-DICII (S7)

Fine SP (S1) [0241] Fine Adjustment of the Print Mag. Setting


Adjustment of
the Print Mag.
Setting

178
Subject Contents Device Menu
Lab policy Image SP (S1) [0300] Image Scanning Method
setting Scanning
Method

Registration of SP (S1), “One-click Customization Tool” and [1023] Custom Button Regist/Save
user buttons DICII (S2),
E-DICII (S7)

Registration of SP (S1), [1024] Launcher Menu Regist/Delete


launchers DICII (S2),
E-DICII (S7),
FMPCII (S9)

Used when DICII (S2), Custom Information Copy Tool


upgrading from E-DICII (S7)
C4/C5 to S2

179
List 3 : Items for billing (If “Setting for billing” is “Yes”, these settings are necessary.)

Subject Contents Device Menu


Billing Setting product DICII (S2) “PLMaker” and [0921] System Operation Setting
Setting prices

Setting Billing DICII (S2), [0925] Billing Environment Setting


Environment E-DICII (S7),
(Display, FMPCII (S9)
Calculation (Only billing
method, sheet device)
etc.)

180
10 Appendix

10.1 Data Set Tool

By using the Data Set Tool, you can make the backup of the customized settings on the device (S1,
S2, S7 and S9), and can copy it to each device via the FD.

Backup Data stored in S1 Other S1


Copy

Backup Data stored in S2/S7 Other S2/S7


Copy

Backup Data stored in S9 Other S9


Copy

First, copy this tool to a floppy disk (FD).

IMPORTANT
Make sure to perform the following "10.1.1" and "10.1.2" on the same PC.

1 Insert a blank FD into the FD (A:) drive. 10.1.1 Saving Data onto FD

2 Insert Basic Software (S1/S2/S7/S9) CD into the (Perform this operation also in S2/S7/S9.)
CD-ROM drive.

3 Select “Setup and Maintenance” -> [(99) Special 1 On the SP of the FRONTIER for data saving,
select “Setup and Maintenance” -> [(99) Special
Operations] -> [(9941) Explorer].
Operations] -> [(9941) Explorer].

Select [(99) Special Operations] -> [(9941) Explorer].


Select [(99) Special Operations] -> [(9941) Explorer].

4 Execute “DataSetTool.bat” in the “N:\Tools” folder


2 Execute “DataSetTool.exe” in the floppy disk.
(CD drive).

181
3 Check [✓] the checkbox(es) for the customized 10.1.2 Copying Data to System
item(s) to be saved onto FD.
(Perform this operation also in S2/S7/S9.)

1 On the SP of the Frontier for data copying, select


“Setup and Maintenance” -> [(99) Special
Operations] -> [(9941) Explorer].

4 Click the [System->FD] button and then follow


the displayed messages.
Select [(99) Special Operations] -> [(9941) Explorer].

2 Set the FD to the FD drive, then execute


“DataSetTool.exe”.

3 Check [✓] the checkbox(es) for the customized


item(s) to be copied to the system.

Click.

5 When data saving is completed, the following


dialog box appears. Click the [OK] button.

Click.

6 Remove the FD from the FD drive.

182
4 Click the [FD-> System] button and then follow
the displayed messages.

Click.

[FD -> System] Button:


Copies the current parameters stored in the
system to the backup folder, then copies the
parameters in the FD to the system.

[Restore from the Backup Data] Button:


Copies the parameters in the backup folder to
the system.

5 When the following dialog box appears, remove


the FD and then restart the system.

Click.

183
10.2 Custom Data Copy Tool

By using the Custom Data Copy Tool, you can make the backup of the settings for digitizing services
customized on the DIC (C4/C5 version 5 or later), and can copy it to DICII (S2/S7) via the FD.

First, copy this tool to a floppy disk (FD).

1 Insert a blank FD into the FD (A:) drive. 10.2.1 Saving Data onto FD

2 Insert Basic Software (S2/S7) CD into the CD-


1 On the DIC (C4/C5), open the Explorer.
ROM drive.

3 Execute “CustomizeSetTool.bat” in the “N:/Tools”


folder by selecting [Start] -> “Run” on the
Desktop (Ex: "N" drive.)

2 Execute “CustomizeSetTool.exe” in the floppy


disk.

3 Click the [System->FD] button and then follow


the displayed messages.

Click.

4 When data saving is completed, the following


dialog box appears. Click the [OK] button.

Click.

184
10.2.2 Copying Data to System 3 Click the [FD->System] button.

