Blue Solar Charge Controller MPPT: Accepted
Blue Solar Charge Controller MPPT: Accepted
5
Module: 16
In series: 5 Parallel: 4
Coefficient support:
If you have the voltage temperature coefficient in mV/°C, here is how to change it to %/°C
Write the Voc value in Volt: 24.1
Write the coefficient value in mV/°C: -77
The coefficent value in %/°C is now: -0.320
If you have the current temperature coefficient in mA/°C, here is how to change it to %/°C
Write the Isc value in Ampere: 8.72
Write the coefficient value in mA/°C: 4.7
The coefficent value in %/°C is now: 0.054
Power Vmpp Impp Voc
[W] [V] [A] [V]
30 18 1.67 22.5
50 18 2.78 22.2
80 18 4.45 22.3
100 18 5.56 22.4
150 18 8.33 22.4
190 36 5.44 43.2
300 36 8.06 45.5
20 18 1.11 22.5
30 18 1.67 22.5
40 18 2.22 22.5
50 18 2.78 22.2
80 18 4.44 21.6
100 18 5.56 21.6
140 20 7.78 21.6
250 30 8.33 36.01
290 36 8.06 44.1
75 35.5 6.46 45
100 40.2 6.46 48
125 35.5 6.46 45
150 35.5 6.46 45
175 35.5 6.46 45
200 35.5 6.46 45
225 35.5 6.46 45
250 35.5 6.46 45
275 44.3 5.54 53
275 44.3 5.54 53
275 44.3 5.54 53
V
mV/°C
%/°C
A
mA/°C
%/°C
Isc V temp coeff I temp coeff Art.Nr.
[A] [%/°C] [%/°C]
2 -0.34 0.037 SPM030301200
3.16 -0.34 0.037 SPM030501200
4.96 -0.34 0.037 SPM030801200
6.53 -0.34 0.037 SPM031001200
9.8 -0.34 0.05 SPM031501200
5.98 -0.34 0.037 SPM031902400
8.56 -0.34 0.037 SPM033002400
1.23 -0.34 0.045 SPP030201200
1.85 -0.34 0.037 SPP030301200
2.45 -0.34 0.037 SPP020401200
3.09 -0.34 0.037 SPP030501200
5.06 -0.34 0.037 SPP030801200
6.32 -0.35 0.037 SPP031001200
8.85 -0.35 0.037 SPP031401200
9.4 -0.34 0.045 SPP032502001
8.56 -0.34 0.045 SPP032902400
8.5 -0.33 0.06
8.5 -0.33 0.06
8.5 -0.33 0.06
8.5 -0.33 0.06
8.5 -0.33 0.06
8.5 -0.33 0.06
8.5 -0.33 0.06
8.5 -0.33 0.06
5.86 -0.25 0.03
5.86 -0.25 0.03
5.86 -0.25 0.03
Manufacturer
Victron Energy Blue-/ SmartSolar MPPT 75/10 Victron Energy
Victron Energy Blue-/ SmartSolar MPPT 75/15 Victron Energy
Victron Energy Blue-/ SmartSolar MPPT 100/15 Victron Energy
Victron Energy Smart Solar MPPT 100/20 Victron Energy
Victron Energy Blue-/ SmartSolar MPPT 100/30 Victron Energy
Victron Energy Blue-/ SmartSolar MPPT 100/50 Victron Energy
Victron Energy Blue-/ SmartSolar MPPT 150/35 Victron Energy
Victron Energy BlueSolar MPPT 150/45 Tr/MC4 Victron Energy
Victron Energy BlueSolar MPPT 150/60 Tr/MC4 Victron Energy
Victron Energy BlueSolar MPPT 150/70 Tr/MC4 Victron Energy
Victron Energy SmartSolar MPPT 150/85 Tr/MC4 Victron Energy
Victron Energy SmartSolar MPPT 150/100 Tr/MC4 Victron Energy
Victron Energy SmartSolar MPPT 250/60 Tr/MC4 Victron Energy
Victron Energy SmartSolar MPPT 250/70 Tr/MC4 Victron Energy
Victron Energy SmartSolar MPPT 250/85 Tr/MC4 Victron Energy
Victron Energy SmartSolar MPPT 250/100 Tr/MC4 Victron Energy
Victron Energy BlueSolar MPPT 150/70 VE.Can Victron Energy
Victron Energy BlueSolar MPPT 150/85 VE.Can Victron Energy
Type Power @ 12V Power @ 24V Power @ 36V Power @ 48V
Blue-/ SmartSolar MPPT 75/10 135 270 0 0
Blue-/ SmartSolar MPPT 75/15 200 400 0 0
Blue-/ SmartSolar MPPT 100/15 200 400 0 0
Smart Solar MPPT 100/20 290 580 0 0
Blue-/ SmartSolar MPPT 100/30 440 880 0 0
Blue-/ SmartSolar MPPT 100/50 700 1400 0 0
Blue-/ SmartSolar MPPT 150/35 500 1000 1500 2000
BlueSolar MPPT 150/45 Tr/MC4 650 1300 2600
BlueSolar MPPT 150/60 Tr/MC4 860 1720 3440
BlueSolar MPPT 150/70 Tr/MC4 1000 2000 4000
SmartSolar MPPT 150/85 Tr/MC4 1200 2400 4900
SmartSolar MPPT 150/100 Tr/MC4 1450 2900 5800
SmartSolar MPPT 250/60 Tr/MC4 860 1720 3440
SmartSolar MPPT 250/70 Tr/MC4 1000 2000 4000