1 On the DICII for data copying, select “Setup and


Maintenance” -> [(99) Special Operations] ->
[(9941) Explorer].

Click.

4 Click the [OK] button and then follow the


displayed messages.

Select [(99) Special Operations] -> [(9941) Explorer].

2
Click.
Insert the FD, then execute
[CustomizeSetTool.exe] in the floppy disk. 5 When data copying is completed, the following
dialog box appears.

Click.

10.3 Restrictions

1 Maximum number of PCs (including the PC


other than the ones in the FE system) in the
same workgroup is 32. To operate the system
including more than 33 PCs, set up the two
workgroups separately.

2 Maximum number of PCs other than the ones in


the FE system (such as KIOSK machine) is 6.

185
10.4 Anti-virus Software Settings

The settings for anti-virus vary depending on the software. This section explains the general
settings for folders and the format types of files to be scanned in the software.
Perform the following settings when the anti-virus software is installed on the PC where S1, S2, S7,
or S9 software is installed.

(1) Settings for Folders to be Scanned

Set up the folders for real-time scanning.


Add the following folders to the folder list for “Real-time Scanning”. Also add the sub-folder that exists under
them to the list.
: Setting Required - : Not Required

Folders Excluded from Real-time Scanning S2 S1/S7 S9


C:\PNS
D:\Fujifilm
D:\BackupLog
D:\Expcond -
D:\Overlay -
D:\Template -
D:\F-DIA - -
C:\Program Files\Microsoft SQL Server - -

(2) Files to be Scanned

Add the following file extensions to the extension list for “Real-time Scanning”.

File Extensions (common to S1, S2, S7 and S9)

.BAT, .BIN, .CMD, .COM, .DOC, .DOT, .DRV, .EXE, .SYS, .XLS, .XLA, .XLT, .VBS, .JS, .HTM, .HTML, .CLA,
.CLASS, .SCR, .MDB, .PPT, .DLL, .OCX, .OVL, .POT, .SHS, .PIF, .HLP, .HTA, .MPP, .MPT, .MSG, .OFT, .PPS,
.RTF, .VSD, .VST, .EML, .NWS, .ASP

186
11 Index

A ———Equipment Name Set (124) ......................... 62


Activating Existing System Installation ———Frontier Manager II Software (S8)
(only in case of Earlier-type System)............. 160 Installation ....................................................... 48
After-installation Work ............................................... 10 ———Full Automatic Red-eye Correction
Anti-virus Software Settings ................................... 186 Software (S12) Installation............................ 50
Appendix ................................................................... 181 ———Hide Setting of Screen Keyboard
Application Environment Settings ......................... 155 Dialog Box ....................................................... 32
———S1 Settings ................................................... 165 ———Holiday/Opening Time Setup (0927) .......... 56
———S2 Settings ................................................... 155 ———Index Conditions (0227) ............................... 61
———S7 Settings ................................................... 167 ———Installing the Speaker used
———S9 Settings ................................................... 169 for Indicating Order Completion ................... 52
———Setting on the Earlier-type FRONTIER .... 171 ———LIOS Order Processing Settings ................. 53
———LIOS User Registration ................................. 36
B ———Media Index Setting ...................................... 54
Before-installation Work ............................................. 9 ———Media Input Environment Setup (0136) ..... 59
Billing Data Preparation ............................................ 23 ———Media Output Setting .................................... 52
———Optional Software Installation ...................... 44
C ———Photo Copy Configuration (0138) ............... 60
Connections and Start-up ...................................... 153 ———PL-Maker Setting ........................................... 54
Custom Data Copy Tool ......................................... 184 ———Print Condition Setup .................................... 61
———Copying Data to System ............................. 185 ———Professional Color Correction
———Saving Data onto FD ................................... 184 Software (S5) Installation .............................. 47
———Receipt Printer/Barcode Reader Setup...... 52
D ———Red Eye Correction Setup (0201)
Data Set Tool ........................................................... 181 (only in case of the Earlier-type System).... 62
———Copying Data to System ............................. 182 ———Setting IE Page for Receipt Printer ............. 36
———Saving Data onto FD ................................... 181 ———Settings Completed with Batch File ............ 30
DIC Conditions ........................................................... 11 ———Shop Logo Regist/Delete (1020) ................. 63
DICII (S2) Installation ............................................... 25 ———System Error Setting ..................................... 31
———After-installation Work ................................... 52 ———Time Zone Setting (for each country) ......... 35
———Auto-hide Setting for Task Bar .................... 33 ———Tone Selection Software (S4) Installation . 46
———Billing Environment Setup (0133) ............... 63 ———Variety Print Software (S3) Installation ...... 44
———Custom Data Copy Tool ............................... 52 ———“Visual Notification” to ON
———[Date and Time Settings] Regional in Dr. Watson Dialog Box .............................. 34
and Language Settings ................................. 31 ———Windows Settings .......................................... 30
———Disabling Error Reporting ———Writing Service Settings (0137) ................... 59
(only in Windows XP) .................................... 32 DICII (S2) Installation Outlines................................ 25
———Disabling Security Center ———BIOS Setting and User Registration ........... 28
(only in Windows XP) .................................... 35 ———Hyper-threading Setup.................................. 28
———Disabling User Assistant Function .............. 32 ———Installation Procedure ................................... 25
———Disabling Windows Firewall ———Preliminary Work for S2-use Hardware ..... 26
(only in Windows XP) .................................... 34 ———User Registration ........................................... 28
———Disabling Windows XP Style DICII, FMPCII and LP5000 Series
(only in Windows XP) .................................... 30 (no SP) Configuration ...................................... 129
———Driver Software Installation .......................... 52 Disconnecting PU800B ........................................... 129

187
E ———Remote Desktop Settings (only in use of
E-DIC (Second DIC) Conditions.............................. 12 FMPC in the Earlier-type System) ............. 116
E-DICII (S7) Installation ........................................... 90 ———S7 Software Installation .............................. 101
———After-installation Work ................................. 110 ———Setting IE Page for Receipt Printer ........... 100
———Auto-hide Setting for Task Bar .................... 97 ———Settings Completed with Batch File ............ 94
———BIOS Setting and User Registration ........... 92 ———Shop Logo Regist/Delete (1020) ............... 115
———Custom Data Copy Tool ............................. 110 ———System Error Setting ..................................... 95
———[Date and Time Settings] Regional ———Time Zone Setting (for each country) ......... 99
and Language Settings ................................. 95 ———Tone Selection Software (S4)
———Disabling Error Reporting Installation ..................................................... 105
(only in Windows XP) .................................... 96 ———User Registration ........................................... 92
———Disabling Security Center ———Variety Print Software (S3) Installation .... 103
(only in Windows XP) .................................... 99 ———“Visual Notification” to ON
———Disabling User Assistant Function .............. 96 in Dr. Watson Dialog Box .............................. 98
———Disabling Windows Firewall ———Windows Settings .......................................... 94
(only in Windows XP) .................................... 98 ———Writing Service Settings (0137) ................. 113
———Disabling Windows XP Style E-DICII (S7) Installation Outlines............................ 90
(only in Windows XP) .................................... 94 ———Installation Procedure ................................... 90
———Driver Software Installation ........................ 110 Environment Settings for S1/S2/S7/S9 ................ 172
———Equipment Name Set (124) ....................... 115 Error Message.......................................................... 129
———Frontier Manager II Software (S8)
Installation ..................................................... 107 F
———Full Automatic Red-eye Correction FE Installation Procedure [Installing FE Software
Software (S12) Installation.......................... 108 in Earlier-type System] Pattern 3 ..................... 18
———Hide Setting of Screen Keyboard FE Installation Procedure [New Installation]
Dialog Box ....................................................... 96 Pattern 1 .............................................................. 14
———Hyper-threading Setup.................................. 92 FE Installation Procedure [Upgrading]
———Index Conditions (0227) ............................. 114 Pattern 2 .............................................................. 16
———Installing Remote Desktop Client .............. 116 FE System Connection Diagram ........................... 153
———Installing the Speaker used FMPCII Conditions .................................................... 12
for Indicating Order Completion ................. 110 FMPCII (S9) Installation ......................................... 119
———LIOS User Registration ............................... 100 ———1394 Connection Check
———Media Index Setting .................................... 111 (only in use of earlier system (FMPC)) ..... 149
———Media Input Environment Setup (0136) ... 112 ———After-installation Work ................................. 147
———Media Output Setting .................................. 110 ———Auto-hide Setting for Task Bar .................. 136
———Optional Software Installation .................... 103 ———BIOS Setting and User Registration ......... 130
———Photo Copy Configuration (0138) ............. 113 ———Copying Print Sizes
———PLMaker Setting .......................................... 111 from FMPC (S9) to FD ................................ 149
———Preliminary Work for S7-use Hardware ..... 91 ———[Date and Time Settings] Regional
———Print Condition Setup .................................. 115 and Language Settings ............................... 134
———Professional Color Correction ———Disabling Error Reporting ........................... 135
Software (S5) Installation ............................ 106 ———Disabling Security Center ........................... 138
———Receipt Printer/Barcode Reader Setup.... 110 ———Disabling User Assistant Function ............ 135
———Remote Desktop Setting ............................ 117 ———Disabling Windows Firewall ....................... 137
———Disabling Windows XP Style...................... 133