SmartSolar MPPT 250/85 Tr/MC4 1200 2400 4900
SmartSolar MPPT 250/100 Tr/MC4 1450 2900 5800
BlueSolar MPPT 150/70 VE.Can 1000 2000 3000 4000
BlueSolar MPPT 150/85 VE.Can 1200 2400 3600 4850
Voc max Voc min Vmpp min System Voltage IPV max Ibat max Efficiency@12
75 +5V +1V 12 24 N.A. N.A. 13 10 0.98
75 +5V +1V 12 24 N.A. N.A. 15 15 0.98
100 +5V +1V 12 24 N.A. N.A. 15 15 0.98
100 +5V +1V 12 24 N.A. N.A. 20 20 0.98
100 +5V +1V 12 24 N.A. N.A. 30 30 0.98
100 +5V +1V 12 24 N.A. N.A. 50 50 0.98
150 +5V +1V 12 24 36 48 40 35 0.98
150 +5V +1V 12 24 36 48 50 45 0.98
150 +5V +1V 12 24 36 48 50 60 0.98
150 +5V +1V 12 24 36 48 50 70 0.98
150 +5V +1V 12 24 36 48 70 85 0.98
150 +5V +1V 12 24 36 48 70 100 0.98
250 +5V +1V 12 24 36 48 35 60 0.99
250 +5V +1V 12 24 36 48 35 70 0.99
250 +5V +1V 12 24 36 48 70 85 0.99
250 +5V +1V 12 24 36 48 70 100 0.99
150 +7V +2V 12 24 36 48 50 70 0.95
150 +7V +2V 12 24 36 48 70 85 0.95
Efficiency@24 Efficiency@36 Efficiency@48
0.98 0 0
0.98 0 0
0.98 0 0
0.98 0 0
0.98 0 0
0.98 0 0
0.98 0.98 0.98
0.98 0.98 0.98
0.98 0.98 0.98
0.98 0.98 0.98
0.98 0.98 0.98
0.98 0.98 0.98
0.99 0.99 0.99
0.99 0.99 0.99
0.99 0.99 0.99
0.99 0.99 0.99
0.965 0.97 0.975
0.965 0.97 0.975
DATA:
Location: -10 °C
70 °C
RESULTS:
Voc @25°C
Vmpp @25°C
Isc PV@25°C
Impp PV @25°C
Impp output @25°C
Temp. Coeff. Voc
Temp. Coeff. Voc absolute
Temp. Coeff. Isc
Temp. Coeff. Isc absolute
Choosen PV power
Cupper resistance
Factor
If more than 1.3 the user becomes an alert that he/ she is oversizing the PV generator with more than 30%
igher than maximum regulator input current 0
(Col 19 )
String Vmpp max. String Vmpp corr.max. String Voc min. String Vmpp min.
206.2 V 204.4
202.5 V 200.6
198.7 V 196.9
195.0 V 193.1
198.0 V 157.5 V
194.3 V 153.8 V
190.5 V 150.0 V
186.8 V 146.3 V
100.00 A
100.00 A
100.00 A
99.35 A
155.6 V
151.8 V
148.1 V
144.3 V
History
2.7 - Added 150Wp mono module, SmartSolar 250/60 & 70 and maximum input current
2.6 - Added Smart Regulators and SmartSolar 100/20
2.5 - Added translations for 'coefficient support' in the modules TAB
2.4 - Bug fixed for max. charge current calculations
2.3 - Replaced solar modules according newest list. Added 2 SmartSolar MPPT's 250/85 & 250/100 & a remark when th
2.2 - Added the MPPT 150/85 Tr/MC4 and 150/100 Tr/MC4 & added two cable sizes 16mm² & 35mm²
2.1 - Added the Poly module with 190Wp & added the new VE.Direct MPPT's 150/45, 150/60 & 150/70, small correctio
2.0 - Added the MPPT 75/10 and took out the discontinued 75/50
1.9 - Added new solar modules, and now 10 additional modules can be added instead of 3.
1.8 - Added a small calculation on the 'Modules' TAB to help when temperature coefficiences are not in %/°C or %/°K b
1.7 - Added new solar modules, voltage drop correction and an option to rise the cell temperature in the example list,
1.6 - Inserted 4 new regulators and 2 more custom module.
1.5 - Inserted 4 languages @ updated not applicable (N.A.) voltages for 75/15, 75/50 & 100/15.
1.4 - Changed texts and Module temperature window.
1.3 - Power reduction comment set @ highest temperature.
1.2 - Reduced output current to maximum output current at low & high temperatures. Now a system will show 'power
1.1 - Inserted BlueSolar MPPT 100/15. Inserted custom module
1.0 - First version
0.1 - This Excel gives an indication how to calculate Victron Energy MPPT's
/100 & a remark when the PV generator is oversized.
system will show 'power loss' only wenn the output current exceeds the max. at low & high temperatures.