188
———Frontier Manager II Software (S8) ———Copying Print Size Copy Tool
Installation ..................................................... 144 (PrintsizeSnc.exe) to FD ............................... 20
———Full Automatic Red-eye Correction ———Copying Print Sizes
Software (S12) Installation.......................... 145 from FRONTIER to FD .................................. 21
———Hide Setting of Screen Keyboard ———Copying the Default Billing Data ................. 23
Dialog Box .................................................... 135 ———Print Size Setting Preparations ................... 20
———Hyper-threading Setup................................ 130 ———Registering the Price List
———Inhibition of IE Dialog Display in the Server Database.................................. 24
(for Web maintenance display) .................. 138 Installation Workflow ................................................... 9
———Installation Information Setup (0140) ....... 148 Installing .Net Framework V1.1 ............................... 40
———Media Output Setting .................................. 147 Installing IIS (Internet Information Services) ......... 38
———Optional Software Installation .................... 144 Installing MSDE2000 database engine SP3a ....... 38
———Precautions for Setting Installing Remote Desktop Client ............................ 64
IEEE1394 Driver ........................................... 121 Installing Windows Basic Software ......................... 37
———Preliminary Work for S9-use Hardware ... 120 Items essential to installation ................................. 172
———Remote Desktop Setting ............................ 139 Items for billing ......................................................... 180
———S9 Software Installation .............................. 141 Items for Lab policy ................................................. 174
———Setting IE Page for Receipt Printer ........... 140
———Setting IEEE1394 Driver ............................ 121 O
———Settings Completed with Batch File .......... 133 Outlines ......................................................................... 8
———System Error Setting ................................... 134
———Time Zone Setting (for each country) ....... 139 P
———User Registration ......................................... 130 Print Size Setting Preparations ............................... 20
———“Visual Notification” to ON
in Dr. Watson Dialog Box ............................ 137 R
———When Connecting FMP Controller Remote Desktop Setting .......................................... 65
to SP1500/2000 and LP1500/LP2000 ...... 125 Remote Desktop Settings (only in use of
———When Connecting FMP Controller FMPC in the Earlier-type System) ................... 64
to SP1500/2000 and LP5000 Series ......... 126 Restrictions ............................................................... 185
———When Connecting FMP Controller,
SP-3000 and LP1500/LP2000 ................... 123 S
———When Connecting FMP Controller, S1 Settings ............................................................... 165
SP-3000, LP-5500/LP-5700/LP-5900 ....... 121 ———Copying Print Size from FD to S1 ............. 165
———Windows Settings ........................................ 133 ———Customizing Service Button
FMPCII (S9) Installation Outlines ......................... 119 and Function Key Button ............................. 165
———Installation Procedure ................................. 119 ———Server Operation Environment
Setup (0922) ................................................. 165
I ———Setting by Using Tools ................................ 165
Installation Methods .................................................. 11 S2 (Client) Installation
Installation of Each Device ....................................... 10 for Earlier-type FRONTIER ............................. 151
Installation Outlines ..................................................... 8 ———After-installation Work ................................. 152
Installation Patterns ................................................... 13 ———Installation Information Setup .................... 152
Installation Preparation ............................................... 9 S2 (Client) Installation Procedure ......................... 151
Installation Preparations for S1/S2/S7/S9 ............. 20 S2 Settings ............................................................... 155
———Billing Data Preparation ................................ 23

189
———Activating Existing System Installation ———[Date and Time Settings] Regional
(in case of Earlier-type System) ................. 160 and Language Settings ................................. 71
———Copying Print Size from FD to S2 ............. 160 ———Equipment Name Set (0124) ....................... 88
———Customizing Service Button ———Frontier Manager II Software (S8)
and Function Key Button ............................. 164 Installation ....................................................... 78
———Equipment Name Set (0124) .............. 62, 115 ———Full Automatic Red-eye Correction
———Index Conditions (0227) ...................... 61, 114 Software (S12) Installation............................ 79
———LIOS Order Processing Settings ................. 53 ———Installation Information Setup (0140) ......... 88
———Setting by Using Tools ................................ 160 ———Media Output Setting .................................... 86
———Setup and Maintenance.............................. 155 ———Optional Software Installation ...................... 75
———System Operation Setting Setup (0129) .. 155 ———Professional Color Correction
S2 Software Installation ............................................ 41 Software (S5) Installation .............................. 77
S7 Settings ............................................................... 167 ———Remote Desktop Setting .............................. 82
———Copying Print Size from FD to S7 ............. 167 ———Remote Desktop Settings
———Customizing Service Button (Only when using the FMPCII) .................... 81
and Function Key Button ............................. 167 ———“Rollup 35” Installation Procedure .............. 71
———Server Operation ———S1 Software Installation
Environment Setup (0922) .......................... 167 (Upgrading from A1 to S1) ............................ 73
———Setting by Using Tools ................................ 167 ———Scanner and Carrier Adjustment/
———Setup and Maintenance.............................. 167 Maintenance menus ...................................... 88
S9 Settings ............................................................... 169 ———Scanner Parameter Check/
———1394 Connection Check (0145) ................ 149 Update (0350) ................................................. 87
———Copying Print Size from FD to S9 ............. 170 ———Shop Logo Regist/Delete (1020) ................. 89
———Creating Backup FD ———Time Zone Setting (for each country) ......... 71
for FMPC/Printer/Processor ....................... 169 ———Tone Selection Software (S4)
———Other Maintenance Work ........................... 170 Installation ....................................................... 76
———Rack Auto Cleaning to ON (0625) ............ 169 ———Variety Print Software (S3) Installation ...... 75
———Server Operation ———Windows Settings .......................................... 71
Environment Setup (0922) .......................... 169 SP (S1) Installation Outlines .................................... 70
———Set Timer for Printer/Processor (0121) .... 170 ———Installation Procedure ................................... 70
———Setup and Maintenance.............................. 169 ———Preliminary Work
Scanner (SP) Conditions .......................................... 11 for S1-use Hardware (SP-3000) .................. 70
Setting the HELP ....................................................... 66 Starting Up the System ........................................... 154
Set-up Conditions for Installation ............................ 11
SP (S1) Installation.................................................... 70 W
———After-installation Work ................................... 81 Windows Settings .................................30, 71, 94, 133
———Copying Print Sizes
from FRONTIER to FD ................................. 84

190
FAX : 81-3-5484-0454

Questionnaire concerning This Manual


Fujifilm’s Products Planning & Technical Service Division would be most grateful if you would make copies of this form, then
complete and send them to us by FAX.
Your opinions will contribute greatly to an accurate assessment of the overall quality of each manual.
All questions can be answered by ticking [✓] the appropriate box(es), but in addition to these answers, please provide us with your
written comments in the lined spaces following each block of questions.

Title : FRONTIER FE SYSTEM


DIC II BASIC SOFTWARE
Manual Title and Reference Number INSTALLATION MANUAL
Reference Number : PP3-A1311E

Name :

Your Name and Company


Company :

E-mail Address :

Your E-mail Address and FAX Number


FAX Number :

Question 1 • How would you rate this manual overall?


(1) Very easy to use and understand (2) Fairly easy to use and understand
(3) Slightly difficult to use
(4) Very difficult to use and understand
and understand
• Please provide us with your reasons and comments.

Question 2 • Have you found any technical errors, errors in spelling, or missing words in this manual?
Yes No
• If you have ticked (Yes), please let us know what these errors and missing words are.

Question 3 • How would you rate the writing (language, choice of words/phrases, etc.) and the illustrations/
diagrams, etc.?
(1) Clear and easy to follow (2) Should be simplified
(3) Difficult to follow
(1)’ [Illustrations, etc.] Of adequate size
(2)’ [Illustrations, etc.] Too small
(3)’ [Illustrations, etc.] Difficult to follow
• If you have ticked (2), (3) or (3)’, please give us your reasons.

Additional
Comments/
Requests
concerning
This Manual

Please return this questionnaire to : FAX No. : Tokyo 81-3-5484-0454


FUJI PHOTO FILM CO., LTD.
26-30, Nishiazabu 2-chome, Minato-ku, Tokyo 106-8620, Japan.

Printed on Recycled Paper


Ref.No.PP3-A1311E ESD-06.03-FP Printed in Japan